Search PubMed⌕ Search

Biomedical subjects

Joon Koo Han

Publications and source records attributed to Joon Koo Han.

At least 37 records · Page 2Linked to original sources

Gadobenate dimeglumine-enhanced liver MRI as the sole preoperative imaging technique: a prospective study of living liver donors.

OBJECTIVE: The objective of our study was to determine whether gadobenate dimeglumine-enhanced MRI is practical as the sole preoperative imaging technique for the examination of living liver donors. SUBJECTS AND METHODS: Forty-four consecutive living donor candidates underwent liver MRI on a 1.5-T MR unit. The MR examination included in- and opposed-phase T1-weighted gradient-echo imaging, T2-weighted MR cholangiography, MR angiography (MRA) and parenchymal phase imaging after the administration of gadobenate dimeglumine, and 60-minute delayed T1-weighted MR cholangiography. Two abdominal radiologists analyzed the images regarding the depiction of the biliary duct anatomy and the hepatic vascular anatomy and for the presence of focal or diffuse liver disease. The findings were compared with intraoperative cholangiographic and surgical findings in 24 patients who underwent partial hepatectomy. RESULTS: In the 24 patients who underwent liver harvesting, 10 had biliary anatomic variants confirmed by intraoperative cholangiography. T2-weighted MR cholangiography allowed a correct diagnosis in 75% (n = 18/24) and T1-weighted MR cholangiography in 79% (n = 19/24) of these patients. When we evaluated the bile duct anatomy using the combined findings of T2- and T1-weighted MR cholangiographic images, the diagnostic accuracy increased to 92% (n = 22/24), but the difference was not statistically significant (p > 0.05). MRA showed a diagnostic accuracy of 79% (n = 19/24) for the hepatic arterial anatomy, 100% (n = 24/24) for the portal venous anatomy, and 96% (n = 23/24) for the hepatic venous anatomy. CONCLUSION: Gadobenate dimeglumine-enhanced MRI allows comprehensive assessment of the biliary and hepatic vascular systems and the hepatic parenchyma and can serve as the sole preoperative imaging test for living liver donor candidates.

Adolescent↗

Clinical significance of CT-defined minimal ascites in patients with gastric cancer.

AIM: To study the clinical significance of minimal ascites, which was only defined by the CT and whose nature was not determined preoperatively, in the relationship with the peritoneal carcinomatosis. METHODS: The medical records and the dynamic CT films of 118 patients with gastric cancer were reviewed. Factors associated with peritoneal carcinomatosis were analyzed in 40 patients who had CT-defined ascites of which the nature was surgically confirmed. RESULTS: Only 12.5-25% of the CT-defined minimal ascites, whose volume was estimated to be less than 50 mL, were associated with peritoneal carcinomatosis. When the estimated CT-defined ascitic volume was 50 mL or more, peritoneal carcinomatosis was identified in 75-100%. When CT-defined lymph node enlargements were not found beyond the regional gastric area, perigastric invasions were not suspected, and the size of tumor was less than 3 cm, peritoneal carcinomatosis seemed significantly less accompanied at the univariate analysis. However, except for the minimal volume of CT-defined ascites in comparison with the mild or more, other factors were not confirmed multivariately. CONCLUSION: In the patients with gastric cancer, CT-defined minimal ascites alone is rarely associated with peritoneal carcinomatosis, if it does not accompany other signs suggestive of malignant seeding. Therefore, consideration of active curative resection should not be hesitated, if CT-defined minimal ascites is the only delusive sign.

Ascites↗

Small-bowel obstruction in a phantom model of ex vivo porcine intestine: comparison of PACS stack and tile modes for CT interpretation.

