Improved wrist pannus volume measurement from contrast-enhanced MRI in rheumatoid arthritis using shuffle transform.

BACKGROUND: Contrast-enhanced MRI is of value in assessing rheumatoid pannus in the hand, but the images are not always easy to quantitate. OBJECTIVE: To develop and evaluate an improved measurement of volume of enhancing pannus (VEP) in the hand in human rheumatoid arthritis (RA). METHODS: MR images of the hand and wrist were obtained for 14 patients with RA at 0, 1 and 13 weeks. Volume of enhancing pannus was measured on images created by subtracting precontrast T1-weighted images from contrast-enhanced T1-weighted images using a shuffle transformation technique. Maximum intensity projection (MIP) and 3D volume rendering of the images were used as a guide to identify the pannus and any contrast-enhanced veins. RESULT: Visualisation of pannus was much improved following the shuffle transform. Between 0 weeks and 1 week, the mean value of the within-subject coefficient of variation (CoV) was 0.13 and the estimated total CoV was 0.15. There was no evidence of significant increased variability within the 13-week interval for the complete sample of patients. CONCLUSION: Volume of enhancing pannus can be measured reproducibly in the rheumatoid hand using 3D contrast-enhanced MRI and shuffle transform.

Adult↗

Comparative study into the robustness of compartmental modeling and model-free analysis in DCE-MRI studies.

PURPOSE: To evaluate and compare the reproducibility of the preferred phenomenological parameter IAUC60 (initial area under the time-concentration curve [IAUC] defined over the first 60 seconds postenhancement) with the preferred modeling parameter (K(trans)), as derived using two simple models, in abdominal and cerebral data collected in typical Phase I clinical trial conditions. MATERIALS AND METHODS: Dynamic contrast enhanced MRI (DCE-MRI) time series were acquired at two imaging centers from a group of patients with abdominal tumors and a group with gliomas. At both imaging centers, precontrast T1 was calculated using a variable flip angle three-dimensional spoiled gradient echo acquisition that was used to quantify tissue contrast agent concentration, allowing voxelwise definition of summary DCE-MRI parameters. RESULTS: A comparison of reproducibility showed that there was no statistically significant difference in reproducibility between IAUC60 and K(trans), although there was a trend towards better reproducibility for K(trans) (P = 0.0782). The 95% confidence intervals (CIs) for individual changes showed that for IAUC60 and K(trans), changes in excess of 47% and 31%, respectively, are outside the range of normal variability. CONCLUSION: Although modeling is more complex and more computationally intensive than an IAUC parameterization, our data suggest this approach to be preferable to a model-free approach since it provides greater physiological insight without a reduction in statistical power for Phase I/II clinical drug trials.

Abdominal Neoplasms↗

Abnormalities of CSF flow patterns in the cerebral aqueduct in treatment-resistant late-life depression: a potential biomarker of microvascular angiopathy.

There is growing evidence that microvascular angiopathy (MVA) plays an important role in the development of dementia and affective disorders in older people. At currently available image resolutions it is not possible to image directly the vascular changes associated with MVA, but the effects on blood and cerebrospinal fluid (CSF) flow may be detectable. The aim of this study was to investigate a potential biomarker for MVA based on MRI of abnormalities in CSF flow. Since there is considerable indirect evidence that treatment resistance in late-onset depressive disorder is related to MVA, we assessed the method in a group of 22 normal volunteers and 29 patients with responsive (N=21) or treatment-resistant (N=8) late-onset depressive disorder. Single-slice quantified phase-contrast (PC) images of cerebral blood and CSF flow were collected at 15 points over a cardiac cycle, and the resulting flow curves were parameterized. Significant differences in the CSF flow (width of systolic flow peak and diastolic flow volume, both P<0.01) through the cerebral aqueduct were observed for the group of treatment-resistant patients when compared to age matched controls. No significant difference was observed for a group of 21 patients with treatment-responsive depression. The findings support the hypothesis that MR measurement of CSF flow abnormalities provides a biomarker of MVA, and thus could have application in a wide range of age-related diseases.

Aged↗

The response of RIF-1 fibrosarcomas to the vascular-disrupting agent ZD6126 assessed by in vivo and ex vivo 1H magnetic resonance spectroscopy.

