Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming.

The purpose of this study is to extend an algorithm proposed for beam orientation optimization in classical conformal radiotherapy to intensity-modulated radiation therapy (IMRT) and to evaluate the algorithm's performance in IMRT scenarios. In addition, the effect of the candidate pool of beam orientations, in terms of beam orientation resolution and starting orientation, on the optimized beam configuration, plan quality and optimization time is also explored. The algorithm is based on the technique of mixed integer linear programming in which binary and positive float variables are employed to represent candidates for beam orientation and beamlet weights in beam intensity maps. Both beam orientations and beam intensity maps are simultaneously optimized in the algorithm with a deterministic method. Several different clinical cases were used to test the algorithm and the results show that both target coverage and critical structures sparing were significantly improved for the plans with optimized beam orientations compared to those with equi-spaced beam orientations. The calculation time was less than an hour for the cases with 36 binary variables on a PC with a Pentium IV 2.66 GHz processor. It is also found that decreasing beam orientation resolution to 10 degrees greatly reduced the size of the candidate pool of beam orientations without significant influence on the optimized beam configuration and plan quality, while selecting different starting orientations had large influence. Our study demonstrates that the algorithm can be applied to IMRT scenarios, and better beam orientation configurations can be obtained using this algorithm. Furthermore, the optimization efficiency can be greatly increased through proper selection of beam orientation resolution and starting beam orientation while guaranteeing the optimized beam configurations and plan quality.

Algorithms↗

Simultaneous minimization of leaf travel distance and tongue-and-groove effect for segmental intensity-modulated radiation therapy.

This paper introduces a method to simultaneously minimize the leaf travel distance and the tongue-and-groove effect for IMRT leaf sequences to be delivered in segmental mode. The basic idea is to add a large enough number of openings through cutting or splitting existing openings for those leaf pairs with openings fewer than the number of segments so that all leaf pairs have the same number of openings. The cutting positions are optimally determined with a simulated annealing technique called adaptive simulated annealing. The optimization goal is set to minimize the weighted summation of the leaf travel distance and tongue-and-groove effect. Its performance was evaluated with 19 beams from three clinical cases; one brain, one head-and-neck and one prostate case. The results show that it can reduce the leaf travel distance and (or) tongue-and-groove effect; the reduction of the leaf travel distance reaches its maximum of about 50% when minimized alone; the reduction of the tongue-and-groove reaches its maximum of about 70% when minimized alone. The maximum reduction in the leaf travel distance translates to a 1 to 2 min reduction in treatment delivery time per fraction, depending on leaf speed. If the method is implemented clinically, it could result in significant savings in treatment delivery time, and also result in significant reduction in the wear-and-tear of MLC mechanics.

Algorithms↗

Delivery time comparison for intensity-modulated radiation therapy with/without flattening filter: a planning study.

The treatment delivery time of intensity-modulated radiation therapy (IMRT) with a multileaf collimator (MLC) is generally longer than that of conventional radiotherapy. In theory, removing the flattening filter from the treatment head may reduce the beam-on time by enhancing the output dose rate, and then reduce the treatment delivery time. And in practice, there is a possibility of delivering the required fluence distribution by modulating the unflattened non-uniform fluence distribution. However, the reduction of beam-on time may be discounted by the increase of leaf-travel time and (or) verification-and-recording (V&R) time. Here we investigate the overall effect of flattening filter on the treatment delivery time of IMRT with MLCs implemented in the step and shoot method, as well as with compensators on six hybrid machines. We compared the treatment delivery time with/without flattening filter for ten nasopharynx cases and ten prostate cases by observing the variations of the ratio of the beam-on time, segment number, leaf-travel time and the treatment delivery time with dose rate, leaf speed and V&R time. The results show that, without the flattening filter, the beam-on time reduces for both static MLC and compensator-based techniques: the number of segments and the leaf-travel time increase slightly for the static MLC technique; the relative IMRT treatment delivery time decreases more with lower dose rate, higher leaf speed and shorter V&R overhead time. The absolute treatment delivery time reduction depends on the fraction dose. It is not clinically significant at a fraction dose of 2 Gy for the technique of removing the flattening filter, but becomes significant when the fraction dose is as high as that for radiosurgery.

Algorithms↗

Simultaneous minimizing monitor units and number of segments without leaf end abutment for segmental intensity modulated radiation therapy delivery.

Leaf end abutment is seldom studied when delivering segmental intensity modulated radiation therapy (IMRT) fields. We developed an efficient leaf sequencing method to eliminate leaf end abutment for segmental IMRT delivery. Our method uses simple matrix and sorting operations to obtain a solution that simultaneously minimizes total monitor units and number of segments without leaf end abutment between segments. We implemented and demonstrated our method for multiple clinical cases. We compared the results of our method with the results from exhaustive search method. We found that our solution without leaf end abutment produced equivalent results to the unconstrained solutions in terms of minimum total monitor units and minimum number of leaf segments. We conclude that the leaf end abutment fields can be avoided without affecting the efficiency of segmental IMRT delivery. The major strength of our method is its simplicity and high computing speed. This potentially provides a useful means for generating segmental IMRT fields that require high spatial resolution or complex intensity distributions.

