A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability.

We describe a microfluidic genetic analysis system that represents a previously undescribed integrated microfluidic device capable of accepting whole blood as a crude biological sample with the endpoint generation of a genetic profile. Upon loading the sample, the glass microfluidic genetic analysis system device carries out on-chip DNA purification and PCR-based amplification, followed by separation and detection in a manner that allows for microliter samples to be screened for infectious pathogens with sample-in-answer-out results in < 30 min. A single syringe pump delivers sample/reagents to the chip for nucleic acid purification from a biological sample. Elastomeric membrane valving isolates each distinct functional region of the device and, together with resistive flow, directs purified DNA and PCR reagents from the extraction domain into a 550-nl chamber for rapid target sequence PCR amplification. Repeated pressure-based injections of nanoliter aliquots of amplicon (along with the DNA sizing standard) allow electrophoretic separation and detection to provide DNA fragment size information. The presence of Bacillus anthracis (anthrax) in 750 nl of whole blood from living asymptomatic infected mice and of Bordetella pertussis in 1 microl of nasal aspirate from a patient suspected of having whooping cough are confirmed by the resultant genetic profile.

DNA↗

Chitosan as a polymer for pH-induced DNA capture in a totally aqueous system.

A novel DNA solid-phase extraction protocol based on the pH-dependent charge of chitosan was developed specifically for low-volume DNA extraction on microchips. The method uses chitosan-coated beads to extract DNA at pH 5 and release it from the chitosan at pH 9. DNA extraction efficiency as high as 92% could be attained, even from complex samples such as human blood containing significant amounts of protein. Using this method, PCR inhibitors that are typically used in DNA extraction procedures (e.g., chaotropic salts, 2-propanol) can be avoided, making the method more conducive to downstream sample processing using PCR. A high-density multichannel microchip device was then fabricated and the microchannels coated with chitosan for DNA extraction in an open channel configuration without the need for an additional stationary phase. This design provided a relatively high surface area-to-volume ratio for extraction, while retaining the low flow resistance commensurate with open channels. With a flow rate of approximately 1 microL/min during the extraction, the total extraction time was less than 10 min, with most of the DNA recovered in the first 2 microL of elution buffer. Using the microchip device, extraction efficiencies for lambda-phage DNA and human genomic DNA were as high as 67 and 63%, respectively. Human genomic DNA from whole blood samples could be extracted in 10 min with an extraction efficiency of 75 +/- 4% (n = 3), and the purified DNA was suitable for PCR amplification of a fragment of the gelsolin gene. The combination of an entirely aqueous DNA extraction method with a high-density, low-flow resistance microchannel pattern sets the stage for future integration into microfluidic genomic analysis devices.

Chitosan↗

Microchip-based macroporous silica sol-gel monolith for efficient isolation of DNA from clinical samples.

Effective microchip extraction of deoxyribonucleic acid (DNA) from crude biological matrixes has been demonstrated using silica beads or hybrid phases composed of beads and sol-gel. However, the use of monolithic sol-gels alone for extraction of human genomic DNA has been more difficult to define. Here we describe, for the first time, the successful use of monolithic tetramethyl orthosilicate-based sol-gels for effective micro-solid-phase extraction (muSPE) of DNA in a glass microchip format. A functional monolithic silica phase with micrometer-scale pores in the silica matrix resulted from addition of poly(ethylene glycol), a poragen, to the precursor mixture. This allowed a monolithic sol-gel bed to be established in a microchip channel that provided large surface area for DNA extraction with little flow-induced back pressure. DNA extraction efficiencies for simple systems (lambda-phage DNA) were approximately 85%, while efficiencies for the reproducible extraction of human genomic DNA from complex biological matrixes (human blood) were approximately 70%. Blockage of the sol-gel pores by components in the lysed blood was observed in repeat extraction on a single device as a decrease in the extraction efficiency. The developed muSPE protocol was further evaluated to show applicability to clinical samples and bacterial cultures, through extraction of PCR-amplifiable DNA.

