Search PubMed⌕ Search

Biomedical subjects

Jeremy D Hubert

Publications and source records attributed to Jeremy D Hubert.

10 recordsLinked to original sources

Evaluation of a vessel-sealing device for laparoscopic granulosa cell tumor removal in standing mares.

OBJECTIVE: To describe a laparoscopic technique for granulosa cell tumor removal using a vessel sealing device (LigaSuretrade mark) in standing mares. STUDY DESIGN: Retrospective study. ANIMALS: Eight mares (8-24 years old; weighing, 406-525 kg). METHODS: Before surgery, ovarian size and adjacent body wall thickness was determined by ultrasonography. Mares were sedated and after local anesthesia (inverted L and local infiltration), laparoscopic cannulation was performed without insufflation. The mesovarium was anesthetized and the LigaSure instrument applied to the mesovarium for hemostasis and resection to remove the affected ovary. Mares were hospitalized for 24 hours before discharge. RESULTS: Median ovarian diameter was 10.5 cm (range, 6-14 cm). Median surgery time was 75 minutes (range, 40-180 minutes). Hemostasis was achieved using the LigaSure device in all mares. Median length of the abdominal wall incision made to remove the ovary was 13 cm (range, 5-17 cm); no incisional complications occurred. CONCLUSIONS: The LigaSure vessel sealing device provided adequate hemostasis for removal of larger neoplastic ovaries in standing mares. CLINICAL RELEVANCE: Concerns of ligature placement can be alleviated by use of the LigaSure device and standing laparoscopic technique provides excellent observation of the surgical field ensuring hemostasis.

Animals↗

An in vitro biomechanical comparison between prototype tapered shaft cortical bone screws and AO cortical bone screws for an equine metacarpal dynamic compression plate fixation of osteotomized equine third metacarpal bones.

OBJECTIVES: To compare biomechanical properties of a prototype 5.5 mm tapered shaft cortical screw (TSS) and 5.5 mm AO cortical screw for an equine third metacarpal dynamic compression plate (EM-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: Paired in vitro biomechanical testing of cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Adult equine cadaveric MC3 bones (n=12 pairs). METHODS: Twelve pairs of equine MC3 were divided into 3 groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of each, mid-diaphyseal osteotomized, MC3 pair. For each MC3 bone pair, 1 was randomly chosen to have the EM-DCP secured with four 5.5 mm TSS (2 screws proximal and distal to the osteotomy; TSS construct), two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws in the remaining holes. The control construct (AO construct) had four 5.5 mm AO cortical screws to secure the EM-DCP in the 2 holes proximal and distal to the osteotomy in the contralateral bone from each pair. The remaining holes of the EM-DCP were filled with two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws. All plates and screws were applied using standard AO/ASIF techniques. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the TSS construct were significantly greater (P<.00004 for yield and P<.00001 for failure loads) than those of the AO construct. Mean cycles to failure in 4-point bending of the TSS construct was significantly greater (P<.0002) than that of the AO construct. The mean yield load and composite rigidity in torsion of the TSS construct were significantly greater (P<.0039 and P<.00003, respectively) than that of the AO construct. CONCLUSION: The TSS construct provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: The results of this in vitro study support the conclusion that the EM-DCP fixation using the prototype 5.5 mm TSS is biomechanically superior to the EM-DCP fixation using 5.5 mm AO cortical screws for the stabilization of osteotomized equine MC3.

Animals↗

Determination of functional and morphologic changes in palmar digital nerves after nonfocused extracorporeal shock wave treatment in horses.

