Search PubMed⌕ Search

Biomedical subjects

Judy Hung

Publications and source records attributed to Judy Hung.

12 recordsLinked to original sources

Geometric determinants of functional tricuspid regurgitation: insights from 3-dimensional echocardiography.

BACKGROUND: Tricuspid regurgitation (TR) is an important predictor of morbidity and mortality in heart failure. We aimed to examine the 3D geometry of the tricuspid valve annulus (TVA) in patients with functional TR, comparing them with patients with normal tricuspid valve function and relating annular geometric changes to functional TR. METHODS AND RESULTS: TVA shape was examined by real-time 3D echocardiography in 75 patients: 35 with functional TR and 40 with normal tricuspid valve function (referent group). The 3D shape of the TVA was reconstructed from rotated 2D planes, and the annular plane was computed by least-squares fitting. Annular area and mediolateral, anteroposterior, and high (superior)-low (inferior) distances were calculated. TR was assessed by vena contracta width. The normal TVA has a bimodal pattern (high-low distance=7.23+/-1.05 mm). High points were located anteroposteriorly, and low points were located mediolaterally. With moderate or greater TR (vena contracta width 5.80+/-2.62 mm), the TVA became dilated (17.24+/-4.75 versus 9.83+/-2.18 cm2, P<0.0001, TR versus referent), more planar with decreased high-low distance (4.14+/-1.05 mm), and more circular with decreased ratio of mediolateral/anteroposterior (1.11+/-0.09 versus 1.32+/-0.09, P<0.0001, TR versus referent). CONCLUSIONS: The normal TVA has a bimodal shape with distinct high points located anteroposteriorly and low points located mediolaterally. With functional TR, the annulus becomes larger, more planar, and circular. These changes in annular shape with TR have potentially important mechanistic and therapeutic implications for tricuspid valve repair.

Arrhythmias, Cardiac↗

A continuous murmur.

A 61-year-old male with a history of a mechanical Bjork-Shiley aortic valve replacement in 1977 and repair of an ascending aortic root dissection in 1993, presented with a 2-week history of fatigue and exertional dyspnea. Echocardiography confirmed the presence of an aortic pseudoaneurysm with a fistulous connection between the aorta and right atrium, which subsequently underwent successful repair. Although there have been several cases describing the development of an aortic pseudoaneurysm after aortic dissection repair, our case is the first to describe an aorta-atrial fistula as a long-term complication of a previous aortic dissection repair.

Aortic Dissection↗

New locus for autosomal dominant mitral valve prolapse on chromosome 13: clinical insights from genetic studies.

BACKGROUND: Mitral valve prolapse (MVP) is a common disorder associated with mitral regurgitation, endocarditis, heart failure, and sudden death. To date, 2 MVP loci have been described, but the defective genes have yet to be discovered. In the present study, we analyzed a large family segregating MVP, and identified a new locus, MMVP3. This study and others have enabled us to explore mitral valve morphological variations of currently uncertain clinical significance. METHODS AND RESULTS: Echocardiograms and blood samples were obtained from 43 individuals who were classified by the extent and pattern of displacement. Genotypic analyses were performed with polymorphic microsatellite markers. Evidence of linkage was obtained on chromosome 13q31.3-q32.1, with a peak nonparametric linkage score of 18.41 (P<0.0007). Multipoint parametric analysis gave a logarithm of odds score of 3.17 at marker D13S132. Of the 6 related individuals with mitral valve morphologies not meeting diagnostic criteria but resembling fully developed forms, 5 carried all or part of the haplotype linked to MVP. CONCLUSIONS: The mapping of a new MVP locus to chromosome 13 confirms the observed genetic heterogeneity and represents an important step toward gene identification. Furthermore, the genetic analysis provides clinical lessons with regard to previously nondiagnostic morphologies. In the familial context, these may represent early expression in gene carriers. Early recognition of gene carriers could potentially enhance the clinical evaluation of patients at risk of full expression, with the ultimate aim of developing interventions to reduce progression.

