Search PubMed⌕ Search

Biomedical subjects

Jianzhong Li

Publications and source records attributed to Jianzhong Li.

17 recordsLinked to original sources

Intestinal organoid screen reveals that Bacillus velezensis PGM541 promotes epithelial proliferation via its metabolite butyric acid.

BACKGROUND: Probiotics have been widely used for the regulation of intestinal health. Current screening methods for probiotics typically rely on animal or two-dimensional cell models. In this study, we employed intestinal organoids to identify a candidate probiotic strain. Furthermore, we investigated the potential mechanisms through which this strain and its active metabolites exert their effects, thereby evaluating the efficacy of this screening approach. RESULTS: Firstly, candidate probiotic strain PGM541 was identified from a porcine-derived Bacillus library by assessing organoid viability. Subsequently, to validate the organoid screening reliability, the potential mechanism of strain PGM541 on the intestinal epithelium was investigated; it was found to exhibit probiotic functions by regulating cell proliferation in both in vitro organoid and in vivo piglet models. Furthermore, organoid screening combined with metabolomic analysis identified butyric acid (BA) as the key bioactive metabolite responsible for driving epithelial proliferation. Whole-genome and transcriptomic analyses revealed the biosynthetic pathway of BA in strain PGM541. Importantly, BA receptor blockade experiments directly confirmed that BA enhances epithelial proliferation via interaction with the FFAR2 receptor, thereby validating its functional activity. Additionally, strain PGM541 exhibited protective effects against dextran sulfate sodium (DSS)-induced colitis, further validating the effectiveness of the intestinal organoid platform for probiotic screening. CONCLUSIONS: The probiotic strain PGM541, which was screened using intestinal organoids, promotes intestinal epithelial cell proliferation via its metabolite BA activating the FFAR2 receptor. These findings demonstrate that the intestinal organoid model serves as an effective platform for both preliminary probiotic screening and mechanistic investigation. Video Abstract.

Animals↗

The impact of sample imbalance on identifying differentially expressed genes.

BACKGROUND: Recently several statistical methods have been proposed to identify genes with differential expression between two conditions. However, very few studies consider the problem of sample imbalance and there is no study to investigate the impact of sample imbalance on identifying differential expression genes. In addition, it is not clear which method is more suitable for the unbalanced data. RESULTS: Based on random sampling, two evaluation models are proposed to investigate the impact of sample imbalance on identifying differential expression genes. Using the proposed evaluation models, the performances of six famous methods are compared on the unbalanced data. The experimental results indicate that the sample imbalance has a great influence on selecting differential expression genes. Furthermore, different methods have very different performances on the unbalanced data. Among the six methods, the welch t-test appears to perform best when the size of samples in the large variance group is larger than that in the small one, while the Regularized t-test and SAM outperform others on the unbalanced data in other cases. CONCLUSION: Two proposed evaluation models are effective and sample imbalance should be taken into account in microarray experiment design and gene expression data analysis. The results and two proposed evaluation models can provide some help in selecting suitable method to process the unbalanced data.

Algorithms↗

Measurement of ammonia in human breath with a liquid-film conductivity sensor.

Measurement of breath NH3 is of interest in clinical applications as it can be used as a measure of kidney/liver functions as well as halitosis. We have developed a liquid-film conductivity sensor to measure NH3 in human breath. A film of dilute H2SO4 is formed on the top of two metal capillary tubes placed in a concentric annular arrangement. The tube exterior has been specially treated to render it hydrophilic. As breath passes over the sensor tip, the film collects NH3 and the solution conductivity (measured by the concentric capillaries functioning as electrodes) decreases accordingly. This initial rate of conductivity decrease was determined to be the best metric (most rapid and least dependent on breath pCO2) for ammonia, relative to time to attain complete neutralization (conductivity minimum) or the final rate of conductivity increase as more ammonia dissolves after neutralization. The absorbing solution composition was optimized so that CO2 does not interfere. Both dynamic measurement using mask sampling and offline balloon sampling were performed. Ammonia readily absorbs on surfaces when significant concentrations of water vapor are present. As such, memory effects are common when analyzing human breath for ammonia. This problem was successfully eliminated. The results from this sensor agreed well with data obtained by a solution-phase fluorometric technique using a porous membrane diffusion scrubber and o-phthalaldehyde derivatization chemistry. For breath CO2 measurement, the applicability of a similar sensor that relies on a NaOH film was also demonstrated.

