Indium microrod tags for electrochemical detection of DNA hybridization.

The preparation and advantages of indium microrod tracers for solid-state electrochemical detection of DNA hybridization are described. The cylindrical metal particles were prepared by a template-directed electrochemical synthetic route involving plating of indium into the pores of a host membrane. The linear relationship between the charge passed during the preparation and the resulting particle size allows tailoring of the sensitivity of the electrical DNA assay. The resulting micrometer-long rods thus offer a greatly lower detection limit (250 zmol), as compared to common bioassays' spherical nanoparticle tags. Indium offers a very attractive electrochemical stripping behavior and is not normally present in biological samples or reagents. Solid-state derivative-chronopotentiometric measurements of the indium tracer have been realized through a "magnetic" collection of the DNA-linked particle assembly onto a thick-film electrode transducer. Factors affecting the performance, including the preparation of the microrods and pretreatment of the transducer surface, were evaluated and optimized. The resulting protocol offers great promise for other affinity bioassays, as well as for electrical coding and identification (through the plating of different metal markers and of multimetal redox-encoded tags).

Base Pairing↗

Movable contactless-conductivity detector for microchip capillary electrophoresis.

A new movable contactless-conductivity detection system for microchip capillary electrophoresis is introduced. Such a versatile system relies on positioning the detector at different points along the separation channel via "sliding" the electrode holder. The new movable microchip detection system offers distinct improvements compared to common fixed-location conductivity detectors. For example, placing the detector at different locations along the microchannel offers useful insights into the separation process. Three-dimensional plots of resolution/channel length/separation voltage can be used for optimizing the separation process and selecting the analysis time. The system enables rapid switching between "total" (unresolved) and "individual" (resolved/fingerprint) signals on the basis of placing the detector at the beginning and end of the separation channel, respectively. By moving the detector to a shorter effective separation length, after eluting fast-migrating ions, shorter analysis times can be achieved (through faster detection of late-eluting analytes). These and other improvements in the analytical performance and insights into the separation process are illustrated in connection with the detection of low-energy ionic explosives and nerve agent degradation products.

Journal Article↗

Encoded beads for electrochemical identification.

Encoded redox beads, based on the encapsulation of different quantum dots (QD) within polystyrene microspheres, have been developed for electrochemical identification. Encoded redox rods, prepared by sequential plating of different metal tracers into the pores of a host membrane, have also been designed. By incorporating different predetermined levels of multiple metal markers, such redox-encoded particles lead to a large number of recognizable voltammetric signatures and, hence, offer great promise for covert tagging of commercial products. The resulting voltammetric signatures correlate well with the predetermined loading ratio, indicating a reproducible encapsulation process. As desired for effective authenticity testing, QD-based "identification layers" were reproducibly cast and removed from packages of commercial products to display their distinct voltammetric profiles. Factors affecting the preparation of such identification layers were optimized.

Journal Article↗

On-chip integration of enzyme and immunoassays: simultaneous measurements of insulin and glucose.

A microfluidic device coupling immunological and enzymatic assays within a single microchannel has been developed for simultaneous measurements of insulin and glucose. Such a dual-mode (enzyme/immuno) protocol involves precolumn reactions of insulin and glucose with the enzyme-labeled anti-human insulin and glucose-dehydrogenase/NAD+, respectively, followed by the electrophoretic separation of the free antibody, antibody-antigen complex, and the NADH product of the enzymatic reaction. The separation is followed by a postcolumn reaction of the alkaline-phosphatase tracer with the p-NPP substrate and a downstream amperometric detection of the p-nitrophenol and NADH products. Despite the huge concentration difference [millimolar (glucose) and nanomolar (insulin)] and the use of different assay principles, the new biochip responds independently to the corresponding target analytes, with linear dynamic ranges over their clinically relevant ranges. Complete assays, carried out within less than 4 min, lead to good precision (RSD 0.36%) for the insulin/glucose ratio. The resulting biochip allows simultaneous testing for insulin and glucose to be performed more rapidly, easily, and economically, and hence it holds great promise for improved management of diabetes.

