Search PubMed⌕ Search

Biomedical subjects

Jianjun Guan

Publications and source records attributed to Jianjun Guan.

12 recordsLinked to original sources

A seeding device for tissue engineered tubular structures.

One of the challenges in the tissue engineering of tubular tissues and organs is the efficient seeding of porous scaffolds with the desired cell type and density in a short period of time, without affecting cell viability. Though different seeding techniques have been investigated, a fast, reproducible, and efficient bulk seeding method with uniform cellular distribution has yet to be reported. In this paper, a novel seeding device utilizing the synergistic effects of vacuum, centrifugal force and flow has been developed and analyzed. The device allows porous tubular scaffolds to be uniformly bulk seeded as well as luminally surface-seeded with cells. Porous tubular polymer scaffolds were bulk and surface-seeded with cell suspensions, and cell viability and seeding efficiency were subsequently assessed. A rigorous quantitative analysis of shear stresses acting on the cells during the seeding process, and of cell location within the scaffolds following seeding was also performed. Our results showed that the scaffolds were uniformly seeded along the longitudinal and circumferential directions within the tube wall without affecting cell viability or exposing them to excessive shear stresses.

Animals↗

Design and analysis of tissue engineering scaffolds that mimic soft tissue mechanical anisotropy.

Tissue engineered constructs must exhibit tissue-like functional properties, including mechanical behavior comparable to the native tissues they are intended to replace. Moreover, the ability to reversibly undergo large strains can help to promote and guide tissue growth. Electrospun poly (ester urethane) ureas (ES-PEUU) are elastomeric and allow for the control of fiber diameter, porosity, and degradation rate. ES-PEUU scaffolds can be fabricated to have a well-aligned fiber network, which is important for applications involving mechanically anisotropic soft tissues. We have developed ES-PEUU scaffolds under variable speed conditions and modeled the effects of fiber orientation on the macro-mechanical properties of the scaffold. To illustrate the ability to simulate native tissue mechanical behavior, we demonstrated that the high velocity spun scaffolds exhibited highly anisotropic mechanical properties closely resembling the native pulmonary heart valve leaflet. Moreover, use of the present fiber-level structural constitutive model allows for the determination of electrospinning conditions to tailor ES-PEUU scaffolds for specific soft tissue applications. The results of this study will help to provide the basis for rationally designed mechanically anisotropic soft tissue engineered implants.

Anisotropy↗

Development of composite porous scaffolds based on collagen and biodegradable poly(ester urethane)urea.

Our objective in this work was to develop a flexible, biodegradable scaffold for cell transplantation that would incorporate a synthetic component for strength and flexibility and type I collagen for enzymatic lability and cytocompatibility. A biodegradable poly(ester urethane)urea was synthesized from poly(caprolactone), 1,4-diisocyanatobutane, and putrescine. Using a thermally induced phase separation process, porous scaffolds were created from a mixture containing this polyurethane and 0%, 10%, 20%, or 30% type I collagen. The resulting scaffolds were found to have open, interconnected pores (from 7 to >100 um) and porosities from 58% to 86% depending on the polyurethane/collagen ratio. The scaffolds were also flexible with breaking strains of 82-443% and tensile strengths of 0.97-4.11 MPa depending on preparation conditions. Scaffold degradation was significantly increased when collagenase was introduced into an incubating buffer in a manner that was dependent on the mass fraction of collagen present in the scaffold. Mass losses could be varied from 15% to 59% over 8 weeks. When culturing umbilical artery smooth muscle cells on these scaffolds higher cell numbers were observed over a 4-week culture period in scaffolds containing collagen. In summary, a strong and flexible scaffold system has been developed that can degrade by both hydrolysis and collagenase degradation pathways, as well as support cell growth. This scaffold possesses properties that would make it attractive for future use in soft tissue applications where such mechanical and biological features would be advantageous.

Animals↗

Microintegrating smooth muscle cells into a biodegradable, elastomeric fiber matrix.

