An update on the assessment of osteoporosis using radiologic techniques.

In this article, the currently available radiologic techniques for assessing osteoporosis are reviewed. Density measurements of the skeleton using dual X-ray absorptiometry (DXA) are clinically indicated for the assessment of osteoporosis and for the evaluation of therapies. DXA is the most widely used technique for identifying patients with osteoporosis. Quantitative computed tomography (QCT) is the only method, which provides a volumetric density. Unlike DXA, QCT allows for selective trabecular measurement and is less sensitive to degenerative diseases of the spine. The analysis of bone structure in conjunction with bone density is an exciting new field in the assessment of osteoporosis. High-resolution multi-slice CT and micro-CT are useful tools for the assessment of bone microarchitecture. A growing literature indicates that quantitative ultrasound (QUS) techniques are capable of assessing fracture risk. Although the ease of use and the absence of ionizing radiation make QUS attractive, the specific role of QUS techniques in clinical practice needs further determination. Considerable progress has been made in the development of MR techniques for assessing osteoporosis during the last few years. In addition to relaxometry techniques, high-resolution MR imaging, diffusion MR imaging and in-vivo MR spectroscopy may be used to quantify trabecular bone architecture and mineral composition.

Bone Density↗

Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction?

This study was conducted to estimate thyroid dose and the associated risk for thyroid cancer induction from common head and neck computed tomography (CT) examinations during childhood. The Monte Carlo N-particle transport code was employed to simulate the routine CT scanning of the brain, paranasal sinuses, inner ear and neck performed on sequential and/or spiral modes. The mean thyroid dose was calculated using mathematical phantoms representing a newborn infant and children of 1year, 5 years, 10 years and 15 years old. To verify Monte Carlo results, dose measurements were carried out on physical anthropomorphic phantoms using thermoluminescent dosemeters (TLDs). The scattered dose to thyroid from head CT examinations varied from 0.6 mGy to 8.7 mGy depending upon the scanned region, the pediatric patient's age and the acquisition mode used. Primary irradiation of the thyroid gland during CT of the neck resulted in an absorbed dose range of 15.2-52.0 mGy. The mean difference between Monte Carlo calculations and TLD measurements was 11.8%. Thyroid exposure to scattered radiation from head CT scanning is associated with a low but not negligible risk of cancer induction of 4-65 per million patients. Neck CT can result in an increased risk for development of thyroid malignancies up to 390 per million patients.

Adolescent↗

Dosimetric characteristics of a 16-slice computed tomography scanner.

Standard CT dose measurements were performed on a Siemens Sensation 16 scanner. CT dose indices, free-in-air (CTDI(F)) and weighted (CTDI(W)), were measured in all available axial and helical beam collimations of the head and body scanning modes. The effect of tube current, high voltage, rotation time, beam collimation and pitch on the CT doses was investigated. CT doses increased as a power function of high voltage. The kVp exponent n varied with beam collimation from 2.7 to 3.1 for CTDI(W), and from 2.4 to 2.6 for CTDI(F). Automatic change of the focal spot size increased radiation doses up to a factor of 1.18. Measured small-focus CTDI(W) values differed from those displayed at the console from -24 to 14%. Peripheral doses in the head phantom were higher compared to the body phantom by a factor of 1.5 to 2. Central doses are 2.7 to 4.1 times higher. Differences in beam collimation resulted in 50% variation in the CTDI(W) in the body phantom and 60% in the head phantom. In conclusion, our study has confirmed the great impact of technique factors and acquisition parameters on CT doses. The provided comprehensive dosimetric data will facilitate the dose-effective use of the scanner studied.

Computer Simulation↗

Scattered dose to thyroid from prophylactic cranial irradiation during childhood: a Monte Carlo study.

