Search PubMed⌕ Search

Biomedical subjects

Jonas Zmuidzinas

Publications and source records attributed to Jonas Zmuidzinas.

3 recordsLinked to original sources

A broadband superconducting detector suitable for use in large arrays.

Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths. Single-pixel X-ray detectors now have a resolving power of DeltaE < 5 eV for single 6-keV photons, and future X-ray astronomy missions anticipate the need for 1,000-pixel arrays. Here we report the demonstration of a superconducting detector that is easily fabricated and can readily be incorporated into such an array. Its sensitivity is already within an order of magnitude of that needed for CMB observations, and its energy resolution is similarly close to the targets required for future X-ray astronomy missions.

Journal Article↗

Thermal noise and correlations in photon detection.

The standard expressions for the noise that is due to photon fluctuations in thermal background radiation typically apply only for a single detector and are often strictly valid only for single-mode illumination. I describe a technique for rigorously calculating thermal photon noise, which allows for arbitrary numbers of optical inputs and detectors, multiple-mode illumination, and both internal and external noise sources. Several simple examples are given, and a general result is obtained for multimode detectors. The formalism uses scattering matrices, noise correlation matrices, and some fundamentals of quantum optics. The covariance matrix of the photon noise at the detector outputs is calculated and includes the Hanbury Brown and Twiss photon-bunching correlations. These correlations can be of crucial importance, and they explain why instruments such as autocorrelation spectrometers and pairwise-combined interferometers are competitive (and indeed common) at radio wavelengths but have a sensitivity disadvantage at optical wavelengths. The case of autocorrelation spectrometers is studied in detail.

Journal Article↗

Cramér-Rao sensitivity limits for astronomical instruments: implications for interferometer design.

Multiple-telescope interferometry for high-angular-resolution astronomical imaging in the optical-IR-far-IR bands is currently a topic of great scientific interest. The fundamentals that govern the sensitivity of direct-detection instruments and interferometers are reviewed, and the rigorous sensitivity limits imposed by the Cramér-Rao theorem are discussed. Numerical calculations of the Cramér-Rao limit are carried out for a simple example, and the results are used to support the argument that interferometers that have more compact instantaneous beam patterns are more sensitive, since they extract more spatial information from each detected photon. This argument favors arrays with a larger number of telescopes, and it favors all-on-one beam-combining methods as compared with pairwise combination.

Journal Article↗