Comparison of magnetocardiography and electrocardiography: a study of automatic measurement of dispersion of ventricular repolarization.

AIMS: There is some dispute over the clinical significance of dispersion of ventricular repolarization measurements from the electrocardiogram. Recent studies have indicated that multichannel magnetocardiograms (MCGs), which non-invasively measure cardiac magnetic field strength from many sites above the body surface, may provide independent information from ECGs about ventricular repolarization dispersion. For this study, magnetocardiography and electrocardiography were compared from automatic measurements of dispersion of ventricular repolarization. METHODS AND RESULTS: Dispersion of ventricular repolarization time was determined in MCGs and standard ECGs recorded simultaneously from 27 healthy volunteers and 22 cardiac patients. Two automatic techniques were used to determine the interval of ventricular repolarization. There were significant differences in ventricular dispersion between ECG and MCG measurements, with multichannel MCG greater than ECG by 52 (47) ms [mean (SD)] (P<0.00001) and 12-channel MCG greater by 17 (40) ms (P<0.004) across techniques and all subjects. Magnetocardiograms had the greater discriminating power between normal and cardiac patients with differences of 46 (18) ms (P<0.017) for multichannel MCG and 44 (16) ms (P<0.005) for 12-channel MCG, compared with 16 (7) ms (P<0.04) for ECG. CONCLUSION: Magnetocardiography has the power to discriminate regional cardiac conduction differences.

Electrocardiography↗

Adenosine test in the diagnosis of unexplained syncope: marker of conducting tissue disease or neurally mediated syncope?

Adenosine test (supine administration of a 20 mg intravenous bolus with electrocardiographic and blood pressure monitoring) has been endorsed by the European Society of Cardiology guidelines on syncope management as an 'experimental' test in the diagnosis of unexplained syncope. The test is quick and cheap, but there is no consensus as to what condition, if any, the adenosine test is exposing, with conducting tissue disease and neurally mediated syncope proposed by various authors. In this article, we review the possible mechanisms underlying a positive adenosine test, its safety, and a comprehensive examination of the literature supporting each of the putative causal diagnoses.

Adenosine↗

Surface atrial frequency analysis in patients with atrial fibrillation: assessing the effects of linear left atrial ablation.

INTRODUCTION: Our group has shown previously that measurements of atrial frequency can be obtained from surface 12-lead ECG recordings of patients during atrial fibrillation (AF), using a combination of principal component and Fourier transform algorithms. Such measurements are reproducible over time and change with drug manipulation of the arrhythmia. AIMS: To determine whether linear left atrial ablation, using a combination of "roof" and "mitral isthmus" lines results in changes in surface atrial frequency during AF and to assess the contribution of each individual line when sited sequentially. METHODS AND RESULTS: Computerized recordings from 26 patients, who had undergone linear ablation procedures for AF, were reviewed. The atrial signal was extracted from the 12-lead ECG data by principal component analysis and the main frequency component identified using Fourier analysis. Atrial frequency before and after these two standard ablation lines was compared. Atrial frequency decreased significantly after the combination of roof and mitral isthmus lines (5.66 vs 5.15 Hz) and when either roof (5.61 vs 5.13 Hz) or mitral isthmus (5.89 vs 5.75 Hz) lines were sited first. However, only the roof line led to a significant reduction in atrial frequency when sited second (5.64 vs 5.49 Hz). CONCLUSIONS: Measurements of atrial frequency can be obtained from surface 12-lead ECG recordings during AF and change as predicted in response to linear left atrial ablation. This technique may be useful in assessing antiarrhythmic treatments for AF.

Adult↗

Surface atrial frequency analysis in patients with atrial fibrillation: a tool for evaluating the effects of intervention.

INTRODUCTION: The aims of this study were to evaluate (1) principal component analysis as a technique for extracting the atrial signal waveform from the standard 12-lead ECG and (2) its ability to distinguish changes in atrial fibrillation (AF) frequency parameters over time and in response to pharmacologic manipulation using drugs with different effects on atrial electrophysiology. METHODS AND RESULTS: Twenty patients with persistent AF were studied. Continuous 12-lead Holter ECGs were recorded for 60 minutes, first, in the drug-free state. Mean and variability of atrial waveform frequency were measured using an automated computer technique. This extracted the atrial signal by principal component analysis and identified the main frequency component using Fourier analysis. Patients were then allotted sequentially to receive 1 of 4 drugs intravenously (amiodarone, flecainide, sotalol, or metoprolol), and changes induced in mean and variability of atrial waveform frequency measured. Mean and variability of atrial waveform frequency did not differ within patients between the two 30-minute sections of the drug-free state. As hypothesized, significant changes in mean and variability of atrial waveform frequency were detected after manipulation with amiodarone (mean: 5.77 vs 4.86 Hz; variability: 0.55 vs 0.31 Hz), flecainide (mean: 5.33 vs 4.72 Hz; variability: 0.71 vs 0.31 Hz), and sotalol (mean: 5.94 vs 4.90 Hz; variability: 0.73 vs 0.40 Hz) but not with metoprolol (mean: 5.41 vs 5.17 Hz; variability: 0.81 vs 0.82 Hz). CONCLUSION: A technique for continuously analyzing atrial frequency characteristics of AF from the surface ECG has been developed and validated.

