Displacement-based binning of time-dependent computed tomography image data sets.

Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment have recently used a technique developed for cardiac CT imaging to track respiratory-induced anatomical motion and to sort images according to the phase of the respiratory cycle they represent. Here we propose a method of generating CT images that accounts for respiratory-induced anatomical motion on the basis of displacement, i.e., displacement-binned CT image sets. This technique has shown great promise, however, it is not fully supported by currently used CT image reconstruction software. As an interim solution, we have developed a method for extracting displacement-binned CT image data sets from data sets assembled on the basis of a prospectively determined breathing phase acquired on a multislice helical CT scanner. First, the projection data set acquired from the CT scanner was binned at small phase intervals before reconstruction. The manufacturer's software then generated image sets identified as belonging to particular phases of the respiratory cycle. All images were then individually correlated to the displacement of an external fiducial marker. Next, CT image data sets were resorted on the basis of the displacement and assigned an appropriate phase. Finally, displacement-binned image data sets were transferred to a treatment-planning system for analysis. Although the technique is currently limited by the phase intervals allowed by the CT software, some improvement in image reconstruction was seen, indicating that this technique is useful at least as an interim measure.

Algorithms↗

Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a standard verification data set.

A commercial electron dose calculation software implementation based on the macro Monte Carlo algorithm has recently been introduced. We have evaluated the performance of the system using a standard verification data set comprised of two-dimensional (2D) dose distributions in the transverse plane of a 15 X 15 cm2 field. The standard data set was comprised of measurements performed for combinations of 9-MeV and 20-MeV beam energies and five phantom geometries. The phantom geometries included bone and air heterogeneities, and irregular surface contours. The standard verification data included a subset of the data needed to commission the dose calculation. Additional required data were obtained from a dosimetrically equivalent machine. In addition, we performed 2D dose measurements in a water phantom for the standard field sizes, a 4 cm X 4 cm field, a 3 cm diameter circle, and a 5 cm X 13 cm triangle for the 6-, 9-, 12-, 15-, and 18-MeV energies of a Clinac 21EX. Output factors were also measured. Synthetic CT images and structure contours duplicating the measurement configurations were generated and transferred to the treatment planning system. Calculations for the standard verification data set were performed over the range of each of the algorithm parameters: statistical precision, grid-spacing, and smoothing. Dose difference and distance-to-agreement were computed for the calculation points. We found that the best results were obtained for the highest statistical precision, for the smallest grid spacing, and for smoothed dose distributions. Calculations for the 21EX data were performed using parameters that the evaluation of the standard verification data suggested would produce clinically acceptable results. The dose difference and distance-to-agreement were similar to that observed for the standard verification data set except for the portion of the triangle field narrower than 3 cm for the 6- and 9-MeV electron beams. The output agreed with measurements to within 2%, with the exception of the 3-cm diameter circle and the triangle for 6 MeV, which were within 5%. We conclude that clinically acceptable results may be obtained using a grid spacing that is no larger than approximately one-tenth of the distal falloff distance of the electron depth dose curve (depth from 80% to 20% of the maximum dose) and small relative to the size of heterogeneities. For judicious choices of parameters, dose calculations agree with measurements to better than 3% dose difference and 3-mm distance-to-agreement for fields with dimensions no less than about 3 cm.

Journal Article↗

Application of the electron pencil beam redefinition algorithm to electron arc therapy.