OBJECTIVE: To determine functional and morphologic changes in palmar digital nerves after nonfocused extracorporeal shock wave (ESW) treatment in horses. ANIMALS: 6 horses. PROCEDURES: The medial and lateral palmar digital nerves of the left forelimb were treated with nonfocused ESWs. The medial palmar digital nerve of the right forelimb served as a nontreated control nerve. At 3, 7, and 35 days after treatment, respectively, 2 horses each were anesthetized and nerves were surgically exposed. Sensory nerve conduction velocities (SNCVs) of treated and control nerves were recorded, after which palmar digital neurectomies were performed. Morphologic changes in nerves were assessed via transmission electron microscopy. RESULTS: Significantly lower SNCV in treated medial and lateral nerves, compared with control nerves, was found 3 and 7 days after treatment. A significantly lower SNCV was detected in treated medial but not lateral nerves 35 days after treatment. Transmission electron microscopy of treated nerves revealed disruption of the myelin sheath with no evidence of damage to Schwann cell bodies or axons, 3, 7, and 35 days after treatment. CONCLUSIONS AND CLINICAL RELEVANCE: Nonfocused ESW treatment of the metacarpophalangeal area resulted in lower SNCV in palmar digital nerves. This effect likely contributes to the post-treatment analgesia observed in horses and may result in altered peripheral pain perception. Horses with preexisting lesions may be at greater risk of sustaining catastrophic injuries when exercised after treatment.

Analgesia↗

Clinical signs and hematologic, cytokine, and plasma nitric oxide alterations in response to Strongylus vulgaris infection in helminth-naïve ponies.

The objective of this study was to determine the effect of infection with Strongylus vulgaris on serum cytokines and plasma nitric oxide (NO) concentrations in helminth-naive ponies. Group 1 (n = 21) was given 500 S. vulgaris L3 larvae and group 2 (n = 7) received a saline control. Ponies were monitored daily for clinical signs, and blood was collected for complete blood cell counts and serum cytokines (TNF, IL-1, IL-6) quantification. Group 1 ponies were depressed, anorexic, and febrile for variable periods of time. Plasma NO was increased on day 21 in group 1 and on days 9 and 21 in group 2. Significant increases in total white blood cell counts, fibrinogen, and plasma protein concentrations in group 1 were found. Significant decreases in red blood cell counts and packed cell volume were also noted in group 1. There were no differences in serum cytokines across time in either group of ponies. Despite the lack of proinflammatory cytokine induction with the apparent inflammatory response to S. vulgaris there is evidence of a potential role of NO.

Animals↗

Evaluation of cutaneous analgesia after non-focused extracorporeal shock wave application over the 3rd metacarpal bone in horses.

Extracorporeal shock wave therapy is becoming increasingly used in equine practice to treat musculoskeletal disorders. Although the exact effects of extracorporeal shock waves on tissues still need to be elucidated, transient cutaneous analgesia has been observed within treated areas in humans and horses. The purpose of this study was to determine the onset, magnitude, and duration of cutaneous analgesia after non-focused extracorporeal shock wave (ESW) application by comparing the limb withdrawal reflex latency (LWRL) in treated and untreated areas on the metacarpus of horses, using a focused light source. A single treatment with non-focused ESW was applied to 3 areas over the dorsal aspect of one metacarpus in 12 horses. The LWRL was measured to assess cutaneous sensation in treated and untreated control areas of the treated metacarpus and in an untreated area on the opposite metacarpus, before and at various time points after ESW application. Most treated and control areas revealed a significant decrease in LWRL over time compared with baseline values. Although the results of our study do not suggest cutaneous analgesia after ESW application to the equine metacarpus, we advise cautious use of this treatment modality for horses in training or before competition until further research is done.

Analgesia↗

Temporal effects of freezing on plasma nitric oxide concentrations in ponies.

The purpose of this study was to compare concentrations of nitric oxide (NO) in fresh plasma versus frozen plasma, and determine the temporal effects of freezing on jugular venous plasma NO concentrations in clinically healthy ponies. Twenty-eight helminth-naive ponies, aged from 4 to 6 mo, were raised and maintained under parasite-free conditions. Blood was collected from the jugular vein, centrifuged, and the plasma supernatant was analyzed fresh for NO concentrations using a chemiluminescent method. The remaining samples were aliquoted into 12 samples and stored at -70 degrees C until they were analyzed for NO concentration. Plasma NO concentration was measured at monthly intervals for 12 mo. There were significant differences in the plasma NO concentration across time compared with the baseline value at 1, 3, 4, 6, 7, and 11 mo. However, these values remained within the range for clinically healthy equids compared with concentrations of NO from horses with increased NO from diseased states.

