Search PubMed⌕ Search

Biomedical subjects

Jon Karlsson

Publications and source records attributed to Jon Karlsson.

At least 19 recordsLinked to original sources

The value of ultrasonography in the preoperative diagnostic evaluation of patients with recurrent anterior shoulder dislocation: a prospective study of 44 patients.

The purpose of this study was to investigate the value of ultrasonography in the pre-operative assessment of patients with recurrent post-traumatic, anterior shoulder instability. Forty-four consecutive patients, 44 men and 12 women, with unilateral, post-traumatic, recurrent instability of the shoulder were included in the study. One experienced radiologist examined all patients, using a 5.0 or 7.5 MHz linear-array transducer, with the arm in different positions, one of which was used to provoke apprehension of the shoulder. Special attention was paid to the evaluation of the joint capsule, the anterior labrum, especially in terms of the presence of a Bankart lesion. All patients were subsequently treated surgically. After a diagnostic arthroscopy either an open or arthroscopic stabilisation of the shoulder was performed. Ultrasonography disclosed an unstable anterior labrum (equivalent to a Bankart lesion) in 36 shoulders; the lesion was verified in all 36 shoulders during arthroscopy. In three shoulders, arthroscopy disclosed an injured labrum, which had healed in an anterio-medial position on the scapular neck. In these three shoulders, ultrasonography failed to show any lesion. In five shoulders no Bankart lesion was found at arthroscopy. All these patients had increased shoulder laxity, and ultrasonography did not show any Bankart lesion. Furthermore a judgement of the joint capsule was not possible either. A bony Bankart lesion was found in four shoulders, using both arthroscopy and ultrasonography. The sensitivity of the ultrasonographic evaluation was 92%, and the specificity 100%. The positive predictive value was 100%, and the negative predictive value 63%. Ultrasonography showed a high correlation with the arthroscopic findings, with a high sensitivity and specificity. Therefore, we conclude that US can give important pre-operative information in patients with recurrent, unilateral, post-traumatic, anterior shoulder instability.

Adult↗

The Achilles tendon Total Rupture Score (ATRS): development and validation.

BACKGROUND: There is a need for a patient-relevant instrument to evaluate outcome after treatment in patients with a total Achilles tendon rupture. PURPOSE: To develop and validate a new patient-reported instrument for measuring outcome after treatment for total Achilles tendon rupture. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 1. METHODS: Development of this instrument consisted of item generation and test construction, item reduction, validation, evaluation of structure and internal consistency, test-retest, and test for responsiveness. The final version, the Achilles tendon Total Rupture Score (ATRS), was tested for validity, structure, and internal consistency (Cronbach's alpha) on 82 patients and 52 healthy persons. A correlation analysis was performed of the ATRS with the 2 validated foot/ankle/Achilles tendon scores, the Foot and Ankle Outcome Score (FAOS) and the Swedish version of the Victorian Institute of Sports Assessment-Achilles questionnaire (VISA-A-S). Structure was evaluated with factor analysis. Test-retest reliability was evaluated on 43 patients. The ATRS responsiveness was tested on 43 patients by calculating the effect size. RESULTS: The total score for the patients ranged from 17 to 100 with a mean (median) of 77 (85) and a standard deviation (interquartile range) of 21.4 (23). A significantly (P < .0001) higher total score was found for the healthy subjects, ranging from 94 to 100 with a mean (median) of 99.8 (100) and a standard deviation (interquartile range) of 1.1 (0). The ATRS correlated significantly (P < .01) with all subscales of the FAOS (r = 0.60-0.84) and the VISA-A-S (r = 0.78). The factor analysis gave 1 factor of importance. The internal consistency was 0.96 as measured with Cronbach's alpha. The test-retest produced an intraclass correlation coefficient of 0.98. The tests for responsiveness showed an effect size between 0.87 and 2.21. CONCLUSION: The ATRS is a patient-reported instrument with high reliability, validity, and sensitivity for measuring outcome after treatment in patients with a total Achilles tendon rupture. CLINICAL RELEVANCE: The ATRS is a self-administered instrument with high clinical utility, and we suggest the score for measuring the outcome, related to symptoms and physical activity, after treatment in patients with a total Achilles tendon rupture.