DNA↗

Quenching of the electrochemiluminescence of tris(2,2'-bipyridine)ruthenium(II) by ferrocene and its potential application to quantitative DNA detection.

Efficient and stable quenching of electrochemiluminescence (ECL) of tris(2,2'-bipyridine)ruthenium(II) by oxidizing ferrocene methanol (FcMeOH) at the electrode is reported. Bimolecular energy or electron transfer between Ru(bpy)(3)(2+*) and ferrocenium (Fc(+)), the oxidized species of Fc, along with suppression of radical reactions is suggested as the mechanism for quenching ECL. Fc shows more efficient quenching of ECL compared with the known quenchers phenol and 1,1-dimethyl-4,4'-bipyridine dication (MV(2+)). The ECL quenching rate constant was 5.6 x 10(10) M(-)(1) s(-)(1). Using Fc as a quencher label on a complementary DNA sequence, an intramolecular ECL quenching in hybridized oligonucleotide strands has been realized. With essentially complete quenching efficiency, this system has the potential for application to sequence-specific DNA detection.

2,2'-Dipyridyl↗

A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples.

A glass microdevice has been constructed for the on-line integration of solid-phase extraction (SPE) of DNA and polymerase chain reaction (PCR) on a single chip. The chromatography required for SPE in the microfluidic sample preparation device (muSPD) was carried out in a silica bead/sol-gel SPE bed, where the purified DNA was eluted directly into a downstream chamber where conventional thermocycling allowed for PCR amplification of specific DNA target sequences. Through rapid, simple passivation of the PCR chamber with a silanizing reagent, reproducible DNA extraction and amplification was demonstrated from complex biological matrixes in a manner amenable to any research laboratory, using only a syringe pump and a conventional thermocycler. The muSPD allowed for SPE concentration of DNA from 600 nL of blood coupled to subsequent on-chip amplification that yielded a detectable amplicon; this simple device can be applied to a variety of routine genetic analyses without the need for sophisticated instrumentation. In addition, the applicability of these developments to nonconventional thermocycling was demonstrated through the use of noncontact, IR-mediated heating. This was exemplified with the isolation of DNA from an anthrax spore-spiked nasal swab and the subsequent on-chip amplification of target DNA sequences in a total processing time of only 25 min.

DNA↗

DNA extraction using a tetramethyl orthosilicate-grafted photopolymerized monolithic solid phase.

A novel high-capacity, high-efficiency DNA extraction method is described using a photopolymerized silica-based monolithic column in a fused-silica capillary. Development involved investigation of the composition of the sol-gel monomer, fabrication conditions, and surface modifications in order to optimize the binding capacity. Extraction capacity and efficiency with the 3-(trimethoxysilyl)propyl methacrylate (TMSPM) monolith formulations fabricated in capillaries were investigated using a simple three-step procedure consisting of sample loading, washing of the solid phase, and elution of the DNA using a low ionic strength Tris buffer at pH 8. Once the TMSPM monomer concentration was optimized to yield a monolith with maximum test stability (robustness) and minimum back pressure, the monolith surface was modified by the grafting of tetramethyl orthosilicate (TMOS) for increased DNA binding capacity. After the examination of a variety of TMOS concentrations, 85% v/v TMOS was found to be optimal for DNA extraction without any obvious changes to the monolith structure. The reduction of time allowed for TMSPM hydrolysis prior to UV polymerization from 20 to 5 min led to a lower back pressure of the monolith, enabling better TMOS derivatization and therefore higher binding capacity. Minimal buffer volume (as low as 1 muL) was required to elute DNA from the solid phase, providing a DNA concentrating effect potentially important for downstream processes. While experimentation employed monolithic columns that were 12 cm in length, reduction of the length to 2 cm still allowed for a DNA binding capacity of at least 100 ng of prepurified human genomic DNA and extraction efficiencies greater than 85%. Extraction of low sample volumes (submicroliter) of human whole blood were successfully performed, with extraction efficiencies from the 2-cm monolithic column higher than those obtained from a commercial DNA extraction kit. These results position this novel matrix as an attractive alternative for solid-phase extraction of DNA and other biologically active molecules in microscale devices.