The purpose of this study was to estimate the scattered dose to thyroid from prophylactic cranial irradiation during childhood. The MCNP transport code and mathematical phantoms representing the average individual at ages 3, 5, 10, 15 and 18 years old were employed to simulate cranial radiotherapy using two lateral opposed fields. The mean radiation dose received by the thyroid gland was calculated. A 10 cm thick lead block placed on the patient's couch to shield the thyroid was simulated by MCNP code. The Monte Carlo model was validated by measuring the scattered dose to the unshielded and shielded thyroid using three different humanoid phantoms and thermoluminescense dosimetry. For a cranial dose of 18 Gy, the thyroid dose obtained by Monte Carlo calculations varied from 47 to 79 cGy depending upon the age of the child. Appropriate placement of the couch block resulted in a thyroid dose reduction by 39 to 54%. Thyroid dose values at all possible positions of the radiosensitive gland with respect to the inferior field edge at five different patient ages were found. The mean difference between Monte Carlo results and thyroid dose measurements was 9.6%.

Body Burden↗

Fluoroscopically assisted surgical treatments of spinal disorders: conceptus radiation doses and risks.

STUDY DESIGN: A series of anterior-posterior and lateral fluoroscopic exposures at 5 spinal levels were performed on anthropomorphic phantoms simulating the 3 trimesters of gestation. OBJECTIVES: To provide normalized data for the determination of conceptus dose specific to gestational stage and treated spinal level. To estimate the conceptus radiation dose and risk associated with typical fluoroscopically guided spinal treatments performed on the pregnant patient. SUMMARY OF BACKGROUND DATA: To our knowledge, there are no available data on conceptus doses and radiogenic risks resulting from fluoroscopically guided spinal surgery of the expectant mother. METHODS: Direct measurement of conceptus doses from simulated fluoroscopic projections involved in orthopedic surgery at different spinal levels for the 3 trimesters of gestation with use of anthropomorphic phantoms and thermoluminescent dosimetry. Estimation of conceptus radiation risks from a typical pedicle screw fixation and kyphoplasty procedure using the experimentally derived data. RESULTS: Conceptus doses from fluoroscopically guided spinal treatments are smaller than 4 mGy during all gestational stages, provided that the conceptus lies outside the primarily irradiated region. The associated risks of fatal cancer during childhood and congenital malformation on its progeny are at least 2 and 1500 times, respectively, lower than the spontaneous incidence rates. When the embryo is primarily irradiated, mean conceptus dose can be as high as 105 mGy from a nonoptimized exposure. At least 35 minutes of fluoroscopy are required for the induction of deterministic effects. CONCLUSIONS: Individual dose assessment is paramount in every pregnancy. Variations in fluoroscopy practices and gestational stage significantly affect fetal doses.

Computer Simulation↗

Radiation dose to laterally transposed ovaries during external beam radiotherapy for cervical cancer.

The purpose of this study was to estimate the radiation dose to laterally transposed ovaries from external beam radiotherapy for cervical cancer. Dose measurements were performed in a modified humanoid phantom using a 6 MV photon beam. The dependence of the ovarian dose upon the field size, the distance from the primary irradiation field and the presence of wedges or gonadal shielding was determined. For a tumor dose of 45 Gy, ovarian dose was 0.88-8.51 Gy depending on the field size employed and the location of the transposed ovary in respect to the treatment field. Positioning of 7 cm thick shielding reduced the dose to ovary by less than 19%. The use of wedges increased the ovarian dose by a factor up to 1.5. Accurate radiographic localization of the ovaries allows the use of the presented dosimetric results to obtain a reasonable prediction of the ovarian dose.

Female↗

Radiation dose and risk from fluoroscopically guided percutaneous transhepatic biliary procedures.

PURPOSE: To estimate radiation dose and associated risks after fluoroscopically guided percutaneous transhepatic biliary (PTB) drainage and stent implantation procedures. MATERIALS AND METHODS: Organ and effective doses, normalized to dose-area product (DAP), were estimated for PTB procedures with use of a Monte Carlo transport code and an adult mathematical phantom. Exposure parameters from 51 consecutive patients were used to determine average examination parameters for biliary drainage and stent implantation procedures. Thermoluminescent dosimeters were used in an anthropomorphic phantom to verify Monte Carlo calculations. Radiation-induced cancer and genetic risks were estimated. RESULTS: The results consist of doses normalized to DAP so patient dose from any technique and x-ray unit can be easily calculated for left and right biliary access and for separate or combined biliary and metallic stent implantation sessions. A good agreement was found between Monte Carlo-calculated data and data derived from thermoluminescent dosimetry. The average effective dose varied from 1.8 to 5.4 mSv depending on procedure approach (left vs right access) and procedure scheme. A maximum effective dose of 13 mSv was estimated for 30 minutes of fluoroscopy. CONCLUSIONS: Doses delivered to patients undergoing PTB procedures are comparable to those that arise from computed tomography protocols. Radiation-induced cancer risk may be considerable for young patients undergoing PTB drainage and stent implantation procedures.

