Search PubMed⌕ Search

Biomedical subjects

Juan G Santiago

Publications and source records attributed to Juan G Santiago.

13 recordsLinked to original sources

Detection of 100 aM fluorophores using a high-sensitivity on-chip CE system and transient isotachophoresis.

We present a highly sensitive capillary electrophoresis (CE) assay that combines transient, single-interface on-chip isotachophoresis (ITP) and a laser-induced confocal fluorescence detection setup. We performed experimental parametric studies to show the effects of microscope objective specifications and intensity of excitation laser on optimization of a high-sensitivity on-chip CE detection system. Using the optimized detection system, single-molecule detection of Alexa Fluor 488 was demonstrated, and signal data were validated with autocorrelation analysis. We also demonstrated a separation and detection of 100 aM fluorophores (Alexa Fluor 488 and bodipy) in a fast assay using a high-sensitivity on-chip CE detection system and an ITP/CE protocol with no manual buffer exchange steps. This is, to the knowledge of the authors, the highest electrophoretic separation sensitivity ever reported.

Journal Article↗

Electrophoresis in nanochannels: brief review and speculation.

The relevant physical phenomena that dominate electrophoretic transport of ions and macromolecules within long, thin nanochannels are reviewed, and a few papers relevant to the discussion are cited. Sample ion transport through nanochannels is largely a function of their interaction with electric double layer. For small ions, this coupling includes the net effect of the external applied field, the internal field of the double layer, and the non-uniform velocity of the liquid. Adsorption/desorption kinetics and the effects of surface roughness may also be important in nanochannel electrophoresis. For macromolecules, the resulting motion is more complex as there is further coupling via steric interactions and perhaps polarization effects. These complex interactions and coupled physics represent a valuable opportunity for novel electrophoretic and chromatographic separations.

Journal Article↗

Optimization of a microfluidic mixer for studying protein folding kinetics.

We have applied an optimization method in conjunction with numerical simulations to minimize the mixing time of a microfluidic mixer developed for protein folding studies. The optimization method uses a semideterministic algorithm to find the global minimum of the mixing time by varying the mixer geometry and flow conditions. We describe the minimization problem and constraints and give a brief overview of the optimization algorithm. We present results of the optimization, including the optimized geometry and parameter sensitivities, and we demonstrate the improvement in mixing performance with experiments using microfabricated mixers. The dye-quenching experiments of the original and optimized mixer designs show respective mixing times of 7 and 4 mus, a 40% reduction. The new design also provides more uniform mixing across streamlines that enter the mixer. The optimized mixer is the fastest reported continuous flow mixer for protein folding.

Kinetics↗

On-chip millionfold sample stacking using transient isotachophoresis.

We present a simple and robust isotachophoresis (ITP) method that can be integrated with microchip-based capillary electrophoresis (CE) devices to achieve millionfold sample stacking. We performed an experimental parametric study to show the effects of initial sample ion concentration, leading ion concentration, and trailing ion concentration on ITP stacking. We also discuss the usefulness and limitations of a simple one-dimensional nondispersive model and a scaling analysis for dispersion rate. We found that a single-column ITP configuration together with electroosmotic flow suppression and high leading ion concentration provide high-performance ITP and can be integrated readily with CE separation. We demonstrated detection of trace of 100 fM Alexa Fluor 488 (signal-to-noise ratio of 11) with a concentration increase of a factor of 2 x 10(6). Application of our ITP/CE protocol to the stacking and separation of negatively charged fluorescent tracers (Alexa Fluor 488 and bodipy) resulted in a concentration increase of 6.4 x 10(4) and a signal increase of 4.5 x 10(5). The ITP/CE protocol can be performed with a standard microchannel cross design or simple flow control. The method can be implemented with available off-the-shelf chip systems using off-the-shelf voltage control systems and buffer chemistries.

Journal Article↗

Electrokinetic transport in nanochannels. 2. Experiments.

We present an experimental study of nanoscale electrokinetic transport in custom-fabricated quartz nanochannels using quantitative epifluorescence imaging and current monitoring techniques. One aim is to yield insight into electrical double layer physics and study the applicability of continuum theory to nanoscale electrokinetic systems. A second aim is to explore a new separation modality offered by nanoscale electrophoretic separations. We perform parametric variations of applied electric field, channel depth, background buffer concentration, and species valence to impose variations on zeta potential, effective mobility, and Debye length among other parameters. These measurements were used to validate a continuum theory-based analytical model presented in the first of this two-paper series. Our results confirm the usefulness of continuum theory in predicting electrokinetic transport and electrophoretic separations in nanochannels. Our model leverages independent measurements of zeta potential performed in a microchannel system at electrolyte concentrations of interest. These data yield a zeta potential versus concentration relation that is used as a boundary condition for the nanochannel electrokinetic transport model. The data and model comparisons together show that the effective mobility governing electrophoretic transport of charged species in nanochannels depends not only on ion mobility values but also on the shape of the electric double layer and analyte ion valence. We demonstrate a method we term electrokinetic separation by ion valence, whereby both ion valence and mobility may be determined independently from a comparison of micro- and nanoscale transport measurements.