Blood↗

Use of a capillary electrophoresis instrument with laser-induced fluorescence detection for DNA quantitation. Comparison of YO-PRO-1 and PicoGreen assays.

Highly selective and sensitive assays are required for detection and quantitation of the small masses of DNA typically encountered in clinical and forensic settings. High detection sensitivity is achieved using fluorescent labeling dyes and detection techniques such as spectrofluorometers, microplate readers and cytometers. This work describes the use of a laser-induced fluorescence (LIF) detector in conjunction with a commercial capillary electrophoresis instrument for DNA quantitation. PicoGreen and YO-PRO-1, two fluorescent DNA labeling dyes, were used to assess the potential of the system for routine DNA analysis. Linearity, reproducibility, sensitivity, limits of detection and quantitation, and sample stability were examined for the two assays. The LIF detector response was found to be linear (R2 > 0.999) and reproducible (RSD < 9%) in both cases. The PicoGreen assay displayed lower limits of detection and quantitation (20 pg and 60 pg, respectively) than the YO-PRO-1 assay (60 pg and 260 pg, respectively). Although a small variation in fluorescence was observed for the DNA/dye complexes over time, quantitation was not significantly affected and the solutions were found to be relatively stable for 80 min. The advantages of the technique include a 4- to 40-fold reduction in the volume of sample required compared to traditional assays, a 2- to 20-fold reduction in the volume of reagents consumed, fast and automated analysis, and low cost (no specific instrumentation required).

Benzoxazoles↗

Method for determining intracapillary solution temperatures: application to sample zone heating for enhanced fluorescent labeling of proteins.

A fundamental premise in CE relies heavily on the assumption that temperature within the capillary is accurately known and controlled. Theoretical calculations for sample zone and BGE temperature during voltage application are presented. We propose that transient elevation of the sample zone temperature allowed for denaturing and renaturing of proteins in the presence of a fluorescent dynamic labeling reagent. Comparison with the extent of labeling possible with standard on-column dynamic labeling in the absence of elevated temperatures showed order-of-magnitude increases in the fluorescence detection sensitivity of proteins with low surface hydrophobicity. As a result, this represents an example where excess heating in the sample zone during electrophoresis can be exploited advantageously.

Electrophoresis, Capillary↗

Microchip-based cell lysis and DNA extraction from sperm cells for application to forensic analysis.

The current backlog of casework is among the most significant challenges facing crime laboratories at this time. While the development of next-generation microchip-based technology for expedited forensic casework analysis offers one solution to this problem, this will require the adaptation of manual, large-volume, benchtop chemistry to small volume microfluidic devices. Analysis of evidentiary materials from rape kits where semen or sperm cells are commonly found represents a unique set of challenges for on-chip cell lysis and DNA extraction that must be addressed for successful application. The work presented here details the development of a microdevice capable of DNA extraction directly from sperm cells for application to the analysis of sexual assault evidence. A variety of chemical lysing agents are assessed for inclusion in the extraction protocol and a method for DNA purification from sperm cells is described. Suitability of the extracted DNA for short tandem repeat (STR) analysis is assessed and genetic profiles shown. Finally, on-chip cell lysis methods are evaluated, with results from fluorescence visualization of cell rupture and DNA extraction from an integrated cell lysis and purification with subsequent STR amplification presented. A method for on-chip cell lysis and DNA purification is described, with considerations toward inclusion in an integrated microdevice capable of both differential cell sorting and DNA extraction. The results of this work demonstrate the feasibility of incorporating microchip-based cell lysis and DNA extraction into forensic casework analysis.