Antibodies↗

Carbon nanotube/teflon composite electrochemical sensors and biosensors.

The fabrication and attractive performance of carbon nanotube (CNT)/Teflon composite electrodes, based on the dispersion of CNT within a Teflon binder, are described. The resulting CNT/Teflon material brings new capabilities for electrochemical devices by combining the advantages of CNT and "bulk" composite electrodes. The electrocatalytic properties of CNT are not impaired by their association with the Teflon binder. The marked electrocatalytic activity toward hydrogen peroxide and NADH permits effective low-potential amperometric biosensing of glucose and ethanol, respectively, in connection with the incorporation of glucose oxidase and alcohol dehydrogenase/NAD(+) within the three-dimensional CNT/Teflon matrix. The accelerated electron transfer is coupled with minimization of surface fouling and surface renewability. These advantages of CNT-based composite devices are illustrated from comparison to their graphite/Teflon counterparts. The influence of the CNT loading upon the amperometric and voltammetric data, as well as the electrode resistance, is examined. SEM images offer insights into the nature of the CNT/Teflon surface. The preparation of CNT/Teflon composites overcomes a major obstacle for creating CNT-based biosensing devices and expands the scope of CNT-based electrochemical devices.

Biosensing Techniques↗

Microscale solid-phase extraction system for explosives.

A simple, semi-automated, microcolumn solid-phase extraction (SPE) system is optimized for the extraction, preconcentration and HPLC analysis of seven different explosives and explosive derivatives contaminating seawater, river water and well water samples. The microcolumns were constructed from 1/16 in. O.D. PTFE tubing (1 in.=2.54 cm) packed with 0.5-1.5 mg of SPE material. LiChrolut EN or Porapak R. The extraction system consisted of two syringe pumps and several solenoid valves. Optimal detection limits were realized when the sample water flow-rate was maximally increased within the limits of the pump, 5-10 ml/min (despite exceeding the breakthrough threshold of the SPE microcolumn), and when the eluate volume collected from the column was minimized, <5 microl (despite very low recovery percentages).

Automation↗

Electrochemical coding technology for simultaneous detection of multiple DNA targets.

Nucleic-acid hybridization assays based on the use of different inorganic-colloid (quantum dots) nanocrystal tracers for the simultaneous electrochemical measurements of multiple DNA targets are described. Three encoding nanoparticles (zinc sulfide, cadmium sulfide, and lead sulfide) are used to differentiate the signals of three DNA targets in connection to stripping-voltammetric measurements of the heavy metal dissolution products. These products yield well-defined and resolved stripping peaks at -1.12 V (Zn), -0.68 V (Cd), and -0.53 V (Pb) at the mercury-coated glassy-carbon electrode (vs Ag/AgCl reference). The position and size of these peaks reflect the identity and level of the corresponding DNA target. The multi-target detection capability is coupled to the amplification feature of stripping voltammetry (to yield femtomole detection limits) and with an efficient magnetic removal of nonhybridized nucleic acids to offer high sensitivity and selectivity. The protocol is illustrated for the simultaneous detection of three DNA sequences related to the BCRA1 breast-cancer gene in a single sample in connection to magnetic beads bearing the corresponding oligonucleotide probes. The new electrochemical coding is expected to bring new capabilities for DNA diagnostics, and for bioanalysis, in general.

Breast Neoplasms↗

Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors.

The ability to solubilize single-wall and multiwall carbon nanotubes (CNT) in the presence of the perfluorinated polymer Nafion is described. Such use of Nafion as a solubilizing agent for CNT overcomes a major obstacle for creating CNT-based biosensing devices. Their association with Nafion does not impair the electrocatalytic properties of CNT. The resulting CNT/Nafion modified glassy-carbon electrodes exhibit a strong and stable electrocatalytic response toward hydrogen peroxide. The marked acceleration of the hydrogen peroxide redox process is very attractive for the operation of oxidase-based amperometric biosensors, as illustrated for the highly selective low-potential (-0.05 V vs Ag/AgCl) biosensing of glucose. These findings open the door for using CNT in a wide range of chemical sensors and nanoscale electronic devices.

