Search PubMed⌕ Search

Biomedical subjects

Joel S Schuman

Publications and source records attributed to Joel S Schuman.

At least 19 recordsLinked to original sources

Glaucoma detection with matrix and standard achromatic perimetry.

BACKGROUND: Matrix perimetry is a new iteration of frequency-doubling technology (FDT) which uses a smaller target size in the standard achromatic perimetry presentation pattern. AIM: To compare the performance of matrix and Swedish interactive thresholding algorithm (SITA) perimetry in detecting glaucoma diagnosed by structural assessment. DESIGN: Prospective cross-sectional study. METHODS: 76 eyes from 15 healthy subjects and 61 consecutive glaucoma suspects and patients with glaucoma were included. All patients underwent optic nerve head (ONH) photography, SITA and matrix perimetries, and optical coherence tomography (OCT) within a 6-month period. Glaucoma diagnosis was established by either glaucomatous optic neuropathy or OCT by assessing retinal nerve fibre layer (RNFL) thickness. Mean deviation (MD), pattern standard deviation (PSD), glaucoma hemifield test and cluster of abnormal testing locations were recorded from matrix and SITA perimetries. RESULTS: Similar correlations were observed with matrix and SITA perimetry MD and PSD with either cup-to-disc ratio or OCT mean RNFL. The area under the receiver operating characteristic (AROC) curves of MD and PSD for discriminating between healthy and glaucomatous eyes ranged from 0.69 to 0.81 for matrix perimetry and from 0.75 to 0.77 for SITA perimetry. There were no significant differences among any corresponding matrix and SITA perimetry AROCs. CONCLUSIONS: Matrix and SITA perimetries had similar capabilities for distinguishing between healthy and glaucomatous eyes regardless of whether the diagnosis was established by ONH or OCT-RNFL assessment.

Adult↗

Glaucoma detection with the Heidelberg retina tomograph 3.

PURPOSE: To compare the ability of the Heidelberg retina tomograph version 3 (HRT 3) and HRT version 2 (HRT 2) to discriminate between healthy and glaucomatous eyes. DESIGN: Retrospective cross-sectional study. PARTICIPANTS: Seventy-one eyes of 71 healthy volunteers and 50 eyes of 50 glaucoma patients were studied. The average visual field mean deviation of the glaucoma group was -6.03+/-5.78 dB. INTERVENTION: All participants had comprehensive ocular examinations, perimetry, and HRT scanning within 6 months. HRT 2 data were analyzed using HRT 3 software without modifying the disc margin. MAIN OUTCOME MEASURES: Discrimination capabilities between healthy and glaucomatous eyes were determined by areas under the receiver operating characteristics (AROCs) curves. Comparisons between corresponding AROCs obtained by HRT 2 and HRT 3 analyses were performed using the nonparametric DeLong method. Agreement between classifications as defined by the different analysis methods was quantified by kappa analysis. RESULTS: The individual stereometric parameters with the best discrimination were linear cup/disc ratio (AROC = 0.897; 95% confidence interval [CI], 0.836-0.958) for standard HRT 3 analysis and horizontal retinal nerve fiber layer curvature (0.905) for HRT 3 glaucoma probability score (GPS) analysis. Areas under the receiver operating characteristics for discrimination between glaucomatous and healthy eyes of the overall classification by HRT 2 Moorfields regression analysis (MRA), HRT 3 MRA, and GPS were 0.927 (95% CI, 0.877-0.977), 0.934 (0.888-0.980), and 0.880 (0.812-0.948), respectively. The difference between the 3 AROCs was not significant (P = 0.44). The agreement between HRT 2 and HRT 3 overall MRA classification was good (kappa = 0.70; CI, 0.59-0.80) with HRT 3 tending to report more abnormalities than HRT 2 analysis. The agreement between overall HRT 3 MRA and overall GPS was kappa = 0.58 (CI, 0.45-0.70). CONCLUSIONS: The glaucoma discriminating ability of the new HRT 3 software is similar to that of the previous generation HRT 2. The GPS analysis showed promising results in differentiating between healthy and glaucomatous eyes without the need for subjective operator input.