Buffers↗

Enhanced elution of sperm from cotton swabs via enzymatic digestion for rape kit analysis.

This report describes development of a method for enhanced cell elution from cotton swabs. The method exploits an enzyme mixture for digestion of the cotton to remove intact cells, and can be utilized in conjunction with or to circumvent conventional differential extraction (DE). Samples digested with Aspergillus niger cellulase yielded sperm cell recoveries (18+/-3.5%) similar to conventional DE buffer (23+/-7.8%) while providing intact epithelial cells. Storage time affected the concentration of enzyme required for optimal sperm cell recovery, with longer times requiring increased cellulase concentrations. Cellulase from A. niger yielded a twofold enhancement in sperm cell elution over buffer alone, and preliminary testing of higher activity cellulases from Trichoderma reesei and Trichoderma viride showed even greater enhancement. These results indicate that cellulose-digesting enzymes enhance the release of sperm and epithelial cells from a cotton swab over buffer alone, providing for efficient DNA analysis.

Aspergillus niger↗

Rapid DNA amplification in glass microdevices.

The polymerase chain reaction (PCR) for amplification of DNA has become a very useful tool in scientific research and analytical laboratories, yet conventional techniques are time-consuming, and the reagents are expensive. Miniaturization of this technique has the potential to drastically reduce amplification time and reagent consumption while simultaneously improving the efficiency of the reaction. Increasing the surface area-to-volume ratio using microfluidic reaction chambers allows homogeneous solution temperatures to be achieved much more rapidly than in conventional heating blocks. Employing infrared radiation to selectively heat the reaction solution can additionally reduce the time and energy needed for thermocycling; the reaction container is not heated and can even serve as a heat sink for enhancement of cooling. Microchip systems also provide the potential for fabrication of structures for additional processing steps directly in line with the PCR chamber. Not only can amplification be integrated with product separation and analysis, but sample preparation steps can also be incorporated prior to amplification. The ultimate goal is a miniature total-analysis-system with seamlessly coupled sample-in/answer-out capabilities that consumes very low volumes of reagents and drastically reduces the time for analysis. This chapter will focus on the materials and methods involved in simple straight-channel microchip PCR on glass substrates using non-contact thermocycling.

Bacterial Proteins↗

Pressure injection on a valved microdevice for electrophoretic analysis of submicroliter samples.

A recent report describes a reversible valve that can be used in series to achieve diaphragm pumping on chip (Grover, W. H.; Skelley, A. M.; Liu, C. N.; Lagally, E. T.; and Mathies, R. A. Sens. Actuators, B 2003, 89, 315-323). Here, the functionality of an integrated diaphragm pump on a hybrid PDMS-glass microchip to perform pressure injections for electrophoretic separations is demonstrated. A chip design that can perform both pressure and electrokinetic (EK) injection is described, and a mixture of fluorescein and ROX dyes in borate buffer is utilized as a model sample system. Multiple electrophoretic separations of sample injected with pressure and voltage are compared. Over multiple EK injections, an electrophoretic bias is observed and the injected analytes are not representative of the sample, with the peak area ratio changing 20% after 20 runs. Over multiple pressure injections, however, the sample composition is maintained, with a 3.6% CV over 20 runs. The data presented show the ability to alternate between injection types and pressure-inject a representative sample volume after a bias has already been observed with multiple EK injections. Multiple pressure injections have been performed on sample volumes as low as 500 nL while maintaining sample composition, supporting its use in integrated systems for small-volume sampling.

Electrochemistry↗

Glass microfluidic devices with thin membrane voltage junctions for electrospray mass spectrometry.