Achilles Tendon↗

A prospective comparison of bone-patellar tendon-bone and hamstring tendon grafts for anterior cruciate ligament reconstruction in male patients.

The aim of the study was to compare the results after arthroscopic anterior cruciate ligament (ACL) reconstruction using central-third, bone-patellar tendon-bone (BPTB Group) (n = 45) and four-strand semitendinosus/gracilis (ST/G Group) (n = 78) autografts in male patients. The type of study is non-randomised, prospective consecutive series. A consecutive series of 126 male patients, all with unilateral ACL ruptures, was included in the study. In both groups, interference screw fixation of the graft was used at both ends and 123/126 (97%) of the patients returned for the follow-up examination after a period of 25 (23-33) months. The pre-operative assessments in both groups were similar in terms of the Tegner activity level, the Lysholm knee scoring scale, KT-1000 measurements, one-leg-hop test and knee-walking test. A significant reduction in knee laxity as measured with the KT-1000 arthrometer, compared with the pre-operative assessments, was found in both groups (P < 0.001). No significant differences in the post-operative knee-laxity measurements were found between the groups. Both groups had a significantly improved functional outcome at follow-up in terms of the Lysholm knee scoring scale, Tegner activity level and one-leg-hop test. The BPTB Group had a significantly higher Tegner activity level at follow-up, compared with the ST/G Group (P = 0.02). Moreover, the patients in the BPTB Group were significantly more likely to have a Tegner activity level of 6 or above (P = 0.03). Otherwise, no significant differences were found between the two study groups at the 2-year follow-up. Two years after an ACL reconstruction, the two groups displayed no significant differences in terms of functional outcome and knee laxity. However, more patients in the BPTB Group returned to a higher Tegner activity level than that in the ST/G Group.

Adolescent↗

Early active extension after anterior cruciate ligament reconstruction does not result in increased laxity of the knee.

If permission of full active and passive extension immediately after an anterior cruciate ligament (ACL) reconstruction will increase the post-operative laxity of the knee has been a subject of discussion. We investigated whether a post-operative rehabilitation protocol including active and passive extension without any restrictions in extension immediately after an ACL reconstruction would increase the post-operative anterior-posterior knee laxity (A-P laxity). Our hypothesis was that full active and passive extension immediately after an ACL reconstruction would have no effect on the A-P laxity and clinical results up to 2 years after the operation. Twenty-two consecutive patients (14 men, 8 women, median age 21 years, range 17-41) were included. All the patients had a unilateral ACL rupture and no other ligament injuries or any other history of previous knee injuries. The surgical procedure was identical in all patients and one experienced surgeon operated on all the patients, using the bone-patellar tendon-bone autograft. The post-operative rehabilitation programme was identical in both groups, except for extension training during the first 4 weeks post-operatively. The patients were randomly allocated to post-operative rehabilitation programmes either allowing (Group A, n=11) or not allowing [Group B (30 to -10 degrees ), n=11] full active and passive extension immediately after the operation. They were evaluated pre-operatively and at 6 months and 2 years after the reconstruction. To evaluate the A-P knee laxity, radiostereometric analysis (RSA) and KT-1000 arthrometer (KT-1000) measurements were used, range of motion, Lysholm score, Tegner activity level, the International Knee Documentation Committee (IKDC) evaluation system and one-leg-hop test quotient were used. Pre-operatively, the RSA measurements revealed side-to-side differences in Group A of 8.6 mm (2.3-15.4), median (range) and in Group B of 7.2 mm (2.2-17.4) (n.s.). The corresponding KT-1000 values were for Group A, 2.0 mm (0-8.0) and Group B, 4.0 mm (0-10.0) (n.s.). At 2 years, the differences between the two groups were minimal, regardless of the method that had been used. The RSA measurements in Group A were 2.7 mm (0-10.7) and in Group B 2.8 (-1.8 to 9.5). The KT-1000 values were for Group A, 1.0 mm (-1.5 to 3.5), and for Group B, 0.5 mm (-1.0 to 4.0), without any significant differences between the groups. Nor did the Lysholm score, Tegner activity level, IKDC or one-leg-hop test differ. Early active and passive extension training, without any restrictions in extension, immediately after an ACL reconstruction using bone-patellar tendon-bone graft did not increase post-operative knee laxity up to 2 years after the ACL reconstruction.