Ammonia↗

The zinc finger transcription factor 191 is required for early embryonic development and cell proliferation.

Human zinc finger protein 191 (ZNF191/ZNF24) was cloned and characterized as a SCAN family member, which shows 94% identity to its mouse homologue zinc finger protein 191 (Zfp191). ZNF191 can specifically interact with an intronic polymorphic TCAT repeat (HUMTH01) in the tyrosine hydroxylase (TH) gene. Allelic variations of HUMTH01 have been stated to have a quantitative silencing effect on TH gene expression and to correlate with quantitative and qualitative changes in the binding by ZNF191. Zfp191 is widely expressed during embryonic development and in multiple tissues and organs in adult. To investigate the functions of Zfp191 in vivo, we have used homologous recombination to generate mice that are deficient in Zfp191. Heterozygous Zfp191(+/-) mice are normal and fertile. Homozygous Zfp191(-/-) embryos are severely retarded in development and die at approximately 7.5 days post-fertilization. Unexpectedly, in Zfp191(-/-) and Zfp191(+/-) embryos, TH gene expression is not affected. Blastocyst outgrowth experiments and the RNA interference-mediated knockdown of ZNF191 in cultured cells revealed an essential role for Zfp191 in cell proliferation. In further agreement with this function, no viable Zfp191(-/-) cell lines were obtained by derivation of embryonic stem (ES) cells from blastocysts of Zfp191(+/-) intercrosses or by forced homogenotization of heterozygous ES cells at high concentrations of G418. These data show that Zfp191 is indispensable for early embryonic development and cell proliferation.

Animals↗

A stable gene selection in microarray data analysis.

BACKGROUND: Microarray data analysis is notorious for involving a huge number of genes compared to a relatively small number of samples. Gene selection is to detect the most significantly differentially expressed genes under different conditions, and it has been a central research focus. In general, a better gene selection method can improve the performance of classification significantly. One of the difficulties in gene selection is that the numbers of samples under different conditions vary a lot. RESULTS: Two novel gene selection methods are proposed in this paper, which are not affected by the unbalanced sample class sizes and do not assume any explicit statistical model on the gene expression values. They were evaluated on eight publicly available microarray datasets, using leave-one-out cross-validation and 5-fold cross-validation. The performance is measured by the classification accuracies using the top ranked genes based on the training datasets. CONCLUSION: The experimental results showed that the proposed gene selection methods are efficient, effective, and robust in identifying differentially expressed genes. Adopting the existing SVM-based and KNN-based classifiers, the selected genes by our proposed methods in general give more accurate classification results, typically when the sample class sizes in the training dataset are unbalanced.

Algorithms↗

Soap bubbles in analytical chemistry. Conductometric determination of sub-parts per million levels of sulfur dioxide with a soap bubble.

Soap bubbles provide a fascinating tool that is little used analytically. With a very low liquid volume to surface area ratio, a soap bubble can potentially provide a very useful interface for preconcentration where mass transfer to an interfacial surface is important. Here we use an automated system to create bubbles of uniform size and film thickness. We utilize purified Triton-X 100, a nonionic surfactant, to make soap bubbles. We use such bubbles as a gas-sampling interface. Incorporating hydrogen peroxide into the bubble provides a system where electrical conductance increases as the bubble is exposed to low concentrations of sulfur dioxide gas. We theoretically derive the conductance of a hollow conducting spherical thin film with spherical cap electrodes. We measure the film thickness by incorporating a dye in the bubble making solution and laser transmission photometry and find that it agrees well with the geometrically computed thickness. With the conductance of the bubble-making soap solution being measured by conventional methods, we show that the measured values of the bubble conductance with known bubble and electrode dimensions closely correspond to the theoretically computed value. Finally, we demonstrate that sub-ppm levels of SO(2) can readily be detected by the conductivity change of a hydrogen peroxide-doped soap bubble, measured in situ, when the gas flows around the bubble.

