Tilted cone-beam reconstruction with row-wise fan-to-parallel rebinning.

Reconstruction algorithms for cone-beam CT have been the focus of many studies. Several exact and approximate reconstruction algorithms were proposed for step-and-shoot and helical scanning trajectories to combat cone-beam related artefacts. In this paper, we present a new closed-form cone-beam reconstruction formula for tilted gantry data acquisition. Although several algorithms were proposed in the past to combat errors induced by the gantry tilt, none of the algorithms addresses the scenario in which the cone-beam geometry is first rebinned to a set of parallel beams prior to the filtered backprojection. We show that the image quality advantages of the rebinned parallel-beam reconstruction are significant, which makes the development of such an algorithm necessary. Because of the rebinning process, the reconstruction algorithm becomes more complex and the amount of iso-centre adjustment depends not only on the projection and tilt angles, but also on the reconstructed pixel location. In this paper, we first demonstrate the advantages of the row-wise fan-to-parallel rebinning and derive a closed-form solution for the reconstruction algorithm for the step-and-shoot and constant-pitch helical scans. The proposed algorithm requires the 'warping' of the reconstruction matrix on a view-by-view basis prior to the backprojection step. We further extend the algorithm to the variable-pitch helical scans in which the patient table travels at non-constant speeds. The algorithm was tested extensively on both the 16- and 64-slice CT scanners. The efficacy of the algorithm is clearly demonstrated by multiple experiments.

Algorithms↗

A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.

Based on the structure of the original helical FDK algorithm, a three-dimensional (3D)-weighted cone beam filtered backprojection (CB-FBP) algorithm is proposed for image reconstruction in volumetric CT under helical source trajectory. In addition to its dependence on view and fan angles, the 3D weighting utilizes the cone angle dependency of a ray to improve reconstruction accuracy. The 3D weighting is ray-dependent and the underlying mechanism is to give a favourable weight to the ray with the smaller cone angle out of a pair of conjugate rays but an unfavourable weight to the ray with the larger cone angle out of the conjugate ray pair. The proposed 3D-weighted helical CB-FBP reconstruction algorithm is implemented in the cone-parallel geometry that can improve noise uniformity and image generation speed significantly. Under the cone-parallel geometry, the filtering is naturally carried out along the tangential direction of the helical source trajectory. By exploring the 3D weighting's dependence on cone angle, the proposed helical 3D-weighted CB-FBP reconstruction algorithm can provide significantly improved reconstruction accuracy at moderate cone angle and high helical pitches. The 3D-weighted CB-FBP algorithm is experimentally evaluated by computer-simulated phantoms and phantoms scanned by a diagnostic volumetric CT system with a detector dimension of 64 x 0.625 mm over various helical pitches. The computer simulation study shows that the 3D weighting enables the proposed algorithm to reach reconstruction accuracy comparable to that of exact CB reconstruction algorithms, such as the Katsevich algorithm, under a moderate cone angle (4 degrees) and various helical pitches. Meanwhile, the experimental evaluation using the phantoms scanned by a volumetric CT system shows that the spatial resolution along the z-direction and noise characteristics of the proposed 3D-weighted helical CB-FBP reconstruction algorithm are maintained very well in comparison to the FDK-type algorithms. Moreover, the experimental evaluation by clinical data verifies that the proposed 3D-weighted CB-FBP algorithm for image reconstruction in volumetric CT under helical source trajectory meets the challenges posed by diagnostic applications of volumetric CT imaging.

Algorithms↗

Data consistency based translational motion artifact reduction in fan-beam CT.

A basic assumption in the classic computed tomography (CT) theory is that an object remains stationary in an entire scan. In biomedical CT/micro-CT, this assumption is often violated. To produce high-resolution images, such as for our recently proposed clinical micro-CT (CMCT) prototype, it is desirable to develop a precise motion estimation and image reconstruction scheme. In this paper, we first extend the Helgason-Ludwig consistency condition (HLCC) from parallel-beam to fan-beam geometry when an object is subject to a translation. Then, we propose a novel method to estimate the motion parameters only from sinograms based on the HLCC. To reconstruct the moving object, we formulate two generalized fan-beam reconstruction methods, which are in filtered backprojection and backprojection filtering formats, respectively. Furthermore, we present numerical simulation results to show that our approach is accurate and robust.

Algorithms↗

Development and evaluation of an exact fan-beam reconstruction algorithm using an equal weighting scheme via locally compensated filtered backprojection (LCFBP).

A novel exact fan-beam image reconstruction formula is presented and validated using both phantom data and clinical data. This algorithm takes the form of the standard ramp filtered backprojection (FBP) algorithm plus local compensation terms. This algorithm will be referred to as a locally compensated filtered backprojection (LCFBP). An equal weighting scheme is utilized in this algorithm in order to properly account for redundantly measured projection data. The algorithm has the desirable property of maintaining a mathematically exact result for: the full scan mode (2pi), the short scan mode (pi+ full fan angle), and the supershort scan mode [less than (pi+ full fan angle)]. Another desirable feature of this algorithm is that it is derivative-free. This feature is beneficial in preserving the spatial resolution of the reconstructed images. The third feature is that an equal weighting scheme has been utilized in the algorithm, thus the new algorithm has better noise properties than the standard filtered backprojection image reconstruction with a smooth weighting function. Both phantom data and clinical data were utilized to validate the algorithm and demonstrate the superior noise properties of the new algorithm.