Adolescent↗

The course of the patellar tendon after reharvesting its central third for ACL revision surgery: a long-term clinical and radiographic study.

The choice of the optimal graft for anterior cruciate ligament (ACL) revision surgery is still controversial. Reharvesting the patellar tendon has been suggested as one graft alternative. Our hypothesis was that in the long-term, ACL revision surgery using reharvested patellar tendon autografts would render a good clinical outcome and a normal patellar tendon at the donor site as seen on magnetic resonance imaging (MRI). Fourteen consecutive patients (five women, nine men), who underwent ACL revision surgery using reharvested ipsilateral patellar tendon grafts, were included in the study. They underwent bilateral MRI evaluations of the patellar tendon and were tested for clinical outcome 26 (20-35) and 115 months (102-127) after the revision procedure. On the second occasion, they also underwent standard weight-bearing X-ray examinations. The serial MRI evaluations revealed that the thickness of the patellar tendon at the donor site was significantly increased compared with the non-harvested, normal contralateral side and that the donor-site gap was still visible after 10 years. No significant differences were seen between the 2- and 10-year MRI evaluations. Standard weight-bearing X-ray examinations revealed signs of mild degenerative changes in all patients. Clinical results in terms of the Lysholm score, IKDC evaluation system, one-leg-hop test, KT-1000 laxity test and the knee-walking test revealed no significant differences between the 2- and 10-year assessments. In overall terms, the clinical results were considered to be poor on both occasions. The patellar tendon at the donor site had not normalised 10 years after the reharvesting procedure, as seen on MRI. Furthermore, the clinical results were poor after ACL revision surgery using reharvested patellar tendon autograft.

Adult↗

Evaluation of lower leg function in patients with Achilles tendinopathy.

Achilles tendinopathy is considered to be one of the most common overuse injuries in elite and recreational athletes. However, the effect that the Achilles tendinopathy has on patients' physical performance is still unclear. The purpose of this study was to evaluate if Achilles tendinopathy caused functional deficits on the injured side compared with the non-injured side in patients. A test battery comprised of tests for different aspects of muscle-tendon function of the gastrocnemius, soleus and Achilles tendon complex was developed to evaluate lower leg function. The test battery's test-retest reliability and sensitivity (the percent probability that the tests would demonstrate abnormal lower limb symmetry index in patients) were also evaluated. The test battery consisted of three jump tests, a counter movements jump (CMJ), a drop counter movement jump (drop CMJ) and hopping, and two strength tests, concentric toe-raises, eccentric-concentric toe-raises and toe-raises for endurance. The reliability was evaluated through a test-retest design on 15 healthy subjects. The test battery's sensitivity and possible functional deficits in patients with Achilles tendinopathy were evaluated on 42 patients (19 women and 23 men). An excellent reliability was found between test days 1-2 and 2-3 for all tests (ICC = 0.76-0.94) except for concentric toe-raise, test 2-3, which had fair reliability (ICC = 0.73). The methodological error ranged from 8 to 17%. There were significant differences (P = 0.001-0.049) between the non-injured (or least symptomatic) side and injured (most symptomatic) side for hopping, drop CMJ, concentric and eccentric-concentric toe-raises, and significant differences (P = 0.000-0.012) in the level of pain during CMJ, hopping, and drop CMJ. The sensitivity of the test battery at a 90% capacity was 88. Achilles tendinopathy causes not only pain and symptoms in patients but also apparent impairments in various aspects of lower leg muscle-tendon function as measured with the test battery. This test battery is reliable and able to detect differences in lower leg function between the injured or "most symptomatic" and non-injured or "least symptomatic" side in patients with Achilles tendinopathy. The test battery has higher demand on patients' function compared with each individual test.

