Search PubMed⌕ Search

Biomedical subjects

Jeffrey L Evelhoch

Publications and source records attributed to Jeffrey L Evelhoch.

6 recordsLinked to original sources

Dynamic contrast-enhanced magnetic resonance imaging as a pharmacodynamic measure of response after acute dosing of AG-013736, an oral angiogenesis inhibitor, in patients with advanced solid tumors: results from a phase I study.

PURPOSE: Identifying suitable markers of biologic activity is important when assessing novel compounds such as angiogenesis inhibitors to optimize the dose and schedule of therapy. Here we present the pharmacodynamic response to acute dosing of AG-013736 measured by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). PATIENTS AND METHODS: Thirty-six patients with advanced solid tumors were treated with various doses of AG-013736. In addition to standard measures of objective disease response and pharmacokinetic analysis, DCE-MRI scans were acquired at baseline and repeated at cycle 1--day 2 after the scheduled morning dose of the AG-013736 in 26 patients. Indicators of a vascular response, such as the volume transfer constant (K(trans)) and initial area under the curve (IAUC), were calculated to assess the effect of treatment on tumor vascular function. RESULTS: Evaluable vascular response data were obtained in 17 (65%) of 26 patients. A linear correlation was found in which the percentage change from baseline to day 2 in K(trans) and IAUC was inversely proportional to AG-013736 exposure. Using a conservative a priori assumption that a > or = 50% decrease in K(trans) was indicative of an objective vascular response, a 50% decrease in K(trans) was achieved and corresponded to a plasma AUC(0-24) of > 200 ng . h/mL. CONCLUSION: A sufficient decrease in tumor vascular parameters was observed at a dose chosen for additional phase II testing by conventional toxicity criteria. In addition, the day 2 vascular response measured using DCE-MRI seems to be a useful indicator of drug pharmacology, and additional research is needed to determine if it is a suitable marker for predicting clinical activity.

Administration, Oral↗

Accuracy and precision of quantitative assessment of cartilage morphology by magnetic resonance imaging at 3.0T.

OBJECTIVE: Quantitative magnetic resonance imaging (MRI) of articular cartilage represents a powerful tool in osteoarthritis (OA) research, but has so far been confined to a field strength of 1.5T. The aim of this study was to evaluate the precision of quantitative MRI assessments of human cartilage morphology at 3.0T and to correlate the measurements at 3.0T with validated measurements at 1.5T. METHODS: MR images of the knee of 15 participants with OA and 15 healthy control subjects were acquired using Siemens 1.5T and 3.0T scanners. Double oblique coronal scans were obtained at 1.5T with a 1.5-mm partition thickness, at 3.0T with a 1.5-mm partition thickness, and at 3.0T with a 1.0-mm partition thickness. Cartilage volume, thickness, and surface area of the femorotibial cartilage plates were quantified using proprietary software. RESULTS: For 1.5-mm partition thickness at 1.5T, the precision error was 3.0% and 2.6% for cartilage volume and cartilage thickness, respectively. The error was smaller for a 1.5-mm partition thickness at 3.0T (2.6% and 2.5%) and still smaller for a 1.0-mm partition thickness at 3.0T (2.1% and 2.0%). Correlation coefficients between values obtained at 3.0T and 1.5T were high (r > or = 0.96), with no significant deviation between the two field strengths. CONCLUSION: Quantitative MRI measurement of cartilage morphology at 3.0T (partition thickness 1 mm) was found to be accurate and tended to be more reproducible than at 1.5T (partition thickness 1.5 mm). Imaging at 3.0T may therefore provide superior ability to detect changes in cartilage status over time and to determine responses to treatment with structure-modifying drugs.

Aged↗

Defining the pHi-hyperthermia sensitivity relationship for the RIF-1 tumor in vivo: a 31P MR spectroscopy study.

This study quantifies the enhancement of the therapeutic efficacy of hyperthermia resulting from an acutely acidified and accurately monitored intracellular pH (pHi) in a mouse tumor model in vivo. Metabolic manipulation of the physiology of RIF-1 tumor (subcutaneous, on the hind flanks of female C3H/HeJ mice) achieved by i.p. bolus injection of glucose (glycolytic tumor acidification) or 3-O-methylglucose (non-glycolytic tumor acidification) was monitored by 31P magnetic resonance (31P MR) prior to, during and up to 1 h after localized hyperthermia. The pre-hyperthermia 31P MR-observable metabolic parameter that correlates most strongly with thermal sensitivity is pHi. Thermal sensitivity increases linearly with decreasing pHi regardless of the mechanism (glycolytic or non-glycolytic) of metabolic manipulation. The quantitative relationship is described by log10(SF)/EQ43=0.0079 pHi,preHT -0.0606 (R=0.63, P<0.0001), where EQ43 is the thermal heat dose delivered to the tumor (in units of equivalent minutes at 42.5 degrees C), pHi,preHT is the intracellular pH immediately prior to hyperthermia, and SF is the surviving fraction. The therapeutic enhancement is not as dramatic as expected based upon previously reported in vitro studies but is generally consistent with other in vivo studies. The method still represents a viable strategy for enhancing the therapeutic efficacy of hyperthermia, especially when used in combination with other therapeutic modalities.

3-O-Methylglucose↗

Magnetic resonance imaging measurements of the response of murine and human tumors to the vascular-targeting agent ZD6126.

PURPOSE: ZD6126 is a novel vascular targeting agent currently undergoing clinical evaluation. It acts by destabilizing the microtubulin of fragile and proliferating neoendothelial cells in tumors. The drug leads to blood vessel congestion, the selective destruction of the vasculature, and extensive necrosis in experimental tumors. The aim of the study reported here was to assess the ability of dynamic contrast enhanced magnetic resonance imaging (MRI) to measure the antivascular effects of ZD6126 in tumors. EXPERIMENTAL DESIGN: The work was carried out in mice bearing C38 colon adenocarcinoma and in patients with advanced cancers. MRI was performed before and 6 h (human tumors) or 24 h (C38 tumors) after i.v. drug administration. Contrast agent (gadolinium diethylenetriaminepentaacetate) enhancement was characterized by the initial area under the gadolinium diethylenetriaminepentaacetate uptake versus time curve (IAUC). IAUC reflects blood flow, vascular permeability, and the fraction of interstitial space. RESULTS: The median IAUC was reduced in all C38 tumors after ZD6126 administration [by 6-48% at 50 mg/kg (n = 3)], 58-91% at 100 mg/kg (n = 4), and 11-93% at 200 mg/kg (n = 6). In contrast, the administration of vehicle only led to no consistent change in median IAUC (n = 4). The ZD6126-induced changes in median IAUC appeared to be dose dependent (P = 0.045). No ZD6126-induced changes were apparent in murine muscle. Similar effects were seen in preliminary data from human tumors (11 tumors studied, 9 patients). At doses of 80 mg/m(2) and higher, the median IAUC post-ZD6126 treatment was reduced in all of the tumors studied (8 tumors, 6 patients) to 36-72% from the baseline value. There was a significant trend of increasing reductions with increasing exposure (P < 0.01). No drug-induced changes in human muscle or spleen IAUC were apparent. The reproducibility of the median IAUC parameter was investigated in patients. In 19 human tumors (measured in 19 patients) inter- and intratumor coefficients of variation were 64 and 18%. CONCLUSIONS: The contrast enhanced-MRI measured median IAUC is a useful end point for quantifying ZD6126 antivascular effects in human tumors.

Angiogenesis Inhibitors↗