Biosensing Techniques↗

Microchip capillary electrophoresis coupled with a boron-doped diamond electrode-based electrochemical detector.

The attractive behavior and advantages of a diamond electrode detector for a micromachined capillary electrophoresis (CE) system are discussed. A chemically vapor-deposited boron-doped diamond (BDD) film band (0.3 x 6.0 mm) electrode is used for end-column amperomettic detection. The favorable performance of the diamond electrode microchip detector is indicated from comparison to a commonly used thick-film carbon detector. The diamond electrode offers enhanced sensitivity, lower noise levels, and sharper peaks for several groups of important anaytes (nitroaromatic explosives, organophosphate nerve agents, phenols). The favorable signal-to-background characteristics of the BDD-based CE detector are coupled with a greatly improved resistance to surface fouling and greater isolation from high separation voltages. The enhanced stability is indicated from a RSD of 0.8% for 60 repetitive measurements of 5 ppm 2,4,6-trinitrotoluene (vs RSD of 10.8% at the thick-film carbon electrode). A highly linear response is obtained for the explosives 1,3-dinitrobenzene and 2,4-dinitrotoluene over the 200-1,400 ppb range, with detection limits of 70 and 110 ppb, respectively. Factors influencing the performance of the BDD detector are assessed and optimized. The attractive properties of BDD make it very promising material for electrochemical detection in CE microchip systems and other micromachined flow analyzers.

Air Pollutants, Occupational↗

Application of diamond microelectrodes for end-column electrochemical detection in capillary electrophoresis.

Highly boron-doped diamond microelectrodes were employed in an end-column electrochemical detector for capillary electrophoresis (CE). The diamond microline electrodes were fabricated from conducting diamond thin films (exposed surface area, 300 x 50 microm), and their analytical performance as CE detectors was evaluated in a laboratory-made CE installation. The CE-ED system exhibited high separation efficiency for the detection of several catecholamines, including dopamine (DA), norepinephrine (NE), and epinephrine (E), with excellent analytical performance, for example, 155,000 theoretical plates for DA. The diamond-based electrochemical detection system also displayed low detection limits (approximately 20 nM for E at S/N = 3) and a highly reproducible current response with 10 repetitive injections of mixed analytes containing DA, NE, and E (each 50 microM), with relative standard deviations (RSD) of approximately 5%. The performance of the diamond detector in CE was also evaluated in the detection of chlorinated phenols (CP). When compared to the carbon fiber microelectrode, the diamond electrode exhibited lower detection limits in an end-column CE detection resulting from very low noise levels and highly reproducible analyses without electrode polishing due to analyte fouling, which makes it possible to perform easier and more stable CE analysis.

Journal Article↗

Microfabricated electrophoresis chip for bioassay of renal markers.

A novel capillary electrophoresis chip-based detection system for simultaneous measurements of the renal markers creatine, creatinine, p-aminohippuric acid, and uric acid is described. Fluid control is used for mixing the sample with the enzymes creatininase (CA), creatinase (CI), and sarcosine oxidase (SOx) and for separating the neutral hydrogen peroxide end product from the anionic p-aminohippuric and urate species. The 'total' (creatinine and creatine) signal was measured with the running buffer containing all three enzymes, while the creatine signal alone was recorded by mixing the sample with the CI-SOx solution. Creatinine concentrations are measured by comparing the response in the presence and absence of CA. The peroxide product and the oxidizable p-aminohippuric and uric acids are detected electrochemically at a downstream gold-coated thick-film amperometric detector. The four renal markers are readily measured within 5 min, while creatinine/creatine within less than 2 min. Factors influencing the performance, including the level of three enzymes, separation voltage, and detection potential, are optimized. Applicability to urine samples is demonstrated. Such a multianalyte microchip detection device would allow renal function testing to be performed more rapidly, easily, and economically in the point-of-care setting.

