Search PubMed⌕ Search

Biomedical subjects

Joel P Golden

Publications and source records attributed to Joel P Golden.

11 recordsLinked to original sources

Target delivery in a microfluidic immunosensor.

A study is presented that examines the effect of microfluidic mixing elements on direct and sandwich assays performed in microchannels. Patterned grooves were embossed in the top of microchannels made in PDMS using soft lithography. The grooves redirected the fluid flowing in the channel, enhancing delivery of the target from the bulk fluid to the surface and preventing the formation of a depletion layer at the surface. Comparing assays in grooved and plain channels demonstrated that the mixers improved assay results by 26-46%. A computational flow analysis showed that the grooves caused virtual particles in the bulk flow to come close to the surface ( approximately 11 microm) which is consistent with the signal increase seen experimentally. Direct assays for several concentrations of CY5-labeled biotin were performed in the microchannels. The mixers also improved signal intensity in sandwich assays for botulinum toxin which required mixing of the reagents as well as the direction of the target to the surface.

Biosensing Techniques↗

The array biosensor: portable, automated systems.

With recent advances in surface chemistry, microfluidics, and data analysis, there are ever increasing reports of array-based methods for detecting and quantifying multiple targets. However, only a few systems have been described that require minimal preparation of complex samples and possess a means of quantitatively assessing matrix effects. The NRL Array Biosensor has been developed with the goal of rapid and sensitive detection of multiple targets from multiple samples analyzed simultaneously. A key characteristic of this system is its two-dimensional configuration, which allows controls and standards to be analyzed in parallel with unknowns. Although the majority of our work has focused on instrument automation and immunoassay development, we have recently initiated efforts to utilize alternative recognition molecules, such as peptides and sugars, for detection of a wider variety of targets. The array biosensor has demonstrated utility for a variety of applications, including food safety, disease diagnosis, monitoring immune response, and homeland security, and is presently being transitioned to the commercial sector for manufacturing.

Automation↗

Toolbox for the design of optimized microfluidic components.

A computational "toolbox" for the a priori design of optimized microfluidic components is presented. These components consist of a microchannel under low-Reynolds number, pressure-driven flow, with an arrangement of grooves cut into the top and bottom to generate a tailored cross-channel flow. An advection map for each feature (i.e., groove of a particular shape and orientation) predicts the lateral transport of fluid within the channel due to that feature. We show that applying these maps in sequence generates an excellent representation of the outflow distribution for complex designs that combine these basic features. The effect of the complex three-dimensional flow field can therefore be predicted without solving the governing flow equations through the composite geometry, and the resulting distribution of fluids in the channel is used to evaluate how well a component performs a specified task. The generation and use of advection maps is described, and the toolbox is applied to determine optimal combinations of features for specified mixer sizes and mixing metrics.

Microfluidic Analytical Techniques↗

A microfluidic mixer with grooves placed on the top and bottom of the channel.

A new microfluidic mixer is presented consisting of a rectangular channel with grooves placed in the top and bottom. This not only increases the driving force behind the lateral flow, but allows for the formation of advection patterns that cannot be created with structures on the bottom alone. Chevrons, pointing in opposite directions on the top and bottom, are used to create a pair of vortices positioned side by side. Stripes running the width of the channel generate a pair of vertically stacked vortices. Computational fluid dynamics (CFD) simulations are used to model the behavior of the systems and provide velocity maps at cross-sections within the mixer. Experiments demonstrate the mixing that results when two segregated species enter the mixer side-by-side and pass through two cycles of the mixer (i.e., two alternating sets of four stripes and four chevrons).

Computer Simulation↗

Design and evaluation of a Dean vortex-based micromixer.

A mixer, based on the Dean vortex, is fabricated and tested in an on-chip format. When fluid is directed around a curve under pressure driven flow, the high velocity streams in the center of the channel experience a greater centripetal force and so are deflected outward. This creates a pair of counter-rotating vortices moving fluid toward the inner wall at the top and bottom of the channel and toward the outer wall in the center. For the geometries studied, the vortices were first seen at Reynolds numbers between 1 and 10 and became stronger as the flow velocity is increased. Vortex formation was monitored in channels with depth/width ratios of 0.5, 1.0, and 2.0. The lowest aspect ratio strongly suppressed vortex formation. Increasing the aspect ratio above 1 appeared to provide improved mixing. This design has the advantages of easy fabrication and low surface area.

Centrifugation↗

Surface-immobilized self-assembled protein-based quantum dot nanoassemblies.