Algorithms↗

Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography.

Coronary artery imaging with x-ray computed tomography (CT) is one of the most recent advancements in CT clinical applications. Although existing "state-of-the-art" clinical protocols today utilize helical data acquisition, it suffers from the lack of ability to handle irregular heart rate and relatively high x-ray dose to patients. In this paper, we propose a step-and-shoot data acquisition protocol that significantly overcomes these shortcomings. The key to the proposed protocol is the large volume coverage (40 mm) enabled by the cone beam CT scanner, which allows the coverage of the entire heart in 3 to 4 steps. In addition, we propose a gated complementary reconstruction algorithm that overcomes the longitudinal truncation problem resulting from the cone beam geometry. Computer simulations, phantom experiments, and clinical studies were conducted to validate our approach.

Algorithms↗

General formula for fan-beam computed tomography.

In this Letter, we derive a general reconstruction formula for fan-beam computed tomography (CT) utilizing the two-dimensional Dirac function, which is useful in CT imaging for moving objects.

Algorithms↗

A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.

The original FDK algorithm proposed for cone beam (CB) image reconstruction under a circular source trajectory has been extensively employed in medical and industrial imaging applications. With increasing cone angle, CB artefacts in images reconstructed by the original FDK algorithm deteriorate, since the circular trajectory does not satisfy the so-called data sufficiency condition (DSC). A few 'circular plus' trajectories have been proposed in the past to help the original FDK algorithm to reduce CB artefacts by meeting the DSC. However, the circular trajectory has distinct advantages over other scanning trajectories in practical CT imaging, such as head imaging, breast imaging, cardiac, vascular and perfusion applications. In addition to looking into the DSC, another insight into the CB artefacts existing in the original FDK algorithm is the inconsistency between conjugate rays that are 180 degrees apart in view angle (namely conjugate ray inconsistency). The conjugate ray inconsistency is pixel dependent, varying dramatically over pixels within the image plane to be reconstructed. However, the original FDK algorithm treats all conjugate rays equally, resulting in CB artefacts that can be avoided if appropriate weighting strategies are exercised. Along with an experimental evaluation and verification, a three-dimensional (3D) weighted axial cone beam filtered backprojection (CB-FBP) algorithm is proposed in this paper for image reconstruction in volumetric CT under a circular source trajectory. Without extra trajectories supplemental to the circular trajectory, the proposed algorithm applies 3D weighting on projection data before 3D backprojection to reduce conjugate ray inconsistency by suppressing the contribution from one of the conjugate rays with a larger cone angle. Furthermore, the 3D weighting is dependent on the distance between the reconstruction plane and the central plane determined by the circular trajectory. The proposed 3D weighted axial CB-FBP algorithm can be implemented in either the native CB geometry or the so-called cone-parallel geometry. By taking the cone-parallel geometry as an example, the experimental evaluation shows that, up to a moderate cone angle corresponding to a detector dimension of 64 x 0.625 mm, the CB artefacts can be substantially suppressed by the proposed algorithm, while advantages of the original FDK algorithm, such as the filtered backprojection algorithm structure, 1D ramp filtering and data manipulation efficiency, are maintained.

Algorithms↗

Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography.

We present an exact filtered backprojection reconstruction formula for helical cone beam computed tomography in which the pitch of the helix varies with time. We prove that the resulting algorithm, which is functionally identical to the constant pitch case, provides exact reconstruction provided that the projection of the helix onto the detector forms convex boundaries and that PI lines are unique. Furthermore, we demonstrate that both of these conditions are satisfied provided the sum of the translational velocity and the derivative of the translational acceleration does not change sign. As a special case, we show that gantry tilt can also be handled by our dynamic pitch formula. Simulation results demonstrate the resulting algorithm.

Algorithms↗

Fractional scan algorithms for low-dose perfusion CT.

One of the key considerations in CT perfusion is the X-ray dose received by the patient, since cine acquisition mode is typically used in which repeated x-ray exposure occurs at the same anatomical location. In this technical note, we propose a new approach for dose reduction in which the X-ray tube current is maintained and the number of projection views is reduced per gantry rotation. A projection interpolation algorithm and an image prediction algorithm are developed to address the incompleteness of such projection data. Both algorithms utilize a priori knowledge that the contrast-uptake in perfusion images is gradual and predictable. As a result, excellent perfusion images can be reconstructed at a fraction of the nominal radiation dose.

Algorithms↗

A filtered backprojection algorithm for cone beam reconstruction using rotational filtering under helical source trajectory.

