A soft deformable tissue-equivalent phantom for diffuse optical tomography.

A recipe is presented for the manufacture of highly compressible phantoms for diffuse optical tomography. The recipe is based on polyvinyl alcohol (PVA) slime, a viscoelastic fluid which readily deforms under moderate pressure. Scattering particles and absorbing compounds can be added to provide a uniform material with stable and reproducible optical properties. A linear relationship between the concentration of scattering particles (either titanium dioxide or microspheres) and the transport scatter coefficient is demonstrated. Phantoms of an arbitrary size and shape may be produced by containing the slime within a thin latex shell, and a stability over a period of at least 3 months has been established. The deformable phantoms may be used to test and calibrate optical tomography systems designed for use on patients with irregular or variable geometries.

Absorption↗

Linear and nonlinear reconstruction for optical tomography of phantoms with nonscattering regions.

Most research in optical imaging incorrectly assumes that light transport in nonscattering regions in the head may be modeled by use of the diffusion approximation. The effect of this assumption is examined in a series of experiments on tissue-equivalent phantoms. Images from cylindrical and head-shaped phantoms with and without clear regions [simulating the cerebrospinal fluid (CSF) filled ventricles] and a clear layer (simulating the CSF layer surrounding the brain) are reconstructed with linear and nonlinear reconstruction techniques. The results suggest that absorbing and scattering perturbations can be identified reliably with nonlinear reconstruction methods when the clear regions are also present in the reference data but that the quality of the image degrades considerably if the reference data does not contain these features. Linear reconstruction performs similarly to nonlinear reconstruction, provided the clear regions are present in the reference data, but otherwise linear reconstruction fails. This study supports the use of linear reconstruction for dynamic imaging but suggests that, in all cases, image quality is likely to improve if the clear regions are modeled correctly.

Algorithms↗

Optical tomography of the breast using a multi-channel time-resolved imager.

A time-resolved optical tomography system has been used to generate cross-sectional images of the human breast. Images are reconstructed using an iterative, nonlinear algorithm and measurements of mean photon flight time relative to those acquired on a homogeneous reference phantom. Thirty-eight studies have been performed on three healthy volunteers and 21 patients with a variety of breast lesions including cancer. We have successfully detected 17 out of 19 lesions, and shown that optical images of the healthy breast of the same volunteer display a heterogeneity which is repeatable over a period of months. However, results also indicate that the lack of accurate quantitation of optical parameters and limited morphological information limits the ability to characterize different types of lesions and distinguish benign from malignant tissues. Drawbacks of our current methodology and plans for overcoming them are discussed.

Adult↗

Monitoring recovery after laser surgery of the breast with optical tomography: a case study.

Results are presented of a study to monitor the changes in the optical properties of breast tissue over a 12-month period after interstitial laser photocoagulation treatment of a fibroadenoma. The study involved generating cross-sectional images of the breast with a multichannel time-resolved imaging system and a nonlinear image reconstruction algorithm. Images of the internal absorbing and scattering properties revealed the expected initial inflammatory response, followed by the development of low-scattering cysts consistent with corresponding ultrasound examinations. Although results indicate that purely qualitative images can potentially provide clinically valuable data, means of enhancing diagnostic information by overcoming present limitations of the approach are discussed.

Adult↗

Experimental evaluation of an anisotropic scattering model of a slab geometry.

A model has been developed based on random walk theory that allows the diffusion of light along a principal axis to differ from that in orthogonal directions. We present expressions that describe the time-resolved intensity measured across a slab and on the surface of a semi-infinite medium for a principal axis oriented parallel or perpendicular to the surface. The model of time-resolved transmittance is compared with experimental data acquired by use of a phantom consisting of wax fibers arranged within a solid cube of resin. It is shown that a single set of optical parameters is sufficient to model the experimental measurements acquired across all three orientations of the cube.

Algorithms↗

Imaging changes in blood volume and oxygenation in the newborn infant brain using three-dimensional optical tomography.

Induced haemodynamic and blood oxygenation changes occurring within the brain of a ventilated newborn infant have been imaged in three dimensions using optical tomography. Noninvasive measurements of the flight times of transmitted light were acquired during illumination of the brain by laser pulses at wavelengths of 780 nm and 815 nm. The oxygen and carbon dioxide partial pressures were adjusted through alterations to the ventilator settings, resulting in changes to the cerebral blood volume and oxygenation. Three-dimensional images were generated using the physiologically associated differences in the measured data, obviating the need for data calibration using a separate reference measurement. The results exhibit large changes in absorption coefficient at both wavelengths. Images corresponding to differences in concentrations of oxy- and deoxyhaemoglobin are in qualitative agreement with known physiological data.

Blood Flow Velocity↗

Optical tomography of a realistic neonatal head phantom.

We have begun clinical trials of optical tomography of the neonatal brain. To validate this research, we have built and imaged an anatomically realistic, tissue-equivalent neonatal head phantom that is hollow, allowing contrasting objects to be placed inside it. Images were reconstructed by use of two finite-element meshes, one generated from a computed tomography image of the phantom and the other spherical. The phantom was filled with a liquid of the same optical properties as the outer region, and two perturbations were placed inside. These were successfully imaged with good separation between the absorption and scatter coefficients. The phantom was then refilled with a liquid of increased absorption compared with the background to simulate the brain, and the absolute properties of the two regions were found. These were used as a priori information for the complete reconstruction. Both perturbations were visible, superimposed on the increased absorption of the central region. The head-shaped mesh performed slightly better than the spherical mesh, particularly when the absorption of the central region of the phantom was increased.