The response of radiation-induced fibrosarcoma 1 (RIF-1) tumors treated with the vascular-disrupting agent (VDA) ZD6126 was assessed by in vivo and ex vivo 1H magnetic resonance spectroscopy (MRS) methods. Tumors treated with 200 mg/kg ZD6126 showed a significant reduction in total choline (tCho) in vivo 24 hours after treatment, whereas control tumors showed a significant increase in tCho. This response was investigated further within both ex vivo unprocessed tumor tissues and tumor tissue metabolite extracts. Ex vivo high-resolution magic angle spinning (HRMAS) and 1H MRS of metabolite extracts revealed a significant reduction in phosphocholine and glycerophosphocholine in biopsies of ZD6126-treated tumors, confirming in vivo tCho response. ZD6126-induced reduction in choline compounds is consistent with a reduction in cell membrane turnover associated with necrosis and cell death following disruption of the tumor vasculature. In vivo tumor tissue water diffusion and lactate measurements showed no significant changes in response to ZD6126. Spin-spin relaxation times (T2) of water and metabolites also remained unchanged. Noninvasive 1H MRS measurement of tCho in vivo provides a potential biomarker of tumor response to VDAs in RIF-1 tumors.

Animals↗

Improved quantitative dynamic regional oxygen-enhanced pulmonary imaging using image registration.

Oxygen-enhanced MR imaging has been demonstrated in a number of recent studies as a potential method to visualize regional ventilation in the lung. A quantitative pixel-by-pixel analysis is hampered by motion and volume change due to breathing. In this study, image registration via active shape modeling is shown to produce significant improvements in the regional analysis of both static and dynamic oxygen-enhanced pulmonary MRI for five normal volunteers. The method enables the calculation of regional change in relaxation rate between breathing air and 100% oxygen, which is proportional to the change in regional oxygen concentration, and regional oxygen wash-in and wash-out time constants. Registration-corrected mapping of these parameters is likely to provide improved information in the regional assessment of a range of lung diseases.

Administration, Inhalation↗

A longitudinal study of R2* and R2 magnetic resonance imaging relaxation rate measurements in murine liver after a single administration of 3 different iron oxide-based contrast agents.

OBJECTIVE: The objective of this study was to investigate the duration of R2* and R2 enhancement in murine liver in vivo after administration of a single dose of 3 different iron oxide-based contrast agents. MATERIALS AND METHODS: Murine liver R2* and R2 were quantified longitudinally postadministration of 2.5 mgFe/kg ferumoxides, 2.5 mgFe/kg ferumoxytol, 2.5 or 5 mgFe/kg feruglose, or saline over 50 days. Changes in R2* and R2 were evaluated histologically using Perl's staining and by atomic absorption spectrometry. RESULTS: All 3 contrast agents significantly increased liver R2* and R2 4 hours after challenge. After 10 days, R2* and R2 for both the ferumoxides and ferumoxytol cohorts had recovered to saline control levels, whereas the faster R2* and R2 of the feruglose cohort was sustained and significantly faster than control at day 50. Histology revealed feruglose in both Kupffer and endothelial cells, whereas both ferumoxides and ferumoxytol were associated with the Kupffer cells. CONCLUSION: Compared with ferumoxides and ferumoxytol, feruglose exhibits prolonged R2* and R2 enhancement of murine liver.

Animals↗

Acute tumor response to ZD6126 assessed by intrinsic susceptibility magnetic resonance imaging.

The effective magnetic resonance imaging (MRI) transverse relaxation rate R(2)* was investigated as an early acute marker of the response of rat GH3 prolactinomas to the vascular-targeting agent, ZD6126. Multigradient echo (MGRE) MRI was used to quantify R(2)*, which is sensitive to tissue deoxyhemoglobin levels. Tumor R(2)* was measured prior to, and either immediately for up to 35 minutes, or 24 hours following administration of 50 mg/kg ZD6126. Following MRI, tumor perfusion was assessed by Hoechst 33342 uptake. Tumor R(2)* significantly increased to 116 +/- 4% of baseline 35 minutes after challenge, consistent with an ischemic insult induced by vascular collapse. A strong positive correlation between baseline R(2)* and the subsequent increase in R(2)* measured 35 minutes after treatment was obtained, suggesting that the baseline R(2)* is prognostic for the subsequent tumor response to ZD6126. In contrast, a significant decrease in tumor R(2)* was found 24 hours after administration of ZD6126. Both the 35-minute and 24-hour R(2)* responses to ZD6126 were associated with a decrease in Hoechst 33342 uptake. Interpretation of the R(2)* response is complex, yet changes in tumor R(2)* may provide a convenient and early MRI biomarker for detecting the antitumor activity of vascular-targeting agents.

Animals↗

Growth hormone overexpression in the central nervous system results in hyperphagia-induced obesity associated with insulin resistance and dyslipidemia.