Adult↗

Comparison of visual field defects using matrix perimetry and standard achromatic perimetry.

PURPOSE: To compare visual field (VF) defects found by Swedish interactive thresholding Algorithm (SITA) perimetry and Matrix perimetry, a new VF device that utilizes frequency doubling technology in a 24-2 test pattern. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Fifty eyes from 50 subjects with SITA field defects were recruited for an observational study. METHODS: Swedish Interactive Threshold Algorithm and Matrix VF testing were performed on patients from a glaucoma practice. To evaluate the learning effect on the performance of the VF, we tested subsets of each group who had previous experience with standard automated perimetry (SAP). MAIN OUTCOME MEASURES: Test duration, mean threshold, mean deviation (MD), pattern standard deviation (PSD), glaucoma hemifield test, and number of abnormal points on the pattern deviation plot were evaluated for each device. RESULTS: Test duration was significantly shorter for Matrix (SITA, 357.0+/-85.6 seconds; Matrix, 319.5+/-16.5 seconds; P = 0.0002, paired t-test). Thirty-six percent of eyes with SITA VF defects showed a normal Matrix field. In 30 of 32 eyes (94%) where both devices showed VF defects, the defects were congruent. Mean threshold value was significantly lower with Matrix compared to SITA (P<0.0001, paired t-test), as was MD (-5.34+/-5.42 dB, -4.14+/-5.29 dB, respectively; P = 0.03, paired t-test). There was no significant difference in PSD between the 2 devices (P = 0.78, paired t-test). Matrix delineated significantly smaller (P = 0.005, Wilcoxon's test) and deeper (P<0.001, Wilcoxon's test) defects than those found with SITA. Similar results were observed in the subgroups with prior SAP experience. CONCLUSIONS: The Matrix examination did not detect 36% of abnormal SITA fields. Matrix field defects were smaller and deeper than those appearing in SITA perimetry.

Adult↗

Comparison of acute structural and histopathological changes in human autopsy eyes after endoscopic cyclophotocoagulation and trans-scleral cyclophotocoagulation.

AIM: To study the histological effects of trans-scleral cyclophotocoagulation (TCP) and endoscopic cyclophotocoagulation (ECP) on the ciliary body and other structures collected at autopsy and to compare with untreated controls. MATERIALS AND METHODS: TCP and ECP were performed on human eyes at autopsy. Detailed histological evaluations were perfomed using light microscopy and scanning electron microscopy on treated eyes and compared with untreated controls. RESULTS: Histological changes were observed with both light microscopy and scanning electron microscopy for all treated tissues. Tissue treated with TCP showed pronounced tissue disruption of the ciliary body muscle and stroma, ciliary processes, and both pigmented and non-pigmented ciliary epithelium. ECP-treated tissue exhibited pronounced contraction of the ciliary processes with disruption of the ciliary body epithelium, sparing of the ciliary body muscle and less architectural disorganisation. The sclera was not affected by either laser treatment. CONCLUSIONS: ECP treatment caused less damage to the ciliary body compared with TCP when evaluated by light microscopy and scanning electron microscopy. Compared with TCP, ECP seems to be a more selective form of cyclophotocoagulation, resulting in less tissue disruption while achieving the goal of destroying ciliary body epithelium.

Autopsy↗

Ultra-high resolution optical coherence tomography assessment of photoreceptors in retinitis pigmentosa and related diseases.

