Search PubMed⌕ Search

Biomedical subjects

Joshua J Rychak

Publications and source records attributed to Joshua J Rychak.

4 recordsLinked to original sources

Deformable gas-filled microbubbles targeted to P-selectin.

Ultrasound contrast microbubbles have been successfully targeted to a number of intravascular disease markers. We hypothesized that targeted delivery could be improved further, by making the microbubbles deformable, leading to increased microbubble-endothelium adhesion contact area and stabilized adhesion. Activated leukocytes utilize such strategy; they deform after binding to inflamed endothelium in the vasculature. Lipid-shell microbubbles were targeted to the endothelial inflammatory protein P-selectin with a monoclonal anti-P-selectin antibody attached to the microbubble shell. Deformable microbubbles were created by controlled pressurization with partial gas loss, which generated an average excess shell surface area of approximately 30% and the formation of outward-projected wrinkles and folds. Targeted microbubble adhesion and deformability were assessed in the parallel plate flow chamber under shear flow. Sustained adhesion of deformable microbubbles at wall shear stresses between 0.4 and 1.35 dyn/cm(2) was consistently better than adhesion of wrinkle-free microbubbles. Over this shear range, targeted wrinkled microbubbles were deformed by shear flow, unlike wrinkle-free microbubbles. In a murine cremaster inflammation model, a significant improvement of deformable microbubble targeting was observed by intravital microscopy. Overall, the mechanical aspects of adhesion, such as particle shape, deformability and surface microstructure, are important in engineering efficient site-targeted particle-based agents for medical imaging and therapy.

Animals↗

Acoustic radiation force enhances targeted delivery of ultrasound contrast microbubbles: in vitro verification.

Recent research has shown that targeted ultrasound contrast microbubbles achieve specific adhesion to regions of intravascular pathology, but not in areas of high flow. It has been suggested that acoustic radiation can be used to force free-stream microbubbles toward the target, but this has not been verified for actual targeted contrast agents. We present evidence that acoustic radiation indeed increases the specific targeted accumulation of microbubbles. Lipid microbubbles bearing an antibody as a targeting ligand were infused through a microcapillary flow chamber coated with P-selectin as the target protein. A 2.0 MHz ultrasonic pulse was applied perpendicular to the flow direction. Microbubble accumulation was observed on the flow chamber surface opposite the transducer. An acoustic pressure of 122 kPa enhanced microbubble adhesion up to 60-fold in a microbubble concentration range of 0.25 x 10(6) to 75 x 106) ml(-1). Acoustic pressure mediated the greatest adhesion enhancement at concentrations within the clinical dosing range. Acoustic pressure enhanced targeting nearly 80-fold at a wall shear rate of 1244 s(-1), suggesting that this mechanism is appropriate for achieving targeted microbubble delivery in high-flow vessels. Microbubble adhesion increased with the square of acoustic pressure between 25 and 122 kPa, and decreased substantially at higher pressures.

Antibodies↗

Binding and detachment dynamics of microbubbles targeted to P-selectin under controlled shear flow.

This study was performed to assess the binding kinetics of a targeted microbubble contrast agent exposed to shear stress. An ultrasound contrast targeted to P-selectin was designed by conjugating monoclonal antibodies against murine P-selectin (RB40.34) to the lipid monolayer shell of the microbubble using poly(ethylene glycol)-biotin-streptavidin. The attachment and detachment of targeted microbubbles to P-selectin immobilized on a culture dish were assessed in a parallel-plate flow chamber. Targeted microbubbles (5 x 10(6) particles/ml) drawn through the flow chamber coated with P-selectin (109 sites/microm(2)) at a shear stress of 0.3 dyn/cm(2) accumulated at a rate of 565 mm(-2) min(-1). Attachment rates increased at higher plate surface densities of P-selectin, and microbubble detachment was reduced. Accumulation rate first increased with shear stress, reached a maximum at approximately 0.6 dyn/cm(2) and then decreased. Control experiments on a plate that lacked P-selectin, or was blocked with mAb RB40.34, resulted in minimal bubble attachment. Microbubble detachment was tested by ramping up shear stress at 30-s intervals. Half-maximal detachment was reached at 34 dyn/cm(2). Overall, accumulation and retention of targeted ultrasound contrast agents is possible under physiologic flow conditions and is strongly influenced by shear stress and surface density of the target receptor.

Antibodies, Monoclonal↗

A novel method for measuring dynamic changes in cell volume.

Many cell types regulate their volume in response to extracellular tonicity changes through a complex series of adaptive mechanisms. Several methods that are presently used to measure cell volume changes include Coulter counters, fluorescent techniques, electronic impedance, and video microscopy. Although these methods are widely used and accepted, there are limitations associated with each technique. This paper describes a new method to measure changes in cell volume based on the principle that fluid flow within a rigid system is well determined. For this study, cos-7 cells were plated to line the inner lumen of a glass capillary and stimulated to swell or shrink by altering the osmolarity of the perfusing solution. The cell capillary was connected in series with a blank reference capillary, and differential pressure changes across each tube were monitored. The advantages of this method include 1) ability to continuously monitor changes in volume during rapid solution changes, 2) independence from cell morphology, 3) presence of physiological conditions with cell surface contacts and cell-cell interactions, 4) no phototoxic effects such as those associated with fluorescent methods, and 5) ability to report from large populations of cells. With this method, we could detect the previously demonstrated enhanced volume regulation of cells overexpressing the membrane phosphoprotein phospholemman, which has been implicated in osmolyte transport.

Animals↗