Journal Article↗

Hybrid fluorometric flow analyzer for ammonia.

We describe a robust, highly sensitive instrument for the determination of ambient ammonia. The instrument uses two syringe pumps to handle three liquids. The flow configuration is a hybrid between traditional flow injection (FI) and sequential injection (SI) schemes. This hybrid flow analyzer spends approximately 87% of its time in the continuous flow FI mode, providing the traditional FI advantages of high baseline stability and sensitivity. The SI fluid handling operation in the remaining time makes for flexibility and robustness. Atmospheric ammonia is collected in deionized water by a porous membrane diffusion scrubber at 0.2 L/min with quantitative collection efficiency, derivatized on-line to 1-sulfonatoisoindole, and measured by fluorometry. In the typical range for ambient ammonia (0-20 ppbv), response is linear (r2 = 0.9990) with a S/N = 3 limit of detection of 135 pptv (15 nM for 500 microL of injected NH4+(aq)) with an inexpensive light emitting diode photodiode-based detector. Automated operation in continuously repeated, 8-min cycles over 9 days shows excellent overall precision (n = 1544 p(NH)3 = 5 ppbv, RSD = 3%). Precision for liquid-phase injections is even better (n = 1520, [NH4+(aq)] = 2.5 microM, RSD = 2%). The response decreases by 3.6% from 20 to 80% relative humidity.

Ammonia↗

Summertime ambient formaldehyde in five U.S. metropolitan areas: Nashville, Atlanta, Houston, Philadelphia, and Tampa.

First, we briefly review the atmospheric chemistry and previous intercomparison measurements for HCHO, with special reference to the diffusion scrubber Hantzsch reaction based fluorescence instrument used in the field studies reported herein. Then we discuss summertime HCHO levels in five major U.S. cities measured over 1999-2002, primarily from ground-based measurements. Land-sea breeze circulations play a major role in observed concentrations in coastal cities. Very high HCHO peak mixing ratios were observed in Houston (>47 ppb) where the overall median mixing ratio was 3.3 ppb; the corresponding values in Atlanta were approximately >18 and 7.9 ppb, respectively. The peak and median mixing ratios (9.3 and 2.3 ppb) were the lowest for Tampa, where the land-sea breeze also played an important role. In several cities, replicate HCHO measurements were made by direct spectroscopic instruments; the instruments were located kilometers from each other and addressed very different heights (e.g., 106 vs 10 m). Even under these conditions, there was remarkable qualitative and often quantitative agreement between the different instruments, when they were all sampling the same air mass within a short period of each other. Local chemistry dominates how HCHO is formed and dissipated. The high concentrations in Houston resulted from emissions near the ship channel; the same formaldehyde plume was measured at two sites and clearly ranged over tens of kilometers. Local micrometeorology is another factor. HCHO patterns measured at a high-rise site in downtown Nashville were very much in synchrony with other ground sites 12 km away until July 4 celebrations whence HCHO concentrations at the downtown site remained elevated for several days and nights. The formation and dissipation of HCHO in the different cities are discussed in terms of other concurrently measured species and meteorological vectors. The vertical profiles of HCHO in and around Tampa under several different atmospheric conditions are presented. The extensive data set represented in this paper underscores that urban HCHO measurements can now be made easily; the agreement between disparate instruments (that are independently calibrated or rely on the absolute absorption cross section) further indicates that such measurements can be done reliably and accurately for this very important atmospheric species. The data set presented here can be used as a benchmark for future measurements if the use of formaldehyde precursors such as methanol or methyl tert-butyl ether (MTBE) as oxygenated fuel additives increases in the future.

Air Pollutants↗

Induced transparency by intersubband plasmon coupling in a quantum well.