PURPOSE: To compare computed tomographic (CT) image interpretation with picture archiving and communication systems (PACS) stack and tile modes for speed and accuracy of transition zone localization in small-bowel obstruction by using ex vivo porcine specimens. MATERIALS AND METHODS: Twenty-five small-bowel obstruction phantom models made of ex vivo porcine intestines from a slaughterhouse were imaged at CT. One was used for observer training, and 24 were used for experimentation. At 20-cm intervals throughout the intestines, metallic markers were placed in the mesenteries immediately adjacent to bowel. One obstruction was made in each intestine, midway between markers, by ligating intestine with a 3-0 silk suture to simulate mechanical small-bowel obstruction. The lumen proximal to the ligation site was distended with air and a soybean oil-iodized oil mixture until at least two-thirds of the proximal intestine exceeded 2.0 cm in transverse diameter. Dilated segments were 310-550 cm in length. Soybean oil and a mixture of soybean and iodized oil were used to simulate differences in attenuation among bowel wall, intraluminal fluid, and extraluminal abdominal fat. Four experienced abdominal radiologists independently determined the transition zone by using stack mode (cine viewing of stacked images) and, at least 2 weeks later, tile mode (side-by-side image display). Accuracy and degree of error in counting markers were evaluated, and speed of interpretation was recorded. Statistical analysis was performed with the McNemar and Wilcoxon signed rank tests. RESULTS: For all observers, accuracy of transition zone localization tended to be better with stack mode (63%-83% [15-20 phantoms]) than with tile mode (50%-63% [12-15 phantoms]), but the differences were not significant. For each observer, mean counting error was lower in stack mode (range, 0.96-2.48) than in tile mode (range, 1.74-3.22), with significance for three observers (P < .01, P < .01, and P = .04). Interpretation was significantly faster with stack mode by a factor of two to three for all observers (P < .01). CONCLUSION: Stack mode evaluation for identification of the transition zone in obstructed small bowel is faster than evaluation with tile mode. Accuracy is not significantly different between modes, although there is a tendency toward better results with stack mode.

Animals↗

Differentiating malignant from benign common bile duct stricture with multiphasic helical CT.

PURPOSE: To evaluate retrospectively the use of multiphasic helical computed tomography (CT) to differentiate malignant and benign common bile duct (CBD) strictures in patients with only a focal CBD stricture and to determine predictors for this differentiation. MATERIALS AND METHODS: Institutional review board approval and informed patient consent were not required. Fifty patients (35 men, 15 women; age range, 35-87 years; mean age, 61.6 years) with only a focal CBD stricture comprised the sample for this study (32 malignant and 18 benign strictures). The diagnosis of all malignant and five benign CBD strictures was confirmed by reviewing patients' surgical and pathology records; in 13 benign CBD strictures, the diagnosis was confirmed by means of clinical features. Multiphasic CT findings were analyzed with regard to the wall thickness, location, length, and enhancement pattern of the involved CBD, the upstream CBD diameter, and other findings. CT features to identify benign and malignant CBD strictures were compared by means of univariate analysis and multivariable stepwise logistic regression analysis. RESULTS: Malignant strictures were longer (17.9 mm +/- 6.6 [+/- standard deviation]) than benign strictures (8.9 mm +/- 6.8) (P < .0001), and upstream CBD diameters were larger in malignant cases (22.0 mm +/- 5.4) than in benign cases (17.8 mm +/- 4.6) (P = .033). The involved wall thickness was more than 1.5 mm in 26 malignant cases and three benign cases (P < .0001). During both hepatic arterial and portal venous phases, greater enhancement than that in the normal CBD were more frequently observed in malignant cases (in 27 and 30 patients for hepatic arterial and portal venous phase scans, respectively) than in benign cases (in two and three patients, respectively) (P < .0001). Results of multivariable stepwise logistic regression analysis showed that hyperenhancement of the involved CBD during the portal venous phase was the only variable that could be used to independently differentiate malignant from benign strictures. CONCLUSION: Hyperenhancement of the involved CBD during the portal venous phase is the main factor distinguishing malignant from benign CBD strictures.