PURPOSE: To assess photoreceptor integrity in patients with retinitis pigmentosa (RP) and related diseases using ultra-high resolution optical coherence tomography (UHR-OCT) and to correlate foveal photoreceptor loss with visual acuity. DESIGN: Observational case series. METHODS: Nine eyes of nine patients with RP and related diseases were imaged with UHR-OCT at the ophthalmology clinic. Patients were diagnosed based on history, examination, fluorescein angiography, and electroretinography. Concurrently, 36 eyes of 36 normal subjects were imaged with UHR-OCT. Central foveal thickness (CFT) and foveal outer segment/pigment epithelium thickness (FOSPET) were defined and measured on UHR-OCT images in all subjects and were compared between the two groups using unpaired t tests. The two thickness measurements in RP patients were correlated with visual acuity using Pearson correlation and linear regression. RESULTS: UHR-OCT demonstrated macular photoreceptor thinning in all RP patients. The difference in CFT between RP patients and normal subjects was not statistically significant (P = .103), but the difference in FOSPET between the two groups was significant (P = .003). Visual acuity showed a fair correlation with CFT (Pearson r = -0.43, r(2) = 0.187, P = .245) and an excellent correlation with FOSPET (Pearson r = -0.942, r(2) = 0.887, P < .0001). CONCLUSIONS: In the current study using UHR-OCT, a new thickness measurement termed FOSPET is demonstrated to quantify photoreceptor loss. FOSPET was statistically thinner in patients with RP and related diseases than in normal eyes and showed correlation with logMAR visual acuity. FOSPET appears to be a probable predictor of visual acuity in RP.

Adult↗

Automated detection of clinically significant macular edema by grid scanning optical coherence tomography.

OBJECTIVE: To compare the detection of clinically significant diabetic macular edema (DME) by an optical coherence tomography (OCT) grid scanning protocol and biomicroscopic examination. DESIGN: Retrospective case series. PARTICIPANTS: Outpatients at the Doheny Eye Institute. METHODS: The clinical and imaging records of a consecutive series of 71 eyes of 40 patients referred for DME who underwent OCT using the both the Macular Grid 5 (MG5) scanning protocol (to allow a more evenly distributed sampling of points in the macula) and the standard Fast Macular Thickness Map (FMTM) pattern were reviewed. An automated algorithm was developed to generate a retinal thickness map using the MG5 data, which was then compared with a normative database to identify presumed areas of retinal edema. Clinically significant macular edema (CSME) was also identified by clinical examination and stereoscopic fundus photographs for comparison with the results of the OCT protocols. MAIN OUTCOME MEASURES: Sensitivity and specificity of scanning protocols. RESULTS: Optical coherence tomograms were inspected visually, and automatically detected retinal boundaries were found to be correct in 69 of 71 MG5 scans and in 65 of 71 FMTM scans. Macular Grid 5 scanning was performed twice in each eye, and the repeatability (pooled standard deviation) of the total area of edema was 0.48 mm2 (coefficient of variation, 6.8%). Sensitivity and specificity of the MG5 for detection of CSME relative to the clinical examination were 89% and 86%, respectively, with kappa being 0.74. Macular Grid 5 and FMTM assessment of foveal CSME also showed good agreement, with kappa being 0.68. CONCLUSIONS: The analysis algorithm for the OCT MG5 grid scan seems to be accurate and repeatable. Automated detection of CSME by the MG5 analysis correlated well with the clinical grading and standard OCT analysis (FMTM). Macular Grid 5 provides more information regarding the perifoveal macula than FMTM and may be of value to clinicians in planning treatment and in future studies of macular edema.

Algorithms↗

Constitutive signalling pathway activity in trabecular meshwork cells from glaucomatous eyes.

We recently described an IL-1-regulated stress response specific to the eye's aqueous outflow pathways that is diagnostic of glaucomas of diverse etiology. The goal of this study was to further identify IL-1-regulated signalling pathways in normal TM cells and determine whether their activity is altered in glaucomatous TM cells. Activity of the MAPK, p38, and JNK signalling pathways, represented by protein kinases ERK1/2, p38, and JNK-1, was followed by western blotting using antibodies specific for the active phosphorylated forms, after treatment of normal (N=5) or glaucomatous (N=5) cell lines by IL-1. Active forms of each of these kinases could be detected in normal and glaucomatous cells prior to treatment. When normal cells were stimulated with exogenous IL-1, an increase in activity of each of the kinases was observed. In contrast, treatment of glaucomatous cells with IL-1 resulted in little or no change in kinase activity. This difference was shown to be statistically significant by use of the paired two-tailed Student's t-test. Interference with IL-1 autocrine signalling in glaucomatous cell lines by treatment with IL-1 receptor antagonist (IL-1ra) had no effect on constitutive p38 or JNK activity (ERK was not examined). The results suggest that the MAPK, p38 and JNK signal transduction pathways are relatively unresponsive in glaucomatous cells as compared to normal cells. These results provide new information about the behaviour of glaucomatous TM cells, which may be important for understanding the pathophysiology of high-tension glaucoma.

