Jinsong Ouyang

Publications and source records attributed to Jinsong Ouyang.

2 recordsLinked to original sources

Performance of a novel collimator for high-sensitivity brain SPECT.

We assessed improvements in performance in detection and estimation tasks due to a novel brain single photon computed tomography collimator. Data were acquired on the CeraSPECT scanner using both new and standard collimators. The new variable focusing collimator SensOgrade samples the projections unequally, with central regions more heavily represented, to compensate for attenuation of counts from central brain structures. Furthermore, it utilizes more of the cylindrical crystal surface. Two phantom studies were performed. The first phantom was a 21-cm-diameter cylindrical background containing nine spheres ranging from 0.5 to 5 cm3 in volume. 99mTc sphere to background activity ratio was 10:1. Twenty-nine 10-min datasets were acquired with each collimator. The second phantom was the Radiology Support Devices (Long Beach, CA) striatal phantom with striatal-background ratios of 10:1 on the left and 5:1 on the right. Twenty-nine 4-min datasets were acquired with each collimator. Perfusion imaging using 99mTc-HMPAO was also performed in three healthy volunteers using both collimators under identical simulations. Projections were reconstructed by filtered backprojection with an unwindowed ramp filter. The nonprewhitening matched filter signal-to-noise ratio (NPW-SNR) was computed as a surrogate for human performance in detecting spherical lesions. Sphere activity concentration, radius, and location coordinates were simultaneously estimated by fitting images to an assumed model using an iterative nonlinear algorithm. Resolution recovery was implicit in the estimation procedure, as the point spread function was incorporated into the model. NPW-SNR for sphere detection was 1.5 to 2 times greater with the new collimator; for the striatal phantom the improvement in SNR was 54%. The SNR for estimating sphere activity concentration improved by 46 to 89% for spheres located more than 5 cm from the phantom center. Images acquired with the standard collimator were too noisy in the central regions to allow estimation of sphere activity. In 99mTc-HMPAO human studies, SNR was improved by 21 to 41% in the cortex, 66% in the basal ganglia, and 74% in the thalamus. The new collimator leads to substantially improved detection and estimation performance throughout the brain. The higher sensitivity will be particularly important for dynamic imaging.

Brain↗

Generalized five-dimensional dynamic and spectral factor analysis.

We have generalized the spectral factor analysis and the factor analysis of dynamic sequences (FADS) in SPECT imaging to a five-dimensional general factor analysis model (5D-GFA), where the five dimensions are the three spatial dimensions, photon energy, and time. The generalized model yields a significant advantage in terms of the ratio of the number of equations to that of unknowns in the factor analysis problem in dynamic SPECT studies. We solved the 5D model using a least-squares approach. In addition to the traditional non-negativity constraints, we constrained the solution using a priori knowledge of both time and energy, assuming that primary factors (spectra) are Gaussian-shaped with full-width at half-maximum equal to gamma camera energy resolution. 5D-GFA was validated in a simultaneous pre-/post-synaptic dual isotope dynamic phantom study where 99mTc and 123I activities were used to model early Parkinson disease studies. 5D-GFA was also applied to simultaneous perfusion/dopamine transporter (DAT) dynamic SPECT in rhesus monkeys. In the striatal phantom, 5D-GFA yielded significantly more accurate and precise estimates of both primary 99mTc (bias=6.4 % +/- 4.3 %) and 1231 (-1.7% +/- 6.9%) time activity curves (TAC) compared to conventional FADS (biases = 15.5% +/- 10.6% in 99mTc and 8.3% +/- 12.7% in 123I, p < 0.05). Our technique was also validated in two primate dynamic dual isotope perfusion/DAT transporter studies. Biases of 99mTc-HMPAO and 123I-DAT activity estimates with respect to estimates obtained in the presence of only one radionuclide (sequential imaging) were significantly lower with 5D-GFA (9.4% +/- 4.3% for 99mTc-HMPAO and 8.7% +/-4.1% for 123I-DAT) compared to biases greater than 15% for volumes of interest (VOI) over the reconstructed volumes (p < 0.05). 5D-GFA is a novel and promising approach in dynamic SPECT imaging that can also be used in other modalities. It allows accurate and precise dynamic analysis while compensating for Compton scatter and cross-talk.

Algorithms↗