Adult↗

Radiofrequency ablation in the liver using two cooled-wet electrodes in the bipolar mode.

The purpose of this study was to demonstrate the efficacy of bipolar radiofrequency ablation (RFA) using cooled-wet electrodes inducing coagulation in ex vivo bovine livers and in in vivo canine livers. In ex vivo experiments, 20 coagulations were created by monopolar (group A), and bipolar RFA (group B) using a 200 W generator (Valleylab) and one or two cooled-wet electrodes. In in vivo experiments, one coagulation was created by bipolar RFA in each of eight dogs via laparotomy. In ex vivo and in vivo experiments, RF was applied to one or two electrodes at 100 W for 10 min. The dimensions of the coagulations were compared in the two groups. In ex vivo experiments, the mean volumes of the coagulations produced in group B (54.0+/-16.5 cm3) were greater than those produced in group A (33.9+/-12.7 cm3) (P=0.007). In in vivo experiments, bipolar RFA produced a coagulation of 39.4+/-15.6 cm3 without a major complication. The present study showed that a RF electrode system using two cooled-wet electrodes in the bipolar mode created larger coagulation volumes than the monopolar mode, and this system can be used to create large coagulation without major complications.

Animals↗

Multicenter analysis of clinicopathologic features of intraductal papillary mucinous tumor of the pancreas: is it possible to predict the malignancy before surgery?

BACKGROUND: Despite recently increasing numbers of reports on intraductal papillary mucinous tumors (IPMTs), difficulties still remain in terms of diagnosis, treatment, and prognosis. The purpose of this multicenter study was to evaluate the clinicopathologic features of IPMT in Korea and to suggest predictive criteria for malignancy in IPMT. METHODS: We retrospectively reviewed the clinicopathologic data of 208 patients who underwent operations for IPMT between 1993 and 2002 at 28 institutes in Korea. RESULTS: Of the 208 patients (mean age, 61 years), 147 were men and 61 were women. A total of 124 patients underwent pancreatoduodenectomy, 42 underwent distal pancreatectomy, 17 underwent total pancreatectomy, and 25 underwent limited pancreatic resection. There were 128 benign cases (adenoma, n = 62; borderline, n = 66) and 80 malignant cases (noninvasive, n = 29; invasive, n = 51). A significant difference in 5-year survival was observed between the benign and malignant groups (92.6% vs. 65.3%; P = .006). Of the six factors (age, location, duct dilatation, mural nodule, main duct type, and tumor size) that showed statistical differences by univariate analysis between the benign and malignant groups, three were significant by multivariate analysis--namely, mural nodule (P = .009), tumor size (P = .023), and a dilated duct size (P = .010). CONCLUSIONS: A significant proportion of IPMTs are malignant, although the overall prognosis of IPMT is superior to that of ordinary pancreatic cancer. Radical surgery is recommended for IPMT with the predictors of malignancy: mural nodule, tumor size (> or =30 mm), and dilated duct size (> or =12 mm).

Adenocarcinoma, Mucinous↗

Appropriateness of a donor liver with respect to macrosteatosis: application of artificial neural networks to US images--initial experience.