Electrospinning permits fabrication of biodegradable elastomers into matrices that can resemble the scale and mechanical behavior of the native extracellular matrix. However, achieving high-cellular density and infiltration with this technique remains challenging and time consuming. We have overcome this limitation by electrospraying vascular smooth muscle cells (SMCs) concurrently with electrospinning a biodegradable, elastomeric poly(ester urethane)urea (PEUU). Trypan blue staining revealed no significant decrease in cell viability from the fabrication process and electrosprayed SMCs spread and proliferated similar to control unprocessed SMCs. The resulting SMC microintegrated PEUU constructs were cultured under static conditions or transmural perfusion. Higher cell numbers resulted with perfusion culture with 131% and 98% more viable cells versus static culture at days 4 and 7 (p<0.05). Fluorescent imaging and hematoxylin and eosin staining further illustrated high cell densities integrated between the elastomeric fibers after perfusion culture. SMC microintegrated PEUU was strong, flexible and anisotropic with tensile strengths ranging from 2.0 to 6.5 MPa and breaking strains from 850 to 1,700% dependent on the material axis. The ability to microintegrate smooth muscle or other cell types into a biodegradable elastomer fiber matrix embodies a novel tissue engineering approach that could be applied to fabricate high cell density elastic tissue mimetics, blood vessels or other cardiovascular tissues.

Absorbable Implants↗

Preparation and characterization of highly porous, biodegradable polyurethane scaffolds for soft tissue applications.

In the engineering of soft tissues, scaffolds with high elastance and strength coupled with controllable biodegradable properties are necessary. To fulfill such design criteria we have previously synthesized two kinds of biodegradable polyurethaneureas, namely poly(ester urethane)urea (PEUU) and poly(ether ester urethane)urea (PEEUU) from polycaprolactone, polycaprolactone-b-polyethylene glycol-b-polycaprolactone, 1,4-diisocyanatobutane and putrescine. PEUU and PEEUU were further fabricated into scaffolds by thermally induced phase separation using dimethyl sulfoxide (DMSO) as a solvent. The effect of polymer solution concentration, quenching temperature and polymer type on pore morphology and porosity was investigated. Scaffolds were obtained with open and interconnected pores having sizes ranging from several mum to more than 150 microm and porosities of 80-97%. By changing the polymer solution concentration or quenching temperature, scaffolds with random or oriented tubular pores could be obtained. The PEUU scaffolds were flexible with breaking strains of 214% and higher, and tensile strengths of approximately 1.0 MPa, whereas the PEEUU scaffolds generally had lower strengths and breaking strains. Scaffold degradation in aqueous buffer was related to the porosity and polymer hydrophilicity. Smooth muscle cells were filtration seeded in the scaffolds and it was shown that both scaffolds supported cell adhesion and growth, with smooth muscle cells growing more extensively in the PEEUU scaffold. These biodegradable and flexible scaffolds demonstrate potential for future application as cell scaffolds in cardiovascular tissue engineering or other soft tissue applications.

Absorbable Implants↗

Fabrication of biodegradable elastomeric scaffolds with sub-micron morphologies.

The native extracellular matrix (ECM) of elastic tissues is strong and flexible and supports cell adhesion and enzymatic matrix remodeling. In an attempt to convey these ECM properties to a synthetic scaffold appropriate for soft tissue engineering applications, a biodegradable, elastomeric poly(ester urethane)urea (PEUU) was combined with type I collagen at various ratios (2.5, 5, 10, 20, 50, 60, 70, 80, and 90 wt% collagen) and electrospun to construct elastic matrices. Randomly orientated fibers in the electrospun matrices ranged in diameter from 100-900 nm, dependent on initial polymer concentration. Picrosirius red staining of matrices and CD spectroscopy of released collagen confirmed collagen incorporation and preservation of collagen structure at the higher collagen mass fractions. Matrices were strong and distensible possessing strengths of 2-13 MPa with breaking strains of 160-280% even with low PEUU content. Collagen incorporation significantly enhanced smooth muscle cell adhesion onto electrospun scaffolds. An approach has been demonstrated that mimics elastic extracellular matrices by using a synthetic component to provide mechanical function together with a biomacromolecule, collagen. Such matrices may find application in engineering soft tissue.

