Search PubMed⌕ Search

Biomedical subjects

John Hayes

Publications and source records attributed to John Hayes.

25 records · Page 2Linked to original sources

Assessing bronchodilator responsiveness in infants using partial expiratory flow-volume curves.

Our objective was to compare the effectiveness of maximum forced expiratory flow measured at functional residual capacity (V'maxFRC) and the ratio of flow at 75% of the forced expiratory volume to peak forced expiratory flow (FEF(75)/FEF(peak)) for detecting bronchodilator-related changes in wheezy infants. In 55 infants (mean age, 7.8 +/- 3.1 months) with a history of recurrent wheezing, V'maxFRC and FEF(75)/FEF(peak) were measured at baseline and 15 min following nebulized albuterol. Mean results from 4 baseline and 4 postalbuterol partial expiratory flow-volume curves were compared at baseline and following bronchodilator challenge. The strength (relative effect size) of each measure for assessing change was quantified by dividing the mean of the pre- to postdifferences by the standard deviation of the differences. Mean percent predicted V'maxFRC was 41.3 +/- 34.3% at baseline and 44.4 +/- 34.0% following albuterol. Mean FEF(75)/FEF(peak) was 26.7 +/- 13.4% at baseline and 35.8 +/- 14.3% following albuterol. The mean percent change from baseline [(post-pre)/pre] in percent predicted V'maxFRC was 18.3 +/- 39.3, and for FEF(75)/FEF(peak), it was 44.1 +/- 36.8. The change in FEF(75)/FEF(peak) following albuterol was significantly greater than the change in V'maxFRC (P < 0.0001). The relative effect size for mean percent change from baseline in V'maxFRC was 0.47, and for FEF(75)/FEF(peak), 1.20. Changes in FEF(75)/FEF(peak) appear to differentiate changes in airway function following administration of a bronchodilator better than do changes in V'maxFRC.

Asthma↗

A population-based study of mortality among patients with atrial fibrillation or flutter.

PURPOSE: To determine the mortality associated with atrial flutter and atrial fibrillation in the general population. SUBJECTS AND METHODS: Using the Marshfield Epidemiologic Study Area, a database that captures nearly all medical care and deaths among its 58,820 residents, we identified patients diagnosed with atrial flutter or atrial fibrillation from July 1, 1991, through June 30, 1995. Patients were followed prospectively and compared with a group of controls without these arrhythmias. RESULTS: A total of 4775 person-years of follow-up were completed in 577 patients and 577 controls. Compared with controls, mortality among patients with atrial fibrillation or flutter was nearly 7.8-fold higher at 6 months (95% confidence interval [CI]: 4.1 to 15) and 2.5-fold higher (95% CI: 2.0 to 3.1; P < 0.0001) at the last follow-up (mean [+/- SD] of 3.6 +/- 2.3 years; range, 1 day to 7.3 years). At 6 months, mortality among patients with atrial flutter alone was somewhat greater than in controls and less than one third that of those with atrial fibrillation (with or without atrial flutter) (P = 0.02). At the last follow-up, however, mortality was greater among patients with atrial flutter (hazard ratio [HR] = 1.7; 95% CI: 1.2 to 2.6; P = 0.007), atrial fibrillation (HR = 2.4; 95% CI: 1.9 to 3.1; P < 0.0001), or both atrial arrhythmias (HR = 2.5; 95% CI: 1.9 to 3.3; P < 0.0001) when compared with controls in models that adjusted for cardiovascular risk factors. CONCLUSION: In the general population, both atrial flutter and atrial fibrillation are independent predictors of increased late mortality. The relatively benign course during the 6-month period after the initial diagnosis of atrial flutter suggests that early diagnosis and treatment of these patients may improve their long-term survival.

Aged↗

Long-term structural failure of coaxial polyurethane implantable cardioverter defibrillator leads.

Transvene models 6936/6966, a coaxial polyurethane ICD lead, may be prone to structural failure. These models comprise 54% of ICD lead failures in the authors' Multicenter Registry database. Because ICD leads perform a vital function, the clinical features, causes, and probability of Transvene 6936/6966 lead failure were determined. The Registry and United States Food and Drug Administration databases were queried for the clinical features and structural causes of the Transvene 6936/6966 lead failure, and a five-center substudy estimated the survival probability for 521 Transvene 6936/6966 implants. The mean time to failure was 4.8 +/- 2.1 years, and the estimated survival at 60 and 84 months after implant were 92% and 84%, respectively. Oversensing was the most common sign of failure (76%), and 24 patients experienced inappropriate shocks. The manufacturer's reports indicated that high voltage coil fracture and 80A polyurethane defects were the predominant causes of lead failure. Transvene models 6936 and 6966 coaxial polyurethane ICD leads are prone to failure over time. Patients who have these leads should be evaluated frequently. Additional studies are needed to identify safe management strategies.

Death, Sudden, Cardiac↗

Turbidity as a measure of salivary protein reactions with astringent substances.

Binding of tannins to proline-rich proteins has been proposed as an initial step in the development of astringent sensations. In beer and fruit juices, formation of tannin-protein complexes leads to the well-known effect of haze development or turbidity. Two experiments examined the development of turbidity in human saliva when mixed with tannins as a potential in vitro correlate of astringent sensations. In the first study, haze was measured in filtered human saliva mixed with a range of tannic acid concentrations known to produce supra-threshold psychophysical responses. The second study examined relationships among individual differences in haze development and the magnitude of astringency ratings. Mostly negative correlations were found, consistent with the notion that high levels of salivary proteins protect oral tissues from the drying effects of tannic acid.

Adolescent↗