Adult↗

Occupational radiation exposure from fluoroscopically guided percutaneous transhepatic biliary procedures.

PURPOSE: The aim of this study was to determine occupational dose levels for projections commonly used in fluoroscopically guided percutaneous transhepatic biliary (PTB) drainage and stent placement procedures. METHODS: Exposure data from 71 consecutive PTB examinations were analyzed to determine average examination parameters for biliary drainage and stent placement procedures. An anthropomorphic phantom was exposed at three projections common in PTB interventions according to the actual geometric parameters recorded in the patient study. Scattered air-kerma dose rates were measured for neck, waist, and gonad levels at various sites in the interventional radiology laboratory. To produce technique- and instrumentation-independent data, dose rate values were converted to dose-area product (DAP)-normalized air-kerma values. In addition, sets of thermoluminescent dosimetry crystals were placed in both hands of the interventional radiologist to monitor doses during all PTB procedures. RESULTS: Isodose maps of DAP-normalized air-kerma doses in the interventional laboratory for projections commonly used in PTB procedures are presented. To facilitate effective dose estimation, normalized dosimetric data at the interventional radiologist's position are presented for left and right access drainage procedures, metallic stent placement only, and drainage and metallic stent placement in one-session procedures with and without under-couch shielding. Doses to the hands of interventional radiologists are presented for left and right transhepatic biliary access and metallic stent placement. CONCLUSIONS: Body level-specific normalized air-kerma distributions from commonly used projections in PTB procedures may be useful to accurately quantify dose, maximum workloads, and possible radiogenic risks delivered to medical personnel working in the interventional radiology laboratory. Normalized dose data presented will enable occupational exposure estimation from other institutions.

Aged↗

Normalized dose data for upper gastrointestinal tract contrast studies performed to infants.

The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institution. Organ and effective doses, normalized to entrance skin dose (ESD) and dose area product (DAP) were estimated for UGIC procedures utilizing the Monte Carlo N-particle (MCNP) transport code and two mathematical phantoms, one corresponding to the size of a newborn and one to the size of a 1-year-old child. The validity of the MCNP results was verified by comparison with dose data obtained in physical anthropomorphic phantoms simulating a newborn and a 1-year-old infant using thermoluminescence dosimetry (TLD). Data were also collected from 25 consecutive UGIC examinations performed to infants. Study participants were (a) 12 infants aged from 0.5 to 5.9 months (group 1) and (b) 13 infants aged from 6 to 15 months (group 2). For each examination, ESD and dose to comforters were measured using TLD. Patient effective doses were estimated using normalized dose data obtained in the simulation study. The risk for fatal cancer induction was estimated using appropriate coefficients. The results consist of tabulated dose data normalized to ESD or DAP for the estimation of patient dose. Conversion coefficients were estimated for various tube potentials and beam filtration values. The mean total fluoroscopy time was 1.26 and 1.62 min for groups 1 and 2, respectively. The average effective dose was 1.6 mSv for group 1 and 1.9 mSv for group 2. The risk of cancer attributable to the radiation exposure associated with a typical UGIC study was found to be up to 3 per 10 000 infants undergoing an UGIC examination. The mean radiation dose absorbed by the hands of comforters was 47 microGy. In conclusion, estimation of radiation doses associated with UGIC studies performed to infants can be made using the normalized dose data provided in the current study. Radiation dose values associated with UGIC examinations carried out to infants are not low and should be minimized as much as possible.

Body Burden↗

The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study.