It is well known that peripherally administered growth hormone (GH) results in decreased body fat mass. However, GH-deficient patients increase their food intake when substituted with GH, suggesting that GH also has an appetite stimulating effect. Transgenic mice with an overexpression of bovine GH in the central nervous system (CNS) were created to investigate the role of GH in CNS. This study shows that overexpression of GH in the CNS differentiates the effect of GH on body fat mass from that on appetite. The transgenic mice were not GH-deficient but were obese and showed increased food intake as well as increased hypothalamic expression of agouti-related protein and neuropeptide Y. GH also had an acute effect on food intake following intracerebroventricular injection of C57BL/6 mice. The transgenic mice were severely hyperinsulinemic and showed a marked hyperplasia of the islets of Langerhans. In addition, the transgenic mice displayed alterations in serum lipid and lipoprotein levels and hepatic gene expression. In conclusion, GH overexpression in the CNS results in hyperphagia-induced obesity indicating a dual effect of GH with a central stimulation of appetite and a peripheral lipolytic effect.

Adipose Tissue↗

Determination of carotid artery atherosclerotic lesion type and distribution in hypercholesterolemic patients with moderate carotid stenosis using noninvasive magnetic resonance imaging.

BACKGROUND AND PURPOSE: The aims of this study were to noninvasively determine carotid atherosclerotic lesion type and distribution and to evaluate the reproducibility of determining lesion types in asymptomatic patients with moderate hypercholesterolemia and moderate carotid artery (CA) stenosis using MRI. METHODS: Forty-two asymptomatic patients with moderate CA stenosis underwent bilateral carotid MRI in a 1.5-T scanner using a protocol that generated 4 contrast weightings (T1, T2, proton density, and 3D time of flight). MRI-modified American Heart Association criteria were used to evaluate lesion types at 3 locations (common and internal CA [CCA and ICA, respectively] and CA bifurcation) and at the minimum lumen area. Two identical MR scans were conducted to evaluate reproducibility of lesion types. RESULTS: Lesion types were obtained from 230 locations. Type III (39%) occurred most commonly, followed by types IV-V (25%), I-II (20%), VI (12%), and VII (4%). Type III was more commonly distributed in the CCA (n=35, 39%) and ICA (n=32, 36%). Type IV-V was more commonly distributed in the CCA (n=24, 41%) and at the bifurcation (n=21, 36%). Forty-two lesions were available at the site of minimum lumen area: type III (33%), IV-V (33%), VI (29%), and VII (5%). There was good agreement of lesion types between both MRI scans (Cohen's kappa=0.73; 95% CI: 0.65 to 0.81). CONCLUSIONS: MRI can determine lesion types reproducibly as well as the distribution of lesions in hypercholesterolemic patients with moderate CA stenosis. A wide range of lesion types, including advanced lesions, were found in these patients.

Aged↗

Magnetic resonance imaging measurements of the response of murine and human tumors to the vascular-targeting agent ZD6126.

PURPOSE: ZD6126 is a novel vascular targeting agent currently undergoing clinical evaluation. It acts by destabilizing the microtubulin of fragile and proliferating neoendothelial cells in tumors. The drug leads to blood vessel congestion, the selective destruction of the vasculature, and extensive necrosis in experimental tumors. The aim of the study reported here was to assess the ability of dynamic contrast enhanced magnetic resonance imaging (MRI) to measure the antivascular effects of ZD6126 in tumors. EXPERIMENTAL DESIGN: The work was carried out in mice bearing C38 colon adenocarcinoma and in patients with advanced cancers. MRI was performed before and 6 h (human tumors) or 24 h (C38 tumors) after i.v. drug administration. Contrast agent (gadolinium diethylenetriaminepentaacetate) enhancement was characterized by the initial area under the gadolinium diethylenetriaminepentaacetate uptake versus time curve (IAUC). IAUC reflects blood flow, vascular permeability, and the fraction of interstitial space. RESULTS: The median IAUC was reduced in all C38 tumors after ZD6126 administration [by 6-48% at 50 mg/kg (n = 3)], 58-91% at 100 mg/kg (n = 4), and 11-93% at 200 mg/kg (n = 6). In contrast, the administration of vehicle only led to no consistent change in median IAUC (n = 4). The ZD6126-induced changes in median IAUC appeared to be dose dependent (P = 0.045). No ZD6126-induced changes were apparent in murine muscle. Similar effects were seen in preliminary data from human tumors (11 tumors studied, 9 patients). At doses of 80 mg/m(2) and higher, the median IAUC post-ZD6126 treatment was reduced in all of the tumors studied (8 tumors, 6 patients) to 36-72% from the baseline value. There was a significant trend of increasing reductions with increasing exposure (P < 0.01). No drug-induced changes in human muscle or spleen IAUC were apparent. The reproducibility of the median IAUC parameter was investigated in patients. In 19 human tumors (measured in 19 patients) inter- and intratumor coefficients of variation were 64 and 18%. CONCLUSIONS: The contrast enhanced-MRI measured median IAUC is a useful end point for quantifying ZD6126 antivascular effects in human tumors.