In this study a novel glass membrane was prepared for conducting high voltage (HV) to solution in the channel of a microfabricated device for generation of liquid electrospray. Taylor cone formation and mass spectra obtained from this microdevice confirmed the utility of the glass membrane, but voltage conduction through the membrane could not be successfully explained based solely on the conductivity of the glass itself. This novel method for developing a high-voltage interface for microdevices avoids direct metal/liquid contact eliminating bubble formation in the channel due to water hydrolysis on the surface of the metal. Further, this arrangement produces no dead volume as is often found with traditional liquid junctions. At the same time, preliminary investigations into the outlet design of glass microdevices for interfacing with electrospray mass spectrometry, was explored. Both the exit shape and the use of hydrophobic coatings at the channel exit of the microdevice electrospray interface were evaluated using standard proteins with results indicating the utility of this type of design after further optimization.

Equipment Design↗

Extrinsic Fabry-Perot interferometry for noncontact temperature control of nanoliter-volume enzymatic reactions in glass microchips.

Optical fiber extrinsic Fabry-Perot interferometry (EFPI) was investigated as a noncontact temperature sensor and utilized for regulating the temperature of small-volume solutions in microchips. Interference pattern analysis determined the optical path lengths (OPL) associated with reflections from various surfaces on or in the microchip, in particular, from gold sputtered on the bottom of a microchannel. Since OPL is directly proportional to refractive index, which is dependent on solution temperature, the EFPI sensor was capable of noncontact monitoring of solution temperature simply from alterations in the measured path length. Calibration of the sensor against a thermocouple was performed while heating the microchip in a noncontact manner with an IR lamp. The combination of EFPI temperature sensor, IR-mediated heating, and air cooling allowed a fully noncontact system for small-volume temperature control in microchip structures, and its utility was illustrated by optimal digestion of DNA by a temperature-dependent restriction endonuclease in 320 nL. The functionality and simplicity of the microchip EFPI temperature sensor was enhanced by replacing the prebonding sputtered gold with a tunable, chemically plated semireflective silver coating created in situ after chip fabrication. This provided an 8-fold improvement in the lowest detectable temperature change (deltaT = 0.1 degrees C), facilitated primarily by enhanced reflection from both the bottom and top surfaces of the microchannel. This approach for controlling micro- and nanoscale reactions--with heating, cooling, and temperature control being carried out in a completely noncontact fashion--provides an accurate and sensitive method for executing chemical and biochemical reactions in microchips.

Biosensing Techniques↗

Separation of sperm and epithelial cells in a microfabricated device: potential application to forensic analysis of sexual assault evidence.

Forensic DNA analysis of sexual assault evidence requires separation of DNA from epithelial (victim) and sperm (perpetrator) cells. The conventional method used by crime laboratories, which is termed "differential extraction", is a time-consuming process. To supplant the conventional process, separation of sperm from a biological mixture containing epithelial cells has been demonstrated on a microfluidic device. This separation utilizes the differential physical properties of the cells that result in settling of the epithelial cells to the bottom of the inlet reservoir and subsequent adherence to the glass substrate. As a result, low flow rates can be used to separate the sperm cells from the epithelial cell-containing biological mixture. Following cell separation on the microdevice, DNA extraction, amplification, and separation were performed using conventional laboratory methods, showing that the cell separation product in the outlet reservoir was of male origin. The reported cell separation has the potential to impact the forensic DNA analysis backlog of sexual assault cases by circumventing the time-consuming conventional differential extraction procedure.

Cell Separation↗

Evaluation of sieving polymers for fast, reproducible electrophoretic analysis of short tandem repeats (STR) in capillaries.