The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volume boundaries. This information was used to simulate CT exposures by Monte Carlo code. The Monte Carlo N-Particle (MCNP, version 4C2) radiation transport code and five mathematical anthropomorphic phantoms representing newborn, 1-, 5-, 10-, and 15-year-old patient, were employed in the current study. To estimate effective dose, the weighted computed tomography dose index was calculated by cylindrical polymethyl-methacrylate phantoms of 9.7, 13.1, 15.4, 16.1, and 16.9 cm in diameter representing the pediatric head of newborn, 1-, 5-, 10-, and 15-year-old individuals, respectively. The validity of the Monte Carlo calculated approach was verified by comparison with dose data obtained using physical pediatric anthropomorphic phantoms and thermoluminescence dosimetry. For all patients studied, the eye lenses were located in the region -1 to 3 cm from the first slice of the imaged volume. Doses from axial scans were always lower than those from corresponding helical examinations. The percentage differences in normalized eye lens absorbed dose between contiguous axial and helical examinations with pitch=1 were found to be up to 10.9%, when the eye lenses were located inside the region to be imaged. When the eye lenses were positioned 0-3 cm far from the first slice of region to be imaged, the normalized dose to the lens from contiguous axial examinations was up to 11 times lower than the corresponding values from helical mode with pitch=1. The effective dose from axial examinations was up to 24% lower than corresponding values from helical examinations with pitch=1. In conclusion, it is more dose efficient to use axial mode acquisition rather than helical scan for pediatric head examinations, if there are no overriding clinical considerations.

Adolescent↗

Data required for testicular dose calculation during radiotherapy of seminoma.

The purpose of this study was to provide the required data for the direct calculation of testicular dose resulting from radiotherapy in patients with seminoma. Paraortic (PA) treatment fields and dog-leg (DL) portals including paraortic and ipsilateral pelvic nodes were simulated on a male anthropomorphic phantom equipped with an artificial testicle. Anterior and posterior irradiations were performed for five different PA and DL field dimensions. Dose measurements were carried out using a calibrated ionization chamber. The dependence of testicular dose upon the distance separating the testicle from the treatment volume and upon the tissue thickness at the entrance point of the beam was investigated. A clamshell lead shield was used to reduce testicular dose. The scattered dose to testicle was measured in nine patients using thermoluminescent dosimeters. Phantom and patient exposures were generated with a 6 MV x-ray beam. Linear and nonlinear regression analysis was employed to obtain formulas describing the relation between the radiation dose to an unshielded and/or shielded testicle with the field size and the distance from the inferior field edge. Correction factors showing the variation of testicular dose with the patient thickness along beam axis were found. Bland-Altman statistical analysis showed that testicular dose obtained by the proposed calculation method may differ from the measured dose value by less than 25%. The current study presents a method providing reasonable estimations of testicular dose for individual patients undergoing PA or DL radiotherapy.

Calibration↗

Estimation of effective doses to adult and pediatric patients from multislice computed tomography: A method based on energy imparted.

The purpose of this study is to provide a method and required data for the estimation of effective dose (E) values to adult and pediatric patients from computed tomography (CT) scans of the head, chest abdomen, and pelvis, performed on multi-slice scanners. Mean section radiation dose (dm) to cylindrical water phantoms of varying radius normalized over CT dose index free-in-air (CTDIF) were calculated for the head and body scanning modes of a multislice scanner with use of Monte Carlo techniques. Patients were modeled as equivalent water phantoms and the energy imparted (epsilon) to simulated pediatric and adult patients was calculated on the basis of measured CTDI(F) values. Body region specific energy imparted to effective dose conversion coefficients (E/epsilon) for adult male and female patients were generated from previous data. Effective doses to patients aged newborn to adult were derived for all available helical and axial beam collimations, taking into account age specific patient mass and scanning length. Depending on high voltage, body region, and patient sex, E/epsilon values ranged from 0.008 mSv/mJ for head scans to 0.024 mSv/mJ for chest scans. When scanned with the same technique factors as the adults, pediatric patients absorb as little as 5% of the energy imparted to adults, but corresponding effective dose values are up to a factor of 1.6 higher. On average, pediatric patients absorb 44% less energy per examination but have a 24% higher effective dose, compared with adults. In clinical practice, effective dose values to pediatric patients are 2.5 to 10 times lower than in adults due to the adaptation of tube current. A method is provided for the calculation of effective dose to adult and pediatric patients on the basis of individual patient characteristics such as sex, mass, dimensions, and density of imaged anatomy, and the technical features of modern multislice scanners. It allows the optimum selection of scanning parameters regarding patient doses at CT.