PURPOSE: To retrospectively compare performance of artificial neural networks (ANNs) applied to ultrasonographic (US) images with that of radiologists for prediction of appropriateness of a donor liver with respect to macrosteatosis before liver transplantation. MATERIALS AND METHODS: Institutional ethics committee approved study; written informed consent was obtained. ANNs, constructed with three-layered 15-neuron back-propagation algorithm, were trained to predict appropriateness of a donor liver with respect to macrosteatosis by using statistically significant laboratory and US parameters derived from univariate analyses, together with correct diagnosis. Input variables for ANNs were alkaline phosphatase, glutamic oxaloacetic transaminase, glutamic pyruvate transaminase, gamma-glutamyltransferase, hepatorenal ratio of echogenicity, and tail area ratio and tail length of portal vein wall echogenicity. Three radiologists graded US images in 94 potential donors (71 men and 23 women) on the basis of four degrees of hepatic steatosis. After training and testing of ANNs, performance of ANNs and radiologists in predicting appropriateness of potential donors was evaluated with receiver operating characteristic (ROC) analysis and compared by means of univariate z score test. RESULTS: Among 94 potential donor livers, 76 were normal or had mild steatosis, and 18 had moderate or severe macrosteatosis at histopathologic examination. Area under ROC curve (Az) of ANNs (Az=0.9673) was significantly greater than that of radiologists (faculty, Az=0.9106, P=.048; fellow, Az= 0.9038, P=.044; resident, Az=0.8931, P=.038). No statistically significant difference in sensitivity for predicting appropriateness as a liver donor with respect to macrosteatosis was found between ANNs (88.9%) and radiologists (P >.05). However, specificity of ANNs (96.1%) was significantly better than that of radiologists (P <.003). CONCLUSION: ANNs might be a useful tool to categorize whether a donor liver is appropriate for transplantation with respect to macrosteatosis on the basis of multiple variables related to laboratory and US features. Further study is needed.

Adolescent↗

In vitro CT evaluation of intrahepatic stones: correlation with chemical composition.

OBJECTIVE: To describe in vitro CT features of intrahepatic stones and to correlate CT attenuation with chemical composition. MATERIALS AND METHODS: Of the patients who underwent choledochoscopic intrahepatic stone removal between 1998 and 2001, 54 patients with stones larger than 3 mm were enrolled in this study. In each case, a chemical compositional analysis was performed to determine calcium, cholesterol, total bilirubin, and inorganic phosphorus compositions. The three largest stones obtained from each patient were imaged by CT. CT attenuation numbers were measured in the center images of each stone by drawing free-hand region of interest (ROI). The measured CT attenuation numbers were correlated with their chemical composition. Also, CT attenuation numbers of stones were compared with that of the liver on non-contrast CT (50-70 HU). RESULTS: Stone size ranged from 3.1 to 10.5 mm (mean +/- S.D.: 6.0 +/- 1.4). The CT attenuation numbers (HU) of stones ranged from 36.4 to 410.19 (mean +/- S.D.: 94.6 +/- 49.9). CT numbers of stones were below 70 HU in 11 patients (20.4%), and below 90 HU in 33 patients (59.3%). The chemical analysis data of the stones were as follows: calcium (0.5-6.5 wt.%; mean +/- S.D., 2.6 +/- 1.4), total bilirubin (0.45-24.4 wt.%; 13.1 +/- 6.2), cholesterol (5.4-73.9 wt.%; 29.3 +/- 17.4), phosphorus (0.1-1.2 wt.%; 0.6 +/- 0.3), and non-soluble residue (17.6-85.4 wt.%; 57.0 +/- 22.6). There was a weak but significant correlation between calcium composition and CT attenuation (r = 0.38, P < 0.01) and no significant correlation between other chemical compositions and the CT attenuation (cholesterol, r = 0.01, P > 0.01; total bilirubin, r = 0.05, P > 0.01; phosphorus, r = 0.01, P > 0.01). CONCLUSION: On non-contrast CT, intrahepatic stones would not be hyperattenuating with respect to liver parenchyma in about one fifth of patients. The CT attenuation of stones correlates with calcium and does not correlate with any other chemical composition.

Adult↗

Wet radio-frequency ablation using multiple electrodes: comparative study of bipolar versus monopolar modes in the bovine liver.