Achilles Tendon↗

Biodegradable and metallic interference screws in anterior cruciate ligament reconstruction surgery using hamstring tendon grafts: prospective randomized study of radiographic results and clinical outcome.

BACKGROUND: The use of biodegradable screws in anterior cruciate ligament reconstruction has grown in popularity. PURPOSE: To compare the clinical and radiographic results in arthroscopically assisted anterior cruciate ligament reconstruction using 4-strand hamstring tendon grafts and either metallic (metal group) or biodegradable (PLLA group) interference screw fixation. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A randomized series of 77 patients, all with a unilateral anterior cruciate ligament rupture, was included in the study. The preoperative assessments in both groups were similar in gender, Tegner activity level, Lysholm score, KT-1000 arthrometer measurements, and single-legged hop test results. In both groups, interference screw fixation of the graft was used at both ends, and 68 of 77 (88%) patients returned for a radiographic examination at 6 and 24 months, respectively. RESULTS: At follow-up, no significant differences were found between the 2 groups in KT-1000 arthrometer laxity measurements, Tegner activity level, or Lysholm score. The PLLA group had a significantly better outcome in the single-legged hop test and the final International Knee Documentation Committee classification (P = .007 and P = .03, respectively). At 6 and 24 months after the index operation, the PLLA group displayed significantly larger drill holes on the radiographs than did the metal group on both the tibial (8.1 vs 6.6 mm at 6 months [P = .0007]; 6.0 vs 3.2 mm at 24 months [P < .0001]) and femoral sides (7.8 vs 5.6 mm at 6 months [P < .0001]; 6.3 vs 1.9 mm at 24 months [P < .0001]). CONCLUSION: There were significantly larger radiographically visible drill holes on both the tibial and femoral sides in the PLLA group compared with the metal group at 6 and 24 months. Clinical examination at 2 years revealed no major differences between the groups. The larger drill holes in the PLLA group did not correlate with inferior clinical results.

Absorbable Implants↗

KT-1000 records smaller side-to-side differences than radiostereometric analysis before and after an ACL reconstruction.

The KT-1000 and similar non-invasive arthrometers are used as a complement to clinical examination in the diagnosis of anterior cruciate ligament (ACL) rupture and during the follow-up after surgery. We compared the two methods, KT-1000 and Radiostereometric analysis (RSA), when used to measure anterior-posterior knee laxity (A-P laxity) in patients with ACL rupture, before and after the reconstruction of this ligament, in a prospective, comparative study. Twenty-two consecutive patients (14 men, 8 women) with a median age of 24 years (range 16-41) were studied. All the patients had a unilateral ACL rupture and an intact contralateral knee. The patients were operated on by one experienced surgeon using the bone-patellar tendon-bone (BTB) autograft. Preoperatively and 2 years after the reconstruction, all the patients were evaluated using KT-1000 and RSA measurements of A-P laxity. The side-to-side differences between the injured and the intact knees, that is, total A-P laxity for both knees, are presented. Preoperatively, the median side-to-side differences using the two methods (KT-1000/RSA) were 4.0 (0-10)/7.4 mm (2.2-17.4) (P<0.0001). The total A-P laxity on the injured side was 11.0 (6.0-18.0)/10.9 mm (6.2-19.6) (n.s), while it was 8.0 (6.0-10.0)/3.1 mm (0.2-8.6) on the intact side (P<0.0001). A side-to-side difference of more than 3.0 mm was defined as the cut-off value for indicating ACL rupture. Using the KT-1000, 11 of 22 (50%) patients had a cut-off value above 3.0 mm, while the corresponding figure for RSA was 21/22 (95%) patients. At the 2-year follow-up, the median side-to-side differences using the two methods (KT-1000/RSA) were 0.5 (-1.5 to 4.0)/2.8 mm (-1.8 to 10.7) (P<0.0001). The total A-P laxity on the operated side was 9.5 (7.5-14.0)/6.5 mm (2.4-14.1) (P<0.0001). We conclude that the KT-1000 recorded significantly smaller side-to-side differences than did the RSA, both before and after the reconstruction of the ACL using a BTB autograft. Before it was mainly an effect of larger A-P laxity recordings with KT-1000 on the intact side, and after the reconstruction, the KT-1000 still recorded larger A-P laxity on the intact side and also larger A-P laxity on the reconstructed side than RSA.