Absorbable Implants↗

Biodegradable poly(ether ester urethane)urea elastomers based on poly(ether ester) triblock copolymers and putrescine: synthesis, characterization and cytocompatibility.

Polymers with elastomeric mechanical properties, tunable biodegradation properties and cytocompatibility would be desirable for numerous biomedical applications. Toward this end a series of biodegradable poly(ether ester urethane)urea elastomers (PEEUUs) based on poly(ether ester) triblock copolymers were synthesized and characterized. Poly(ether ester) triblock copolymers were synthesized by ring-opening polymerization of epsilon-caprolactone with polyethylene glycol (PEG). PEEUUs were synthesized from these triblock copolymers and butyl diisocyanate, with putrescine as a chain extender. PEEUUs exhibited low glass transition temperatures and possessed tensile strengths ranging from 8 to 20MPa and breaking strains from 325% to 560%. Increasing PEG length or decreasing poly(caprolactone) length in the triblock segment increased PEEUU water absorption and biodegradation rate. Human umbilical vein endothelial cells cultured in a medium supplemented with PEEUU biodegradation solution suggested a lack of degradation product cytotoxicity. Endothelial cell adhesion to PEEUUs was less than 60% of tissue culture polystyrene and was inversely related to PEEUU hydrophilicity. Surface modification of PEEUUs with ammonia gas radio-frequency glow discharge and subsequent immobilization of the cell adhesion peptide Arg-Gly-Asp-Ser increased endothelial adhesion to a level equivalent to tissue culture polystyrene. These biodegradable PEEUUs thus possessed properties that would be amenable to applications where high strength and flexibility would be desirable and exhibited the potential for tuning with appropriate triblock segment selection and surface modification.

Absorbable Implants↗

Promoting the cytocompatibility of polyurethane scaffolds via surface photo-grafting polymerization of acrylamide.

Polyurethane (PU) porous scaffolds were modified by grafting polymerization of acrylamide (AAm) initiated under UV light. A pre-adsorbing-monomer method was used beforehand. FTIR-ATR spectroscopy and X-ray photoelectron spectroscopy (XPS) measurements confirmed the presence of grafted PAAm on PU scaffolds. The measurement of water adsorption demonstrated the improvement of hydrophilicity after PU scaffolds were grafted with polyacrylamide (PAAm). The PAAm grafting degree related to the amount of AAm adsorbed, average pore diameter, and the degree of porosity. This study shows that higher degree of porosity and bigger porous areas yielded larger amounts of absorbed AAm and higher grafting degrees. In vitro human endothelial cell cultures of PU scaffolds modified with hydrophilic PAAm showed better cytocompatibility than the control matrix.

Acrylic Resins↗

Engineering porous polyurethane scaffolds by photografting polymerization of methacrylic acid for improved endothelial cell compatibility.

Using a preadsorbing-monomer method, polyurethane (PU) porous scaffolds were modified by grafting polymerization of methacrylic acid (MAA) initiated under UV light. Fourier transform infrared-attenuated total reflection spectroscopy and X-ray photoelectron spectroscopy characterizations confirmed the occurrence of the grafting polymerization of poly(methacrylic acid) (PMAA) on PU scaffolds and the measurement of water adsorption also demonstrated enhanced hydrophilicity. The PMAA grafting degree correlated to the amount of MAA adsorbed, the pore average diameter, and the porosity. It was verified that the higher porosity the scaffold has, the larger porous area (or the larger contact area with MAA) it has, and therefore the higher amount of MAA adsorbed and higher grafting degree obtained. The results of human endothelial cells cultured in vitro showed that the PU scaffolds modified with the hydrophilic PMAA had more improved cell compatibility than the control matrix.

Cell Adhesion↗

Photografting of poly(hydroxylethyl acrylate) onto porous polyurethane scaffolds to improve their endothelial cell compatibility.