Efficient capillary electrophoretic STR analysis requires rapid, reproducible and robust separation of DNA fragments with reasonable capillary longevity--this is currently accomplished using proprietary commercial polymeric sieving matrices specifically developed for this separation. These matrices, while effective, are costly and do not provide adequate resolution of STR DNA fragments in capillaries with shorter effective separation lengths, increasing the time required to accomplish the separation and minimizing the potential extrapolation to other miniaturized platforms. As the forensic community looks toward next generation microchip technology as a means of processing casework more rapidly, new sieving polymers need to be evaluated for utilization in this platform. The research presented here describes the assessment of commercially-available polymeric sieving matrices for STR analysis, with consideration given to feasibility of incorporation into a microdevice. Polymer composition, molecular weight, and concentration were evaluated, along with an assessment of the effects of buffer composition, separation temperature, and capillary length. These variables were evaluated individually or collectively on the ability to resolve STR DNA fragments and the reproducibility of the separations and the results compared to a proprietary commercial product. A 600,000 Da MW poly(ethylene oxide) (PEO) solution at a 3% (w/v) concentration was determined to be the most suitable matrix for these separations. This polymer, in coated capillaries, provided highly robust and reproducible separations, with near baseline resolution of fragments having single base differences. Reductions in the temperature of the separation, from 60 degrees C to 40 degrees C, and the urea concentration of the buffer, from 7 M to 3.5 M, provided increased longevity of the PEO polymer for repeated separations. Comparison of this polymer with currently specified commercial products used for STR analysis showed that the optimized PEO matrix provided superior separations under all conditions tested. In addition, PEO could be utilized in shorter capillary systems, with a concurrent decrease in analysis time, highlighting its potential for use in shortened capillary or microdevice systems.

Buffers↗

Microchip laser-induced fluorescence detection of proteins at submicrogram per milliliter levels mediated by dynamic labeling under pseudonative conditions.

We have previously demonstrated on-column dynamic labeling of protein-SDS complexes on capillaries and microchips for laser-induced fluorescence (LIF) detection using both a commercially available fluor and a protein separation buffer. Upon binding to hydrophobic moieties (of the analyte or separation buffer), the fluor undergoes a conformational change allowing fluorescence detection at 590 nm following excitation with 488-nm light. Our original work showed on-chip limits of detection (LOD) comparable with those using UV detection (1 x 10(-5) M) on capillaries-falling significantly short of the detection limits expected for LIF. This was largely a function of the physicochemical characteristics of the separation buffer components, which provided significant background fluorescence. Having defined the contributing factors involved, a new separation buffer was produced which reduced the background fluorescence and, consequently, increased the available dye for binding to protein-SDS complexes, improving the sensitivity in both capillaries and microchips by at least 2 orders of magnitude. The outcome is a rapid, sensitive method for protein sizing and quantitation applicable to both capillary and microchip separations with a LOD of 500 ng/mL for bovine serum albumin. Interestingly, sensitivity on microdevices was improved by inclusion of the dye in the sample matrix, while addition of dye to samples in conventional CE resulted in a drastic reduction in sensitivity and resolution. This can be explained by the differences in the injection schemes used in the two systems. The linear range for protein quantitation covered at least 2 orders of magnitude in microchip applications. On-chip analysis of human sera allowed abnormalities, specifically the presence of elevated levels of gamma-globulins, to be determined.

Blood Proteins↗

Capillary electrophoresis with laser-induced fluorescence detection for laboratory diagnosis of galactosemia.

Galactosemia, a metabolic disorder associated with the intolerance to dietary galactose due to an inherited enzymatic deficiency, is indicated by heightened levels of galactose in urine (galactosuria). In this report, capillary electrophoresis (CE) with laser-induced fluorescence detection was evaluated for its ability to screen urinary carbohydrates, particularly galactose. Neonatal urine samples with normal and abnormal levels of galactose were analyzed with galactose concentrations quantitated relative to urinary creatinine concentrations to account for variable urinary dilution. Analysis of nine samples by CE in a single-blind manner defined four as negative (normal) and five as positive for galactosuria with galactose levels as high as 146.8 +/- 5.9 mM. Galactosuria was correlated with clinical galactosemia diagnoses for four of the positive samples, while the remaining positive was associated with a patient diagnosed with Hurler's syndrome.

Electrophoresis, Capillary↗