This project investigated the potential of summing fixed-beam dose distributions calculated using the pencil-beam redefinition algorithm (PBRA) at small angular steps (1 degree) to model an electron arc therapy beam. The PRBA, previously modified to model skin collimation, was modified further by incorporating two correction factors. One correction factor that is energy, SSD (source-to-surface distance), and field-width dependent constrained the calculated dose output to be the same as the measured dose output for fixed-beam geometries within the range of field widths and SSDs encountered in arc therapy. Another correction factor (single field-width correction factor for each energy) compensated for large-angle scattering not being modeled, allowing a more accurate calculation of dose output at mid arc. The PBRA was commissioned to accurately calculate dose in a water phantom for fixed-beam geometries typical of electron arc therapy. Calculated central-axis depth doses agreed with measured doses to within 2% in the low-dose gradient regions and within 1-mm in the high-dose gradient regions. Off-axis doses agreed to within 2 mm in the high-dose gradient regions and within 3% in the low-dose gradient regions. Arced-beam calculations of dose output and depth dose at mid arc were evaluated by comparing to data measured using two cylindrical water phantoms with radii of 12 and 15 cm at 10 and 15 MeV. Dose output was measured for all combinations of phantom radii of curvature, collimator widths (4, 5, and 6 cm), and arc angles (0 degrees, 20 degrees, 40 degrees, 60 degrees, 80 degrees, and 90 degrees) for both beam energies. Results showed the calculated mid-arc dose output to agree within 2% of measurement for all combinations. For a 90 degree arc angle and 5 x 20 cm2 field size, the calculated mid-arc depth dose in the low-dose gradient region agreed to within 2% of measurement for all depths at 10 MeV and for depths greater than depth of dose maximum R100 at 15 MeV. For depths in the buildup region at 15 MeV the calculations overestimated the measured dose by as much as 3.4%. Mid-arc depth dose in the high-dose gradient region agreed to within 2.2 mm of measured dose. Calculated two-dimensional relative dose distributions in the plane of rotation were compared to dose measurements using film in a cylindrical polystyrene phantom for a 90 degree arc angle and field widths of 4, 5, and 6 cm at 10 and 15 MeV. Results showed that off-axis dose at the ends of arc (without skin collimation) agreed to within 2% in the low-dose gradient region and to within 1.2 mm in the high-dose gradient region. This work showed that the accuracy of the PBRA arced-beam dose model met the criteria specified by Van Dyk et al. [Int. J. Radiat. Oncol. Biol. Phys. 26, 261-273 (1993)] with the exception of the buildup region of the 15 MeV beam. Based on the present results, results of a previous study showing acceptable accuracy in the presence of skin collimation, and results of a previous study showing acceptable accuracy in the presence of internal heterogeneities, it is concluded that the PBRA arced-beam dose model should be adequate for planning electron arc therapy.

Algorithms↗

A novel platform simulating irregular motion to enhance assessment of respiration-correlated radiation therapy procedures.

Respiratory motion continues to present challenges in the delivery of radiation therapy to tumors in the thorax and abdomen by causing movement of structures within those areas. Several approaches to account for this movement in the planning and delivery of treatment have been developed over the past several years. To assist in the development and assessment of various techniques for respiration-correlated radiation therapy, a platform capable of programmable irregular longitudinal motion has been designed and fabricated to simulate intrafractional respiratory motion. A sliding platform and the base on which it was mounted were constructed from polycarbonate plastic, and a stepper motor provided platform motion. Respiratory motion data, either artificially generated on a spreadsheet or extracted from respiratory monitoring files, were converted to a format appropriate for driving the stepper motor. Various phantoms were placed on top of the platform and used in studies related to respiration-correlated radiation therapy. Several applications of the platform were demonstrated, such as improving the quality of acquisition of time-dependent computed tomography image datasets, comparing various methods of acquiring such datasets, and implementing feedback-guided breath hold treatment delivery procedures. This study showed that a platform capable of programmable irregular motion is a useful tool for the development and assessment of procedures related to the effects of respiratory motion in radiation therapy.

Artifacts↗

Respiration-correlated treatment delivery using feedback-guided breath hold: a technical study.

Respiratory motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. To reduce the uncertainties caused by this motion, we have developed feedback-guided breath hold (FGBH), a novel delivery technique in which radiation is delivered only during a voluntary breath hold that is sustained for as long as the patient feels comfortable. Here we present the technical aspects of FGBH, which involve (1) fabricating the hardware so the respiratory trace can be displayed to the patient, (2) assembling a delay box to be used as a breath-hold detector, and (3) performing quality control tests to ensure that FGBH can be delivered accurately and safely. A commercial respiratory tracking system that uses an external fiducial to monitor abdominal wall motion generates and displays the breathing trace and specific positions in the breathing cycle where a breath hold needs to occur. Hardware was developed to present this display to the patient in the treatment position. Patients view the presentation either on a liquid crystal display or through a pair of virtual reality goggles. Using the respiratory trace as a visual aid, the patient performs a breath hold so that the position representing the location of a fiducial is held within a specified gating window. A delay box was fabricated to differentiate between gating signals received during free breathing and those received during breath hold, allowing radiation delivery only when the fiducial was within the breath-hold gating window. A quality control analysis of the gating delay box and the integrated system was performed to ensure that all of the hardware and components were ready for clinical use.

