Search PubMed⌕ Search

Biomedical subjects

Joseph R Lakowicz

Publications and source records attributed to Joseph R Lakowicz.

At least 55 records · Page 3Linked to original sources

Metal-enhanced fluorescence: an emerging tool in biotechnology.

Over the past 15 years, fluorescence has become the dominant detection/sensing technology in medical diagnostics and biotechnology. Although fluorescence is a highly sensitive technique, where single molecules can readily be detected, there is still a drive for reduced detection limits. The detection of a fluorophore is usually limited by its quantum yield, autofluorescence of the samples and/or the photostability of the fluorophores; however, there has been a recent explosion in the use of metallic nanostructures to favorably modify the spectral properties of fluorophores and to alleviate some of these fluorophore photophysical constraints. The use of fluorophore-metal interactions has been termed radiative decay engineering, metal-enhanced fluorescence or surface-enhanced fluorescence.

Biotechnology↗

Myoglobin immunoassay based on metal particle-enhanced fluorescence.

Enhanced fluorescence on silver island films (SIFs) is utilized to develop a sandwich-format immunoassay for the cardiac marker myoglobin (Myo). Myoglobin was first captured on surfaces coated with anti-Myo antibodies; the surface was then incubated with fluorescently labeled anti-Myo antibodies. The system was examined on glass surfaces and on SIFs. We observed the enhancement of the signal from SIFs in the range of 10-15-fold if compared to the signal from the glass substrate not modified with a SIF. A kinetic immunoassay for Myo on SIF-modified surface results in a decreased background signal. The initial results show that it is possible to detect Myoglobin concentrations below 50 ng/mL, which is lower than clinical cut-off for Myoglobin in healthy patients. We suggest the use of SIF-modified substrates for increasing the sensitivity of surface assays with fluorescence detection.

Antibodies, Monoclonal↗

Metal-enhanced fluorescence immunoassays using total internal reflection and silver island-coated surfaces.

We present a generic immunoassay platform that uses enhanced total internal reflection fluorescence in the proximity of silver island films (SIFs), a surface coating consisting of metal (silver) particles. This platform is used with a model immunoassay where a protein antigen, rabbit immunoglobulin G, was immobilized on the SIF-coated glass surface. The signal from a fluorescent dye-labeled anti-rabbit antibody binding to the surface antigen was detected; different color dyes have been tested. Close placement of the fluorophore to surface-bound silver nanostructures results in dramatic signal enhancement (up to 40-fold) on the SIFs as compared with the glass slides. Use of the total internal reflection mode of excitation has significant advantages (over classic front-face excitation) for practical assay development. The limited evanescent wave excitation volume makes it possible to minimize the background signal and use the immunoassay with no need for any washing steps.

Antibodies↗

Myoglobin immunoassay utilizing directional surface plasmon-coupled emission.

We described an immunoassay for the cardiac marker myoglobin on a thin silver mirror surface using surface plasmon-coupled emission (SPCE). SPCE occurs for fluorophores in proximity (within approximately 200 nm) of a thin metal film (in our case, silver) and results in a highly directional radiation through a glass substrate at a well-defined angle from the normal axis. We used the effect of SPCE to develop a myoglobin immunoassay on the silver mirror surface deposited on a glass substrate. Binding of the labeled anti-myoglobin antibodies led to the enhanced fluorescence emission at a specific angle of 72 degrees . The directional and enhanced directional fluorescence emission enables detection of myoglobin over a wide range of concentrations from subnormal to the elevated level of this cardiac marker. Utilizing SPCE allowed us also to demonstrate significant background suppression (from serum or whole blood) in the myoglobin immunoassay. We expect SPCE to become a powerful technique for performing immunoassays for many biomarkers in surface-bound assays.

Immunoassay↗

Complexation of polysaccharide and monosaccharide with thiolate boronic acid capped on silver nanoparticle.

Synthesized thiolate boronic acid was found to complex with both a polysaccharide (dextran) and a monosaccharide (glucose) with similar affinities but displayed more affinity with dextran than with glucose when capped as a ligand on silver nanoparticle. Coupling on multiple sites of dextran, the silver particles were aggregated. The aggregated particles displayed a decrease of absorbance at 397 nm and an increase at 640 nm. Luminescence intensity displayed an upward deviation increase with the concentration of dextran. The luminescence spectral change was ascribed to surface-enhanced fluorescence by the enhanced field from the aggregated metallic particles.

Boronic Acids↗

Ultrabright fluorescein-labeled antibodies near silver metallic surfaces.