Biomarkers↗

Nonaqueous electrophoresis microchip separations: conductivity detection in UV-absorbing solvents.

The use of organic solvents in microfabricated capillary electrophoresis (CE) devices is demonstrated in connection with the separation of aliphatic amines in pure dimethylformamide, dimethylacetamide, dimethyl sulfoxide, or propylene carbonate media. Contactless conductivity detection is employed for monitoring the separated solutes in these UV-absorbing solvents. The effect of the physicochemical properties of the organic solvent upon the migration behavior is investigated. The apparent mobility increases nearly linearly with the reciprocal of the solvent viscosity, while the electroosmotic mobility increases in a linear fashion with the dielectric constant/ viscosity ratio. Some deviation from theoretical predictions is observed using propylene carbonate. The nonaqueous CE microchip offers high separation efficiency, reflected in plate numbers ranging from 93,680 to 127,680, using a separation voltage of +3,000 V, a dimethylformamide medium, and a contactless conductivity detection. Experimental parameters affecting the analytical performance of the nonaqueous CE/conductivity microchip are examined. Calibration and precision experiments indicate a linear and reproducible response. Such use of organic solvents can benefit microchip separations through extended scope (toward nonpolar solutes) and tunable selectivity.

Journal Article↗

Electrophoretic microchip with dual-opposite injection for simultaneous measurements of anions and cations.

A novel dual-injection poly(methylmethacrylate) (PMMA) microchip electrophoretic system has been designed and fabricated for simultaneous measurements of anions and cations using a single channel and detection device. It consists of two sample reservoirs, on both sides of a common separation channel. Anions and cations can be simultaneously electrokinetically injected into both ends of the separation channel. Due to lower electroosmotic flow in polymer channels compared to glass ones, the cations and anions migrate in opposite directions and can be separated from each other and detected using a movable contactless conductivity detector (MCCD) positioned around the center of the separation channel. The effects of the detector position and of the separation voltage on the response and resolution have been studied and optimized for simultaneous determination of six low-energy explosive-related ions, including ammonium, methyl ammonium, sodium, chloride, nitrate, and perchlorate in a single analytical run (of ca. 3 min). Simultaneous detection of nerve-agent degradation products along with explosive-related anions and cations is also demonstrated. The versatile system can also be used for separately measuring anions or cations. The attractive behavior of the dual-opposite injection microchip offers great promise for a wide range of applications, including "total ion analysis" of various samples.

Anions↗

Flow injection amperometric detection of OP nerve agents based on an organophosphorus-hydrolase biosensor detector.

A flow-injection system with an organophosphorus-hydrolase (OPH)-biosensor detector has been developed and characterized for the rapid detection of organophosphorus (OP) nerve agents. The enzyme was immobilized onto a thin-film gold detector through a cystamine-glutaraldehyde coupling. Factors influencing the performance were optimized. The resulting flow system offered a fast, sensitive, selective, and stable response. The peak current increased linearly with the concentration of paraoxon and methyl parathion over the 1-10 microM range (sensitivity, 2.29 and 1.04 nA/microM, respectively). The OPH-biosensor flow injection systems offered low detection limits (e.g. 0.1 microM paraoxon), along with a good precision (R.S.D. of 3.6% for 20 successive injections of a 1.0 microM paraoxon solution). The OPH-biosensor flow detector offers great promise for rapid field screening of OP pesticides and nerve agents.

Aryldialkylphosphatase↗

Carbon-nanotube-modified glassy carbon electrodes for amplified label-free electrochemical detection of DNA hybridization.