OBJECTIVE: To determine whether hypertonic saline (HS)-mediated bipolar radio-frequency (rf) application as advantages over monopolar simultaneous and alternating rf applications for creating larger areas of coagulation necrosis. MATERIALS AND METHODS: A total of 60 rf ablations using double perfused-cooled electrodes and a 200 W generator (CC-3 model, Radionics) were performed in three different modes in explanted bovine livers: simultaneous monopolar mode (groups A and A'); alternating monopolar mode (groups B and B'); or bipolar mode (groups C and C'). Electrodes were placed at inter-electrode distances of 3 and 5 cm, and HS (6% NaCl solution) was instilled into tissue at a rate of 1 mL/min through the electrodes. rf was applied for 10 (3 cm distance) or 15 min (5 cm distance). During rf application, we measured the tissue temperature at the mid-point between the two electrodes. Dimensions of the thermal ablation zones, and temperatures were compared between the 3 groups using analysis of variance or the Kruskal-Wallis test. To compare configurations of the ablation zones in each group, the ratio of longitudinal diameter (Dl) to vertical diameter (D(v)) was calculated. RESULTS: With a 3-cm inter-electrode spacing, the D(v) between the electrodes of ablated lesions was 2.4 +/- 1.2 cm in group A, 4.5 +/- 1.0 cm in group B, and 6.1 +/- 0.9 cm in group C (P < 0.05), and at a 5-cm spacing, groups B' and C' produced a single ablation area, but group A' produced two separated ablation spheres: the D(v)s were 1.4 +/- 0.2 in group A, 2.9 +/- 1.0 mm in group B, and 6.6 +/- 0.4 cm in group C (P < 0.05). For both 5- and 3-cm spacings, the temperatures at the mid-point were higher in bipolar mode than in either monopolar simultaneous or alternating modes. The ratios of Dl/D(v) of groups A, B, and C were 2.5 +/- 0.2, 1.4 +/- 0.1, and 1.1 +/- 0.1, respectively, and the corresponding figures of groups A', B' and C' were 4.5 +/- 0.2, 2.7 +/- 0.1, and 1.1 +/- 0.1, respectively (P < 0.05). CONCLUSION: HS-enhanced bipolar rf ablation creates larger, more regular coagulation necrosis than either monopolar simultaneous or alternating rf ablation.

Analysis of Variance↗

Hepatic attenuation differences associated with obstruction of the portal or hepatic veins in patients with hepatic abscess.

OBJECTIVE: The purpose of our study was to determine the nature of the association between the attenuation difference of the hepatic parenchyma surrounding an abscess and obstruction of the regional portal vein or of the hepatic vein. MATERIALS AND METHODS: Helical CT scans of 60 patients with hepatic abscess were analyzed for the presence of complete or partial obstruction of the portal or hepatic veins and for attenuation differences in the surrounding parenchyma. Clinical (age, sex, underlying disease, and microorganism) and CT (obstruction of the portal or hepatic vein and number, location, and size of abscesses) findings were analyzed statistically for possible associations with each of regional parenchymal hyper- and hypoattenuation by using the chi-square test and multivariate logistic regression analysis. RESULTS: Regional parenchymal hyperattenuation was identified in 40 patients (67%). More patients with portal vein obstruction showed regional parenchymal hyperattenuation than patients without portal vein obstruction (22/27 patients vs 18/33, p = 0.028), and more patients with hepatic vein obstruction showed regional parenchymal hypoattenuation than those without hepatic vein obstruction (11/21 vs 3/39, p = 0.0003). Multivariate logistic regression analysis showed that portal venous obstruction was the only statistically significant predictor of regional parenchymal hyperattenuation (p = 0.032; odds ratio, 3.7) and that parenchymal hypoattenuation was associated with hepatic venous obstruction (p = 0.001; odds ratio, 44.9). CONCLUSION: Parenchymal hypo- and hyperattenuation are frequently observed in the hepatic region surrounding an abscess on dynamic CT. Moreover, these parenchymal attenuation differences are associated with regional portal or hepatic vein obstruction.

Adult↗

Postbiopsy splenic bleeding in a dog model: comparison of cauterization, embolization, and plugging of the needle tract.

