Search PubMed⌕ Search

Biomedical subjects

Jessica Olofsson

Publications and source records attributed to Jessica Olofsson.

8 recordsLinked to original sources

Generation of focused electric field patterns at dielectric surfaces.

We here report on a concept for creating well-defined electric field gradients between the boundaries of capillary electrode (a capillary of a nonconducting material equipped with an interior metal electrode) outlets, and dielectric surfaces. By keeping a capillary electrode opening close to a boundary between a conducting solution and a nonconducting medium, a high electric field can be created close to the interface by field focusing effects. By varying the inner and outer diameters of the capillary, the span of electric field strengths and the field gradient obtained can be controlled, and by varying the slit height between the capillary rim and the surface, or the applied current, the average field strength and gradient can be varied. Field focusing effects and generation of electric field patterns were analyzed using finite element method simulations. We experimentally verified the method by electroporation of a fluorescent dye (fluorescein diphosphate) into adherent, monolayered cells (PC-12 and WSS-1) and obtained a pattern of fluorescent cells corresponding to the focused electric field.

Animals↗

Microfluidic gradient-generating device for pharmacological profiling.

We describe an on-chip microfluidic gradient-generating device that generates concentration gradients spanning nearly 5 orders of magnitude starting from a single concentration. The exiting stream of drugs held at different concentrations remains laminar in a recording chamber and can be presented as 24 discrete solutions to a cell-based sensor. The high-performance characteristics of the device are demonstrated by pharmacological screening of voltage-gated K+ channels (hERG) and ligand-gated GABA(A) receptors using scanning-probe patch-clamp measurements. Multiple data point dose-response curves and IC50 and EC50 values were rapidly obtained, typically in less than 30 min, through its combined functionality of gradient generation and open-volume laminar flow. The device facilitates rapid pharmacological profiling of ion channel and GPCR effectors and enables the acquisition of large numbers of data points with minute sample consumption and handling.

Animals↗

Single-file electrophoretic transport and counting of individual DNA molecules in surfactant nanotubes.

We demonstrate a complete nanotube electrophoresis system (nanotube radii in the range of 50 to 150 nm) based on lipid membranes, comprising DNA injection, single-molecule transport, and single-molecule detection. Using gel-capped electrodes, electrophoretic single-file transport of fluorescently labeled dsDNA molecules is observed inside nanotubes. The strong confinement to a channel of molecular dimensions ensures a detection efficiency close to unity and identification of DNA size from its linear relation to the integrated peak intensity. In addition to constituting a nanotechnological device for identification and quantification of single macromolecules or biopolymers, this system provides a method to study their conformational dynamics, reaction kinetics, and transport in cell-like environments.

Bacteriophage phi X 174↗

A chemical waveform synthesizer.

Algorithms and methods were developed to synthesize complex chemical waveforms in open volumes by using a scanning-probe microfluidic platform. Time-dependent variations and oscillations of one or several chemical species around the scanning probe, such as formation of sine waves, damped oscillations, and generation of more complex patterns, are demonstrated. Furthermore, we show that intricate bursting and chaotic calcium oscillations found in biological microdomains can be reproduced and that a biological cell can be used as a probe to study receptor functionalities as a function of exposure to time-dependent variations of receptor activators and inhibitors. Thus, the method allows for studies of biologically important oscillatory reactions. More generally, the system allows for detailed studies of complex time-varying chemical and physical phenomena in solution or at solution/surface interfaces.

Algorithms↗

A microfluidics approach to the problem of creating separate solution environments accessible from macroscopic volumes.

We report on a microfluidic device that generates separate solution environments in macroscopic volumes. Spatially distinct patterns are created by emitting fluids from 16 different sources (closely spaced microchannels) into a solution-filled macroscopic chamber. The fluid in neighboring microchannels couples viscously in the macroscopic container, generating one single interdigitated stream. Scanning nanoelectrode amperometry was used for characterizing the concentration landscape and the diffusion zones between solutions running in parallel at different coordinates in the stream. These experiments were complemented by finite element simulations of the Navier-Stokes and mass transport equations to describe the velocity distributions and the diffusion behavior. For in channel flow velocities of 50 mm.s(-1), patterns could persist on the order of millimeters to centimeters in the open volume. The most narrow diffusion zones with widths less than 10 microm (5-95% concentration change) were found some tens of micrometers out in the macroscopic container. We demonstrate that a 14-microm-diameter nearly spherical object (biological cell) attached to a micropipet can be moved from one solution environment to another by a lateral displacement of only 8 microm. The device is suitable for applications where the solution environment around a microscopic or nanoscopic sensor needs to be changed multiple times, i.e., in order to build layered structures, for obtaining binding isotherms, and kinetic information, for example, on ion channels, enzymes, and receptors as well as in applications where different loci on an object need to be exposed to different environments or where complex solution environments need to be created for studies of interfacial chemistry between two streaming layers.

Journal Article↗

Stabilization of high-resistance seals in patch-clamp recordings by laminar flow.

The formation of a high-resistance electrical seal between a cell membrane and a glass micropipet tip is essential in patch-clamp experiments. We have studied the electrical properties and the mechanical stability of the seal using a microfluidic chip generating laminar flow in open volumes. We show that, by using fluid flow (1-10 mm/s) acting along the symmetry axis of the cell-pipet, seals of a higher mechanical stability with increased resistances can be achieved, allowing up to 100% longer recording times and over 40% decreased noise levels (Irms). These improved properties are beneficial for high-sensitivity patch-clamp recordings, in particular, in longtime studies of ion channel receptor systems that are relevant in biosensor applications of the technique. Furthermore, these observations support the combination of patch-clamp with microfluidic devices, for example, for rapid solution exchange around a single cell sensor for high-throughput electrophysiology and for highly resolved kinetic studies.

Journal Article↗

Single-cell electroporation.

Electroporation is a widely used method for the introduction of polar and charged agents such as dyes, drugs, DNA, RNA, proteins, peptides, and amino acids into cells. Traditionally, electroporation is performed with large electrodes in a batch mode for treatment of a large number of cells in suspension. Recently, microelectrodes that can produce extremely localized electric fields, such as solid carbon fiber microelectrodes, electrolyte-filled capillaries and micropipettes as well as chip-based microfabricated electrode arrays, have proven useful to electroporate single cells and subcellular structures. Single-cell electroporation opens up a new window of opportunities in manipulating the genetic, metabolic, and synthetic contents of single targeted cells in tissue slices, cell cultures, in microfluidic channels or at specific loci on a chip-based device.

Cell Membrane Permeability↗

A cell-based bar code reader for high-throughput screening of ion channel-ligand interactions.

This paper presents a microfluidics-patch clamp platform for performing high-throughput screening and rapid characterization of weak-affinity ion channel-ligand interactions. This platform integrates a microfluidic chip consisting of multiple channels entering an open volume with standard patch clamp equipment. The microfluidic chip is placed on a motorized scanning stage and the method relies on the ability to scan rapidly, on the order of milliseconds, a patch-clamped cell across discrete zones of different solutions created in the open volume. Under ideal conditions, this method has the capacity to obtain kinetically resolved patch clamp measurements and dose-response curves of up to 10(3) ligand solutions in a single day.

Animals↗