Head↗

Advances in optical imaging of the newborn infant brain.

New methods of imaging the oxygenation, hemodynamics, and metabolism of the newborn infant brain are being developed, based on illumination of the head with near-infrared light. Techniques known as optical topography and optical tomography have the potential to provide valuable information about the function of the normal brain, and about a variety of cerebral pathology such as hypoxic-ischemia. Optical methods provide a unique means of monitoring brain oxygenation safely in an intensive care environment without interference with the normal handling of the infant. Studies on infants have focused on the assessment of steady-state regional cerebral perfusion and tissue oxygenation, as well as monitoring hemodynamic changes in response to sensory stimulation. Recent technological and methodological advances in this research field are reviewed, and the likely impact of optical imaging methods on the care of newborn infants is assessed.

Brain↗

Assessment of an in situ temporal calibration method for time-resolved optical tomography.

A 32-channel time-resolved optical imaging device is developed at University College London to produce functional images of the neonatal brain and the female breast. Reconstruction of images using time-resolved measurements of transmitted light requires careful calibration of the temporal characteristics of the measurement system. Since they can often vary over a period of time, it is desirable to evaluate these characteristics immediately after, or prior to, the acquisition of image data. A calibration technique is investigated that is based on the measurement of light back-reflected from the surface of the object being imaged. This is facilitated by coupling each detector channel with an individual source fiber. A Monte Carlo model is employed to investigate the influence of the optical properties of the object on the back-reflected signal. The results of simulations indicate that their influence may be small enough to be ignored in some cases, or could be largely accounted for by a small adjustment to the calibrated data. The effectiveness of the method is briefly demonstrated by imaging a solid object with tissue-equivalent optical properties.

Brain↗

Validity conditions for the radiative transfer equation.

We compare the radiative transfer equation for media with constant refractive index with the radiative transfer equation for media with spatially varying refractive indices [J. Opt. A Pure App. Opt. 1, L1 (1999)] and obtain approximate conditions under which the former equation is accurate for modeling light propagation in scattering media with spatially varying refractive indices. These conditions impose restrictions on the variations of the refractive index, the gradient of the refractive index, the divergence of the rays, the frequency of modulation, and the widths of light pulses, which are related to the mean refractive index, the absorption coefficient, and the reduced scattering coefficient of the medium. Each condition is geometrically interpreted. Some implications of the results are discussed.

Light↗

Three-dimensional optical tomography of the premature infant brain.

For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have been reconstructed using measurements of mean flight time relative to those acquired on a homogeneous reference phantom, and using a head-shaped 3D finite-element-based forward model with an external boundary constrained to match the measured positions of the sources and detectors. Results are presented for a premature infant with a cerebral haemorrhage predominantly located within the left ventricle. Images representing the distribution of absorption at 780 nm and 815 nm reveal an asymmetry consistent with the haemorrhage, and corresponding maps of blood volume and fractional oxygen saturation are generally within expected physiological values.

Brain↗

Time-resolved optical mammography using a liquid coupled interface.

A method has been devised for generating three-dimensional optical images of the breast using a 32-channel time-resolved system and a liquid-coupled interface. The breast is placed in a hemispherical cup surrounded by sources and detectors, and the remaining space is filled with a fluid with tissue-like optical properties. This approach has three significant benefits. First, cups can accommodate a large range of breast sizes, enabling the entire volume of the breast to be sampled. Second, the coupling of the source and detector optics at the surface is constant and independent of the subject, enabling intensity measurements to be employed in the image reconstruction. Third, the external geometry of the reconstructed volume is known exactly. Images of isolated targets with contrasting absorbing and scattering properties have been acquired, and the performance of the system has been evaluated in terms of the contrast, spatial resolution, and localization accuracy. These parameters were strongly dependent on the location of the targets within the imaged volume. Preliminary images of a healthy human subject are also presented, which reveal subtle heterogeneity, particularly in the distribution of scatter. The ability to detect an absorbing target adjacent to the breast is also demonstrated.

Breast↗

Comparison between a time-domain and a frequency-domain system for optical tomography.

The quality of phase and amplitude data from two medical optical tomography systems were compared. The two systems are a 32-channel time-domain system developed at University College London (UCL) and a 16-channel frequency-domain system developed at Helsinki University of Technology (HUT). Difference data measured from an inhomogeneous and a homogeneous phantom were compared with a finite-element method (diffusion equation) and images of scattering and absorption were reconstructed based on it. The measurements were performed at measurement times between 1 and 30 s per source. The mean rms errors in the data measured by the HUT system were 3.4% for amplitude and 0.51 deg for phase, while the corresponding values for the UCL data were 6.0% and 0.46 deg, respectively. The reproducibility of the data measured with the two systems was tested with a measurement time of 5 s per source. It was 0.4% in amplitude for the HUT system and 4% for the UCL system, and 0.08 deg in phase for both systems. The image quality of the reconstructions from the data measured with the two systems were compared with several quantitative criteria. In general a higher contrast was observed in the images calculated from the HUT data.

Algorithms↗