Aged↗

Effect of mitral valve repair/replacement surgery on atrial arrhythmia behavior.

BACKGROUND AND AIMS OF THE STUDY: Few data have been published on the effects of mitral valve surgery on atrial rhythm. The study aims were to determine the effects of surgery on: (i) persistence of atrial fibrillation (AF); (ii) measures of left atrial and ventricular dimensions; and (iii) ECG P-wave duration. METHODS: A retrospective case-note review of 92 patients with chronic mitral regurgitation was undertaken. Variables determined included prevalence and duration of AF; incidence of new-onset or persistence of AF after surgery; rhythm changes in relation to age, gender, left atrial and ventricular dimensions and function, anti-arrhythmic drug usage and ECG P-wave duration in sinus rhythm prior to surgery. RESULTS: Only 4/47 (8.5%) patients with any history of AF before surgery were in sinus rhythm at six months after surgery. All 28 patients with persistent AF for >12 months and 41/45 (91%) in sinus rhythm before surgery retained these rhythms after surgery. The left atrial dimension was decreased after surgery, in the whole group (51.3 +/- 9.0 versus 48.4 +/- 9.5 mm; p = 0.011) and in the subgroup in sinus rhythm, but not in the subgroup in AF. The left ventricular end-diastolic dimension decreased in the group as a whole (60.6 +/- 6.2 versus 53.0 +/- 8.7 mm; p = 0.0001) and in both subgroups after surgery. In 24 patients with 12- lead ECGs in sinus rhythm before and three months after surgery, P-wave duration remained unchanged. However, this measure decreased in the 18 patients in sinus rhythm consistently, but increased in the six patients continuing to have paroxysmal AF after surgery. CONCLUSION: Mitral valve surgery alone restored sinus rhythm in only 8.5% of patients with any previous history of AF. Concomitant anti-arrhythmic procedures should be considered for all patients with AF who undergo mitral valve surgery.

Aged↗

Dynamic alterations in right atrial activation during atrial fibrillation.

Atrial fibrillation (AF) is usually considered to be a disorganized rhythm. However, several reports have described areas of organized right atrial (RA) activation during AF. We describe a patient with focal paroxysmal AF with a consistent pattern of organized RA activity despite typically disorganized left atrial activity. The sequence of RA activation varied, depending on which pulmonary vein foci initiated the AF.

Atrial Fibrillation↗

Standardized stimulation protocol to predict the long-term success of radiofrequency ablation of postinfarction ventricular tachycardia.

BACKGROUND: The ability to predict the success of radiofrequency ablation (RFA) is an essential step in the management of ventricular tachycardia (VT) in patients with ischemic heart disease. METHODS: This study tested a standardized programmed stimulation protocol and pre-specified definitions of procedural outcome. Consecutive patients referred for RFA of delayed post infarction VT were enrolled. Programmed stimulation was performed at the beginning and the end of an RFA procedure, and consisted of an 8 beat drive followed by up to 5 extrastimuli. Immediate success was defined as no inducible monomorphic VT, and a modified result was defined as the inducibility of VT with > 2 extrastimuli beyond those required at baseline. Procedural failure was defined when these criteria were not met. Recurrences of sustained VT and arrhythmic deaths were monitored during long-term follow-up. RESULTS: The study enrolled 112 patients. Immediate procedural success was achieved in 38%, a modified result in 34%, and procedural failure in 28% of patients. During a mean follow-up of 78 +/- 16 months, recurrent sustained VT was observed in 25 patients. VT recurrence was 3% (3/79) in patients with a successful or modified result, compared with 67% (22/33) in those who had undergone unsuccessful procedures (P < 0.001). CONCLUSIONS: This standardized stimulation protocol and definitions of procedural success, enabled us to predict with high accuracy a VT recurrence-free long-term follow-up. This may have implications in recommending devices or other treatments after RFA for postinfarction VT.