Abdomen↗

Modeling skin collimation using the electron pencil beam redefinition algorithm.

Skin collimation is an important tool for electron beam therapy that is used to minimize the penumbra when treating near critical structures, at extended treatment distances, with bolus, or using arc therapy. It is usually made of lead or lead alloy material that conforms to and is placed on patient surface. Presently, commercially available treatment-planning systems lack the ability to model skin collimation and to accurately calculate dose in its presence. The purpose of the present work was to evaluate the use of the pencil beam redefinition algorithm (PBRA) in calculating dose in the presence of skin collimation. Skin collimation was incorporated into the PBRA by terminating the transport of electrons once they enter the skin collimator. Both fixed- and arced-beam dose calculations for arced-beam geometries were evaluated by comparing them with measured dose distributions for 10- and 15-MeV beams. Fixed-beam dose distributions were measured in water at 88-cm source-to-surface distance with an air gap of 32 cm. The 6 x 20-cm2 field (dimensions projected to isocenter) had a 10-mm thick lead collimator placed on the surface of the water with its edge 5 cm inside the field's edge located at +10 cm. Arced-beam dose distributions were measured in a 13.5-cm radius polystyrene circular phantom. The beam was arced 90 degrees (-45 degrees to +45 degrees), and 10-mm thick lead collimation was placed at +/- 30 degrees. For the fixed beam at 10 MeV, the PBRA- calculated dose agreed with measured dose to within 2.0-mm distance to agreement (DTA) in the regions of high-dose gradient and 2.0% in regions of low dose gradient. At 15 MeV, the PBRA agreed to within a 2.0-mm DTA in the regions of high-dose gradient; however, the PBRA underestimated the dose by as much as 5.3% over small regions at depths less than 2 cm because it did not model electrons scattered from the edge of the skin collimation. For arced beams at 10 MeV, the agreement was 1-mm DTA in the high-dose gradient regions, and 2% in the low-dose gradient regions. For arced beams at 15 MeV, the agreement was 1 mm in the high-dose gradient regions, and in the low-dose gradient region at depth less than 2 cm, as much as 5% dose difference was observed. This study demonstrated the ease with which skin collimation can be incorporated into the PBRA. The good agreement of PBRA calculated with measured dose shows that the PBRA is likely sufficiently accurate for clinical use in the presence of skin collimation for electron arc therapy. To further improve the accuracy of the PBRA in regions having significant electrons scattered from the edge of the skin collimation would require transporting the electrons through the lead skin collimation near its edges.

Algorithms↗

Dosimetry of a prototype retractable eMLC for fixed-beam electron therapy.

An electron multileaf collimator (eMLC) has been designed that is unique in that it retracts to 37 cm from the isocenter [63-cm source-to-collimator distance (SCD)] and can be deployed to distances of 20 and 10 cm from the isocenter (80 and 90 cm SCD, respectively). It is expected to be capable of arc therapy at 63 cm SCD; isocentric, fixed-beam therapy at 80 cm SCD; and source-to-surface distance (SSD), fixed-beam therapy at 90 cm SCD. In all positions, its leaves could be used for unmodulated or intensity-modulated therapy. Our goal in the present work is to describe the general characteristics of the eMLC and to demonstrate that its leakage characteristics and dosimetry are adequate for SSD, fixed-beam therapy as an alternative to Cerrobend cutouts with applicators once the prototype's leaves are motorized. Our eMLC data showed interleaf electron leakage at 15 MeV to be less than 0.1% based on a 0.0025 cm manufacturing tolerance, and lateral electron leakage at 5 and 15 MeV to be less than 2%. X-ray leakage through the leaves was 1.6% at 15 MeV. Our data showed that beam penumbra was independent of direction and leaf position. The dosimetric properties of square fields formed by the eMLC were very consistent with those formed by Cerrobend inserts in the 20 x 20 cm2 applicator. Output factors exhibited similar field-size dependence. Airgap factors exhibited almost identical field-size dependence at two SSDs (105 and 110 cm), consistent with the common assumption that airgap factors are applicator independent. Percent depth-dose curves were similar, but showed variations up to 3% in the buildup region. The pencil-beam algorithm (PBA) fit measured data from the eMLC and applicator-cutout systems equally well, and the resulting two-dimensional (2-D) dose distributions, as predicted by the PBA, agreed well at common airgap distance. Simulating patient setups for breast and head and neck treatments showed that almost all fields could be treated using similar SSDs as when using applicators, although head and neck treatments require placing the patient's head on a head-holder treatment table extension. The results of this work confirmed our design goals and support the potential use of the eMLC design in the clinical setting. The eMLC should allow the same treatments as are typically delivered with the electron applicator-cutout system currently used for fixed-beam therapy.