Adolescent↗

A test battery for evaluating hop performance in patients with an ACL injury and patients who have undergone ACL reconstruction.

The purpose of this study was to develop a test battery of hop tests with high ability to discriminate (i.e. high test-retest reliability, sensitivity, specificity and accuracy) between the hop performance of the injured and the uninjured side in patients with an ACL injury and in patients who have undergone ACL reconstruction. Five hop tests were analysed: three maximum single hop tests and two hop tests while developing fatigue. Fifteen healthy subjects performed the five hop tests on three separate occasions in a test-retest design. Thirty patients, mean 11 months after an ACL injury and 35 patients, mean 6 months after ACL reconstruction were tested. ICC values ranged from 0.85 to 0.97 for the five hop tests, indicating that all the tests had high test-retest reliability. Sixty-seven percent to 100% of the healthy subjects had normal symmetry (i.e. <10% side-to-side difference) in the five hop tests. Abnormal symmetry in the five hop tests ranged from 43 to 77% for patients with an ACL injury and from 51 to 86% for patients who had undergone ACL reconstruction respectively. The three tests with the highest ability to discriminate hop performance were chosen for the test battery; they were the vertical jump, the hop for distance and the side hop. The test battery revealed a high level of sensitivity and accuracy in patients with an ACL injury (87 and 84%) and in patients who had undergone ACL reconstruction (91 and 88%), when at least one of the three tests was classified as abnormal. To summarise, the test battery consisting of both maximum single hop performances: the vertical jump and the hop for distance and hop performance while developing fatigue: the side hop, produced high test-retest reliability, sensitivity and accuracy. Further, the test battery produced higher values compared with any of the three hop tests individually revealing that only one out of ten patients had restored hop performance 11 months after an ACL injury and 6 months after ACL reconstruction. It is concluded that this test battery showed a high ability to discriminate between the hop performance of the injured and the uninjured side both in patients with an ACL injury and in patients who have undergone ACL reconstruction.

Adult↗

Development of a strength test battery for evaluating leg muscle power after anterior cruciate ligament injury and reconstruction.

A more sports-specific and detailed strength assessment has been advocated for patients after anterior cruciate ligament (ACL) injury and reconstruction. The purpose of this study was to develop a test battery of lower extremity strength tests with high ability to discriminate between leg power development on the injured and uninjured sides in patients after ACL injury and in patients who have undergone ACL reconstruction. Twenty-three patients were tested 6 months after ACL injury and 44 patients were tested 6 months after ACL reconstruction. Twenty-four of the 44 patients were operated on using a hamstrings graft and 20 patients were operated on using a patellar tendon graft. All the patients performed a test battery of three strength tests for each leg in a randomised order. The three strength tests were chosen to reflect quadriceps and hamstring muscular power in a knee-extension and a knee-flexion test (open kinetic chain) and lower-extremity muscular power in a leg-press test (closed kinetic chain). There was a higher sensitivity for the test battery to discriminate abnormal leg power compared with any of the three strength tests individually. Nine out of ten patients after ACL reconstruction and six out of ten of the patients after ACL injury exhibited abnormal leg power symmetry using the test battery. Thus, this test battery had high ability in terms of discriminating between the leg power performance on the injured and uninjured side, both in patients with an ACL injury and in patients who have undergone ACL reconstruction. It is concluded that a test battery consisting of a knee-extension, knee-flexion and leg-press muscle power test had high ability to determine deficits in leg power 6 months after ACL injury and reconstruction. Only a minority of the patients had restored leg muscle power. The clinical relevance is that the test battery may contribute to the decision-making process when deciding whether and when patients can safely return to strenuous physical activities after an ACL injury or reconstruction.

