Search PubMed⌕ Search

Biomedical subjects

Jonathan S Lewin

Publications and source records attributed to Jonathan S Lewin.

67 records · Page 4Linked to original sources

Do surgical clips interfere with radiofrequency thermal ablation?

OBJECTIVE: This study sought to evaluate whether surgical clips affect tissue conductivity and thereby alter the induction of radiofrequency ablation lesions and to determine whether therapy is safe after previous placement of clips in the liver. MATERIALS AND METHODS: An ex vivo porcine hepatic model was used. Three clips were placed around a radiofrequency electrode at 10, 20, and 30 mm from the point of insertion. Clips were arranged in a plane either perpendicular or parallel to the electrode track. After placement of the liver specimen on a grounding pad, radiofrequency energy was applied in a standardized manner for 5 min. Lesion growth and morphology were documented for each minute. RESULTS: Radiofrequency lesions appeared circular and homogeneous after 5 min. Lesion diameter perpendicular to the radiofrequency electrode averaged 30 mm. However, lesion formation was irregular during the early phase of the radiofrequency ablation. The lesion extended irregularly toward the 1-cm clip after 60 sec of ablation. During the second minute, a distinct lesion was observed around the clip 1 cm from the electrode; the primary lesion had not yet reached the clip. During the final 3 min, the primary lesion reached the 1-cm clip and ultimately incorporated the satellite lesion. No lesions were detected surrounding the more distant clips. CONCLUSION: Our data suggest that with the parameters applied in our study, radiofrequency ablation can be safely performed in patients with implanted clips. No aberrant conduction is observed around surgical clips that are located 20 mm and further from the radiofrequency electrode.

Animals↗

MR imaging-guided vascular procedures using CO2 as a contrast agent.

OBJECTIVE: The purpose of this study was to test the use of CO(2) as a black blood contrast agent for MR imaging-guided vascular procedures in an animal model. MATERIALS AND METHODS: Repeated intraarterial CO(2) injections were performed through a catheter located in the aorta and the renal arteries of three fully anesthetized pigs. Real-time images were acquired using a steady-state free precession sequence. RESULTS: During the CO(2) injections, the bright blood in the aorta and the main renal artery was totally replaced, and this procedure resulted in an immediate, statistically significant signal loss in the vessel lumen. In more peripheral vessels, CO(2) improved the vessel conspicuity substantially. Confirmation of vessel patency distal to the catheter tip position was possible. CONCLUSION: The use of carbon dioxide in combination with a bright blood MR imaging sequence improves vessel conspicuity and provides immediate information about blood flow distal to the catheter. This technique may be used to facilitate MR imaging-guided intravascular procedures.

Animals↗

A phase I pharmacokinetic and translational study of the novel vascular targeting agent combretastatin a-4 phosphate on a single-dose intravenous schedule in patients with advanced cancer.

Combretastatin A-4 phosphate (CA4P) is a novel antitumor vascular targeting agent, the first agent of this class of compounds to enter the clinic. We performed a Phase I trial to determine the maximum-tolerated dose, safety, and pharmacokinetic profile of CA4P on a single-dose i.v. schedule. We also obtained preliminary data on its effect on tumor blood flow using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) techniques and cell adhesion molecules at the higher-dose levels. Twenty-five assessable patients with advanced cancer received a total of 107 cycles over the following dose escalation schema: 18, 36, 60, 90 mg/m(2) as a 10-min infusion and 60 mg/m(2) as a 60-min infusion at 3-week intervals. There was no significant myelotoxicity, stomatitis, or alopecia. Tumor pain was a unique side effect, which occurred in 10% of cycles, and there were four episodes of dose-limiting toxicity at dosages > or =60 mg/m(2), including two episodes of acute coronary syndrome. Pharmacokinetics revealed rapid dephosphorylation of the parent compound (CA4P) to combretastatin A4 (CA4), with a short plasma half-life (approximately 30 min). A significant (P < 0.03) decline in gradient peak tumor blood flow by DCE-MRI in six of seven patients treated at 60 mg/m(2) was observed. A patient with anaplastic thyroid cancer had a complete response and is alive 30 months after treatment. The toxicity profile is consistent with a drug that is "vascularly active" and devoid of traditional "cytotoxic" side effects. Dosages < or =60 mg/m(2) as a 10-min infusion define the upper boundary of the maximum-tolerated dose.