Adult↗

Usefulness of three-dimensionally guided assessment of mitral stenosis using matrix-array ultrasound.

Two-dimensional (2-D) planimetry is limited by the technical demands, time, and observer variability required to locate the minimal orifice area, limiting the confident clinical reporting of mitral valve area (MVA). In 27 consecutive patients, MVA was determined independently by 2 observers using the conventional 2-D method and a new 3-D-guided method. Using a matrix-array probe, the valve was visualized in a long-axis view and a cursor steered to intersect the leaflet tips and provide a perpendicular short-axis plane viewed side-by-side. Two-dimensional and 3-D-guided methods allowed planimetry in 24 patients. Consistent with better orifice localization, 3-D guidance eliminated the overestimation of internal orifice diameters in the planimetered short-axis view relative to the limiting diameter defined by the long-axis view (for 3-D guidance, 0.73 +/- 0.20 vs 0.73 +/- 0.21 cm, p = 0.98, vs 0.90 +/- 0.27 cm in the 2-D short-axis view, p <0.01). Accordingly, mean values for the smallest orifice area by 3-D guidance were less than by 2-D imaging (1.4 +/- 0.5 vs 1.5 +/- 0.5 cm(2), p <0.01), changing the clinical severity classification in 11 of 24 patients (46%). The 2-D method also overestimated MVA relative to 3-D guidance compared with Doppler pressure halftime and (n = 6) Gorlin areas. Phantom studies verified no differences in resolution for the 2 acquisition modes. Three-dimensional guidance reduced intraobserver variability from 9.8% to 3.8% (SEE 0.14 to 0.06 cm(2), p <0.01) and interobserver variability from 10.6% to 6.1% (SEE 0.15 to 0.09 cm(2), p <0.02). In conclusion, matrix-array technology provides a feasible and highly reproducible direct 3-D-guided method for measuring the limiting mitral orifice area.

Adult↗

Usefulness of left atrial emptying fraction to predict exercise capacity in patients with normal systolic left ventricular function and without myocardial ischemia.

The association of left atrial volume at rest and the left atrial emptying fraction with exercise capacity during stress echocardiography was examined in patients with normal left ventricular function and without ischemia. The left atrial emptying fraction, along with body mass index, was found to be an independent predictor of poor exercise capacity (<5 METs).

Adult↗

Mechanism of recurrent ischemic mitral regurgitation after annuloplasty: continued LV remodeling as a moving target.

BACKGROUND: Patients who undergo ring annuloplasty for ischemic mitral regurgitation (MR) often have persistent or recurrent MR. This may relate to persistent leaflet tethering from left ventricle (LV) dilatation that is not relieved by ring annuloplasty. Therefore, the purpose of this study was to test the hypothesis that recurrent MR in patients after ring annuloplasty relates to continued LV remodeling. METHODS AND RESULTS: Serial echoes were reviewed in 30 patients (aged 72+/-11 years) who showed recurrent MR late (47+/-27 months) versus early (3.8+/-5.8 months) after ring annuloplasty for ischemic MR during coronary artery bypass grafting without interval infarction. Patients with intrinsic mitral valve disease were excluded. Echocardiographic measures of MR (vena contracta and jet area/left atrial area) and LV remodeling (LV dimensions, volumes, and sphericity) were assessed at each stage. The degree of MR increased from mild to moderate, on average, from early to late postoperative stages, without significant change in LV ejection fraction. Changes in MR paralleled increases in LV volumes and sphericity index at end-systole and end-diastole. The only independent predictor of late postoperative MR was LV sphericity index at end-systole. CONCLUSIONS: Recurrent MR late after ring annuloplasty is associated with continued LV remodeling, emphasizing its dynamic relation to the LV.

Aged↗

Leaflet concavity: a rapid visual clue to the presence and mechanism of functional mitral regurgitation.