Adult↗

Comparison of automatic repolarization measurement techniques in the normal magnetocardiogram.

Multichannel MCG noninvasively measures cardiac magnetic field strength from many sites at the body surface, potentially providing useful regional information about ventricular repolarization. Previous work on ECGs has shown that automatic techniques for repolarization measurement are better than manual measurement at discriminating patients with cardiac conditions from normal subjects. Although automatic repolarization measurement techniques have been quantified for ECGs, no comparative data exists for the MCG. In this study four different automatic repolarization (QT) interval techniques for detecting T wave end in the MCG were compared. The influence of MCG filtering on the automatic algorithms was also quantified. MCGs were obtained at 49 sites over the heart from 23 normal subjects. Automatic measurements of the repolarization (QT) interval were made following the addition of different high pass (0.25, 0.5, 1 Hz) and low pass (100, 60, 40, 30 Hz) filters. There were consistent differences between automatic techniques in the unfiltered data amounting to greatest mean difference of 52.3 ms. Low pass filtering significantly increased the automatic repolarization (QT) interval relative to unfiltered measurement by 6.5 (3.2) ms (mean SD) for 100 Hz, 6.0 (3.0) ms for 60 Hz, 8.1 (3.2) ms for 40 Hz, and 8.8 (3.1) ms for 30 Hz across all techniques. High pass filtering significantly decreased the value by -2.6 (6.0) ms for 0.25 Hz, -5.5 (5.3) ms for 0.5 Hz, and -17.1 (7.8) ms for 1 Hz. Automatic measurements of repolarization (QT) in the MCG differ between techniques and are influenced by filtering. These effects should be considered when comparing results.

Analysis of Variance↗

P wave morphology during spontaneous and paced pulmonary vein activity: differences between patients with atrial fibrillation and normal controls.

P wave morphology (PWM) has been used to predict the location of ectopic foci responsible for triggering atrial fibrillation (AF). With bi-atrial mapping, this study examined PWM during spontaneous ectopy and during pulmonary vein (PV) pacing, comparing the results with published algorithms in 40 AF patients and 15 controls. PWM during PV pacing is similar to spontaneous ectopy, if performed at similar coupling intervals. PWM during ectopic activity from the PVs is affected by cycle length and the presence of underlying atrial electrical and structural abnormalities. Changes in PWM during decremental pacing were observed in 5% of controls but in over 25% of persistent AF patients. The algorithms are accurate in over 90% of controls and paroxysmal AF patients with normal atria, but less than 60% in those with persistent AF or electrical or structural atrial abnormalities. The accuracy of non-invasive localization of arrhythmogenic PV is limited.

Adult↗

Atrioventricular block and problems with atrioventricular conduction.

This chapter has summarized briefly the current state of our knowledge on the incidence, etiology, presentation, investigation, and management of patients with AV block. The scope of the material covered has been widened intentionally to include a plethora of AV-conduction abnormalities because of the increases in the understanding of their clinical importance and contribution to left ventricular dysfunction. Under this heading, the critical importance of heart rate, maintenance of AV synchrony, and the sequence of ventricular activation and relaxation have been introduced and summarized briefly. The authors make a strong plea that, in the future, the reader consider AV-conduction abnormalities to be the parent topic, with the more-traditional, narrower subject of AV block forming a subunit thereof.

Aged↗

Errors in repolarization measurement using magnetocardiography.

Multichannel magnetocardiography (MCG) noninvasively measures variations in magnetic field strength from many sites at the body surface, potentially providing useful regional information about ventricular repolarization. MCGs contain features similar to ECGs, and although errors associated with repolarization measurement have been quantified for ECGs, no comparative data exists for MCGs. In this study, errors in manual measurement of repolarization interval in the MCG were determined. Sixteen MCG channels and three ECG leads were recorded simultaneously in eight healthy subjects. Each recording was displayed in a random order on a computer screen, in presentations with different noise levels, time display widths, and amplitude display heights. In total, manual measurement of repolarization intervals in 2,048 (eight subjects x 16 channels x eight presentations x two repeats) MCGs were made by each of four analysts. Measured repolarization intervals were reduced by 3 ms when noise was added and by a further 3 ms when this noise was doubled. Intervals were shortened by 9 ms when the time display width was doubled and by a further 10 ms when the display width was doubled again. Measurements increased by 7 ms for a doubling of amplitude display height, equivalent to a doubling of T wave height. There were also consistent differences between analysts; amounting to a greatest mean difference of 24 ms. Display characteristics, added noise, and different analysts thus affect manual repolarization interval measurements in MCG. The errors detected demonstrate the importance of a standard presentation for repolarization measurement in the MCG.