OBJECTIVE: The purpose of our study was to compare radiofrequency cauterization, embolization using an absorbable gelatin sponge, and a Histoacryl-Lipiodol mixture plugging as postbiopsy bleeding reduction methods after splenic core needle biopsy in a dog model. MATERIALS AND METHODS: Eleven mongrel dogs were randomly separated into nonheparinized (n = 5) and heparinized (n = 6) groups. Eight splenic biopsies per animal were performed using an 18-gauge automated core biopsy needle: two as controls, two ablated by radiofrequency, two embolized using an absorbable gelatin sponge, and two plugged using a Histoacryl-Lipiodol mixture. Procedure times and postbiopsy bleeding amounts were assessed. Statistically significant differences were determined by repeated measures analysis of variance; the Tukey-Kramer test for multiple comparisons was used for post hoc comparisons. Three-day follow-up CT scans were obtained to check for procedure-related complications or delayed bleeding. RESULTS: The postbiopsy bleeding reduction groups showed significantly less blood loss than the control group for both the nonheparinized (p < 0.0001) and heparinized groups (p < 0.0001). In the heparinized group, both radiofrequency cauterization (p < 0.01) and gelatin sponge embolization (p < 0.05) significantly reduced bleeding compared with Histoacryl-Lipiodol mixture plugging. Gelatin sponge embolization was the longest procedure (p < 0.001). On follow-up CT, no delayed bleeding was observed. However, multiple Histoacryl-Lipiodol emboli were observed in the splenic and portal veins in all the dogs we treated. CONCLUSION: Radiofrequency cauterization was found to be the most useful postbiopsy bleeding reduction method in terms of the amount of bleeding and the procedure time.

Analysis of Variance↗

Effect of adjusted positioning on gastric distention and fluid distribution during CT gastrography.

OBJECTIVE: We hypothesized that performing CT gastrography with the patient in the left posterior oblique (LPO) position would provide better distention and less residual fluid for the lower part of the stomach than CT gastrography with the patient in the standard supine position. CONCLUSION: The LPO position for CT guaranteed the distensibility of and minimal residual fluid in the lower part of the stomach, thus resulting in excellent 3D CT gastrographic images.

Adult↗

Bipolar radiofrequency ablation using wet-cooled electrodes: an in vitro experimental study in bovine liver.

OBJECTIVE: Our aim was to evaluate the performance of hypertonic saline (HS)-enhanced bipolar radiofrequency ablation using wet-cooled electrodes versus monopolar radiofrequency ablation to create coagulation necrosis in explanted bovine liver. CONCLUSION: HS-enhanced bipolar radiofrequency ablation using the wet-cooled electrodes shows better performance in creating coagulation necrosis than the monopolar mode.

Animals↗

Comparison of renal ablation with monopolar radiofrequency and hypertonic-saline-augmented bipolar radiofrequency: in vitro and in vivo experimental studies.