Cadaver↗

Normal macular thickness measurements in healthy eyes using Stratus optical coherence tomography.

OBJECTIVE: To report normal macular thickness measurements in healthy eyes using the latest commercially available optical coherence tomography (OCT) mapping software, version 3.0, from the Stratus OCT (OCT3). METHODS: Thirty-seven eyes from 37 healthy subjects underwent a complete ophthalmologic examination, including OCT. Six radial scans, 6 mm in length and centered on the fovea, were obtained using the OCT3. Retinal thickness was automatically calculated by OCT mapping software. Measurements were displayed as the mean and standard deviation for each of the 9 regions defined in the Early Treatment Diabetic Retinopathy Study. RESULTS: Foveal thickness (mean thickness in the central 1000-microm diameter area) and central foveal thickness (mean thickness at the point of intersection of 6 radial scans) on the OCT3 were 212 +/- 20 and 182 +/- 23 microm, respectively. Macular thickness measurements were thinnest at the center of the fovea, thickest within 3-mm diameter of the center, and diminished toward the periphery of the macula. The temporal quadrant was thinner than the nasal quadrant. Central foveal thickness was also manually determined as 170 +/- 18 microm, approximately 12 microm less than the value automatically obtained from the OCT3 software. There was no correlation between age and foveal thickness (P = .80). CONCLUSIONS: Mean foveal thickness measurements were 38 to 62 microm thicker than previously reported values, while mean central foveal thickness measurements were 20 to 49 microm thicker than previously published values. This discrepancy should be considered when interpreting OCT scans.

Adult↗

Ultrahigh-resolution optical coherence tomography of surgically closed macular holes.

OBJECTIVE: To evaluate retinal anatomy using ultrahigh-resolution optical coherence tomography (OCT) in eyes after successful surgical repair of full-thickness macular hole. METHODS: Twenty-two eyes of 22 patients were diagnosed as having macular hole, underwent pars plana vitrectomy, and had flat/closed macular anatomy after surgery, as confirmed with biomicroscopic and OCT examination findings. An ultrahigh-resolution-OCT system developed for retinal imaging, with the capability to achieve approximately 3-microm axial resolution, was used to evaluate retinal anatomy after hole repair. RESULTS: Despite successful closure of the macular hole, all 22 eyes had macular abnormalities on ultrahigh-resolution-OCT images after surgery. These abnormalities were separated into the following 5 categories: (1) outer foveal defects in 14 eyes (64%), (2) persistent foveal detachment in 4 (18%), (3) moderately reflective foveal lesions in 12 (55%), (4) epiretinal membranes in 14 (64%), and (5) nerve fiber layer defects in 3 (14%). CONCLUSIONS: With improved visualization of fine retinal architectural features, ultrahigh-resolution OCT can visualize persistent retinal abnormalities despite anatomically successful macular hole surgery. Outer foveal hyporeflective disruptions of the junction between the inner and outer segments of the photoreceptors likely represent areas of foveal photoreceptor degeneration. Moderately reflective lesions likely represent glial cell proliferation at the site of hole reapproximation. Thin epiretinal membranes do not seem to decrease visual acuity and may play a role in reestablishing foveal anatomy after surgery.

Aged↗

Persistence of Cloquet's canal in normal healthy eyes.