Electrochemistry↗

Electrokinetic transport in nanochannels. 1. Theory.

Electrokinetic transport in fluidic channels facilitates control and separation of ionic species. In nanometer-scale electrokinetic systems, the electric double layer thickness is comparable to characteristic channel dimensions, and this results in nonuniform velocity profiles and strong electric fields transverse to the flow. In such channels, streamwise and transverse electromigration fluxes contribute to the separation and dispersion of analyte ions. In this paper, we report on analytical and numerical models for nanochannel electrophoretic transport and separation of neutral and charged analytes. We present continuum-based theoretical studies in nanoscale channels with characteristic depths on the order of the Debye length. Our model yields analytical expressions for electroosmotic flow, species transport velocity, streamwise-transverse concentration field distribution, and ratio of apparent electrophoretic mobility for a nanochannel to (standard) ion mobility. The model demonstrates that the effective mobility governing electrophoretic transport of charged species in nanochannels depends not only on electrolyte mobility values but also on zeta potential, ion valence, and background electrolyte concentration. We also present a method we term electrokinetic separation by ion valence (EKSIV) whereby both ion valence and ion mobility may be determined independently from a comparison of micro- and nanoscale transport measurements. In the second of this two-paper series, we present experimental validation of our models.

Electrochemistry↗

Femtomole mixer for microsecond kinetic studies of protein folding.

We have developed a microfluidic mixer for studying protein folding and other reactions with a mixing time of 8 mus and sample consumption of femtomoles. This device enables us to access conformational changes under conditions far from equilibrium and at previously inaccessible time scales. In this paper, we discuss the design and optimization of the mixer using modeling of convective diffusion phenomena and a characterization of the mixer performance using microparticle image velocimetry, dye quenching, and Forster resonance energy-transfer (FRET) measurements of single-stranded DNA. We also demonstrate the feasibility of measuring fast protein folding kinetics using FRET with acyl-CoA binding protein.

Acyl Coenzyme A↗

Porous glass electroosmotic pumps: design and experiments.

An analytical model for electroosmotic flow rate, total pump current, and thermodynamic efficiency reported in a previous paper has been applied as a design guideline to fabricate porous-structure EO pumps. We have fabricated sintered-glass EO pumps that provide maximum flow rates and pressure capacities of 33 ml/min and 1.3 atm, respectively, at applied potential 100 V. These pumps are designed to be integrated with two-phase microchannel heat exchangers with load capacities of order 100 W and greater. Experiments were conducted with pumps of various geometries and using a relevant, practical range of working electrolyte ionic concentration. Characterization of the pumping performance are discussed in the terms of porosity, tortuosity, pore size, and the dependence of zeta potential on bulk ion density of the working solution. The effects of pressure and flow rate on pump current and thermodynamic efficiency are analyzed and compared to the model prediction. In particular, we explore the important tradeoff between increasing flow rate capacity and obtaining adequate thermodynamic efficiency. This research aims to demonstrate the performance of EOF pump systems and to investigate optimal and practical pump designs. We also present a gas recombination device that makes possible the implementation of this pumping technology into a closed-flow loop where electrolytic gases are converted into water and reclaimed by the system.

Journal Article↗

Porous glass electroosmotic pumps: theory.

This paper presents an analytical study of electroosmotic (EO) pumps with porous pumping structures. We have developed an analytical model to solve for electroosmotic flow rate, pump current, and thermodynamic efficiency as a function of pump pressure load for porous-structure EO pumps. The model uses a symmetric electrolyte approximation valid for the high-zeta-potential regime and numerically solves the Poisson-Boltzmann equation for charge distribution in the idealized pore geometry. Generalized scaling of pumping performance is discussed in the context of a parameterization that includes porosity, tortuosity, pore size, bulk ionic density, and the nonuniform conductivity distribution over charge layers. The model also incorporates an approximate ionic-strength-dependent zeta potential formulation.

Journal Article↗

On-chip coupling of isoelectric focusing and free solution electrophoresis for multidimensional separations.