Repairing mitral regurgitation (MR) requires an understanding of its mechanism. Evaluating restricted leaflet closure in functional MR is challenging. Tenting area between leaflets and annulus in long-axis (LAX) views correlates with MR, but is positive even in control subjects; in the 4-chamber view, the incomplete mitral leaflet closure (IMLC) tenting pattern may be subtle and variable. We tested the hypothesis that leaflet concavity toward the left atrium in the LAX view, a rapid visual clue indicating abnormal tethering predominantly by intermediate chords, is a strong indicator of functional MR. We reviewed 90 patients: 40 with inferior myocardial infarction and ejection fraction > or = 50%; 40 with global left ventricular dysfunction and ejection fraction < 50%; and 10 control subjects. We assessed leaflet shape (concave or convex toward the left atrium) and maximum systolic proximal MR jet width in the LAX views. To quantify shape, we measured the leaflet concavity area between the anterior leaflet and a line connecting its ends. Conventional IMLC area was also assessed. Patients with leaflet concavity had significantly greater MR than those without this finding (jet width of 4.6 +/- 0.7 vs 0.5 +/- 0.1 mm, P <.0001), indicating mild-moderate versus trace MR, with differences comparable in those with inferior myocardial infarction and left ventricular dysfunction. Leaflet concavity area most strongly predicted MR by multivariate regression (R(2) = 0.7). Conventional IMLC area did not uniquely distinguish patients with or without MR and correlated more weakly with MR (R(2) = 0.30 vs 0.73). Mitral leaflet concavity in the LAX view provides rapid and reliable recognition of functional MR, with greater reliability than IMLC area. This shape, consistent with tethering by intermediate chords, may have implications for potential intervention.

Aged↗

Reverse ventricular remodeling reduces ischemic mitral regurgitation: echo-guided device application in the beating heart.

BACKGROUND: In ischemic mitral regurgitation (MR), mitral leaflet closure is restricted by ventricular remodeling with displacement of the papillary muscles (PMs). Therapy is uncertain because ring annuloplasty does not alleviate PM displacement. We tested the hypothesis that echo-guided PM repositioning using an external device can reduce MR without compromising left ventricular (LV) function. METHODS AND RESULTS: We studied 10 sheep with ischemic MR produced by circumflex ligation with inferior infarction, 6 acutely and 4 eight weeks after myocardial infarction (MI). A Dacron patch containing an inflatable balloon was placed over the PMs and adjusted under echo guidance to reverse LV remodeling and reposition the infarcted PM. 3D echo assessed mitral valve geometric changes. In 7 sheep, sonomicrometry and Millar catheters assessed changes in end-systolic and end-diastolic pressure-volume relationships, and microspheres were injected to assess coronary flow. Moderate MR after MI resolved with patch application alone (n=3) or echo-guided balloon inflation, which repositioned the infarcted PM, decreasing the PM tethering distance from 31.1+/-2.5 mm after MI to 26.8+/-1.8 with patch (P<0.01; baseline=25.5+/-1.5). LV contractility was unchanged (end-systolic slope=3.4+/-1.6 mm Hg/mL with patch versus 2.8+/-1.6 after MI). Although there was a nonsignificant trend for a mild increase in stiffness constant (0.07+/-0.05 mL(-1) versus 0.05+/-0.03 after MI, P=0.06), LV end-diastolic pressure was unchanged as MR resolved. Coronary flow to noninfarcted regions was not reduced. CONCLUSIONS: An external device that repositions the PMs can reduce ischemic MR without compromising LV function. This relatively simple technique can be applied under echo guidance in the beating heart.

Angioplasty, Balloon↗

Percutaneous transcatheter closure of patent foramen ovale in patients with paradoxical embolism.