Adult↗

A prospective, randomized, clinical and radiographic study after arthroscopic Bankart reconstruction using 2 different types of absorbable tacks.

PURPOSE: The aim of the study was to compare the clinical and radiographic results after arthroscopic Bankart reconstruction using 2 different types of absorbable implant. TYPE OF STUDY: Randomized controlled trial. METHODS: A randomized series of 40 patients who had recurrent, unidirectional, post-traumatic shoulder instability were included in the study. All patients underwent an arthroscopic Bankart reconstruction involving either polygluconate co-polymer (PGACP group, n = 20) or self-reinforced poly-L-lactic acid polymer (PLLA group, n = 20) tack implants. The patients underwent clinical and radiographic assessments preoperatively and at 2 years. Additional radiographic assessments were performed at 6 months. RESULTS: Preoperatively, the study groups were comparable in terms of demographics as well as clinical parameters. One patient in each group had a redislocation (5%) during the follow-up period of 2 years. No subluxations were registered. No statistically significant differences were found between the study groups in terms of strength in abduction, range of motion, and Rowe or Constant scores. There was a significant increase in degenerative changes during the follow-up period in both study groups (P = .004). However, no significant differences in degenerative changes were registered between the study groups either preoperatively or at the 2-year follow-up. There were no significant differences in the radiographic visibility of the drill holes used for the absorbable implants between the study groups at the 6-month assessment. However, at the 2-year assessment, the radiographic visibility of the drill holes was significantly greater (P = .004) in the patients in the PLLA group than those in the PGACP group. At the 2-year assessment, no correlation was found between the appearance of the drill holes and the degenerative findings (PGACP group, rho = 0.44; PLLA group, rho = 0.42). CONCLUSIONS: Two years after arthroscopic Bankart reconstruction using either PGA polymer or PLA polymer implants, the overall clinical results were comparable. Radiographic assessments revealed that the degenerative changes increased in both study groups during the follow-up period. Furthermore, the visibility of the drill holes on the 2-year radiographs was greater after using PLLA implants than after using PGACP implants. LEVEL OF EVIDENCE: Level I.

Absorbable Implants↗

Scoring systems for evaluating ankle function.

Each of the seven systems described has advantages and drawbacks that consist of ease or difficulty of application, accuracy, validity, and availability. This article should contribute to make these systems better known and easier to apply, and thus, will encourage their use in clinical practice. [Fig.: see text].

Ankle↗

Management of acute ligament injuries of the ankle.

Ligament injuries of the ankle are common and troublesome. Management may seem easy, but residual symptoms ae common. Grade III injuries still generate controversy in terms of the best management available, and more studies are needed when it comes to early mobilization, cast immobilization, or surgery. Even the three Cohrane reviews published to date are not conclusive.

Acute Disease↗

A prospective comparison of bone-patellar tendon-bone and hamstring grafts for anterior cruciate ligament reconstruction in female patients.

