Search PubMed⌕ Search

Biomedical subjects

John P Nolan

Publications and source records attributed to John P Nolan.

5 recordsLinked to original sources

Development and characterization of Ni-NTA-bearing microspheres.

BACKGROUND: For ease of purification, proteins are often expressed with a short affinity sequence of five or six adjacent histidine residues (His-tag). This His-tag binds to the metal of metal chelator complexes such as Ni(2+)-nitrilotriacetic acid (Ni-NTA) or -iminodiacetic acid (Ni-IDA). Chromatography resins bearing covalently attached metal chelator complexes are used widely for the easy affinity purification of His-tagged proteins or peptides. Because Ni-NTA microspheres were not commercially available at the beginning of our studies, we prepared and characterized such microspheres to immobilize His-tagged proteins and study their interactions. Our microspheres are of three types: (a) metal chelator complexes bound covalently to polystyrene microspheres, (b) metal chelator complexes bound covalently to silica microspheres, and (c) lipid-linked metal chelator complexes adsorbed to silica microspheres forming self-assembled bilayer membranes where the metal chelators have lateral mobility. METHODS: The microspheres bearing covalently attached Ni-chelator were synthesized by reacting a primary amine-bearing Ni-NTA ligand with carboxy-functionalized microspheres and then loading with Ni(2+). Microspheres with laterally mobile metal chelator were made by incubating glass microspheres with liposomes containing phosphatidylcholine (PC) and the metal chelating lipid 1,2-dioleoyl-sn-glycero-3-[(N (5-amino-1-carboxypentyl)iminodiacetic acid)succinyl]. Binding of a His-tagged enhanced green fluorescent protein (EGFP) was used to characterize these microspheres by flow cytometry for their specificity, sensitivity, capacity and stability. RESULTS: While all micospheres specifically bind His-tagged proteins, the conditions to achieve this are different for the polystyrene- and silica-based spheres. All three types of microspheres bind His-EGFP with saturation occurring at 30-50 nM and an apparent avidity (concentration of half-maximal binding) of approximately 1 to 2 x 10(-8) M at pH 7.4. Binding of His-EGFP is inhibited by imidazole or ethylene-diaminetetraacetic acid (EDTA). Polystyrene Ni-NTA microspheres showed significant nonspecific binding as measured by binding in the presence of imidazole or EDTA or by binding of fluorescent proteins lacking a His-tag. This nonspecific binding of proteins to and aggregation of polystyrene spheres could only be prevented by the inclusion of low concentrations of Tween 20, but not by including bovine serum albumin (BSA), polyethylene glycols, or polyvinylpyrrolidones as blocking agents. In contrast, silica-based microspheres with covalently attached Ni-NTA or silica microspheres bearing adsorbed bilayers that contain Ni-NTA-lipid showed little nonspecific binding in the presence of BSA. Our results on the stability of immobilization indicate that washing destabilizes the binding of His-tagged proteins to Ni-NTA microspheres. This binding consists of two interactions of different affinities. We also demonstrate that limited multiplexed analysis with differently sized silica microspheres bearing the Ni-NTA-lipid is feasible. CONCLUSIONS: The microspheres described are well suited to selectively immobilize His-tagged proteins to analyze their interactions by flow cytometry. The affinity and kinetic stability of the interaction of His-tagged proteins with Ni-NTA are insufficient to use Ni-NTA microspheres in multiplexed analysis formats where different His-tagged proteins are bound to distinct microspheres. Improvements towards this end (improved chelators and/or improved affinity tags) are critical for extending the use of this method. We are currently working on novel chelators to strengthen the stability of immobilization of His-tagged proteins to surfaces. Such improvements would greatly enhance the analysis of interactions of immobilized His-tagged proteins and could make the development of microsphere-based arrays with His-tagged protein/antibody possible.

Binding Sites↗

Analysis of cholera toxin-ganglioside interactions by flow cytometry.