BACKGROUND: Percutaneous transcatheter closure of patent foramen ovale (PFO) is used as an alternative to surgery or long-term anticoagulation for the treatment of patients with paradoxical embolism and PFO. METHODS AND RESULTS: We report the immediate and long-term clinical and echocardiographic outcome of 110 consecutive patients (58 males, mean age 47+/-14 years) who underwent transcatheter closure of PFO because of paradoxical embolism between 1995 and 2001. Procedural success, defined as successful deployment of the device and effective occlusion (no, or trivial, shunt after device placement), was achieved in all (100%) patients. There was no in-hospital mortality, 1 device migration requiring surgical intervention (0.9%), and 1 episode of cardiac tamponade (0.9%) requiring pericardiocentesis. A progressive increment in full occlusion was observed (44%, 51%, 66%, and 71% at 1 day, 6 months, and 1 and 2 years, respectively, after device placement). At a mean follow-up of 2.3 years, 2 patients experienced recurrent neurological events (1 fatal stroke and 1 transient ischemic attack), representing an annual risk of recurrence of 0.9%. In addition, 4 (3.6%) of the patients required reintervention for device malalignment or significant shunt. Kaplan-Meier analysis showed a freedom from recurrent embolic events and reintervention of 96% and 90% at 1 and 5 years, respectively. CONCLUSIONS: Transcatheter closure of PFO is a safe and effective therapy for patients with paradoxical embolism and PFO. It is associated with a high success rate, low incidence of hospital complications, and low frequency of recurrent systemic embolic events.

Cardiac Catheterization↗

Mechanistic insights into functional mitral regurgitation.

Effective valve repair in patients with mitral regurgitation (MR) demands an understanding of its mechanism. In patients with ischemic heart disease and functional MR, which doubles late mortality, normal leaflets are apically displaced. This reflects an altered balance of forces acting on the leaflets: increased tethering forces restricting closure, resulting from an altered geometry of leaflet attachments, and decreased ventricular forces acting to close the leaflets. Extensive evidence confirms a central and predominant role of tethering as the final common pathway inducing functional MR; left ventricular (LV) pressure dynamically modulates the orifice area. Because ischemic MR is a disease of the entire mitral complex, including the remodeling LV, reducing annular size alone is often ineffective. Undersizing rings attempts to compensate for tethering; new and potentially more effective strategies directly address tethering by infarct plication, papillary muscle repositioning with a localized patch, or basal chordal cutting to increase coaptational surface area without prolapse. A comprehensive understanding of the valve in its ventricular context, therefore, provides new opportunities for successful valve repair in patients.

Humans↗

Viability of hypokinetic segments: influence of tethering from adjacent segments: influence of tethering from adjacent segments.

Hypokinetic myocardium is presumed to be reversibly dysfunctional. However, hypokinetic segments do not necessarily improve after revascularization since their outcome can be influenced by tethering effects of adjacent myocardium. To assess whether hypokinetic segments improve following revascularization, 24 patients underwent resting and dobutamine stress echocardiography (DSE), with a total of 420 (20 per patient) myocardial segments studied pre- and postrevascularization. One hundred fifty-five hypokinetic segments were identified prerevascularization. Postrevascularization, only 57% of these segments improved in wall motion, while 43% showed no improvement or worsening of wall motion. Low dose (5-10 microg/kg/min) DSE identified correctly 57 (65%) of 88 segments that improved, and falsely predicted improvement in 26 (39%) of 67 segments that ultimately did not improve postrevascularization. Of the hypokinetic segments that did not improve, 90% were adjacent to at least one severely hypokinetic or akinetic segment as compared with 73% of the segments that improved following revascularization (P = 0.009). Sixty-five percent of all true positive DSE responses were adjacent to at least one akinetic or severely hypokinetic segment, while 87% of all false negative DSE responses were adjacent to at least one akinetic or severely hypokinetic segment (P = 0.03). In conclusion, myocardial segments found to be hypokinetic do not necessarily improve after revascularization. This may be related to tethering influences of adjacent segments, which have a contrasting level of function.

Coronary Disease↗