Adult↗

Increased presence of white matter hyperintensities in adolescent patients with bipolar disorder.

Several reports have noted an increase in white matter hyperintensities (WMH) on MRI scans of adult patients with bipolar disorder. We investigated whether this increase was also evident in a group of adolescent patients with bipolar disorder. The sample consisted of 15 bipolar patients, 19 patients with schizophrenia and 16 healthy comparison subjects. All subjects were adolescents. WMH were blindly rated on T2-weighted and PD-weighted MRI scans using our own scale with documented inter-rater reliability. WMH were present in 10 of 15 bipolar patients (67%), seven of 19 patients with schizophrenia (37%) and five of 16 comparison subjects (31%). The bipolar adolescent group had a statistically significant increased presence of WMH compared both with healthy comparison subjects and the schizophrenic group. The association between WMH and bipolar disorder appears to extend to the adolescent years.

Adolescent↗

A brief review of hardware for catheter tracking in magnetic resonance imaging.

Magnetic resonance imaging (MRI) has traditionally been used exclusively in a role for patient diagnosis. However, it is unlikely that this role is sufficient for its continued prominence in medical imaging. Instead, the more ambitious role in diagnosis and also therapy/intervention will occur as demand for minimally invasive procedures increases. Fortunately, with recent improvement in technical specifications and creative pulse sequence design, MRI systems can now provide high quality near-real-time images that facilitate a variety of image-guided procedures, many based around delivery via catheters. While X-ray opacity is not available as a means for detecting the progression of the catheter in MRI systems today, a variety of novel hardware devices have been designed and used for MRI catheter tracking. This report provides a brief review of some fundamental methods for catheter tracking in MRI.

Catheterization↗

Three-dimensional model of lesion geometry for evaluation of MR-guided thermal ablation therapy.

RATIONALE AND OBJECTIVES: High-radiofrequency energy is used clinically to ablate pathologic tissue with interventional magnetic resonance (MR) imaging. For many tissues, resulting lesions have a characteristic appearance on contrast-enhanced T1- and T2-weighted MR images, with two boundaries enclosing an inner hypointense region and an outer hyperintense margin. Geometric modeling of three-dimensional thermal lesions in animal experiments and patient treatments would improve analyses and visualization. MATERIALS AND METHODS: The authors created a model with two quadric surfaces and 12 parameters to describe both lesion surfaces. Parameters were estimated with iterative optimization to minimize the sum of the squared shortest distances from segmented points to the model surface. The authors validated the estimation process with digital lesion phantoms that simulated varying levels of segmentation error and missing surface information. They also applied their method to in vivo images of lesions in a rabbit model. RESULTS: For simulated phantom lesions, the lesion geometry was accurate despite manual segmentation error and incomplete surface data. Even when 50% of the surface was missing, the median error was less than 0.5 mm. For all in vivo lesions, the median distance from the model surface to data was no more than 0.58 mm for both inner and outer surfaces, less than a voxel width (0.7 mm). The interquartile range was 0.89 mm or less for all data. CONCLUSION: The authors' model provides a good approximation of actual lesion geometry and is highly resistant to missing segmentation information. It should prove useful for three-dimensional lesion visualization, volume estimation, automated segmentation, and volume registration.

Abdominal Muscles↗

Use of a blood-pool contrast agent for MR-guided vascular procedures: feasibility of ultrasmall superparamagnetic iron oxide particles.

RATIONALE AND OBJECTIVES: The purpose of this study was to examine the dose dependency of the intravascular signal intensity after injection of ultrasmall superparamagnetic iron oxide (USPIO) particles (SH U 555 C) in a rabbit model studied with a low-field-strength magnetic resonance (MR) imaging system. The results were used to facilitate MR-guided vascular procedures in a pig. MATERIALS AND METHODS: All experiments were performed at 0.2 T. To determine the optimum USPIO (or SH U 555 C) dose for intravascular interventions, the authors acquired coronal three-dimensional MR angiographic images in 12 rabbits after injection of four dose levels (10, 20, 30, and 40 micromol of iron per kilogram body weight). The intraaortic signal intensities were measured in user-defined regions of interest. For numerical analysis, signal intensity enhancement was computed. Subsequently MR image-guided procedures were performed in USPIO-enhanced vessels in one pig. RESULTS: The signal intensity evaluation shows a clear-cut dose dependence in both early and late phases after administration of SH U 555 C. A high-spatial-resolution MR angiogram acquired 20 minutes after injection yielded the best results with the highest dose (40 micromol of iron per kilogram); at that dose, intravascular enhancement was sufficient for vascular procedures for 60 minutes after injection. CONCLUSION: SH U 555 C is a promising contrast agent for MR angiography and MR-guided vascular procedures in an open low-field-strength MR imager.

