HBM functional imaging analysis contest data analysis in wavelet space.

An analysis of the Functional Imaging Analysis Contest (FIAC) data is presented using spatial wavelet processing. This technique allows the image to be filtered adaptively according to the data itself, rather than relying on a predetermined filter. This adaptive filtering leads to better estimation of the parameters and contrasts in terms of mean squared error. It will be shown that by introducing a slight bias into the estimation, a large reduction in the variance can be achieved, leading to better overall mean squared error estimates. As no single filter needs to be preselected, results containing many scales of information can be found. In the FIAC data, it is shown that both small-scale and large-scale (smoother, more dispersed) effects occur. The combination of small- and large-scale effects detected in the FIAC data would be easy to miss using conventional single filter analysis.

Algorithms↗

A method for generating reproducible evidence in fMRI studies.

Insights into cognitive neuroscience from neuroimaging techniques are now required to go beyond the localisation of well-known cognitive functions. Fundamental to this is the notion of reproducibility of experimental outcomes. This paper addresses the central issue that functional magnetic resonance imaging (fMRI) experiments will produce more desirable information if researchers begin to search for reproducible evidence rather than only p value significance. The study proposes a methodology for investigating reproducible evidence without conducting separate fMRI experiments. The reproducible evidence is gathered from the separate runs within the study. The associated empirical Bayes and ROC extensions of the linear model provide parameter estimates to determine reproducibility. Empirical applications of the methodology suggest that reproducible evidence is robust to small sample sizes and sensitive to both the magnitude and persistency of brain activation. It is demonstrated that research findings in fMRI studies would be more compelling with supporting reproducible evidence in addition to standard hypothesis testing evidence.

Algorithms↗

Wavelet variance components in image space for spatiotemporal neuroimaging data.

Neuroimaging studies place great emphasis on not only the estimation but also the standard error estimates of underlying parameters derived from a temporal model. This allows inferences to be made about the signal estimates and resulting conclusions to be drawn about the underlying data. It can often be advantageous to interrogate temporal models after spatial transformation of the data into the wavelet domain. Wavelet bases provide a multiresolution decomposition of the spatial data dimension and an ensuing reduction in spatial correlation. However, widespread acceptance of these wavelet techniques has been hampered by the limited ability to reconstruct both parametric and error estimates into the image domain after analysis of temporal models in the wavelet domain. This paper introduces a derivation and a fast implementation of a method for the calculation of the variance of the parametric images obtained from wavelet filters. The technique is proposed for a class of estimators that have been shown to be useful in neuroimaging studies. The techniques are demonstrated for both functional magnetic resonance imaging (fMRI) and positron emission tomography (PET) data sets.

Analysis of Variance↗

On the logic of hypothesis testing in functional imaging.

Statistics is nowadays the customary language of functional imaging. It is common to express an experimental setting as a set of null hypotheses over complex models and to present results as maps of p-values derived from sophisticated probability distributions. However, the growing interest in the development of advanced statistical algorithms is not always paralleled by similar attention to how these techniques may regiment the ways in which users draw inferences from their data. This article investigates the logical bases of current statistical approaches in functional imaging and probes their suitability to inductive inference in neuroscience. The frequentist approach to statistical inference is reviewed with attention to its two main constituents: Fisherian "significance testing" and Neyman-Pearson "hypothesis testing". It is shown that these conceptual systems, which are similar in the univariate testing case, dissociate into two quite different methods of inference when applied to the multiple testing problem, the typical framework of functional imaging. This difference is explained with reference to specific issues, like small volume correction, which are most likely to generate confusion in the practitioner. Further insight into this problem is achieved by recasting the multiple comparison problem into a multivariate Bayesian formulation. This formulation introduces a new perspective where the inferential process is more clearly defined in two distinct steps. The first one, inductive in form, uses exploratory techniques to acquire preliminary notions on the spatial patterns and the signal and noise characteristics. The (smaller) set of likely spatial patterns generated is then tested with newer data and a more rigorous multiple hypothesis testing technique (deductive step).

Algorithms↗

Rank-shaping regularization of exponential spectral analysis for application to functional parametric mapping.