Fluorescein-labeled antibodies are widely used in clinical assays and fluorescence microscopy. The fluorescent signal per labeled antibody is limited by fluorescein self-quenching, which occurs when the antibody is heavily labeled with multiple fluoresceins. We examined immunoglobulin G (IgG) when labeled with 0.7 to about 30 fluoresceins per antibody molecule. The extent of self-quenching was decreased, and the signal increased, when the labeled antibody was in close proximity to metallic silver particles. Time-resolved measurements showed that the intensity increase was due in part to a silver-induced increase in the radiative decay rate. These results suggest the use of labeled antibodies conjugated to silver particles as ultrabright probes for imaging or analytical applications.

Antibodies↗

Ultraviolet surface plasmon-coupled emission using thin aluminum films.

Surface plasmon-coupled emission (SPCE) is the directional radiation of light into a substrate due to excited fluorophores above a thin metal film. To date, SPCE has only been observed with visible wavelengths using silver or gold films. We now show that SPCE can be observed in the ultraviolet region of the spectrum using thin (20 nm) aluminum films. We observed directional emission in a quartz substrate from the DNA base analogue 2-aminopurine (2-AP). The SPCE radiation occurs within a narrow angle at 59 degrees from the normal to the hemicylindrical prism. The excitation conditions precluded the creation of surface plasmons by the incident light. The directional emission at 59 degrees is almost completely p-polarized, consistent with its origin from surface plasmons due to coupling of excited 2-AP with the aluminum. The emission spectra and lifetimes of the SPCE are those characteristic of 2-AP. Different emission wavelengths radiate at slightly different angles on the prism providing intrinsic spectral resolution from the aluminum film. These results indicate that SPCE can be used with numerous UV-absorbing fluorophores, suggesting biochemical applications with simultaneous surface plasmon resonance and SPCE binding assays.

2-Aminopurine↗

Nanogold-plasmon-resonance-based glucose sensing.

Noble metal nanoparticles are well known for their strong interactions with light through the resonant excitations of the collective oscillations of the conduction electrons on the particles, the so-called surface plasmon resonances. The close proximity of two nanoparticles is known to result in a red-shifted resonance wavelength peak, due to near-field coupling. We have subsequently employed this phenomenon and developed a new approach to glucose sensing, which is based on the aggregation and disassociation of 20-nm gold particles and the changes in plasmon absorption induced by the presence of glucose. High-molecular-weight dextran-coated nanoparticles are aggregated with concanavalin A (Con A), which results in a significant shift and broadening of the gold plasmon absorption. The addition of glucose competitively binds to Con A, reducing gold nanoparticle aggregation and therefore the plasmon absorption when monitored at a near-red arbitrary wavelength. We have optimized our plasmonic-type glucose nanosensors with regard to particle stability, pH effects, the dynamic range for glucose sensing, and the observation wavelength to be compatible with clinical glucose requirements and measurements. In addition, by modifying the amount of dextran or Con A used in nanoparticle fabrication, we can to some extent tune the glucose response range, which means that a single sensing platform could potentially be used to monitor microM --> mM glucose levels in many physiological fluids, such as tears, blood, and urine, where the glucose concentrations are significantly different.

Biosensing Techniques↗

Oligonucleotide-displaced organic monolayer-protected silver nanoparticles and enhanced luminescence of their salted aggregates.

N-(2-mercaptopropionyl)glycine (tiopronin) monolayer-protected silver particles were partially displaced by single-stranded oligonucleotides through ligand exchanges. The oligonucleotide-displaced particles could be hybridized with complementary fluorophore-labeled oligonucleotides. Both the oligonucleotide-displaced and hybridized particles could be aggregated by electrostatic interactions with salt in buffer solution, and the aggregates displayed enhanced luminescence from fluorophores. This result suggests the possible application of surface-enhanced fluorescence from metallic nanoparticle aggregation for DNA detection.

DNA↗

Fluorescence spectral properties of labeled thiolated oligonucleotides bound to silver particles.

We examined the fluorescent spectral properties of fluorescein-labeled DNA oligomers when directly bound to metallic silver particles via a terminal sulfhydryl group. We found a 12-fold increase in fluorescence intensity and 25-fold decrease in lifetime for a fluorescein residue positioned 23 nucleotides from the silver surface compared to labeled oligomers in free solution. Similar results were found for a 23-mer labeled with five fluorescein residues. The absence of long lifetime components in the intensity decays suggests that all labeled oligomers are bound to silver and affected similarly by the metallic surfaces. These results provide the basic knowledge needed to begin use of metal-enhanced fluorescence for the detection of target sequences in simple formats potentially without a washing separation step. The use of metal-enhanced fluorescence provides a generic approach to obtaining a hybridization-dependent increase in fluorescence with most, if not all, commonly used fluorophores.