The preparation and attractive performance of carbon-nanotube modified glassy-carbon (CNT/GC) electrodes for improved detection of purines, nucleic acids, and DNA hybridization are described. The surface-confined multiwall carbon-nanotube (MWCNT) facilitates the adsorptive accumulation of the guanine nucleobase and greatly enhances its oxidation signal. The advantages of CNT/GC electrodes are illustrated from comparison to the common unmodified glassy carbon, carbon paste and graphite pencil electrodes. The dramatic amplification of the guanine signal has been combined with a label-free electrical detection of DNA hybridization. Factors influencing the enhancement of the guanine signal are assessed and optimized. The performance characteristics of the amplified label-free electrochemical detection of DNA hybridization are reported in connection to measurements of nucleic-acid segments related to the breast-cancer BRCA1 gene.

Animals↗

Enzyme-dispersed carbon-nanotube electrodes: a needle microsensor for monitoring glucose.

The preparation of an enzyme-dispersed carbon-nanotube (CNT) electrode, based on mixing glucose oxidase (GOx) within CNT, is described. The new binderless biocomposite was packed within a 21-gauge needle and used for amperometric monitoring of glucose. The resulting microsensor offers a low-potential highly selective and sensitive detection of glucose. The high sensitivity and selectivity are coupled to a wide linear range, prolonged lifetime and oxygen independence. About 80% of the GOx activity is retained during a 24 h thermal stress at 90 degrees C, reflecting the enzyme-stabilization action of CNT. The marked electrocatalytic action towards hydrogen peroxide allows highly selective detection of the glucose substrate at -0.1 V (vs. Ag/AgCl) with no interferences from coexisting ascorbic acid, acetaminophen or uric acid. Linearity prevails up to 40 mM glucose (with analytically useful signals observed up to 0.1 M). Factors affecting the performance of the CNT-based glucose biosensor were assessed and optimized. The attractive performance of the new needle electrode offers great promise for continuous monitoring of glucose in connection to the management of diabetes, and for the biosensing of other metabolites.

Electrochemistry↗

Dual conductivity/amperometric detection system for microchip capillary electrophoresis.

The performance characteristics and advantages of a new dual electrochemical microchip detection system based on simultaneous conductivity and amperometric measurements are described. The system relies on the combination of a contactless conductivity detector with an end-column thick-film amperometric detector. Such coupling of the conductivity and amperometric detection modes in a single separation channel greatly enhances the sample characterization to offer simultaneous measurements of both ionic and electroactive species, improved reproducibility, and confirmation of peak identity. The simultaneous measurement of nitroaromatic and ionic explosives is used for demonstrating the ability to detect both electroactive and ionic species. Major improvements are also observed for analytes responding at both detectors. For example, the generation of dual response ratios can be used to improve the reproducibility and confirm the peak identity/integrity. Such dual response ratios reflect the distinct redox and conductivity properties of the individual analytes. The independence of the two detectors is reflected in the absence of "cross-talk" effects. The behavior of the dual detector is comparable with those of the individual detectors. Such a dual electrochemical detection system is easy to implement and requires inherently portable low-cost instrumentation.

Aminophenols↗

Measurements of chemical warfare agent degradation products using an electrophoresis microchip with contactless conductivity detector.

This paper reports on a microfluidic device for the screening of organophosphonate nerve agent degradation products. The miniaturized system relies on an efficient chip-based separation of alkyl methylphosphonic acids (breakdown products of Sarin, Soman, and VX nerve agents) followed by their sensitive contactless conductivity detection. Experimental parameters relevant to the separation and detection processes have been optimized to yield high sensitivity (with 48-86 microg L(-1) detection limits), fast response (50 s for a three alkyl methylphosphonic acid mixture), high precision (RSD = 3.8-5.0%), and good linearity (over the 0.3-100 mg L(-1) range). Applicability to natural (river) water samples is demonstrated. The new microsystem offers promise for monitoring degradation products of chemical warfare agents, with advantages of speed/warning, efficiency, portability, sample size, and cost compared to conventional ion chromatography or capillary electrophoresis systems.

Chemical Warfare Agents↗