Animals↗

MR imaging-guided radio-frequency thermal ablation of the lumbar vertebrae in porcine models.

PURPOSE: To test the hypotheses that (a) magnetic resonance (MR) imaging-guided radio-frequency (RF) thermal ablation of the vertebrae is feasible in porcine models, (b) procedure safety depends on the location of ablation within the vertebra, and (c) MR imaging allows accurate monitoring of induced thermal lesion size and shape. MATERIALS AND METHODS: Ten percutaneous MR imaging-guided RF thermal ablations were randomized over various lumbar vertebral levels and locations in seven pigs. Animals were followed up for 2, 7, or 14 days before sacrifice. Thermal lesion size and shape as measured on MR images obtained immediately after ablation and at follow-up were compared with gross pathologic findings. Mean absolute differences between lesion diameters at pathologic examination and MR imaging were evaluated by using a paired t test, as were differences between lesion-to-vertebra contrast-to-noise ratios obtained for each sequence. Clinical and imaging data were correlated with histologic findings. RESULTS: Successful RF electrode placement in the targeted part of the vertebra was achieved in all procedures. Ablations performed away from neural elements were safe to perform. Pedicular ablations resulted in radiculopathy, whereas ablations performed directly over the posterior cortex resulted in paraplegia. Lesion sizes measured on T2-weighted images were closest to those measured at gross pathologic examination (mean absolute difference, 0.72 mm +/- 0.83 [SD]), followed by those measured on contrast material-enhanced T1-weighted (1.27 mm +/- 0.83) and short inversion time inversion-recovery (STIR) (1.5 mm +/- 1.84) images. Size measurements obtained on T2-weighted images were significantly closer to gross pathologic measurements than were those obtained on contrast-enhanced T1-weighted images (P =.013) but were not different from those obtained on STIR (P =.27) images. The contrast-to-noise ratio was significantly higher for contrast-enhanced T1-weighted images than for T2-weighted (P <.001) or STIR (P <.001) images. CONCLUSION: MR imaging-guided RF thermal ablation of the vertebrae is feasible in porcine models, but the safety of the procedure depends on the location of ablation within the vertebra. MR imaging allows accurate monitoring of thermal lesion size and shape.

Animals↗

Femur: MR imaging-guided radio-frequency ablation in a porcine model-feasibility study.

PURPOSE: To determine the feasibility of magnetic resonance (MR) imaging-guided and -monitored radio-frequency (RF) ablation of bone. MATERIALS AND METHODS: Seven femurs were treated in five pigs with use of a 0.2-T open MR imager. An 11-gauge bone marrow needle was percutaneously inserted into the distal femur metaphysis with MR fluoroscopy (fast imaging with steady-state precession, or FISP, sequences) to introduce an RF electrode into the bone with further image guidance. Thermal ablation was performed for 10 minutes (90 degrees C +/- 2 [mean +/- SD]). MR follow-up was performed immediately after ablation and again at 7 and 14 days after the procedure (with contrast material-enhanced T1-weighted, T2-weighted, and fast short inversion time inversion-recovery, or STIR, sequences). The animals were sacrificed at day 14. The femurs were sliced, decalcified, and stained. Image analysis was performed to measure lesion diameter and contrast-to-noise ratio (CNR) and to evaluate complications. RESULTS: Technical success was obtained in all animals. The lesion diameter perpendicular to the electrode was 15.4 mm +/- 2.7. No significant complications were noted. The thermal lesions displayed low signal intensity with a sharp rim of high signal intensity. T2-weighted images demonstrated the highest CNR and the lowest error in predicting the lesion size immediately after ablation (2.7 mm +/- 1.3). Contrast-enhanced T1-weighted images demonstrated the highest accuracy at day 14 (1.0 mm +/- 1.0). CONCLUSION: RF ablation of bone with MR imaging as the sole imaging modality is feasible and allows monitoring of the ablation.

Animals↗

Use of intra-articular carbon dioxide and air for MR arthrography: a feasibility study.