We study coupling of two intersubband plasmons associated with dipole-allowed cascading transitions in a quantum well. We show that the coupling can lead to the disappearance of the lower-energy resonance accompanied by an anticrossing behavior. Such coupling induced anomalies are of collective and resonant nature and provide the first example of Coulomb interaction induced transparency. Our numerical results from a microscopic theory are confirmed by an analytical model.

Journal Article↗

Membrane-based parallel plate denuder for the collection and removal of soluble atmospheric gases.

A continuously wetted cellulose acetate membrane-based parallel plate diffusion denuder is described. This is the first membrane-based denuder that has a small enough internal liquid holdup volume to permit reasonably rapid response time (10 --> 90% rise time of approximately 1.2 min for a transient event at a liquid flow rate of 500 microL/min) while permitting quantitative removal of common soluble atmospheric trace gases at flow rates up to 1.7 L/min. The latter attribute permits the use of the device as the first element in a particle sampling and analysis system for the quantitative removal of potentially interfering soluble trace gases. Particle losses in the denuder range from 0.9 to 2.9% over an aerodynamic diameter range of 0.38-3.48 microm, averaging 1.8%. However, only approximately 0.5% of the particles actually appears in the denuder effluent liquid. The relatively compact (300 mm H x 57 mm W x 26 mm D) wet denuder should be attractive in a number of applications. We show excellent agreement for HONO measurements with a conventional larger parallel plate wetted denuder in field measurements.

Journal Article↗

Silver-induced enhancement of thiochrome-based peroxide measurements.

Thiamine is presently one of the most attractive substrates used for sensitive fluorometric measurements of peroxides. Thiochrome (TC), a highly fluorescent product, is formed in enzyme-mediated oxidations. It is assumed that H(2)O(2) is nearly quantitatively converted to TC. The reaction cannot differentiate H(2)O(2) from many other peroxides such as methylhydroperoxide (MHP); to perform differential measurements, H(2)O(2) can first be selectively destroyed by a suitable catalyst such as MnO(2). In substituting Ag(2)O for MnO(2) to accomplish the selective destruction of H(2)O(2), we achieved the stated objective but were puzzled by a 3-fold increase in the MHP response in the presence of Ag(2)O. It was soon discovered that traces of dissolved Ag(+) and Hg(2+) can dramatically increase the yield of TC in this reaction from either H(2)O(2) or MHP; the normal yield in fact is only 20%. We present here a reaction scheme and kinetic model that adequately describes this behavior and should provide a path to substantially increase the sensitivity of this important assay method.

Flow Injection Analysis↗

Interplay of collective excitations in quantum-well intersubband resonances.

Intersubband resonances in a semiconductor quantum well (QW) display fascinating features involving various collective excitations such as Fermi-edge singularity (FES) and intersubband plasmon (ISP). Using a density matrix approach, we treated many-body effects such as depolarization, vertex correction, and self-energy consistently for a two-subband system. We found a systematic change in resonance spectra from FES- to ISP-dominated features, as QW width or electron density is varied. Such an interplay between FES and ISP significantly changes both line shape and peak position of the absorption spectrum. We found that a cancellation of FES and ISP undresses the resonant responses and recovers the single-particle features of absorption for semiconductors with a strong nonparabolicity such as InAs, leading to a dramatic broadening of the absorption spectrum.

Journal Article↗

Trace gas measurement with an integrated porous tube collector/long-path absorbance detector.

Porous membrane tubes filled with an absorbing solution that change colors upon selective reactions with specific gases provide high sensitivity inexpensive gas sensors. These can be routinely used for ambient monitoring in a fully automated manner. We consider both stopped and continuous flow operations and show the superiority of the stopped flow mode theoretically and experimentally. Light throughput through various membrane tubes is presented, and superior performance of such tubes over Teflon AF is shown. Sensors for NO2 and for O3 were based on Griess-Saltzman and indigotrisulfonate chemistries, respectively. A computer-controlled two-LED absorbance measurement system (one wavelength monitors the signal, the other references the system) that also governs automated reagent refilling was implemented. Sub-parts-per-billion-volume detection limits are attainable within a few minutes for both gases. Comparative data with a commercial UV-photometry-based ozone monitor showed excellent agreement with the response pattern of the present instrument. Low cost, ready applicability to the measurement of different gases by merely changing the light source and chemistry, and high sensitivity makes this instrument attractive for both pedagogic and practical purposes.