Animals↗

Equine anhidrosis.

The molecular basis of the pathophysiology of anhidrosis is still not well understood. Therefore, treatments are more often based on clinical impressions than on scientific fact. Treatment options for this condition will improve only when more is known about the molecular events that cause anhidrosis, especially as they relate to beta2-receptor dysfunction and stimulus-secretion coupling in the sweat glands of affected horses. Although this additional information is being attained, sound environmental management will continue to be a very important aspect of the treatment of horses affected with anhidrosis.

Animals↗

An in vitro evaluation of plate luting using osteotomized equine third metacarpal bones with a limited contact-dynamic compression plate.

OBJECTIVES: To evaluate the effects of plate luting on the biomechanical properties of a broad limited contact-dynamic compression plate (LC-DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by LC-DCP fixation, with 1 of the pair luted with polymethylmethacrylate (PMMA). ANIMAL POPULATION: Ten pairs of adult equine cadaveric MC3 bones. METHODS: Ten pairs of equine MC3 were divided into 2 test groups (5 pairs each) for (1) palmarodorsal 4-point bending single cycle to failure testing and (2) palmarodorsal 4-point bending cyclic fatigue testing. The LC-DCP (8 hole, 4.5 mm) was applied to the dorsal surface of each pair of MC3 bones. All plates and screws were applied using standard AO/ASIF techniques. All MC3 bones had mid-diaphyseal osteotomies. One of the matched pairs of LC-DCP-MC3 constructs were randomly chosen to be luted with PMMA. Mean test variable values for each method were compared using a paired t-test within each group; significance was set at P<.05. RESULTS: Mean palmarodorsal 4-point bending yield bending moment, failure bending moment of the LC-DCP fixation with luting was not significantly different (P>.05) than those of the LC-DCP fixation without luting. Mean cycles to failure for palmarodorsal 4-point bending was significantly (P<.0003) greater, with a 7.2-fold increase, for the LC-DCP fixation with luting compared with the LC-DCP fixation without luting. CONCLUSION: Luting the broad LC-DCP with PMMA in the fixation osteotomized equine MC3 bones increases the fatigue life of cyclic loading for palmarodorsal 4-point bending under the in vitro conditions studied. CLINICAL RELEVANCE: The cyclic fatigue data supports the conclusion that luted broad LC-DCP fixation is biomechanically superior to the non-luted broad LC-DCP fixation in osteotomized equine MC3 bones.

Animals↗

An in vitro biomechanical comparison of a limited-contact dynamic compression plate fixation with a dynamic compression plate fixation of osteotomized equine third metacarpal bones.

OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation. CONCLUSION: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing. CLINICAL RELEVANCE: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.

Animals↗

An in vitro biomechanical comparison of a prototype equine metacarpal dynamic compression plate fixation with double dynamic compression plate fixation of osteotomized equine third metacarpal bones.

OBJECTIVES: To compare the monotonic biomechanical properties of a prototype equine third metacarpal dynamic compression plate (EM-DCP) fixation with a double broad dynamic compression plate (DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional testing. The EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of one randomly selected bone from each pair. Two DCPs, 1 dorsally (10-hole, 4.5 mm broad) and 1 laterally (9-hole, 4.5 mm broad) were applied to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the EM-DCP fixation were significantly greater (P<.0001) than those of the double broad DCP fixation. Mean cycles to failure in 4-point bending of the EM-DCP fixation was significantly greater (P<.0008) than that of the double broad DCP fixation. Mean yield load, composite rigidity, and failure load in torsion of the EM-DCP fixation were significantly greater (P<.0035) than that of the double broad DCP fixation. CONCLUSION: The EM-DCP provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: Results of this in vitro study support the conclusion that the prototype EM-DCP fixation is biomechanically superior to the double broad DCP fixation for the stabilization of osteotomized equine MC3.

Animals↗