The aim of the study is to compare the results after arthroscopic anterior cruciate ligament (ACL) reconstruction using central-third, bone-patellar tendon-bone (BTB group) (n = 28) and four-strand semitendinosus/gracilis (ST/G group) (n = 31) autografts in female patients. The type of study was non-randomised prospective consecutive series. A consecutive series of 61 female patients, all with unilateral ACL ruptures, was included in the study. In both groups, interference screw fixation of the graft was used at both ends, and 59/61 (97%) of the patients returned for the follow-up examination after a period of 26 (23-31) months. The pre-operative assessments in both groups were similar in terms of the Lysholm score, KT-1000 measurements, one-leg-hop test, and knee-walking test. At the 2-year follow-up, the knee-walking test was significantly worse in the BTB group than in the ST/G group (P = 0.003). Furthermore, the knee-walking test was significantly worse at follow-up than pre-operatively in the BTB group (P < 0.005). The corresponding finding was not made in the ST/G group. A reduction in knee laxity compared with the pre-operative assessments was found in both groups. No significant difference in the post-operative knee laxity measurement was found between the groups. A significant increase in activity level and subjective scores was found in both groups compared with pre-operative values, without any significant differences between the groups. Two years after ACL reconstruction, the groups displayed no significant differences in terms of functional outcome and knee laxity. However, the use of ST/G autografts rendered significantly less discomfort during the knee-walking test than the use of BTB autografts.

Adolescent↗

Cross-cultural adaptation of the VISA-A questionnaire, an index of clinical severity for patients with Achilles tendinopathy, with reliability, validity and structure evaluations.

BACKGROUND: Achilles tendinopathy is considered to be one of the most common overuse injuries in elite and recreational athletes and the recommended treatment varies. One factor that has been stressed in the literature is the lack of standardized outcome measures that can be used in all countries. One such standardized outcome measure is the Victorian Institute of Sports Assessment - Achilles (VISA-A) questionnaire, which is designed to evaluate the clinical severity for patients with Achilles tendinopathy. The purpose of this study was to cross-culturally adapt the VISA-A questionnaire to Swedish, and to perform reliability, validity and structure evaluations. METHODS: Cross-cultural adaptation was performed in several steps including translations, synthesis of translations, back translations, expert committee review and pre-testing. The final Swedish version, the VISA-A Swedish version (VISA-A-S) was tested for reliability on healthy individuals (n = 15), and patients (n = 22). Tests for internal consistency, validity and structure were performed on 51 patients. RESULTS: The VISA-A-S had good reliability for patients (r = 0.89, ICC = 0.89) and healthy individuals (r = 0.89-0.99, ICC = 0.88-0.99). The internal consistency was 0.77 (Cronbach's alpha). The mean [95% confidence interval] VISA-A-S score in the 51 patients (50 [44-56]) was significantly lower than in the healthy individuals (96 [94-99]). The VISA-A-S score correlated significantly (Spearman's r = -0.68) with another tendon grading system. Criterion validity was considered good when comparing the scores of the Swedish version with the English version in both healthy individuals and patients. The factor analysis gave the factors pain/symptoms and physical activity CONCLUSION: The VISA-A-S questionnaire is a reliable and valid instrument and comparable to the original version. It measures two factors: pain/symptoms and physical activity, and can be used in both research and the clinical setting.

Achilles Tendon↗

A long-term serial histological evaluation of the patellar tendon in humans after harvesting its central third.

It is previously known that the patellar tendon does not normalise histologically in the short term after harvesting its central third. The aim of the study was to obtain long-term serial biopsies from the central and peripheral parts of the patellar tendon after the harvesting procedure. Our hypothesis was that in the long term after harvesting its central third, the patellar tendon does not regain normal histological appearance. Seventeen consecutive patients, who had undergone anterior cruciate ligament reconstruction using patellar tendon autografts, were included. Percutaneous biopsies were obtained under ultrasonographic guidance 27 (24-29) months and 71 (68-73) months after the index procedure, respectively. The sections were stained with haematoxylin and eosin. The biopsies were evaluated using light microscope. Both at 27 months and 71 months, the fibre structure was deteriorated and the vascularity and cellularity were increased compared with normal tendon. This was seen in both the central and peripheral parts of the tendon. In conclusion, nearly 6 years after harvesting its central third, the patellar tendon had still not normalised histologically, neither in the central nor peripheral parts of the tendon.