In order to improve the cytocompatibility of polyurethane (PU) porous scaffolds obtained by thermally-induced phase separation, poly(hydroxylethyl acrylate) (PHEA) was covalently immobilized by grafting copolymerization of HEA by photo-oxidation of the scaffolds and initiation of UV light. FT-IR-ATR spectroscopy and X-ray photoelectron spectroscopy (XPS) characterizations confirmed the occurrence of the grafting co-polymerization of HEA on the porous PU scaffolds. The measurement of water absorption demonstrated the improvement of the hydrophilicity after grafting with PHEA. The results obtained in a human umbilical vein endothelial cell (HUVEC) culture proved that the porous PU scaffold modified with the hydrophilic PHEA had better cytocompatibility than the control. The influence of surface pore size on the HUVEC growth behavior was assessed regarding cell anchorage, proliferation and viability, as well as morphology. An overall increase of cell number and viability with the decrease of the surface pore size was found.

Absorption↗

Synthesis, characterization, and cytocompatibility of elastomeric, biodegradable poly(ester-urethane)ureas based on poly(caprolactone) and putrescine.

The engineering of tissue for mechanically demanding applications in the cardiovascular system is likely to require mechanical conditioning of cell-scaffold constructs prior to their implantation. Scaffold properties amenable to such an application include high elasticity and strength coupled with controllable biodegradative and cell-adhesive properties. To fulfill such design criteria, we have synthesized a family of poly(ester-urethane)ureas (PEUUs) from polycaprolactone and 1,4-diisocyanatobutane. Lysine ethyl ester (Lys) or putrescine was used as chain extenders. To encourage cell adhesion, PEUUs were surface modified with radio-frequency glow discharge followed by coupling of Arg-Gly-Asp-Ser (RGDS). The synthesized PEUUs were highly flexible, with breaking strains of 660-895% and tensile strengths from 9.2-29 MPa. Incubation in aqueous buffer for 8 weeks resulted in mass loss, from >50% (Lys chain extender) to 10% (putrescine chain extender). Human endothelial cells cultured for 4 days with medium containing the degradation products from PEUUs with either the Lys or putrescine chain extender showed no toxic effects. Cell adhesion was 85% of that measured on tissue-culture polystyrene for unmodified PEUU surfaces (p < 0.01) and >160% (p < 0.001) of polystyrene on RGDS-modified PEUUs. These biodegradable PEUUs demonstrate potential for future application as cell scaffolds in cardiovascular tissue-engineering or other soft-tissue applications.

Absorbable Implants↗

Synthesis, characterization and cytocompatibility of polyurethaneurea elastomers with designed elastase sensitivity.

In designing a synthetic scaffold for engineering soft, mechanically active tissues, desirable properties include elasticity, support of cell adhesion and growth, ease of processability, and responsiveness to in vivo remodeling. To achieve these properties, we have developed a family of thermoplastic elastomers, polyurethaneureas (PUs), that possess enzymatic remodeling capabilities in addition to simple hydrolytic lability. PUs were synthesized using either polycaprolactone or triblock copolymer polycaprolactone-b-poly(ethylene glycol)-b-polycaprolactone as the soft segment, 1,4-butanediisocyanate as the hard segment, and the peptide Ala-Ala-Lys as a chain extender. The synthesized PUs had high molecular weights, low glass transition temperatures (< -54 degrees C), and were flexible with breaking strains of 670-890% and tensile strengths of 15-28 MPa. Incubation in buffered saline without elastase for 8 weeks resulted in mass loss from 12% to 18% depending on soft segment composition. The degradation significantly increased (p < 0.05) in the presence of elastase, ranging from 19% to 34% with degradation products showing no cytotoxicity. To encourage cell adhesion, PUs were surface-modified with radio frequency glow discharge followed by coupling of Arg-Gly-Asp-Ser (RGDS). Endothelial cell adhesion was >140% of tissue culture polystyrene on PU surfaces and >200% on RGDS-modified surfaces. The synthesized PUs thus combine mechanical, chemical, and bioresponsive properties that might be employed in soft-tissue engineering applications.

Absorption↗