Journal Article↗

An energy-efficient self-regulating heater for flow-through applications.

In many experiments, a flow-through heating arrangement is needed to reduce reaction time. Often the reaction conditions require inertness of the wetted material. Heated reactors based on polymeric tubing, notably PTFE, are the most common, and such reactors are typically used in a manner in which they are put in a heated bath or an otherwise thermally conductive potting in which a heater and a temperature sensor are embedded for heating and temperature control. Polymeric tubes are poor conductors of heat; as such, most reactors of this type have very poor energy utilization. We describe here heated flow-through reactors where a wire runs through the entire length of the tubular reactor and where the wire is directly electrically heated. The wire may or may not be electrically insulated. If the exterior of the tube is well insulated, the energy efficiency of such a reactor in heating the fluid of interest is nearly unity. This makes it most suitable for battery-powered applications. If an appropriate wire with a significant temperature coefficient of resistance is chosen, monitoring the current through the device at constant applied voltage indicates the effective mean temperature of the device and thus allows effective temperature control without an additional sensor/controller with essentially instantaneous response. Temperature control within +/- 0.4 degrees C at a mean temperature of 65 degrees C and within +/- 0.9 degrees C at 87 degrees C have been achieved.

Journal Article↗

Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide.

Presently, solid-state sources such as light-emitting diodes (LEDs) provide for intense, nearly monochromatic light. They are available over a broad range of emission wavelengths. Unlike incandescent and discharge lamps, LEDs can be turned on and off at high speeds. The resulting light pulses are highly reproducible. This allows the use of a single photomultiplier tube (PMT), often the most expensive component in a high-sensitivity measurement system, as a multiplexed detector with multiple, fiber-optic-coupled, fluorescence-detection cells excited by solid-state sources. A time resolution of 1 min is adequate in many continuous detection schemes. This enables multiple-channel single-detector multiplexed measurement without any loss of S/N. On the basis of this principle, we describe a new automated continuous instrument for the simultaneous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide (MHP). A Nafion membrane diffusion scrubber (DS) is used with hematin-catalyzed oxidation of thiamine to thiochrome for the measurement of H2O2, and an expanded poly(tetrafluoroethylene) (ePTFE) DS is used with a H2O2 destruction catalyst and horseradish peroxidase-catalyzed oxidation of thiamine to thiochrome for the measurement of MHP. The respective limits of detection are 25 pptv and 15 pptv. Design, performance details, and illustrative results from a field campaign (Philadelphia NEO3PS study, 2001) are presented.

Journal Article↗

Selective measurement of gaseous hydrogen peroxide with light emitting diode-based liquid-core waveguide absorbance detector.

Atmospheric H2O2 is typically determined by enzymatically mediated fluorogenic reactions that do not discriminate between H2O2 and organic peroxides. Reactions of Ti(IV) with H2O2 has also been the basis of colorimetric measurements of H2O2 but is too insensitive. A more sensitive determination is possible with the Ti(IV)-4-(2-pyridylazo)resorcinol (PAR) complex, however, unreacted PAR must be chromatographically separated. A titanium(IV)porphyrin complex, oxo[5,10,15,20-tetra(4-pyridyl)porphyrinato]titanium(IV) [TiO(tpypH4)4+], (TiTPyP) was introduced for the measurement of aqueous H2O2. In this paper, we show that TiTPyP can be used for measuring H2O2(g)), it does not respond to CH3HO2. With a proper membrane collector, practically there is no interference from concurrently present gaseous SO2 and O3. The approach permits a S/N = 3 limit of detection (LOD) of 26 pptv with a 50 mm path liquid core waveguide (LCW) absorbance detector and a light emitting diode based light source. This is adequate for real atmospheric measurements.

Journal Article↗