OBJECTIVE: We sought to determine whether hypertonic-saline (HS)-augmented bipolar radiofrequency ablation has advantages over monopolar radiofrequency ablation for creating larger areas of coagulation necrosis in the kidney. MATERIALS AND METHODS: Using a 200-W generator and bipolar perfused-cooled electrodes or a monopolar cooled-tip electrode, we performed 14 radiofrequency ablations in explanted bovine kidneys. Radiofrequency was applied in standard monopolar (n = 7) or bipolar (n = 7) modes at 100 W for 10 min. In the bipolar mode, the perfused-cooled electrodes were placed at interelectrode distances of 3 cm, and a 6% sodium chloride solution was instilled into tissue at a rate of 2 mL/min through the electrodes. For in vivo experiments, either monopolar (n = 7) or HS-augmented bipolar (n = 7) radiofrequency ablation was performed in the lower pole of canine kidneys. Three days after the procedure, contrast-enhanced CT scans were obtained to evaluate the volumes of the ablation regions, and the kidneys were harvested for gross measurements. Technical parameters such as changes in impedance and current during radiofrequency ablation and dimensions of the thermal ablation zones were compared between the two groups. RESULTS: In ex vivo and in vivo experiments, the frequency of the pulsed radiofrequency application caused by rises in impedance was higher in the monopolar mode than in the bipolar mode during the application of radiofrequency energy. The in vivo study showed that the bipolar radiofrequency ablation allowed larger mean current flows than the monopolar radiofrequency ablation (i.e., mean +/- SD, 1,654 +/- 144 mA vs 967 +/- 597 mA) (p < 0.05). Ex vivo studies revealed that the volumes of bipolar radiofrequency-induced ablation regions were substantially larger than those of monopolar radiofrequency-induced ablation regions (26.1 +/- 10.5 cm(3) vs 10.2 +/- 4.2 cm(3)). In vivo studies showed bipolar radiofrequency ablation achieved larger coagulation necrosis than monopolar radiofrequency (3.2 +/- 0.3 cm vs 2.4 +/-0.4 cm) (p < 0.05). This was confirmed by the measured volume of nonenhancing area on contrast-enhanced CT (20.4 +/- 6.4 cm(3) vs 13.5 +/- 6.0 cm(3)). CONCLUSION: HS-augmented bipolar radiofrequency ablation using perfused-cooled electrodes shows better performance in creating coagulation necrosis than monopolar radiofrequency ablation in the kidney of an animal model.

Animals↗

Value of contrast-enhanced sonography for the characterization of focal hepatic lesions in patients with diffuse liver disease: receiver operating characteristic analysis.

OBJECTIVE: Our aim was to assess the diagnostic performance of contrast-enhanced agent detection sonographic imaging to characterize focal hepatic lesions in patients with diffuse liver disease in comparison with baseline sonographic images and to determine whether agent detection imaging can reduce the necessity of further diagnostic workup for lesion characterization. MATERIALS AND METHODS: Contrast-enhanced sonography using 4 g of Levovist at a concentration of 300 mg/mL was performed on 75 focal hepatic lesions in 75 patients with diffuse liver disease. Interval reviews for both baseline without and with contrast-enhanced sonography were performed independently by two radiologists. They were requested to determine the malignity of focal hepatic lesions using a 5-point confidence level and to record the specific diagnoses and the necessity for further imaging for lesion characterization. Radiologists' performances for lesion differentiation using baseline and contrast-enhanced sonography were evaluated using receiver operating characteristic (ROC) analysis. Interobserver agreement was also analyzed. RESULTS: When contrast-enhanced sonography was used, ROC analysis revealed a significant improvement for both reviewers (area under the receiver operating characteristic curve [A(z)] = 0.753 and 0.830 and 0.971 and 0.974 at baseline sonography and contrast-enhanced sonography, respectively; p < 0.002) for differentiating malignant and benign focal liver lesions. Contrast-enhanced sonography also improved specificity from 12% to 91% for reviewer 1 and from 26% to 85% for reviewer 2 compared with baseline sonography. Furthermore, excellent interobserver agreement was achieved for contrast-enhanced sonography (weighted kappa = 0.919), whereas only good agreement was achieved for baseline sonography (weighted kappa = 0.656). A better result for specific diagnosis was obtained by contrast-enhanced sonography (79% and 75%) than by baseline sonography (37% and 48%, p < 0.05). Contrast-enhanced sonography (72% and 63%) outperformed baseline sonography (35% and 28%, p < 0.05) as a confirmatory imaging technique. CONCLUSION: Contrast-enhanced agent detection sonography can be used to characterize focal hepatic lesions in patients with diffuse liver disease reliably and with a higher diagnostic confidence than baseline sonography. Furthermore, contrast-enhanced sonography reduced the need for further diagnostic workups for focal hepatic lesion characterization.

Adult↗