Angiogenesis Inhibitors↗

Effective blood signal suppression using double inversion-recovery and slice reordering for multislice fast spin-echo MRI and its application in simultaneous proton density and T2 weighted imaging.

PURPOSE: To design a multislice double inversion-recovery fast spin-echo (FSE) sequence, with k-space reordered by inversion time at slice position (KRISP) technique, to produce black-blood vessel wall magnetic resonance imaging (MRI). MATERIALS AND METHODS: In this sequence, central k-space sampling for each slice is required at inversion time (TI) of the blood signal. To fill the entire k-space, the peripheral lines are obtained less or greater the TI and using a rotating slice order. Blood flow signal suppression was first evaluated using a phantom. Simulation studies were used to investigate FSE image quality. The final sequence was then applied to the rabbit abdominal aorta MRI at 4.7 T. RESULTS: In the flow phantom study, artifacts from slow-flowing water were substantially reduced by the KRISP technique; residual water spins were dephased by the strong phase-encoding gradient required for peripheral k-space. These dephased spins flowed into the slice plane where the center of k-space was being acquired at the TI of the flowing water signal. Multislice black-blood MR images were successfully obtained in the rabbit abdomen using the sequence with the k-trajectory optimized by the simulation study. CONCLUSION: The KRISP technique was effective both in multislice double inversion-recovery FSE and in blood signal suppression.

Abdomen↗

Corresponding articular cartilage thickness measurements in the knee joint by modelling the underlying bone (commercial in confidence).

We present a method for corresponding and combining cartilage thickness readings from a population of patients using the underlying bone structure as a reference. Knee joint femoral bone and cartilage surfaces are constructed from a set of parallel slice segmentations of MR scans. Correspondence points across a population of bone surfaces are defined and refined by minimising an objective function based on the Minimum Description Length of the resulting statistical shape model. The optimised bone model defines a set of corresponding locations from which 3D measurements of the cartilage thickness can be taken and combined for a population of patients. Results are presented for a small group of patients demonstrating the feasibility and potential of the approach as a means of detecting sub-millimetre cartilage thickness changes due to disease progression.

Algorithms↗

Dynamic contrast-enhanced MRI of vascular changes induced by the VEGF-signalling inhibitor ZD4190 in human tumour xenografts.

Dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) was used to examine the acute effects of treatment with an inhibitor of vascular endothelial growth factor (VEGF) signaling. ZD4190 is an orally bioavailable inhibitor of VEGF receptor-2 (KDR) tyrosine kinase activity, which elicits broad-spectrum antitumour activity in preclinical models following chronic once-daily dosing. Nude mice, bearing established (0.5-1.0 mL volume) human prostate (PC-3), lung (Calu-6) and breast (MDA-MB-231) tumor xenografts, were dosed with ZD4190 (p.o.) using a 1 day (0 and 22 h) or 7 day (0, 24, 48, 72, 96,120,144, and 166 h) treatment regimen. DCEMRI was employed 2 h after the last dose of ZD4190, using the contrast agent gadopentetate dimeglumine. Dynamic data were fit to a compartmental model to obtain voxelwise K(trans), the transfer constant for gadopentetate into the tumor. K(trans) was averaged over the entire tumor, and a multi-threshold histogram analysis was also employed to account for tumor heterogeneity. Reductions in K(trans) reflect reductions in flow, in endothelial surface area, and/or in vascular permeability. A vascular input function was obtained for each mouse simultaneously with the tumor DCEMRI data. ZD4190 treatment produced a dose-dependent (12.5-100 mg x kg(-1) per dose) reduction in K(trans) in PC-3 prostate tumors. At 100 mg x kg(-1), the largest concentration examined, ZD4190 reduced K(trans) in PC-3 tumors by 31% following 2 doses (1 day treatment regimen; p < 0.001) and by 53% following 8 doses (7 day regimen; p < 0.001). Comparative studies in the three models using a showed similar reductions in K(trans) for the lung and breast tumors using the histogram analysis, although the statistical significance was lost when K(trans) was averaged over the entire tumor. Collectively these studies suggest that DCEMRI using gadopentetate may have potential clinically, for monitoring inhibition of VEGF signaling in solid tumors.