We have developed an acrylic microfluidic device that sequentially couples liquid-phase isoelectric focusing (IEF) and free solution capillary electrophoresis (CE). Rapid separation (<1 min) and preconcentration (73x) of species were achieved in the initial IEF dimension. Using full-field fluorescence imaging, we observed nondispersive mobilization velocities on the order of 20 microm/s during characterization of the IEF step. This transport behavior allowed controlled electrokinetic mobilization of focused sample bands to a channel junction, where voltage switching was used to repeatedly inject effluent from the IEF dimension into an ampholyte-based CE separation. This second dimension was capable of analyzing all fluid volumes of interest from the IEF dimension, as IEF was 'parked' during each CE analysis and refocused prior to additional CE analyses. Investigation of each dimension of the integrated system showed time-dependent species displacement and band-broadening behavior consistent with IEF and CE, respectively. The peak capacity of the 2D system was approximately 1300. A comprehensive 2D analysis of a fluid volume spanning 15% of the total IEF channel length was completed in less than 5 min.

Algorithms↗

Thousandfold signal increase using field-amplified sample stacking for on-chip electrophoresis.

Field-amplified sample stacking (FASS) leverages conductivity gradients between a volume of injected sample and the background buffer to increase sample concentration. A major challenge in applying FASS to on-chip assays is the initial setup of high-conductivity gradient boundaries in the region of the injected sample volume. We have designed, fabricated, and characterized a novel FASS-capillary electrophoresis (CE) chip design that uses a photoinitiated porous polymer structure to facilitate sample injection and flow control for high-gradient FASS. This polymer structure provides a region of high flow resistance that allows the electromigration of sample ions. We have demonstrated an electropherogram signal increase by a factor of 1100 in electrophoretic separations of fluorescein and Bodipy with, respectively, 2 microM and 1 microM initial concentrations.

Electrophoresis, Capillary↗

Particle tracking techniques for electrokinetic microchannel flows.

We have applied particle tracking techniques to obtain spatially resolved velocity measurements in electrokinetic flow devices. Both micrometer-resolution particle image velocimetry (micro-PMV) and particle tracking velocimetry (PTV) techniques have been used to quantify and study flow phenomena in electrokinetic systems applicable to microfluidic bioanalytical devices. To make the flow measurements quantitative, we performed a series of seed particle calibration experiments. First, we measure the electroosmotic wall mobility of a borosilicate rectangular capillary (40 by 400 microm) using current monitoring. In addition to this wall mobility characterization, we apply PTV to determine the electrophoretic mobilities of more than 1,000 fluorescent microsphere particles in aqueous buffer solutions. Particles from this calibrated particle/ buffer mixture are then introduced into two electrokinetic flow systems for particle tracking flow experiments. In these experiments, we use micro-PIV, together with an electric field prediction, to obtain electroosmotic flow bulk fluid velocity measurements. The first example flow system is a microchannel intersection where we demonstrate a detailed documentation of the similitude between the electrical fields and the velocity fields in an electrokinetic system with uniform zeta potential, zeta. In the second system, we apply micro-PIV to a microchannel system with nonuniform zeta. The latter experiment provides a simultaneous measurement of two distinct wall mobilities within the microchannel.

Journal Article↗

Design and optimization of on-chip capillary electrophoresis.

We present a systematic, experimentally validated method of designing electrokinetic injections for on-chip capillary electrophoresis applications. This method can be used to predict point-wise and charge-coupled device (CCD)-imaged electropherograms using estimates of species mobilities, diffusivities and initial sample plug parameters. A simple Taylor dispersion model is used to characterize electrophoretic separations in terms of resolution and signal-to-noise ratio (SNR). Detection convolutions using Gaussian and Boxcar detector response functions are used to relate optimal conditions for resolution and signal as a function of relevant system parameters including electroosmotic mobility, sample injection length, detector length scale, and the length-to-detector. Analytical solutions show a tradeoff between signal-to-noise ratio and resolution with respect to dimensionless injection width and length to the detector. In contrast, there is no tradeoff with respect to the Peclet number as increases in Peclet number favor both SNR and separation solution (R). We validate our model with quantitative epifluorescence visualizations of electrophoretic separation experiments in a simple cross channel microchip. For the pure advection regime of dispersion, we use numerical simulations of the transient convective diffusion processes associated with electrokinetics together with an optimization algorithm to design a voltage control scheme which produces an injection plug that has minimal advective dispersion. We also validate this optimal injection scheme using fluorescence visualizations. These validations show that optimized voltage scheme produces injections with a standard deviation less than one-fifth of the width of the microchannel.

Diagnostic Imaging↗