Electrocardiography↗

Paroxysmal cycle length shortening in the pulmonary veins during atrial fibrillation correlates with arrhythmogenic triggering foci in sinus rhythm.

INTRODUCTION: The focal origin of atrial fibrillation (AF) is identified by recording atrial ectopic beats or the ectopic activity that precedes AF. We hypothesized that arrhythmogenic pulmonary veins (PVs) also could be identified during persistent AF. METHODS AND RESULTS: Patients with persistent AF referred for focal ablation were enrolled prospectively. During AF, bipolar electrograms were recorded from each PV for a minimum of 120 seconds, as well as from the right atrium and coronary sinus. The cycle length of activity in each PV was measured during AF and plotted on a frequency histogram. Following cardioversion to sinus rhythm, arrhythmogenic PVs were identified from reinitiation of AF or from ectopic beats. Ten patients were enrolled and 37 PVs analyzed. During AF, 17 PVs demonstrated bimodal cycle length frequency histograms, with periods of paroxysmal short cycle length recording. Following cardioversion, 14 PVs were identified as arrhythmogenic as defined earlier. Each of these arrhythmogenic PVs showed paroxysmal short cycle length recording during AF. Sensitivity was 87%, specificity 91%, positive predictive value 87%, and negative predictive value 100%. CONCLUSION: The arrhythmogenic PVs responsible for the focal activity that triggers AF also demonstrate paroxysmal short cycle length recording during sustained AF. These results demonstrate that arrhythmogenic PVs still can be identified reliably, even during sustained AF.

Atrial Fibrillation↗

Interatrial transseptal electrical conduction: comparison of patients with atrial fibrillation and normal controls.

INTRODUCTION: This study analyzed the electrophysiologic properties of interatrial transseptal electrical conduction at Bachmann's bundle and the ostium of the coronary sinus (CS os) in response to pulmonary vein (PV) stimuli, which mimicked spontaneous ectopy. METHODS AND RESULTS: Forty patients with atrial fibrillation (AF) referred for ablation (15 persistent AF and 25 paroxysmal AF) and 15 control patients were enrolled in the study. During decremental extra-stimulus pacing from the PVs, right atrial activation was analyzed using noncontact mapping and multipolar catheters. The refractory periods and conduction times were calculated for Bachmann's bundle, CS os, and left atrium. The dispersion of refractoriness was calculated as the difference between the refractory periods of Bachmann's bundle and the CS os. The refractory period at Bachmann's bundle was 244 msec in the persistent AF group, 213 msec in the paroxysmal AF group, and 199 msec for controls. The refractory period at the CS os was 220 msec in the persistent AF group, 201 msec in the paroxysmal AF group, and 193 msec for controls. The dispersion of refractoriness was 54 msec in the persistent AF group; this was significantly greater than in paroxysmal AF at 32 msec (P < 0.05) and controls at 13 msec (P < 0.01). During decremental pacing, lengthening of conduction times at both Bachmann's bundle and the CS os were significantly greater in the persistent AF group compared with paroxysmal AF or control groups. A higher dispersion of refractoriness was associated with a higher incidence of inducible AF and a lower rate of ablation success. CONCLUSION: There are differences between the left to right interatrial electrical connections between patients with persistent AF, paroxysmal AF and controls.

Adult↗

Evolution of ventricular function during permanent pacing from either right ventricular apex or outflow tract following AV-junctional ablation for atrial fibrillation.

AIMS: To compare acute and chronic ventricular function between patients, without cardiac failure, paced at either right ventricular apex or outflow tract. METHODS: Twenty patients. 10 paced apically and 10 in the outflow tract, underwent two radionuclide ventriculograms. Eight parameters of systolic or diastolic function were compared at each assessment, as were changes within each group over time. RESULTS: No differences were identified in systolic function between pacing sites 6 weeks after pacing or 23 weeks later. Peak filling rate was lower (P=0.04) at the second assessment with outflow tract pacing. No other diastolic differences were identified. Between assessments, time to peak filling rate prolonged (P=0.04) with apical pacing, while left ventricular area reduced (P=0.04) and peak filling rate decreased (P=0.04) with outflow tract pacing. Septal motion was better preserved with outflow tract pacing. No other parameter changed over time. ECG measures were similar at 14.7 months. CONCLUSIONS: No major differences were identified in systolic function between pacing sites. Some systolic parameters were better preserved with outflow tract pacing and diastolic function deteriorated subtly over time in both groups. Right ventricular pacing adversely affects left ventricular function.

Aged↗