Cholera toxin entry into mammalian cells is mediated by binding of the pentameric B subunit (CTB) to ganglioside GM(1) in the cell membrane. We used flow cytometry to quantitatively measure in real time the interactions of fluorescently labeled pentameric cholera toxin B-subunit (FITC-CTB) with its ganglioside receptor on microsphere-supported phospholipid membranes. A model that describes the multiple steps of this mode of recognition was developed to guide our flow cytometric experiments and extract relevant equilibrium and kinetic rate constants. In contrast to previous studies, our approach takes into account receptor cross-linking, an important feature for multivalent interactions. From equilibrium measurements, we determined an equilibrium binding constant for a single subunit of FITC-CTB binding monovalently to GM(1) presented in bilayers of approximately 8 x 10(7) M(-1) while that for binding to soluble GM(1)-pentasaccharide was found to be approximately 4 x 10(6) M(-1). From kinetic measurements, we determined the rate constant for dissociation of a single site of FITC-CTB from microsphere-supported bilayers to be (3.21 +/- 0.03) x 10(-3) s(-1), and the rate of association of a site on FITC-CTB in solution to a GM(1) in the bilayer to be (2.8 +/- 0.4) x 10(4) M(-1) s(-1). These values yield a lower estimate for the equilibrium binding constant of approximately 1 x 10(7) M(-1). We determined the equilibrium surface cross-linking constant [(1.1 +/- 0.1) x 10(-12) cm(2)] and from this value and the value for the rate constant for dissociation derived a value of approximately 3.5 x 10(-15) cm(2) s(-1) for the forward rate constant for cross-linking. We also compared the interaction of the receptor binding B-subunit with that of the whole toxin (A- and B-subunits). Our results show that the whole toxin binds with approximately 100-fold higher avidity than the pentameric B-subunit alone which is most likely due to the additional interaction of the A(2)-subunit with the membrane surface. Interaction of cholera toxin B-subunit and whole cholera toxin with gangliosides other than GM(1) revealed specific binding only to GD1(b) and asialo-GM(1). These interactions, however, are marked by low avidity and require high receptor concentrations to be observed.

Animals↗

Nozzle design parameters and their effects on rapid sample delivery in flow cytometry.

BACKGROUND: Rapid kinetic and high throughput flow cytometry are emerging as valuable tools in biotechnology research applications ranging from mechanistic analysis of molecular assemblies to high throughput screening. Many of these new applications have been made possible by improved sample delivery capabilities, focusing increased attention on fluidic issues associated with rapid sample delivery. METHODS: Using basic fluidic premises, we derived a model that predicted the effect of nozzle parameters during rapid sample delivery. We tested the model using the rapid mix flow cytometer and modifications were made to the equipment to optimize performance. RESULTS: The model predicted that shorter nozzles with wide exit orifices decrease the delay before initial particle analysis and the fluidic stabilization time. Experimental results confirmed this prediction and model-based modifications allowed analysis of particles within 55 ms or 600 ms after mixing, with or without electronic gating, respectively. CONCLUSIONS: The model along with modifications to commercial equipment will allow rapid mix flow cytometry to analyze reactions in time frames threefold shorter than previously possible. The model allows for nozzle design predictions that should allow for analysis in the millisecond time frame. Furthermore, these findings are general for all rapid delivery applications, including high throughput flow cytometry.

Automation↗

Suspension array technology: evolution of the flat-array paradigm.

Suspension arrays of microspheres analyzed using flow cytometry offer a new approach to multiplexed assays for large-scale screening applications. By optically encoding micron-sized polymer particles, suspension microarrays can be created to enable highly multiplexed analysis of complex samples. Each element in the array is comprised of a subpopulation of particles with distinct optical properties and each array element bears a different surface receptor. Nucleic acids, proteins, lipids or carbohydrates can serve as receptors to support the analysis of a wide range of biomolecular assemblies, and applications in genomic and proteomic research are being developed. Coupled with recent innovations for rapid serial analysis of samples, molecular analysis with microsphere arrays holds significant potential as a general analysis platform for both research and clinical applications.

Directed Molecular Evolution↗

Flow cytometric analysis of ligand-receptor interactions and molecular assemblies.

Flow cytometers make homogeneous real-time measurements of ligand-receptor interactions and, simultaneously, the physiological responses of cells. Their multiparameter capabilities are also useful in resolving multicomponent assemblies or in developing multiplexed assays. Recent advances suggest that these approaches can be extended in several important ways. Sample delivery in the millisecond time domain is applicable to the analysis of complex binding kinetics and reaction mechanisms. The homogeneous discrimination of free components and particle-based assemblies can be extended into the micromolar concentration range. Measurements can be made of molecular assemblies among proteins, DNA, RNA, lipids, and carbohydrates on beads. The topography and assembly of components within cells can be evaluated with resonance energy transfer. Temperature dependence can be evaluated with Peltier temperature control. Many assembly endpoints can be assessed through new tools for high-throughput flow cytometry using plate-based assay formats and small volume samples.

Animals↗