Air↗

Prostate biopsy status and PSA nadir level as early surrogates for treatment failure: analysis of a prostate cancer randomized radiation dose escalation trial.

PURPOSE: A positive biopsy after external beam radiotherapy in patients free of any evidence of treatment failure is not synonymous with eventual recurrence. Although biopsy positivity is a predictor of outcome, the utility of biopsy status as a surrogate end point, the effect of radiation dose on biopsy status, and the interrelationships of these associations to prostate-specific antigen (PSA) nadir level are not well-defined. These issues were investigated in a cohort of men with Stage T1-T3 prostate cancer who were randomized to receive between 70 Gy and 78 Gy and were prospectively biopsied at about 2 years after the completion of radiotherapy (RT). METHODS AND MATERIALS: Of the 301 assessable patients in the trial, 168 underwent planned sextant or greater prostate post-RT biopsies in the absence of biochemical or clinical failure; this group constituted the study cohort. Of the 168 patients, 87 were in the 70-Gy arm and 81 in the 78-Gy arm. Biopsies were classified into four groups: negative (no tumor), atypical/suspicious cells (not diagnostic of carcinoma), carcinoma with treatment effect (CaTxEffect), and carcinoma without treatment effect (CaNoTxEffect). Any diagnosis of carcinoma in the specimen was classified as biopsy positive. Freedom from failure (FFF) included biochemical failure and/or clinical failure. Kaplan-Meier curves were calculated from the completion of RT. For those alive in the study cohort, the median follow-up was 65 months. RESULTS: The rate of biopsy without tumor was 42%; with atypical cells, it was 28%, with CaTxEffect 21%, and with CaNoTxEffect 9%. The overall biopsy positivity rate (CaTxEffect + CaNoTxEffect) was 30%; 28% in the 70-Gy group and 32% in the 78-Gy group (p = 0.52). The distribution of PSA nadir levels was 73% 0.5-1.0, 5% >1.0-2.0, and 1% >2.0 ng/mL. Significantly more patients randomized to 78 Gy had a PSA nadir of 2.0 ng/mL. CONCLUSION: For patients free of treatment failure at the time of prostate biopsy 2 years after RT, the prognosis of no tumor cells was the same as that of atypical/suspicious cells and CaTxEffect was the same as CaNoTxEffect. The biopsy positivity rate was not altered by dose, suggesting that most of the outcome differences between the 70-Gy and 78-Gy groups were due to events occurring before prostate biopsy at 2 years and/or were not entirely dependent on biopsy status. Biopsy status is a strong prognostic factor, but, as an early end point, it may be misleading. PSA nadir appears to have little clinical value in patients treated to doses of >/=70 Gy who are failure free 2 years after RT.

Aged↗

Prostate cancer radiation dose response: results of the M. D. Anderson phase III randomized trial.