Algorithms↗

The influence of lateral electronic disequilibrium on the radiation treatment planning for lung cancer irradiation.

Using higher energy photons can obtain better target dose uniformity and skin sparing for treating deep lesions, but the effect of lacking lateral scattering in the low-density lung may degrade the target coverage. To analyze the influence of lateral electronic disequilibrium on the radiation treatment planning for lung cancer, three dimension conformal treatment (3D-CRT) plans of using 6 MV and 18 MV X-ray respectively for a lung cancer case have been worked out by using pencil beam algorithm and collapsed cone algorithm provided by Helax-TMS treatment planning system for the same radiation field arrangement for both energies. Dose volume histogram (DVH) in target and organs at risk (OARs) are used for comparison of different plans. The study shows that using pencil beam algorithm, the target DVH are similar for 6 MV and 18 MV plan. However, using collapsed cone algorithm that can make account of lateral electron scattering, the target is underdosed. The change is even more pronounced for 18 MV plan. The doses for lung and spinal cord are similar for these two energies and two algorithms. Therefore, for lung cancer, dose calculation algorithm should have the ability of handling accurately the effect of the tissue density heterogeneity. It is better to use the lower-energy photons (6 MV) than to use the higher-energy photons (18 MV).

Humans↗

Optimization of beam orientations and beam weights for conformal radiotherapy using mixed integer programming.

An algorithm for optimizing beam orientations and beam weights for conformal radiotherapy has been developed. The algorithm models the optimization of beam orientations and beam weights as a problem of mixed integer linear programming (MILP), and optimizes the beam orientations and beam weights simultaneously. The application process of the algorithm has four steps: (a) prepare a pool of beam orientation candidates with the consideration of avoiding any patient-gantry collision and avoiding direct irradiation of organs at risk with quite low tolerances (e.g., eyes). (b) Represent each beam orientation candidate with a binary variable, and each beam weight with a continuous variable. (c) Set up an optimization problem according to dose prescriptions and the maximum allowed number of beam orientations. (d) Solve the optimization problem with a ready-to-use MILP solver. After optimization, the candidates with unity binary variables remain in the final beam configuration. The performance of the algorithm was tested with clinical cases. Compared with standard treatment plans, the beam-orientation-optimized plans had better dose distributions in terms of target coverage and avoidance of critical structures. The optimization processes took less than 1 h on a PC with a Pentium IV 2.4 GHz processor.

Algorithms↗

Conversion of dose-volume constraints to dose limits.

The purpose of this study is to introduce two techniques for converting dose-volume constraints to dose limits for treatment planning optimization, and to evaluate their performance. The first technique, called dose-sorting, is based on the assumption that higher dose limits should be assigned to the constraint points receiving higher doses, and vice versa. The second technique, the hybrid technique, is a hybrid of the dose-sorting technique and the mixed integer linear programming (MILP) technique. Among all constraint points in an organ at risk, the dose limits for the points far from a dose-volume constraint are determined by dose-sorting, while the dose limits for the points close to a dose-volume constraint are determined by MILP. We evaluated the performance of the two new techniques for one treatment geometry by comparing them with the MILP technique. The dose-sorting technique had a high probability of finding the global optimum when no more than three organs at risk have dose-volume constraints. It was much faster than the MILP technique. The hybrid technique always found the global optimum when the MILP percentage (the percentage of constraint points for which the dose limits are determined by the MILP technique) was large enough, but its computation time increased dramatically with the MILP percentage. In conclusion, the dose-sorting technique and the hybrid technique with a low MILP percentage are clinically feasible.

Algorithms↗

Comparison of two algorithms for determining beam weights and wedge filters.

This article compares two algorithms for determining beam weights and wedge filters for conformal treatment planning. One algorithm, which is based on dose-gradient analysis, provides analytic formulas for determining beam weights, wedge angles, and collimator angles (i.e., wedge orientations) so that the dose distribution is homogeneous in the target volume. The second algorithm is based on the concept of the super-omni wedge (i.e., the arrangement of two pairs of orthogonal nominal wedged beams), numerically optimize beam weights, wedge angles, and collimator angles so that the dose requirements to targets and organs at risk are satisfied to the best. Three clinical cases were tested. For the first case, both algorithms resulted in comparable homogeneous dose distributions in the target volume. For the second case, the second algorithm resulted in much lower doses to the eyes plus a better homogeneous dose distribution in the target volume. For the third case, only the second algorithm was applicable, and the treatment plan it developed met the prescribed requirements. The results show that the first algorithm is better in terms of feasibility, whereas the second is better in terms of applicability and the quality of treatment plans.

Algorithms↗