PURPOSE: Optic nerve head (ONH) structural imaging with state-of-the-art, high-speed, ultra-high-resolution optical coherence tomography (hsUHR-OCT). DESIGN: Observational cohort study. METHODS: ONH centered 3-dimensional (94,371,840 voxel measurements in a 6- x 6- x 1.4-mm tissue volume) hsUHR-OCT data were obtained in one eye from each of six males and nine females normal healthy volunteers (40 +/- 9 years of age). The presence of structures projecting anteriorly from the disk into the vitreous was noted. RESULTS: Structures were noted in 14 of 15 (93%) examined eyes, emanating from the rim of the ONH at the nasal inferior sector, presenting as thin tissue meandering into the vitreous. CONCLUSIONS: Previous technologies provided limited visualization of ONH structures. The ability to scan the entire disk using 3-dimensional OCT (3D-OCT) in a high-density raster pattern reveals a high frequency of persistence of Cloquet's canal in the normal healthy eye.

Adult↗

Trypan blue-assisted neodymium:YAG laser treatment for overfiltering bleb.

Overfiltering blebs can lead to postoperative problems including hypotony maculopathy, decreased vision, and increased ocular discomfort. Many methods have been used in the past with varying results. Various lasers have been used in an attempt to cause localized scarring and fibrosis. We report a treatment technique to noninvasively treat a patient with an overfiltering bleb using trypan blue and a frequency-doubled continuous-wave neodymium:YAG laser emitting green light.

Aged↗

Redefining lamellar holes and the vitreomacular interface: an ultrahigh-resolution optical coherence tomography study.

OBJECTIVES: To define optical coherence tomographic (OCT) criteria for the diagnosis of a lamellar macular hole, and to increase understanding of lamellar hole pathogenesis by examining fine anatomic features using ultrahigh-resolution optical coherence tomography (UHR OCT). DESIGN: Retrospective observational case series. PARTICIPANTS: Nineteen eyes of 18 patients with lamellar holes were imaged with UHR OCT between 2002 and 2004. METHODS: A UHR OCT system was developed for use in the ophthalmology clinic. All 6 UHR OCT images for each eye imaged were examined. Lamellar holes were diagnosed based on a characteristic OCT appearance. Criteria for the OCT diagnosis of a lamellar hole were as follows: (1) irregular foveal contour; (2) break in the inner fovea; (3) intraretinal split; and (4) intact foveal photoreceptors. From 1205 eyes of 664 patients imaged with UHR OCT, and retrospectively reviewed, 19 eyes of 18 patients were diagnosed with a lamellar hole based on these criteria. All 19 eyes were also imaged with standard resolution OCT. Their charts were retrospectively reviewed. MAIN OUTCOME MEASURES: Standard and ultrahigh-resolution OCT images. RESULTS: On chart review, clinical diagnosis of a lamellar hole was made in only 7 of 19 eyes (37%). Twelve of 19 eyes (63%) had an epiretinal membrane (ERM) on clinical examination. Ten of 19 eyes (53%) had a posterior vitreous detachment. On UHR OCT, 17 of 19 eyes (89%) had ERMs. Eleven ERMs had an unusual thick appearance on UHR OCT. Due to poor visual acuity, 4 eyes underwent vitrectomy. Only 1 of 4 surgeries (25%) was visually and anatomically successful. Another eye improved visually, but a lamellar hole persisted. One eye progressed to a full-thickness macular hole preoperatively, which reopened after surgery. One eye developed a full-thickness hole postoperatively. CONCLUSIONS: The diagnosis of a lamellar hole can be made based on OCT criteria, which could be applied to both standard and ultrahigh-resolution OCT. The increased resolution of UHR OCT sheds light on the pathogenesis of the lamellar hole. Epiretinal membranes were visualized on UHR OCT in the majority of eyes. Many ERMs had an unusual thick appearance on UHR OCT, which may represent either trapped vitreous or posterior hyaloid, and may help stabilize retinal anatomy. Conversely, ERM contraction may play a role in lamellar hole formation. Vitrectomy surgery was anatomically and visually successful in only 1 of 4 patients, suggesting caution when performing vitrectomy on lamellar holes.

Aged↗

Ultrahigh-resolution optical coherence tomography in patients with decreased visual acuity after retinal detachment repair.