Animals↗

A minimum description length approach to statistical shape modeling.

We describe a method for automatically building statistical shape models from a training set of example boundaries/surfaces. These models show considerable promise as a basis for segmenting and interpreting images. One of the drawbacks of the approach is, however, the need to establish a set of dense correspondences between all members of a set of training shapes. Often this is achieved by locating a set of "landmarks" manually on each training image, which is time consuming and subjective in two dimensions and almost impossible in three dimensions. We describe how shape models can be built automatically by posing the correspondence problem as one of finding the parameterization for each shape in the training set. We select the set of parameterizations that build the "best" model. We define "best" as that which minimizes the description length of the training set, arguing that this leads to models with good compactness, specificity and generalization ability. We show how a set of shape parameterizations can be represented and manipulated in order to build a minimum description length model. Results are given for several different training sets of two-dimensional boundaries, showing that the proposed method constructs better models than other approaches including manual landmarking-the current gold standard. We also show that the method can be extended straightforwardly to three dimensions.

Algorithms↗

Gradient echo MRI characterization of development of atherosclerosis in the abdominal aorta in Watanabe Heritable Hyperlipidemic rabbits.

PURPOSE: The Watanabe Heritable Hyperlipidemic (WHHL) rabbit provides an important model of spontaneous atherosclerosis. With a strain of WHHL rabbits which do not develop abdominal aorta lumen stenosis even with advanced atherosclerosis, we studied the MRI-histology correlation, and the natural progression of atherosclerosis in the abdominal aorta. In addition, intra-reader segmentation repeatability and scan-rescan reproducibility were assessed. METHODS: Two batches of female WHHL rabbits were used. The first batch of 6 rabbits was scanned at 20 weeks old. A second batch of 17 rabbits was scanned at 50 weeks old and then randomly divided into two subgroups: 8 were killed for histologic investigation; 9 were kept alive for follow-up, with repeat scanning a week later to assess scan-rescan reproducibility, and again at 73 weeks old to assess disease progression. MR images were acquired at 4.7 T using a chemical shift selective fat suppression gradient echo with a saturation band suppressing blood signal within the aortic lumen. Five slices per animal were acquired, centered around the renal artery region of the abdominal aorta, with in-plane resolution of 0.195 mm and slice thickness of 3 mm. RESULTS: The coefficient of variation for intra-reader reproducibility for aortic wall thickness measurements was 2.5% for repeat segmentations of the same scans on the same day, but segmentations of these same scans made 8 months later showed a systematic change, suggesting that intra-reader bias as well as increased variability could compromise assessments made over time. Comparative analyses were therefore performed in one postprocessing session. The coefficient of variation for scan-rescan reproducibility for aortic wall thickness was 5.5% for nine pairs of scans acquired a week apart and segmented on the same day. Good MRI-histology correlation was obtained. The MRI-measured mean aortic wall thickness of animals at 20 weeks of age was 76% that of animals at 50 weeks of age (p < 0.001). There was a small increase in aortic wall thickness between 50 and 73 weeks of age, but this was not significant (p > 0.05). The corresponding differences in lumen cross-sectional areas at 20, 50, and 73 weeks of age were not significant. These results were consistent with in-house historical histology data on this strain of rabbits. CONCLUSIONS: High-resolution gradient echo MRI can follow disease progression in the WHHL rabbit spontaneous atherosclerosis disease model.

Aging↗

Single dose of the antivascular agent, ZD6126 (N-acetylcolchinol-O-phosphate), reduces perfusion for at least 96 hours in the GH3 prolactinoma rat tumor model.

Tumor vasculature is an attractive therapeutic target as it differs structurally from normal vasculature, and the destruction of a single vessel can lead to the death of many tumor cells. The effects of antivascular drugs are frequently short term, with regrowth beginning less than 24 hours posttreatment. This study investigated the duration of the response to the vascular targeting agent, ZD6126, of the GH3 prolactinoma, in which efficacy and dose-response have previously been demonstrated. GH3 prolactinomas were grown in the flanks of eight Wistar Furth rats. All animals were treated with 50 mg/kg ZD6126. The tumors were examined with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) 24 hours pretreatment and posttreatment, and at a single time between 48 and 96 hours posttreatment. No evidence of recovery of perfusion was observed even at the longest (96-hour) time point. Involvement of a statistician at the project planning stage and the use of DCE-MRI, which permits noninvasive quantitation of parameters related to blood flow in intact animals, allowed this highly significant result to be obtained using only eight rats.

Animals↗