PURPOSE: A randomized radiotherapy dose escalation trial was undertaken between 1993 and 1998 to compare the efficacy of 70 vs. 78 Gy in controlling prostate cancer. METHODS AND MATERIALS: A total of 305 Stage T1-T3 patients were entered into the trial and, of these, 301 with a median follow-up of 60 months, were assessable. Of the 301 patients, 150 were in the 70 Gy arm and 151 were in the 78 Gy arm. The primary end point was freedom from failure (FFF), including biochemical failure, which was defined as 3 rises in the prostate-specific antigen (PSA) level. Kaplan-Meier survival analyses were calculated from the completion of radiotherapy. The log-rank test was used to compare the groups. Cox proportional hazard regression analysis was used to examine the independence of study randomization in multivariate analysis. RESULTS: There was an even distribution of patients by randomization arm and stage, Gleason score, and pretreatment PSA level. The FFF rates for the 70- and 78 Gy arms at 6 years were 64% and 70%, respectively (p = 0.03). Dose escalation to 78 Gy preferentially benefited those with a pretreatment PSA >10 ng/mL; the FFF rate was 62% for the 78 Gy arm vs. 43% for those who received 70 Gy (p = 0.01). For patients with a pretreatment PSA 10 ng/mL who were treated to 78 Gy (98% vs. 88% at 6 years, p = 0.056). Rectal side effects were also significantly greater in the 78 Gy group. Grade 2 or higher toxicity rates at 6 years were 12% and 26% for the 70 Gy and 78 Gy arms, respectively (p = 0.001). Grade 2 or higher bladder complications were similar at 10%. For patients in the 78 Gy arm, Grade 2 or higher rectal toxicity correlated highly with the proportion of the rectum treated to >70 Gy. CONCLUSION: An increase of 8 Gy resulted in a highly significant improvement in FFF for patients at intermediate-to-high risk, although the rectal reactions were also increased. Dose escalation techniques that limit the rectal volume that receives >or=70 Gy to <25% should be used.

Aged↗

Electron conformal radiotherapy using bolus and intensity modulation.

PURPOSE: Conformal electron beam therapy can be delivered using shaped bolus, which varies the penetration of the electrons across the incident beam so that the 90% isodose surface conforms to the distal surface of the planning target volume (PTV). Previous use of this modality has shown that the irregular proximal surface of the bolus causes the dose heterogeneity in the PTV to increase from 10%, the typical dose spread of a flat-water surface to approximately 20%. The present work evaluates the ability to restore dose homogeneity by varying the incident electron intensity. METHODS AND MATERIALS: Three patients, one each with chest wall, thorax, and head-and-neck cancer, were planned using electron conformal therapy with bolus, with and without intensity modulation. Resulting dose distributions and dose-volume histograms were compared with non-intensity-modulated bolus plans. RESULTS: In all cases, the DeltaD(90%-10%) for the PTV was reduced; for example, for the head-and-neck case, the DeltaD(90%-10%) for the PTV was reduced from 14.9% to 9.2%. This reduction in dose spread is a direct result of intensity modulation. CONCLUSIONS: The results showed that intensity-modulated electron beams could significantly improve the dose homogeneity in the PTV for patients treated with electron conformal therapy using shaped bolus.

Adult↗

Using Monte Carlo methods to commission electron beams: a feasibility study.

The purpose of this study was to investigate the feasibility of using Monte Carlo methods to assist in the commissioning of electron beams for a medical linear accelerator. The EGS4/BEAM code system was used to model an installed linear accelerator at this institution. Following an initial tuning of the input parameters, dosimetry data normally measured during the machine commissioning was calculated using the Monte Carlo code. All commissioning data was calculated for 6- and 12-MeV electron beams, and a subset of the commissioning data was calculated for the 20-MeV electron beams. On central axis, calculated percentage depth dose, cross-beam profiles, cone-insert ratios, and air-gap factors were generally within 2% of Dmax or 1 mm of the measured commissioning data; however, calculated open-cone ratios were not within 2%, in most cases. Calculated off-axis dose profiles for small fields were generally within the 2% (1-mm) criteria; however, calculated dose profiles for larger (open cone) fields frequently failed the 2% (1-mm) criteria. The remaining discrepancies between Monte Carlo calculations and measurement could be due to flaws in the Monte Carlo code, inaccuracies in the simulation geometry, the approximation of the initial source configuration, or a combination of the above. Although agreement between Monte Carlo calculated and measured doses was impressive and similar to previously published comparisons, our results did not prove our hypothesis that Monte Carlo calculations can generate electron commissioning data that is accurate within 2% of Dmax or 0.1 cm over the entire range of clinical treatment parameters. Although we believe that this hypothesis can be proved, it remains a challenge for the medical physics community. We intend to pursue this further by developing systematic methods for isolating causes of these differences.

