Development and Monte Carlo analysis of antiscatter grids for mammography.

Mammography arguably demands the highest fidelity of all x-ray imaging applications, with simultaneous requirements of exceedingly high spatial and contrast resolution. Continuing technical improvements of screen-film and digital mammography systems have led to substantial improvements in image quality, and therefore improvements in the performance of anti-scatter grids are required to keep pace with the improvements in other components of the imaging chain. The development of an air-core honeycomb (cellular) grid using x-ray lithography and electroforming techniques is described, and the production of a 60 mm x 60 mm section of grid is reported. A crossed grid was constructed with 25 microm copper septa, and a period of 550 microm. Monte Carlo and numerical simulation methods were used to analyze the theoretical performance of the fabricated grid, and comparisons with other grid systems (Lorad HTC and carbon fiber interspaced grids) were made over a range of grid ratios. The results demonstrate essentially equivalent performance in terms of contrast improvement factor (CIF) and Bucky factor (BF) between Cu and Au honeycomb grids and the Lorad HTC (itself a copper honeycomb grid). Gold septa improved both CIF and BF performance in higher kVp, higher scatter geometries. The selectivity of honeycomb grids was far better than for linear grids, with a factor of approximately 3.9 improvement at a grid ratio of 5.0. It is concluded that using the fabrication methods described, that practical honeycomb grid structures could be produced for use in mammographic imaging, and that a substantial improvement in scatter rejection would be achieved using these devices.

Computers↗

Determining sensitivity of mammography from screening data, cancer incidence, and receiver-operating characteristic curve parameters.

OBJECTIVES: A mathematical model is presented that allows the computation of the sensitivity and specificity of breast screening based on receiver-operating characteristic (ROC) curve shape, the positive predictive value (PPV) of screening mammography, and the cancer incidence, f. METHODS: The normal and cancer populations are modeled as normal distributions with independent means and standard deviations. The distributions are scaled such that the area of the normal population is equal to 1-f and that of the cancer population is f. The PPV for screening mammography is used to determine the operating point on the ROC curve. Knowing this leads directly to the computation of sensitivity and specificity. The derivation is general and is applicable to both symmetrical and asymmetrical ROC curves. RESULTS: For symmetric ROC curves and typical values for the PPV of mammography (about 8%) and cancer incidence (f= 0.003), an A(z) value of 0.95 was required to achieve 63% sensitivity and an A. value of 0.98 led to 86% sensitivity. CONCLUSION: A model was developed that should allow researchers to deduce sensitivity and specificity for screening mammography based on ROC curve measurements and using realistic values of PPV and f. This model allows A. values to be related to the probability of breast cancer detection.

Breast Neoplasms↗