Oligonucleotides↗

Ophthalmic glucose sensing: a novel monosaccharide sensing disposable and colorless contact lens.

We have developed a technology for continuous tear glucose monitoring, and therefore potentially blood glucose monitoring, using a daily use, disposable contact lens embedded with sugar-sensing boronic acid containing fluorophores. The novelty of our approach is two fold. Firstly, the notion of sensing extremely low glucose concentrations in tears by our approach, and secondly, the unique compatibility of our new probes with the internal environment of the disposable, off-the-shelf, contact lenses, chosen because the physiological compatibility of disposable plastic contact lenses has already been assessed and optimized with regard to vision correction, size and oxygen/analyte permeability. Our findings show that our approach is indeed suitable for the continuous monitoring of tear glucose levels in the concentration range (50-500 microM), which track blood glucose levels which are approximately 5-10 fold higher. We believe our approach offers unique opportunities for non-invasive continuous glucose monitoring for diabetics, especially since many have eye disorders and require vision correction by either contact lenses or glasses, which is thought to be due to glycation of protein in blood vessels.

Boronic Acids↗

Excitation and emission wavelength ratiometric cyanide-sensitive probes for physiological sensing.

We characterize three new fluorescent probes that show both spectral shifts and intensity changes in the presence of aqueous cyanide, allowing for both excitation and fluorescence emission wavelength ratiometric and colorimetric sensing. The relatively high binding constants of the probes for cyanide enables a distinct colorimetric change to be visually observed with as little as 10 microM cyanide. The response of the new probes is based on the ability of the boronic acid group to interact with the CN(-) anion, changing from the neutral form of the boronic acid group R-B(OH)(2) to the anionic R-B(-)(OH)3 form, which is an electron-donating group. The presence of an electron-deficient quaternary heterocyclic nitrogen center and a strong electron-donating amino group in the 6 position on the quinolinium backbone provides for the spectral changes observed upon CN(-) complexation. We have determined the binding constants for the ortho-, meta-, and para-boronic acid probes to be 0.12, 0.17, and 0.14 microM(-3). In addition we have synthesized a control compound that does not contain the boronic acid moiety, allowing for structural comparisons and a rationale for the sensing mechanism to be made. Finally we show that the affinity for monosaccharides, such as glucose or fructose, is relatively low as compared to that for cyanide, enabling the potential detection of cyanide in physiologies up to lethal levels.

Biosensing Techniques↗

Noninvasive continuous monitoring of physiological glucose using a monosaccharide-sensing contact lens.

We have tested the feasibility of tear glucose sensing using a daily, disposable contact lens embedded with boronic acid-containing fluorophores as a potential alternative to current invasive glucose-monitoring techniques. Our findings show that our approach may, indeed, be suitable for the continuous monitoring of tear glucose levels in the range 50-500 microM, which track blood glucose levels that are approximately 5-10-fold higher. We compare the response of the boronic acid probes in the contact lens to solution-based measurements and can conclude that both the pH and polarity within the contact lens need to be considered with respect to choosing/designing and optimizing glucose-sensing probes for contact lenses.

Biosensing Techniques↗

Multi-wavelength immunoassays using surface plasmon-coupled emission.

We describe a new method for multi-wavelength immunoassays using surface plasmon-coupled emission (SPCE). This phenomenon is coupling of excited fluorophores with a nearby thin metal film, in our case silver, resulting in strongly directional emission into the underlying glass substrate. The angle at which the radiation propagate through the prism depends on the surface plasmon angle for the relevant wavelength. These angles depend on emission wavelength, allowing measurement of multiple analytes using multiple emission wavelengths. We demonstrated this possibility using antibodies labeled with either Rhodamine Red-X or AlexaFluor 647. These antibodies were directed against an antigen protein bound to the silver surface. The emission from each labeled antibody occurred at a different angle on the glass prism, allowing independent measurement of surface binding of each antibody. This method of SPCE immunoassays can be readily extended to 4 or more wavelengths.

Animals↗

Radiative decay engineering 4. Experimental studies of surface plasmon-coupled directional emission.