Compartmental models are widely used for the mathematical modelling of dynamic studies acquired with positron emission tomography (PET). The numerical problem involves the estimation of a sum of decaying real exponentials convolved with an input function. In exponential spectral analysis (SA), the nonlinear estimation of the exponential functions is replaced by the linear estimation of the coefficients of a predefined set of exponential basis functions. This set-up guarantees fast estimation and attainment of the global optimum. SA, however, is hampered by high sensitivity to noise and, because of the positivity constraints implemented in the algorithm, cannot be extended to reference region modelling. In this paper, SA limitations are addressed by a new rank-shaping (RS) estimator that defines an appropriate regularization over an unconstrained least-squares solution obtained through singular value decomposition of the exponential base. Shrinkage parameters are conditioned on the expected signal-to-noise ratio. Through application to simulated and real datasets, it is shown that RS ameliorates and extends SA properties in the case of the production of functional parametric maps from PET studies.

Algorithms↗

A linear wavelet filter for parametric imaging with dynamic PET.

This paper describes a new filter for parametric images obtained from dynamic positron emission tomography (PET) studies. The filter is based on the wavelet transform following the heuristics of a previously published method that are here developed into a rigorous theoretical framework. It is shown that the space-time problem of modeling a dynamic PET sequence reduces to the classical one of estimation of a normal multivariate vector of independent wavelet coefficients that, under least-squares risk, can be solved by straightforward application of well established theory. From the study of the distribution of wavelet coefficients of PET images, it is inferred that a James-Stein linear estimator is more suitable for the problem than traditional nonlinear procedures that are incorporated in standard wavelet filters. This is confirmed by the superior performance of the James-Stein filter in simulation studies compared to a state-of-the-art nonlinear wavelet filter and a nonstationary filter selected from literature. Finally, the formal framework is interpreted for the practitioner's point of view and advantages and limitations of the method are discussed.

Aged↗

Positron emission tomography partial volume correction: estimation and algorithms.

Partial volume effects in positron emission tomography (PET) lead to quantitative under- and over-estimations of the regional concentrations of radioactivity in reconstructed images and corresponding errors in derived functional or parametric images. The limited resolution of PET leads to "tissue-fraction" effects, reflecting underlying tissue heterogeneity, and "spillover" effects between regions. Addressing the former problem in general requires supplementary data, for example, coregistered high-resolution magnetic resonance images, whereas the latter effect can be corrected for with PET data alone if the point-spread function of the tomograph has been characterized. Analysis of otherwise homogeneous region-of-interest data ideally requires a combination of tissue classification and correction for the point-spread function. The formulation of appropriate algorithms for partial volume correction (PVC) is dependent on both the distribution of the signal and the distribution of the underlying noise. A mathematical framework has therefore been developed to accommodate both of these factors and to facilitate the development of new PVC algorithms based on the description of the problem. Several methodologies and algorithms have been proposed and implemented in the literature in order to address these problems. These methods do not, however, explicitly consider the noise model while differing in their underlying assumptions. The general theory for estimation of regional concentrations, associated error estimation, and inhomogeneity tests are presented in a weighted least squares framework. The analysis has been validated using both simulated and real PET data sets. The relations between the current algorithms and those published previously are formulated and compared. The incorporation of tensors into the formulation of the problem has led to the construction of computationally rapid algorithms taking into account both tissue-fraction and spillover effects. The suitability of their application to dynamic and static images is discussed.

Algorithms↗

Positron emission tomography compartmental models: a basis pursuit strategy for kinetic modeling.

A kinetic modeling approach for the quantification of in vivo tracer studies with dynamic positron emission tomography (PET) is presented. The approach is based on a general compartmental description of the tracer's fate in vivo and determines a parsimonious model consistent with the measured data. The technique involves the determination of a sparse selection of kinetic basis functions from an overcomplete dictionary using the method of basis pursuit denoising. This enables the characterization of the systems impulse response function from which values of the systems macro parameters can be estimated. These parameter estimates can be obtained from a region of interest analysis or as parametric images from a voxel-based analysis. In addition, model order estimates are returned that correspond to the number of compartments in the estimated compartmental model. Validation studies evaluate the methods performance against two preexisting data led techniques, namely, graphical analysis and spectral analysis. Application of this technique to measured PET data is demonstrated using [11C]diprenorphine (opiate receptor) and [11C]WAY-100635 (5-HT1A receptor). Although the method is presented in the context of PET neuroreceptor binding studies, it has general applicability to the quantification of PET/SPECT radiotracer studies in neurology, oncology, and cardiology.