Luminescent semiconductor quantum dot (QD)-based optical biosensors have the potential to overcome many of the limitations associated with using conventional organic dyes for biodetection. We have previously demonstrated a hybrid QD-protein-based fluorescence resonance energy transfer (FRET) sensor. Although the QD acted as an energy donor and a protein scaffold in the sensor, recognition and specificity were derived from the proteins. Transitioning this hybrid prototype sensor into flow cells and integrated devices will require a surface-immobilization strategy that allows the QD-based sensor to sample the environment and still maintain a distinct protein-covered QD architecture. We demonstrate a self-assembled strategy designed to accomplish this. Using glass slides coated with a monolayer of neutravidin (NA) as the template, QDs with maltose binding protein (MBP) and avidin coordinated to their surface were attached to the glass slides in discrete patterns using an intermediary bridge of biotinylated MBP or antibody linkers. Control of the surface location and concentration of the QD-protein-based structures is demonstrated. The utility of this self-assembly strategy is further demonstrated by assembling a QD-protein structure that allows the QDs to engage in FRET with a dye located on the surface-covering protein.

Avidin↗

Array biosensor for detection of toxins.

The array biosensor is capable of detecting multiple targets rapidly and simultaneously on the surface of a single waveguide. Sandwich and competitive fluoroimmunoassays have been developed to detect high and low molecular weight toxins, respectively, in complex samples. Recognition molecules (usually antibodies) were first immobilized in specific locations on the waveguide and the resultant patterned array was used to interrogate up to 12 different samples for the presence of multiple different analytes. Upon binding of a fluorescent analyte or fluorescent immunocomplex, the pattern of fluorescent spots was detected using a CCD camera. Automated image analysis was used to determine a mean fluorescence value for each assay spot and to subtract the local background signal. The location of the spot and its mean fluorescence value were used to determine the toxin identity and concentration. Toxins were measured in clinical fluids, environmental samples and foods, with minimal sample preparation. Results are shown for rapid analyses of staphylococcal enterotoxin B, ricin, cholera toxin, botulinum toxoids, trinitrotoluene, and the mycotoxin fumonisin. Toxins were detected at levels as low as 0.5 ng mL(-1).

Biosensing Techniques↗

Integrating waveguide biosensor.

A capillary biosensor is demonstrated which uses the waveguiding properties of the capillary to integrate the signal over an increased surface area without simultaneously increasing the background noise from the detector. This biosensor achieves limits of detection of 30-50 pg/mL in immunoassays using a diode laser for excitation and a PMT for detection. This is approximately 2 orders of magnitude greater sensitivity than was achieved using the same immunoassay reagents in a fiber optic biosensor or a planar array biosensor. Two different approaches to using the capillaries as immunosensors are described, either of which could be adapted for multianalyte sensing.

Animals↗

Attachment of plastic fluidic components to glass sensing surfaces.

Two types of flow manifolds have been developed in order to provide a reliable method for attaching plastic microfluidic systems to glass sensing surfaces. A permanently mounted flow manifold has grooves in the inter-channel barriers to confine the epoxy used for attachment. The reusable flow manifold has inter-channel barriers composed of both plexiglass for rigidity and polydimethysiloxane for leak-free attachment.

Biosensing Techniques↗

Voltage-induced inhibition of antigen-antibody binding at conducting optical waveguides.

Optical waveguides coated with electrically conducting indium-tin oxide (ITO) are demonstrated here as a new class of substrate for fluorescent immunosensors. These waveguides combine electrochemical control with evanescent excitation and image-based detection. Presented here are preliminary results utilizing these waveguides that demonstrate influence of waveguide voltage on antigen binding. Specifically, waveguide surfaces were bisected into electrically addressable halves, anti-ovalbumin immobilized in patterns on their surfaces, and a 1.3 V bias applied between waveguide halves in the presence of Cy5-labeled ovalbumin in 10 mM phosphate buffer (pH 7.4) containing 150 mM NaCl and 0.05% Tween-20. Fluorescence imaging indicated that binding of the antigen to positively biased waveguide halves was inhibited nearly 10-fold compared with negatively biased waveguide halves and unbiased controls. Furthermore, it is shown that ovalbumin binding to positively biased waveguide regions is regenerated after removal of applied voltage. These results suggest that electrochemical control of immunosensor substrates can be used as a possible strategy toward minimizing cross-reactive binding and/or nonspecific adsorption, immunosensor regeneration, and controlled binding.

Animals↗

A comparison of imaging methods for use in an array biosensor.

An array biosensor has been developed which uses an actively-cooled, charge-coupled device (CCD) imager. In an effort to save money and space, a complementary metal-oxide semiconductor (CMOS) camera and photodiode were tested as replacements for the cooled CCD imager. Different concentrations of CY5 fluorescent dye in glycerol were imaged using the three different detection systems with the same imaging optics. Signal discrimination above noise was compared for each of the three systems.

Biosensing Techniques↗