Adult↗

Radiation dose to testes and risk of infertility from radiotherapy for rectal cancer.

This study aims to provide the means for testicular dose estimation from radiotherapy for rectal cancer. Rectal irradiation was simulated on a humanoid phantom using a 6 MV photon beam. The effect of field size, distance from irradiated area, wedge introduction into lateral beams, tissue thickness along the beam axis and use of gonad shields on the testicular dose was examined. Testicular dose was measured in five patients undergoing radiotherapy for rectal carcinoma. For a 4500 cGy tumour dose, testicular dose was 32-216 cGy depending upon the field dimensions and the distance from the field isocenter. The presence of wedges increased the testicular dose by a factor up to 2.2. The increase of irradiated tissue thickness increased the gonadal dose up to 40% whereas the use of the appropriate gonad shield reduced the dose by >66%. A simple method was developed to estimate testicular dose. The mean difference between the in vivo gonadal doses and the doses calculated using the proposed method was 5.8%. Testicular dose can exceed the value of 100 cGy, which permits a complete recovery of spermatogenesis. The presented data can be used to estimate the gonadal dose and the associated risk of infertility attributable to rectal irradiation.

Humans↗

Fluoroscopically guided implantation of modern cardiac resynchronization devices: radiation burden to the patient and associated risks.

OBJECTIVES: To establish radiation risks for patients undergoing fluoroscopically guided cardiac resynchronization device implantation. BACKGROUND: Cardiac resynchonization therapy (CRT) may be associated with extended fluoroscopic exposure. METHODS: The fluoroscopy time, dose-area product (DAP), exposure parameters, and percentage contribution of the fluoroscopic projections commonly used were recorded in a series of 14 consecutive patients referred for cardiac resynchronization device implantation and compared to corresponding data obtained from a control group of 20 patients who underwent a conventional rhythm device implantation operation. The DAP to peak skin dose, DAP to effective dose, and DAP to gonadal dose conversion factors were determined for biventricular pacing and conventional rhythm device implantation using a humanoid phantom and thermoluminescence dosimetry. RESULTS: The mean total fluoroscopy time and DAP values were 35.2 min and 4,765 cGy cm2, respectively, for biventricular pacing and 8.2 min and 1,106 cGy cm2, respectively, for conventional rhythm device implantation. Patient skin dose from biventricular pacing procedures requiring extended fluoroscopic exposure may exceed threshold dose for the induction of skin effects only if X-ray source-to-skin distance is kept low. The risk values for fatal cancer and severe hereditary disorders, respectively, associated with a typical CRT procedure were 273 per million and 0.2 per million treated patients. CONCLUSIONS: Radiation risks associated with fluoroscopically guided CRT procedures may be considerable. Present data may be used for the estimation of patient radiation risks from CRT procedures performed in other institutions.

Aged↗

Fluoroscopy-controlled voiding cystourethrography in infants and children: are the radiation risks trivial?