With the evolution from multi-detector-row CT to cone beam (CB) volumetric CT, maintaining reconstruction accuracy becomes more challenging. To combat the severe artifacts caused by a large cone angle in CB volumetric CT, three-dimensional reconstruction algorithms have to be utilized. In practice, filtered backprojection (FBP) reconstruction algorithms are more desirable due to their computational structure and image generation efficiency. One of the CB-FBP reconstruction algorithms is the well-known FDK algorithm that was originally derived for a circular x-ray source trajectory by heuristically extending its two-dimensional (2-D) counterpart. Later on, a general CB-FBP reconstruction algorithm was derived for noncircular, such as helical, source trajectories. It has been recognized that a filtering operation in the projection data along the tangential direction of a helical x-ray source trajectory can significantly improve the reconstruction accuracy of helical CB volumetric CT. However, the tangential filtering encounters latitudinal data truncation, resulting in degraded noise characteristics or data manipulation inefficiency. A CB-FBP reconstruction algorithm using one-dimensional rotational filtering across detector rows (namely CB-RFBP) is proposed in this paper. Although the proposed CB-RFBP reconstruction algorithm is approximate, it approaches the reconstruction accuracy that can be achieved by exact helical CB-FBP reconstruction algorithms for moderate cone angles. Unlike most exact CB-FBP reconstruction algorithms in which the redundant data are usually discarded, the proposed CB-RFBP reconstruction algorithm make use of all available projection data, resulting in significantly improved noise characteristics and dose efficiency. Moreover, the rotational filtering across detector rows not only survives the so-called long object problem, but also avoids latitudinal data truncation existing in other helical CB-FBP reconstruction algorithm in which a tangential filtering is carried out, providing better noise characteristics, dose efficiency and data manipulation efficiency.

Algorithms↗

Investigation of an image artefact induced by projection noise inhomogeneity in multi-slice helical computed tomography.

The introduction of multi-slice helical computed tomography has fundamentally changed the way radiologists view CT images. Increasing numbers of clinical cases are examined with advanced visualization tools, such as maximum intensity projection, multi-planar reformation and volume rendering. It has been discovered that new image artefacts, which do not appear in the traditional two-dimensional reconstructed images, become visible in images generated by these new tools. In this paper, we investigate the causes of one such artefact, the Venetian blind artefact, which appears as bright-and-dark bands superimposed on three-dimensional images. We demonstrate that such an artefact is caused by the periodical noise variation in the reconstructed images. The image noise variation is, in turn, caused by the interaction of the noise inhomogeneity in the projections with the helical weights. An analytical formula is developed that accurately predicts the presence of such artefacts. Based on our analysis, several approaches are proposed for the artefact reduction or elimination.

Artifacts↗

Analytical models for multi-slice helical CT performance parameters.

One of the most recent technological advancements in computed tomography (CT) is the introduction of multi-slice CT (MSCT). When combined with the helical scan mode, MSCT offers significant improvements in volume coverage, isotropic spatial resolution, and contrast utilization. Although experimental studies have been conducted on MSCT performance, there is a lack of theoretical analysis on the slice sensitivity profile (SSP) and noise performance. In this paper, we derive several closed-form expressions, for linear interpolation based helical reconstruction algorithms, to characterize these performance parameters under different detector configurations and acquisition modes. Following the common practice, the expressions are explicitly described for regions near the iso-center, although the same approach can be used to describe system performances away from the iso-center. These models are validated against phantom experiments.

Algorithms↗

Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients.

OBJECTIVE: Limiting CT radiation dose is especially critical when imaging children. The purpose of our study was to modify and test an accurate and safe tool for evaluating systematic dose reduction for abdominal multidetector CT (MDCT) in pediatric patients. MATERIALS AND METHODS: After validating the computer-simulation technique with a water phantom, we subjected the original digital scanning data for 26 contrast-enhanced abdominal MDCT scans (120 mA) obtained in infants and children (age range, 1 month-9 years; mean age, 3.1 years) to simulated tube current reduction (100, 80, 60, and 40 mA) by adding noise. this procedure created four additional examinations per child that were identical to the originals except for image noise. The 130 examinations were scored randomly, independently, and without prior knowledge of the children's diagnoses by three radiologists for depiction of high-visibility structures, such as adrenal glands and fat in the intrahepatic falciform ligament, and low-visibility structures, such as the extrahepatic hepatic artery, small intrahepatic vessels, and common bile duct. Aligned rank and Wilcoxon's signed rank tests were used for statistical analyses. RESULTS: Simulated tube current reduction significantly affected the detection of low-visibility structures (p < 0.001). Reduced detection in low-visibility structures was evident at a level less than or equal to 80 mA. No loss of detection in high-visibility structures was found at any tube current level (p > 0.5). CONCLUSION: The results of this computer simulation suggest that accurate abdominal MDCT can be performed in pediatric patients using substantially reduced radiation, depending on the indication for imaging. (In our case, the reduction was between 33% and 67%, depending on whether a high-visibility or low-visibility structure was being assessed.) This simulation technology can be applied to MDCT of other organ systems for systematic evaluation of radiation dose reduction.

Child↗