During animal experiments, carbon dioxide (CO(2)) and air were used as a novel contrast agent for direct magnetic resonance arthrography (MRAr). MRAr was performed after injection of CO(2) and air in the knee joints of two pigs. MR images of phantoms containing air, CO(2) and nitrogen were compared. After intra-articular injection, both present as a signal void on various sequences and permit sharp delineation of cartilage and other adjacent structures. Despite the potential for artefact generation, only a slight susceptibility artefact was seen after injection of CO(2) and air. In phantom experiments, air, CO(2) and nitrogen demonstrated identical slight regular susceptibility artefacts at the phantom margins. CO(2) MRAr can yield high contrast between cartilage, ligaments and synovium relative to the joint compartment. Therefore, this technique might be useful as an investigational method for the evaluation of cartilage surface lesions and possibly as an alternative contrast agent for clinical use.

Air↗

A new type of susceptibility-artefact-based magnetic resonance angiography: intra-arterial injection of superparamagnetic iron oxide particles (SPIO) A Resovist in combination with TrueFisp imaging: a feasibility study.

The goal of this study was to evaluate the use of super paramagnetic particles of iron oxide (SPIO) as a dark blood contrast agent, in combination with a bright blood steady-state free precession sequence for magnetic resonance angiography (MRA), in an animal model. The original concentration of the SPIO of 500 mmol Fe/l and dilutions to 250, 125, 60, 30, 10 and 5 mmol Fe/l were intra-arterially injected into the aorta of a pig. Then the dilution of 10 mmol Fe/l was chosen for repeated intra-arterial injections into two pigs. During these intra-arterial SPIO injections MR images were acquired with a 1.5 T scanner. Signal intensity measurements were performed in the aorta. The signal-to-noise ratio during SPIO bolus passage was significantly less than during baseline conditions (Fisher's F-ratio 159.8, p < 0.005) or the recovery signal-to-noise ratio (Fisher's F-ratio 144.6, p < 0.005). Also, confirmation of flow distal to the catheter-tip position was possible. The use of SPIO as a dark blood agent in combination with a bright blood MR imaging sequence is feasible. Temporary loss of intraluminal signal occurs due to local decrease of the signal because of induction of local inhomogeneities after mixture the present blood and SPIO solution. It provides immediate information about blood flow distal to the catheter and is a potentially useful to guide intravascular MR-interventional procedures.

Animals↗

Assessment of automatic vessel tracking techniques in preoperative planning of transluminal aortic stent graft implantation.

OBJECTIVE: To evaluate automatic vessel tracking techniques in the course of preoperative planning prior to transluminal aortic endograft implantation by comparing accuracy, reproducibility, and postprocessing time with source image and volume-rendered analysis methods. METHODS: Multislice computed tomography datasets of 5 patients with abdominal aortic aneurysms were preoperatively examined, performing volumetric analysis of diameter and position of renal artery orifices, aneurysmal neck, maximal aneurysmal extension, aortic bifurcation, and iliac arteries and bifurcation. Analysis was realized by utilizing transverse datasets, volume rendering, and automated vessel tracking strategies (MxView, Philips, Best, The Netherlands). Measurement techniques were evaluated by 2 independent readers 3 times for each patient and measurement modality. Statistical analysis evaluated accuracy of the measurements and intra- and interobserver reliability. Postprocessing time was documented. RESULTS: Using transverse source datasets, intraobserver reliability ranged from 0.49 to 0.58. Intraobserver reliability improved to 0.7 to 0.98 when volume-rendered datasets were evaluated. Interobserver variability for transverse and volume-rendered datasets ranged from 0.49 to 0.76 and 0.70 to 0.96, respectively. Automated vessel tracking datasets did not demonstrate any intra- or interobserver variability. Based on transverse datasets, the length and diameter of iliac arteries and location and diameter of the aneurysmal neck were measured as statistically different in all cases in contrast to volume rendering and automated segmentation techniques. Postprocessing time consumption for measurements based on transverse, volume-rendered, and automated tracking segmentation datasets averaged 3.32 minutes, 25.43 minutes, and 2.24 minutes, respectively. CONCLUSIONS: Preoperative measurements improve significantly if datasets are evaluated based on volume-rendering techniques. This time-consuming procedure can be shortened, while further reducing observer variability, with automatic segmentation techniques.

Aged↗