OBJECTIVE: To assess microstructural changes in the retina that may explain incomplete visual recovery after anatomically successful repair of rhegmatogenous retinal detachments (RD) using ultrahigh-resolution optical coherence tomography (UHR OCT). DESIGN: Retrospective observational case series. PARTICIPANTS: Seventeen patients with decreased visual acuity after RD repair. Twelve patients had macula-involving and 5 had macula-sparing RDs. METHODS: The UHR OCT prototype capable of approximately 3 mum axial resolution was developed for clinical use. The UHR OCT images through the center of the fovea in 17 patients with visual complaints after RD surgery were obtained. Patients were either postoperative patients from the New England Eye Center or tertiary referrals. Baseline visual acuity, preoperative lens status, location of retinal detachment, macular involvement, and postoperative visual acuity were recorded. MAIN OUTCOME MEASURES: The UHR OCT images after RD repair. RESULTS: The UHR OCT images were obtained 1 to 84 months (median, 5 months) postoperatively. The mean preoperative logarithm of the minimum angle of resolution (logMAR) visual acuity was 1.37 (Snellen equivalent, 20/390). The mean postoperative logMAR visual acuity was 0.48 (Snellen equivalent, 20/60). Anatomical abnormalities that were detected included distortion of the photoreceptor inner/outer segments (IS/OS) junction in 14 of 17 patients (82%), epiretinal membranes in 10 of 17 patients (59%), residual subretinal fluid in 3 of 17 patients (18%), and cystoid macular edema in 2 of 17 patients (12%). Of the 5 patients with preoperative macula-on detachments, 4 had distortion of the outer retina after RD repair. CONCLUSIONS: The higher resolution of UHR OCT facilitates imaging of the IS/OS junction. Therefore, UHR OCT is able to confirm prior histopathologic findings that damage to photoreceptor outer segments may occur as a consequence of retinal detachment. This may explain poor postoperative visual acuity in eyes with anatomically successful repair.

Adult↗

Effect of corneal drying on optical coherence tomography.

PURPOSE: To determine the effect of corneal drying on the outcome of optical coherence tomography (OCT). DESIGN: Cohort study. PARTICIPANTS: Seventeen normal participants (mean age, 39+/-12 years). METHODS: Subjects underwent a series of peripapillary circular StratusOCT scans (version 3.0; Carl Zeiss Meditec, Inc., Dublin, CA) in a randomly selected eye. Baseline scan sets were acquired, and thereafter, blinking was prevented by taping the eyelid. Eyelid taping was immediately followed by 6 to 8 serial scan sets, each separated by 20 seconds. After removing the eyelid tape, 3 additional scans were acquired at 1, 2, and 4 minutes of blinking freely. MAIN OUTCOME MEASURES: The analyzed outcome measures were scan quality as defined by signal-to-noise ratio (SNR) and signal strength (SS) provided by the built-in OCT software and mean nerve fiber layer (NFL) thickness. RESULTS: Significant reductions in SNR, SS, and NFL were noted at each scanning point in the drying phase (for each, P<0.015, paired t test) except for NFL thickness measurements acquired at 140 and 160 seconds. The reduction in NFL thickness exceeded the 95% confidence limit of the reported reproducibility error of StratusOCT after 15 seconds of corneal drying. After 1 and 2 minutes of blinking freely, there was still a significant reduction in NFL thickness compared with the baseline value, which was no longer evident at the 4-minute scan. CONCLUSIONS: Corneal dryness affects OCT scan quality and measured NFL thickness after a short exposure time. It is recommended to instruct those who are scanned to blink frequently or to instill artificial tears.

Adult↗

High-definition and 3-dimensional imaging of macular pathologies with high-speed ultrahigh-resolution optical coherence tomography.