The purpose of this study was to determine the gonadal dose, effective dose and relevant radiogenic risks associated with pediatric patients undergoing voiding cystourethrography (VCUG). Exposure parameters were monitored in 118 consecutive children undergoing VCUG. The entrance surface dose (ESD) was determined by thermoluminescent dosimeters (TLDs). For male patients, the gonadal dose was determined by TLDs attached on the anterior scrotum. For female patients, the gonadal dose was estimated by converting ESD to the ovarian dose. ESD-to-ovarian dose conversion factors were determined by thermoluminescence dosimetry and physical anthropomorphic phantoms representing newborn and 1-, 5- and 10-year-old individuals. The effective dose was estimated by using ESD and data obtained from the literature. The mean fluoroscopy time and number of radiographs during VCUG were 0.73 min and 2.3 for female and 0.91 min and 3.0 for male pediatric patients, respectively. The gonadal dose range was 0.34-5.17 mGy in boys and 0.36-2.57 mGy in girls. The corresponding ranges of effective dosage were 0.12-1.67 mSv and 0.15-1.45 mSv. Mean radiation risks for genetic anomalies and carcinogenesis following VCUG during childhood were estimated to be up to 15 per million and 125 per million, respectively. Radiation risks associated with pediatric patients undergoing VCUG should not be disregarded if such a procedure is to be justified adequately.

Adolescent↗

Does raloxifene treatment influence back pain and disability among postmenopausal women with osteoporosis?

Clinical studies have suggested that postmenopausal women on estrogen replacement treatment are more likely to experience back pain and related disability compared to women who do not take estrogens. Raloxifene, a selective estrogen receptor modulator has estrogen-like effects on bone tissue, and antagonize the action of estrogens on endometrium and breast tissue. It is unknown if the treatment of osteoporosis with raloxifene has estrogen-like or opposite effects on back pain and functional capacity among postmenopausal women with osteoporosis. A total of 120 postmenopausal women with osteoporosis and chronic back pain were randomized to receive raloxifene 60 mg with 1,000 mg calcium, and 800 IU vitamin D daily or 1,000 mg calcium and 800 IU vitamin D daily. Pain intensity and pain-related disability were measured before treatment at 6 months and after 1 year. Repeated measures of ANOVA, did not reveal statistically significant differences over time, on pain intensity and disability scores, between groups studied. There was a trend in pain intensity changes during the follow-up period, but the differences between the groups were not statistically significant. It seems that treatment with raloxifene does not influence back pain and disability among postmenopausal women with osteoporosis. Raloxifene may have estrogenic agonist effects on nociceptive processing in the central nervous system.

Back Pain↗

Relation between bone marrow angiogenesis and serum levels of angiogenin in patients with myelodysplastic syndromes.

Angiogenesis is implicated in the progression of myelodysplastic syndromes (MDS). Bone marrow microvascular density (MVD), serum angiogenin (ANG) and interleukin 6 (IL-6) were measured in 67 patients with untreated MDS. MVD, ANG and IL-6 were significantly higher in the patient group as a whole when compared to controls (P < 0.01). MVD and ANG were significantly higher in subtypes with a high-risk for leukemic transformation (RAEB, RAEB-t and CMML) than in low-risk subtypes (RA and RARS) (P < 0.01). In the MDS group, a positive correlation was found between ANG and IL-6 (P < 0.001) and also between MVD and IL-6 (P < 0.05). Using multivariate analysis, only IL-6 displayed independent prognostic value and was inversely related to MDS survival.

Aged↗

Image-guided reconstruction of femoral fractures: is the staff progeny safe?

The potential of adverse effects to progeny caused by preconceptual and fetal exposure to ionizing radiation is an issue of increasing concern to orthopaedic surgeons and assisting staff. Are these fears justified? How effectively is the embryo or fetus protected, and should pregnant staff alter their duties? In this study, an anthropomorphic phantom was exposed fluoroscopically at two geometries common in surgical reconstruction of proximal femur fractures. Scatter radiation was converted to gonadal dose and embryo or fetal dose with and without use of a protective apron. The genetic risk for the orthopaedic surgeon after 10 years of occupational exposure was estimated to be 16,000 times lower than the natural frequency of heritable disease. The excess risk of childhood cancer associated with the dose accumulated during gestation was at least 600 times lower than the corresponding natural frequency. A properly shielded pregnant orthopaedic surgeon is allowed to do 14 hours of hip fluoroscopy during gestation, whereas 2100 hours of fluoroscopy are required for the induction of gross malformation or mental retardation to the growing embryo or fetus. The supplementary dose constraints for pregnant staff provide adequate protection to the unborn child without affecting regular personnel duties.

Dose-Response Relationship, Radiation↗