Air↗

The use of an extra-focal electron source to model collimator-scattered electrons using the pencil-beam redefinition algorithm.

Currently, the pencil-beam redefinition algorithm (PBRA) utilizes a single electron source to model clinical electron beams. In the single-source model, the electrons appear to originate from a virtual source located near the scattering foils. Although this approach may be acceptable for most treatment machines, previous studies have shown dose differences as high as 8% relative to the given dose for small fields for some machines such as the Varian Clinac 1800. In such machines collimation-scattered electrons originating from the photon jaws and the applicator give rise to extra-focal electron sources. In this study, we examined the impact of modeling an additional electron source to better account for the collimator-scattered electrons. The desired dose calculation accuracy in water throughout the dose distribution is 3% or better relative to the given dose. We present here a methodology for determining the electron-source parameters for the dual-source model using a minimal set of data, that is, two central-axis depth-dose curves and two off-axis profiles. A Varian Clinac 1800 accelerator was modeled for beam energies of 20 and 9 MeV and applicator sizes of 15 x 15 and 6 x 6 cm2. The improvement in the accuracy of PBRA-calculated dose, evaluated using measured two-dimensional dose distributions in water, was characterized using the figure of merit, FA3%, which represents the fractional area containing dose differences greater than 3%. For the 15 x 15 cm2 field the evaluation was restricted to the penumbral region, and for the 6 x 6 cm2 field the central region of the beam was included as it was impacted by the penumbra. The greatest improvement in dose accuracy was for the 6 x 6 cm2 applicator. At 9 MeV, FA3% decreased from 15% to 0% at 100 cm SSD and from 34% to 4% at 110 cm SSD. At 20 MeV, FA3% decreased from 17% to 2% at 100 cm SSD and from 41% to 10% at 110 cm SSD. In the penumbra of the 15 x 15 cm2 applicator, the improvement was less, but still significant. At 9 MeV, FA3% changed from 11% to 1% at 100 cm SSD and from 10% to 12% at 110 cm SSD. At 20 MeV, FA3% decreased from 12% to 8% at 100 cm SSD and from 14% to 5% at 110 cm SSD. Results demonstrate that use of a dual-source beam model can provide significantly improved accuracy in the PBRA-calculated dose distribution that was not achievable with a single-source beam model when modeling the Varian Clinac 1800 electron beams. Time of PBRA dose calculation was approximately doubled; however, dual-source beam modeling of newer accelerators (e.g., the Varian Clinac 2100) may not be necessary because of less impact of collimator-scattered electrons on dosimetry.

Algorithms↗

PTV margin determination in conformal SRT of intracranial lesions.

The planning target volume (PTV) includes the clinical target volume (CTV) to be irradiated and a margin to account for uncertainties in the treatment process. Uncertainties in miniature multileaf collimator (mMLC) leaf positioning, CT scanner spatial localization, CT-MRI image fusion spatial localization, and Gill-Thomas-Cosman (GTC) relocatable head frame repositioning were quantified for the purpose of determining a minimum PTV margin that still delivers a satisfactory CTV dose. The measured uncertainties were then incorporated into a simple Monte Carlo calculation for evaluation of various margin and fraction combinations. Satisfactory CTV dosimetric criteria were selected to be a minimum CTV dose of 95% of the PTV dose and at least 95% of the CTV receiving 100% of the PTV dose. The measured uncertainties were assumed to be Gaussian distributions. Systematic errors were added linearly and random errors were added in quadrature assuming no correlation to arrive at the total combined error. The Monte Carlo simulation written for this work examined the distribution of cumulative dose volume histograms for a large patient population using various margin and fraction combinations to determine the smallest margin required to meet the established criteria. The program examined 5 and 30 fraction treatments, since those are the only fractionation schemes currently used at our institution. The fractionation schemes were evaluated using no margin, a margin of just the systematic component of the total uncertainty, and a margin of the systematic component plus one standard deviation of the total uncertainty. It was concluded that (i) a margin of the systematic error plus one standard deviation of the total uncertainty is the smallest PTV margin necessary to achieve the established CTV dose criteria, and (ii) it is necessary to determine the uncertainties introduced by the specific equipment and procedures used at each institution since the uncertainties may vary among locations.

Brain Neoplasms↗