Adolescent↗

A prospective randomized comparison of bone-patellar tendon-bone and hamstring grafts for anterior cruciate ligament reconstruction.

PURPOSE: The aim of this study was to compare the results after arthroscopic anterior cruciate ligament (ACL) reconstruction using central-third, bone-patellar tendon-bone (BPTB group), 3-strand semitendinosus (ST group), or 4-strand semitendinosus/gracilis (ST/G group) autografts. TYPE OF STUDY: Prospective randomized trial. METHODS: A randomized series of 134 patients, all with unilateral ACL rupture was included in the study. In all 3 groups, interference screw fixation of the graft was used at both ends and 125 of 134 (93%) of the patients returned for the follow-up examination after 26 months (range, 20 to 43 months). The preoperative assessments in all 3 groups were similar in terms of gender, Tegner activity level, Lysholm score, KT-1000 measurements, 1-leg hop test, and the knee-walking test. RESULTS: At follow-up, the knee-walking test was significantly worse in the BPTB group than in the ST group (P = .0004) and ST/G group (P < .0001). Furthermore, the knee-walking test was significantly worse at follow-up than preoperatively in the BPTB group (P < .0001). The corresponding findings were not made in the other 2 groups. A significant reduction in knee laxity and an increase in activity level compared with the preoperative assessments were found in all 3 groups, without any significant differences between the groups. CONCLUSIONS: Two years after ACL reconstruction, the use of ST and ST/G autografts rendered significantly less discomfort during the knee-walking test than the use of BPTB autografts. However, in terms of functional outcome and knee laxity, the groups displayed no significant differences. LEVEL OF EVIDENCE: Level I.

Adolescent↗

Outcome and risk factors after anterior cruciate ligament reconstruction: a follow-up study of 948 patients.

PURPOSE: The aim of the study was to assess the outcome and risk factors after anterior cruciate ligament (ACL) reconstruction in a large group of patients. TYPE OF STUDY: Case series. METHODS: Included in this retrospective study were 948 patients (323 female, 625 male) with a symptomatic unilateral ACL rupture, who underwent arthroscopic reconstruction using patellar tendon autograft and interference screw fixation at 3 Swedish hospitals. The median age of the patients at the time of the index operation was 26 years (range, 14 to 53 years). The patients underwent surgery at a median of 12 months (range, 0.5 to 360 months) after their injury. Independent physiotherapists performed the follow-up examinations at a median of 32 months (range, 21 to 117 months) postoperatively. RESULTS: Of the 948 patients, 550 (58%) underwent meniscal surgery before, during, or after the ACL reconstruction. The median Tegner activity level was 8 (range, 2-10) before injury, 3 (range, 0-9) preoperatively, and 6 (range, 1-10) at follow-up (P < .0001 preoperative v follow-up). At follow-up, the median Lysholm score was 90 points (range, 14-100), the median KT-1000 anterior side-to-side laxity difference was 1.5 mm (range, -6 to 13 mm), and the median 1-leg hop test quotient was 95% (0% to 167%) compared with the contralateral normal side. At follow-up, 69.3% of the patients were classified as normal or nearly normal according to the International Knee Documentation Committee evaluation system. However, 36% of the patients were unable to or had severe problems performing the knee-walking test. Inferior results correlated with increased time period between the index injury and reconstruction and concomitant joint damage found at the index operation. CONCLUSIONS: Overall, the results were good after ACL reconstruction using patellar tendon autograft and interference screw fixation. Concomitant joint damage and a long time period between the injury and reconstruction are major risk factors for inferior outcome after ACL reconstruction. LEVEL OF EVIDENCE: Level IV, case series.

Adolescent↗