Fluorescence is typically isotropic in space and collected with low efficiency. In this paper we describe surface plasmon-coupled emission (SPCE), which displays unique optical properties and can be collected with an efficiency near 50%. SPCE occurs for fluorophores within about 200 nm of a thin metallic film, in our case a 50-nm-thick silver film on a glass substrate. We show that fluorophore proximity to this film converts the normally isotropic emission into highly directional emission through the glass substrate at a well-defined angle from the normal axis. Depending on the thickness of the polyvinyl alcohol (PVA) film on the silver, the coupling efficiency of sulforhodamine 101 in PVA ranged from 30 to 49%. Directional SPCE was observed whether the fluorophore was excited directly or by the evanescent field due to the surface plasmon resonance. The emission is always polarized perpendicular to the plane of incidence, irrespective of the polarization of the incident light. The lifetimes are not substantially changed, indicating a mechanism somewhat different from that observed previously for the effects of silver particles on fluorophores. Remarkably, the directional emission shows intrinsic spectral resolution because the coupling angles depend on wavelength. The distances over which SPCE occurs, 10 to 200 nm, are useful because a large number of fluorophores can be localized within this volume. The emission of more distant fluorophores does not couple into the glass, allowing background suppression from biological samples. SPCE can be expected to become rapidly useful in a variety of analytical and medical sensing applications.

Fluorescence↗

Radiative decay engineering 3. Surface plasmon-coupled directional emission.

A new method of fluorescence detection that promises to increase sensitivity by 20- to 1000-fold is described. This method will also decrease the contribution of sample autofluorescence to the detected signal. The method depends on the coupling of excited fluorophores with the surface plasmon resonance present in thin metal films, typically silver and gold. The phenomenon of surface plasmon-coupled emission (SPCE) occurs for fluorophores 20-250 nm from the metal surface, allowing detection of fluorophores over substantial distances beyond the metal-sample interface. SPCE depends on interactions of the excited fluorophore with the metal surface. This interaction is independent of the mode of excitation; that is, it does not require evanescent wave or surface-plasmon excitation. In a sense, SPCE is the inverse process of the surface plasmon resonance absorption of thin metal films. Importantly, SPCE occurs over a narrow angular distribution, converting normally isotropic emission into easily collected directional emission. Up to 50% of the emission from unoriented samples can be collected, much larger than typical fluorescence collection efficiencies near 1% or less. SPCE is due only to fluorophores near the metal surface and may be regarded as emission from the induced surface plasmons. Autofluorescence from more distal parts of the sample is decreased due to decreased coupling. SPCE is highly polarized and autofluorescence can be further decreased by collecting only the polarized component or only the light propagating with the appropriate angle. Examples showing how simple optical configurations can be used in diagnostics, sensing, or biotechnology applications are presented. Surface plasmon-coupled emission is likely to find widespread applications throughout the biosciences.

Fluorescence↗

Immunoassays based on directional surface plasmon-coupled emission.

We described a new approach to immunoassays using surface plasmon-coupled emission (SPCE). Fluorescence is visually isotropic in space, so that the sensitivity is limited in part by the light collection efficiency. By the use of SPCE, we can efficiently collect the emission and convert it to a cone-like directional beam in a glass substrate. SPCE is the coupling of excited fluorophores with a thin metal film, resulting in radiation of surface plasmons into the higher refractive index media. We used SPCE to develop a model affinity assay using labeled goat anti-rabbit immunoglobulin G (IgG) antibodies against rabbit IgG bound to a 50-nm-thick silver film. Binding of labeled IgG to the surface resulted in increased intensity observed at an angle of 75 degrees from the normal in the glass substrate. The SPCE intensity depends on proximity of the fluorophore to the silver film and does not require a change in quantum yield upon binding. The use of SPCE is shown to provide background suppression because excited fluorophores distant from the silver film do not result in SPCE. Sensitivity and selectivity can be further increased by excitation under conditions of surface plasmon resonance (SPR) because the evanescent field is enhanced by the resonance interaction and excitation is limited to the region near the metal. We believe SPCE will provide a new technology for high sensitivity and selectivity in surface-bound assays and microfluidic systems.

Animals↗

Roughened silver electrodes for use in metal-enhanced fluorescence.

Roughened silver electrodes are widely used for surface-enhanced Raman scattering (SERS). We tested roughened silver electrodes for metal-enhanced fluorescence. Constant current between two silver electrodes in pure water resulted in the growth of fractal-like structures on the cathode. This electrode was coated with a monolayer of human serum albumin (HSA) protein that had been labeled with a fluorescent dye, indocyanine green (ICG). The fluorescence intensity of ICG-HSA on the roughened electrode increased by approximately 50-fold relative to the unroughened electrode, which was essentially non-fluorescent and increased typically two-fold as compared to the silver anode. No fractal-like structures were observed on the anode. Lifetime measurements showed that at least part of the increased intensity was due to an increased radiative decay rate of ICG. In our opinion, the use of in situ generated roughened silver electrodes will find multifarious applications in analytical chemistry, such as in fluorescence based assays, in an analogous manner to the now widespread use of SERS. To the best of our knowledge this is the first report of roughened silver electrodes for metal-enhanced fluorescence.

Electrodes↗