OBJECTIVE: To assess high-speed ultrahigh-resolution optical coherence tomography (OCT) image resolution, acquisition speed, image quality, and retinal coverage for the visualization of macular pathologies. DESIGN: Retrospective cross-sectional study. PARTICIPANTS: Five hundred eighty-eight eyes of 327 patients with various macular pathologies. METHODS: High-speed ultrahigh-resolution OCT images were obtained in 588 eyes of 327 patients with selected macular diseases. Ultrahigh-resolution OCT using Fourier/spectral domain detection achieves approximately 3-mum axial image resolutions, acquisition speeds of approximately 25 000 axial scans per second, and >3 times finer resolution and >50 times higher speed than standard OCT. Three scan protocols were investigated. The first acquires a small number of high-definition images through the fovea. The second acquires a raster series of high-transverse pixel density images. The third acquires 3-dimensional OCT data using a dense raster pattern. Three-dimensional OCT can generate OCT fundus images that enable precise registration of OCT images with the fundus. Using the OCT fundus images, OCT results were correlated with standard ophthalmoscopic examination techniques. MAIN OUTCOME MEASURES: High-definition macular pathologies. RESULTS: Macular holes, age-related macular degeneration, epiretinal membranes, diabetic retinopathy, retinal dystrophies, central serous chorioretinopathy, and other pathologies were imaged and correlated with ophthalmic examination, standard OCT, fundus photography, and fluorescein angiography, where applicable. High-speed ultrahigh-resolution OCT generates images of retinal pathologies with improved quality, more comprehensive retinal coverage, and more precise registration than standard OCT. The speed preserves retinal topography, thus enabling the visualization of subtle changes associated with disease. High-definition high-transverse pixel density OCT images improve visualization of photoreceptor and pigment epithelial morphology, as well as thin intraretinal and epiretinal structures. Three-dimensional OCT enables comprehensive retinal coverage, reduces sampling errors, and enables assessment of 3-dimensional pathology. CONCLUSIONS: High-definition 3-dimensional imaging using high-speed ultrahigh-resolution OCT improves image quality, retinal coverage, and registration. This new technology has the potential to become a useful tool for elucidating disease pathogenesis and improving disease diagnosis and management.

Adult↗

Detection of differentially expressed glycogenes in trabecular meshwork of eyes with primary open-angle glaucoma.

PURPOSE: To identify differentially expressed glycogenes in trabecular meshwork (TM) of eyes with primary open-angle glaucoma (POAG). METHODS: Total RNA was isolated from TM of cadaveric eyes derived from donors with diagnosed glaucomas of different etiologies and from normal control subjects. RNA was amplified and hybridized to the GLYCOv2 oligonucleotide microarray that contains probes for carbohydrate-binding proteins, glycosyltransferases, and other genes involved in the regulation of glycosylation. Statistical analysis was used to identify differentially expressed genes between normal and POAG samples. RESULTS: This study revealed that POAG TM and normal TM have distinct gene expression profiles. Of the 2001 genes on the array, 19 genes showed differential expression of greater than 1.4-fold in POAG. Mimecan and activinA, which have been shown to be upregulated in models of glaucoma, were both found to be elevated in POAG TM. Many genes were identified for the first time to be differentially regulated in POAG. Among the upregulated genes were: (1) cell adhesion molecules including platelet endothelial cell adhesion molecule-1 and P-selectin, both of which are targets of NFkappaB, which has been shown to be activated in glaucomatous TM; (2) lumican, a core protein of keratan sulfate proteoglycans; and (3) the receptor for IL6, a cytokine that has been shown to be upregulated in TM in response to elevated intraocular pressure. Among the downregulated genes were chondroitin-4-O-sulfotransferase involved in the synthesis of chondroitin sulfate chains and the receptor for PDGFbeta, a growth factor that has been shown to stimulate both TM cell proliferation and phagocytic activity. Results for several genes were confirmed by RTq-PCR. CONCLUSIONS: Microarray technology was used to show, for the first time, that POAG TM has a distinct glycogene expression profile. Differentially expressed glycogenes identified in this study have not been previously investigated for their role in the pathogenesis of POAG and thus are novel factors for further study of the mechanism of the disease and for their possible use as diagnostic markers.

Aged↗