Leaching of hydrogen peroxide from bleached bovine enamel.

Accurately weighed bovine enamel slabs were individually immersed in 2 ml of 35% hydrogen peroxide for 1, 3, 5, 30, or 60 min. A control group was obtained by individual immersion of bovine enamel slabs in 2 ml of saline for 60 min. All samples were washed, dried, acid-etched with 37% phosphoric acid for 60 s, then washed and dried again. Two milliliters of double-distilled water were used for individual sample leaching. Leaching was done for 1, 5, 10, 20 min, or 7 days for the experimental groups and for 7 days for the control group. The samples of one of the experimental groups were leached for a second time for 1 min. A total of 112 samples was used in this study. Hydrogen peroxide was spectrophotometrically identified and quantified in all leaching solutions based on the oxidation reaction of leuco-crystal violet buffer solution by hydrogen peroxide, a reaction catalyzed by horseradish peroxidase. The results revealed a significant difference in the quantity of leached peroxide between bleached samples (irrespective of the duration of leaching) and control, saline-treated ones. No difference was observed in the quantity of leached peroxide between releached samples and control, saline-treated ones. However, these were small, random, and numerically insignificant. Statistically significant differences were also noted among some of the experimental groups. They were thought to hold no clinical significance. The results suggested that upon immersion, the complete leaching of peroxide from bleached enamel occurs rapidly.

Animals

The effect of carbamide-peroxide gel on the shear bond strength of a microfil resin to bovine enamel.

Cylinders of a visible-light-cured microfil resin were formed on, and bonded to, the flattened labial enamel surfaces of young bovine incisor teeth which had previously been subjected to four different treatments: (1) immersion in 10% carbamide-peroxide gel, pH 4.7, for three h; (2) immersion in 10% carbamide-peroxide gel, pH 4.7, for six h; (3) immersion in 10% carbamide-peroxide gel, pH 7.2, for three h; and (4) immersion in 10% carbamide-peroxide gel, pH 7.2, for six h. For each experimental group, a control group of resin-bonded to saline-immersed teeth was prepared. In addition, two groups, prepared according to treatment 4, were leached in distilled water for one and seven d, respectively, prior to resin application. Specimens were stored in distilled water at 37 degrees C for seven d prior to shear-bond-strength testing. A total of 90 teeth was tested. Statistical analysis of the results indicated that there was a highly significant reduction in the shear bond strength to carbamide-peroxide-treated enamel as compared with that to saline-treated enamel. The effects of duration of peroxide treatment and pH, as well as the interaction term, were not statistically significant. Leaching of the peroxide-treated enamel in water for either one or seven d prior to resin application restored the adhesiveness of the enamel. Scanning electron microscopic examination of randomly selected, fractured test specimens indicated that the peroxide-induced reduction in enamel adhesiveness was related to alterations in both attachment-surface area at the resin-enamel interface and resin quality.

Analysis of Variance

Scanning electron microscopy observations on the penetration and structure of resin tags in bleached and unbleached bovine enamel.

The purpose of this study was to determine the effect of hydrogen peroxide on the ability of composite resin to penetrate bovine enamel etched with phosphoric acid. In a previous investigation, the flattened enamel surfaces of extracted bovine incisors were immersed in either saline (control) or 35% hydrogen peroxide (experimental) for 5 or 30 min before or after acid etching with 37% phosphoric acid gel for 60 s. A standard-sized light-cured resin cylinder was then bonded to the enamel surface. The specimens were stored in a water bath at 37 degrees C for 1 day or 7 days, after which the enamel-resin bond was tensile tested to failure. Sixteen of the failed specimens (eight control and eight experimental) were randomly selected for the present scanning electron microscopic study to evaluate the appearance of the resin tags at the resin-enamel interface. In the control specimens, the tags were well defined and contiguous with resin which was uniformly adherent to the enamel surface. In the experimental specimens, large areas of the enamel surface were free of resin. When tags were present, they were fragmented, poorly defined, and penetrated to a lesser depth than in the saline controls. The changes observed suggest that there may be interaction between resin and residual peroxide at or near the enamel surface.

Acid Etching, Dental

Effect of water leaching the adhesion of composite resin to bleached and unbleached bovine enamel.

Standardized cylinders of light-cured composite resin were bonded to the ground labial enamel surface of bovine incisor teeth that had been immersed in double-distilled water for 7 days after having been (a) immersed in hydrogen peroxide for 5, 30, or 60 min, then etched for 60 s with 37% phosphoric acid; (b) immersed in saline for 5, 30, or 60 min, then etched for 60 s with 37% phosphoric acid; (c) etched with 37% phosphoric acid for 60 s, then immersed in hydrogen peroxide for 5, 30, or 60 min; or (d) etched with 37% phosphoric acid for 60 s, then immersed in saline for 5, 30, or 60 min. The enamel surface was washed with water for 1 min and dried with compressed air for 30 s prior to applying the resin. The tooth and applied resin were stored in water at 37 degrees C for 1 day prior to shear and tensile testing. A total of 192 specimens was used, 8 for each enamel preparation mode, for each time period, and for each test. Test values were tabulated and statistically analyzed. Analysis of variance revealed significantly higher bond strength values (p less than 0.005) for hydrogen peroxide-treated as compared with saline-treated specimens. A significant interaction was also noted between test solution and etching order. Scanning electron microscopic examination of failed shear- and tensile-tested specimens revealed no significant solution-related differences in the fracture pattern or the resin quality.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance