Search PubMed⌕ Search

Biomedical subjects

Jean Gotman

Publications and source records attributed to Jean Gotman.

At least 37 records · Page 2Linked to original sources

Dipole modeling of epileptic spikes can be accurate or misleading.

PURPOSE: We investigated the accuracy and potential for serious error when representing cortical generators of epileptic spikes with the common single-dipole model. Spike generators were realistically simulated with cortical areas of different extents. METHODS: The source was simulated by using a patch that comprised small triangles on the cortical surface, each triangle having an elementary dipole generator with a moment corresponding to real intracerebral fields of spikes. The source-patch covered various clinically important parts of the temporal and frontal lobes, with an area ranging from 6 to 120 cm2. The scalp field was computed for each source-patch by using a realistic head model and was fitted by the single-dipole model to determine the best-fit dipole and the intracerebral distribution of residual variance (RV). Dipole modeling also was performed for the simulated scalp field with additional real EEG background. RESULTS: The RV after fitting a dipole to the scalp field without noise was at most 1.34%. Scalp spikes arising from sources of 6 cm2 were of small amplitude, and the dipoles estimated for these spikes were inconsistent. Extension of the source area was associated with increase of scalp potential amplitude, only very small increase of RV, and increased consistency of the estimated dipoles. When the source was very large, the dipoles clustered at very misleading locations. CONCLUSIONS: Pitfalls in dipole source localization are caused by the procedure of fitting the simplistic dipole model to real cortical sources with spatial extent and complex configuration.

Action Potentials↗

Removing eye-movement artifacts from the EEG during the intracarotid amobarbital procedure.

PURPOSE: The EEG is often recorded during the intracarotid amobarbital procedure (IAP) to help in the assessment of the spatial extent and the duration of the effect of the drug. In scalp recordings, the EEG is always heavily contaminated with eye movement artifacts as the patient actively performs visual tasks. METHODS: Independent component analysis (ICA) is a new technique for blind source separation. In this study, we separated the EEG data recorded during the IAP into independent components using ICA. The EEG signal was reconstructed by excluding the components related to eye movement and eye blinks. RESULTS: EEGs from 10 IAP tests were analyzed. The experimental results indicate that ICA is very efficient at subtracting eye-movement artifacts, while retaining the EEG slow waves and making their interpretation easier. CONCLUSIONS: ICA appears to be a generally applicable and effective method for removing ocular artifacts from EEG recordings during IAP, although slow waves and ocular artifacts share similar frequency distributions.

Algorithms↗

Analysis of the EEG-fMRI response to prolonged bursts of interictal epileptiform activity.

The use of combined EEG-fMRI to study interictal epileptiform activity is increasing and has great potential as a clinical tool, but the haemodynamic response to epileptiform activity remains incompletely characterised. To this end, 19 data sets from 14 patients with prolonged bursts of focal or generalised interictal epileptiform activity lasting up to 15 s were analysed. To determine whether the inclusion of the durations of the epileptic events in the general linear model resulted in increased statistical significance of activated regions, statistical maps were generated with and without the event durations. The mean differences when including the durations were a 14.5% increase in peak t value and a 29.5% increase in volume of activation. This suggests that when analysing EEG-fMRI data from patients with prolonged bursts of interictal epileptiform activity, it is better to include the event durations. To determine whether the amplitudes and latencies of the measured responses were consistent with the general linear model, the haemodynamic response functions for bursts of different durations were calculated and compared with the model predictions. The measured amplitude of the response to the shortest duration events was consistently larger than predicted, which is consistent with studies in normal subjects. For the two data sets with the widest range of event durations, the measured amplitudes increased with the durations of the events without evidence of the plateau that was expected from the general linear model. There were no consistent differences between the measured and modelled latencies.

Adolescent↗

EEG-fMRI of focal epileptic spikes: analysis with multiple haemodynamic functions and comparison with gadolinium-enhanced MR angiograms.

Combined EEG-fMRI has recently been used to explore the BOLD responses to interictal epileptiform discharges. This study examines whether misspecification of the form of the haemodynamic response function (HRF) results in significant fMRI responses being missed in the statistical analysis. EEG-fMRI data from 31 patients with focal epilepsy were analysed with four HRFs peaking from 3 to 9 sec after each interictal event, in addition to a standard HRF that peaked after 5.4 sec. In four patients, fMRI responses were correlated with gadolinium-enhanced MR angiograms and with EEG data from intracranial electrodes. In an attempt to understand the absence of BOLD responses in a significant group of patients, the degree of signal loss occurring as a result of magnetic field inhomogeneities was compared with the detected fMRI responses in ten patients with temporal lobe spikes. Using multiple HRFs resulted in an increased percentage of data sets with significant fMRI activations, from 45% when using the standard HRF alone, to 62.5%. The standard HRF was good at detecting positive BOLD responses, but less appropriate for negative BOLD responses, the majority of which were more accurately modelled by an HRF that peaked later than the standard. Co-registration of statistical maps with gadolinium-enhanced MRIs suggested that the detected fMRI responses were not in general related to large veins. Signal loss in the temporal lobes seemed to be an important factor in 7 of 12 patients who did not show fMRI activations with any of the HRFs.

Artifacts↗

Quantitative visualization of ictal subdural EEG changes in children with neocortical focal seizures.

OBJECTIVE: To quantify the ictal subdural electroencephalogram (EEG) changes using spectral analysis, and to delineate the quantitatively defined ictal onset zones on high-resolution 3D MR images in children with intractable neocortical epilepsy. METHODS: Fourteen children with intractable neocortical epilepsy (age: 1-16 years) who had subsequent resective surgery were retrospectively studied. The subjects underwent a high-resolution MRI and prolonged subdural EEG recording. Spectral analysis was applied to 3 habitual focal seizures. After fast Fourier transformation of the EEG epoch at ictal onset, an amplitude spectral curve (square root of the power spectral curve) was created for each electrode. The EEG magnitude of ictal rhythmic discharges was defined as the area under the amplitude spectral curve within a preset frequency band including the ictal discharge frequency, and calculated for each electrode. The topography mapping of ictal EEG magnitude was subsequently displayed on a surface-rendered MRI. Finally, receiver operating characteristic (ROC) analysis was performed to evaluate the consistency between quantitatively and visually defined ictal onset zones. RESULTS: The electrode showing the maximum of the averaged ictal EEG magnitude was part of the visually defined ictal onset zone in all cases. ROC analyses demonstrated that electrodes showing >30% of the maximum of the averaged ictal EEG magnitude had a specificity of 0.90 and a sensitivity of 0.74 for the concordance with visually defined ictal onset zones. SIGNIFICANCE: Quantitative ictal subdural EEG analysis using spectral analysis may supplement conventional visual inspection in children with neocortical epilepsy by providing an objective definition of the onset zone and its simple visualization on the patient's MRI.

Adolescent↗

Using patient-specific hemodynamic response functions in combined EEG-fMRI studies in epilepsy.

Combining electroencephalogram (EEG) and functional MRI (fMRI) allows localization of brain regions activated as a result of epileptic spikes. The statistical analysis of fMRI data usually includes a standard model of the hemodynamic response function (HRF) but it is not known how well this fits the actual HRF of epileptic spikes. The objective of this exploratory study was to compare the activated areas and t-statistical scores obtained with a standard HRF to those obtained with a patient-specific HRF. Eight patients with focal epilepsy were studied. We obtained an estimate of the patient-specific HRFs for each patient at the local maximum of activation in the standard HRF analysis. The activated areas obtained with the patient-specific HRFs were larger or similar to the originally activated areas. Additional activated areas were seen in five patients, and most were compatible with the EEG and anatomical MRI localization of epileptogenic and lesional regions. Using patient-specific HRFs brings increased sensitivity to the analysis of epileptic spikes by EEG-fMRI.

Cerebrovascular Circulation↗

Quality of EEG in simultaneous EEG-fMRI for epilepsy.

It is now possible to record the EEG continuously during fMRI studies. This is a very promising methodology that combines knowledge about neuronal activity and its metabolic response. The EEG recorded inside the fMRI scanner is, however,heavily contaminated by artifacts caused by the high intensity magnetic field and rapidly changing field gradients. Methods have been reported in the literature to reduce or eliminate these artifacts, in particular the ballistocardiogram and the artifact caused by currents induced by rapidly changing magnetic gradients. Nevertheless, recording the EEG simultaneously with fMRI remains an extremely delicate operation. In addition the use of artifact removal methods has only been reported by the laboratories in which they were developed. We report here the practical procedures we developed to reduce artifacts in a series of 10 epileptic patients, in the context of the visualization of epileptic spikes. We illustrate the effectiveness of methods designed to remove the scanning artifact and present new methods for removing the ballistocardiographic artifact. We present and evaluate techniques to obtain an EEG of good quality when performing simultaneous EEG and fMRI studies.

Artifacts↗

A simulation study of the error in dipole source localization for EEG spikes with a realistic head model.

OBJECTIVE: We tried to determine the error range of dipole modeling for EEG spikes originating from various clinically important sources by a simulation study employing a realistic head model. The computed error range was also compared with the degree of disturbance of dipole modeling caused by adding background activity to the spike. METHODS: The scalp fields generated by temporal, frontal and rolandic epileptic sources with spatial extent were simulated, and the corresponding 3-dimensional maps of residual variance (RV) were built by computing the RV for a single dipole at each point on a fine imaginary grid in the brain. Single dipole modeling was also performed for the simulated scalp fields after adding real background activity. RESULTS: The brain volume corresponding to a small RV was compact for the frontal sources and the lateral and baso-mesial temporal sources, and large for the anterior and baso-lateral temporal sources. The distribution of dipoles estimated for spikes contaminated with background corresponded to that of the volume of small RV and to spike-amplitude. Estimates were improved by employing inferior temporal electrodes. CONCLUSIONS: When evaluating dipole models of epileptic spikes, error ranges can be estimated and they vary considerably from region to region. SIGNIFICANCE: This study illustrates the variability of the error in dipole modeling of epileptic spikes. This variability is important when considering the clinical interpretation of modeling results.

Brain Mapping↗

fMRI activation in continuous and spike-triggered EEG-fMRI studies of epileptic spikes.

PURPOSE: To evaluate functional magnetic resonance imaging (fMRI) with simultaneous EEG for finding metabolic sources of epileptic spikes. To find the localizing value of activated regions and factors influencing fMRI responses. METHODS: Patients with focal epilepsy and frequent spikes were subjected to spike-triggered or continuous fMRI with simultaneous EEG. Results were analyzed in terms of fMRI activation, concordance with the location of EEG spiking and anatomic MRI abnormalities, and other EEG and clinical variables. In four patients, results also were compared with those of intracerebral EEG. RESULTS: Forty-eight studies were performed on 38 patients. Seventeen studies were not analyzed, primarily because no spikes occurred during scanning. Activation was obtained in 39% of 31 studies, with an activation volume of 2.55 +/- 4.84 cc. Activated regions were concordant with EEG localization in almost all studies and confirmed by intracerebral EEG in four patients. Forty percent of patients without an MRI lesion showed activation; 37.5% of patients with a lesion had an activation; the activation was near or inside the lesion. Bursts of spikes were more likely to generate an fMRI response than were isolated spikes (76 vs. 11%; p < 0.05). CONCLUSIONS: Combining EEG and fMRI in focal epilepsy yields regions of activation that are presumably the source of spiking activity. These regions are highly linked with epileptic foci and epileptogenic lesions in a significant number of patients. Activation also is found in patients with no visible MRI lesion. Intracerebral recordings largely confirm that these activation regions represent epileptogenic areas. It is still unclear why many patients show no activation.

Action Potentials↗

Quantitative interictal subdural EEG analyses in children with neocortical epilepsy.

PURPOSE: We studied the relation between quantitative interictal subdural EEG data and visually defined ictal subdural EEG findings in children with intractable neocortical epilepsy, and determined whether interictal EEG data are predictive of ictal EEG onset zones. METHODS: Thirteen children (aged 1.2-15.4 years) underwent prolonged intracranial EEG recording, using 48- to 120-channel subdural electrodes. Three distinct 10-min segments of the continuous interictal EEG recording were selected for each patient, and the spike frequency for each channel was determined by using an automatic spike-detection program. Subsequently the average spike frequency of each electrode was compared with ictal assessment (onset, spread, and no early ictal involvement). In addition, 50 distinct interictal spikes were averaged for each patient, and the amplitude and latency after the leading spike (averaged spike showing the earliest peak) were measured for each electrode and analyzed with respect to ictal EEG findings. RESULTS: Reproducibility of the spike-frequency pattern derived from three 10-min segments was high (Kendall's W, 0.85 +/- 0.08). Electrodes showing the highest spike frequency, the highest spike amplitude, and the leading spike were found to be a part of the seizure onset in 13 of 13, 12 of 13, and 10 of 13 cases, respectively. There was significant correlation between ictal assessment and spike frequency as well as spike amplitude. A receiver operating characteristics analysis showed that a cutoff threshold at 14% of the maximal spike frequency resulted in a specificity of 0.90 and a sensitivity of 0.77 for the detection of seizure-onset electrodes. CONCLUSIONS: Quantitative interictal subdural EEG may predict ictal-onset zones in children with intractable neocortical epilepsy.

Adolescent↗

Conventional and reciprocal approaches to the inverse dipole localization problem of electroencephalography.

Forward transfer matrices relating dipole source to surface potentials can be determined via conventional or reciprocal approaches. In numerical simulations with a triangulated boundary-element three-concentric-spheres head model, we compare four inverse electroencephalogram (EEG) solutions: those obtained utilizing conventional or reciprocal forward transfer matrices, relating in each case source dipole components to potentials at either triangle centroids or triangle vertices. Single-dipole inverse solutions were obtained using simplex optimization with an additional position constraint limiting solution dipoles to within the brain region. Dipole localization errors are presented in all four cases, for varying dipole eccentricity and two different values of skull conductivity. Both conventional and reciprocal forward transfer matrices yielded inverse dipole solutions of comparable accuracy. Localization errors were low even for highly eccentric source dipoles on account of the nonlinear nature of the single-dipole solution and the position constraint. In the presence of Gaussian noise, both conventional and reciprocal approaches were also found to be equally robust to skull conductivity errors.

Action Potentials↗

Noninvasive methods for evaluating the localization and propagation of epileptic activity.

There are multiple approaches to analyzing the scalp EEG to obtain information on the intracerebral generators of epileptic activity. We review here a few of these methods, as they have been applied in various research projects carried out at the Montreal Neurological Institute. The areas covered include the validation of dipole models of epileptic spikes and of seizure discharges, the EEG microscope of Kobayashi, the analysis of rapid spread of epileptic seizures, and the recently developed method of combining EEG and functional magnetic resonance imaging to obtain activation regions at the time of spikes.

Brain↗

The BOLD response to interictal epileptiform discharges.

We studied single-event and average BOLD responses to EEG interictal epileptic discharges (IEDs) in four patients with focal epilepsy, using continuous EEG-fMRI during 80-min sessions. The detection of activated areas was performed by comparing the BOLD signal at each voxel to a model of the expected signal. Since little is known about the BOLD response to IEDs, we modeled it with the response to brief auditory events (G. H., NeuroImage 9, 416-429). For each activated area, we then obtained the time course of the BOLD signal for the complete session and computed the actual average hemodynamic response function (HRF) to IEDs. In two of four patients, we observed clear BOLD responses to single IEDs. The average response was composed of a positive lobe peaking between 6 and 7 s in all patients and a negative undershoot in three patients. There were important variations in amplitude and shape between average HRFs across patients. The average HRF presented a wider positive lobe than the Glover model in three patients and a longer undershoot in two. There was a remarkable similarity in the shape of the HRF across areas for patients presenting multiple activation sites. There was no clear correlation between the amplitude of individual BOLD responses and the amplitude of the corresponding EEG spike. The possibility of a longer HRF could be used to improve statistical detection of activation in simultaneous EEG-fMRI. The variability in average HRFs across patients could reflect in part different pathophysiological mechanisms.

Adolescent↗

Systematic source estimation of spikes by a combination of independent component analysis and RAP-MUSIC. I: Principles and simulation study.

OBJECTIVES: We propose a combination of independent component analysis (ICA) and recursively applied and projected multiple signal classification (RAP-MUSIC) as a new approach to dipole source estimation of epileptiform discharges. The method is minimally dependent on subjective decisions. METHODS: Ten electroencephalographic (EEG) data matrices were generated by computer, each matrix including real background activity from a normal subject and an array of added simulated spikes. Each spike was a summation of two transients originating from slightly different 'original dipole sources'. The unaveraged EEG matrices were decomposed by ICA, and source estimation was performed by applying RAP-MUSIC to the spatial information defined by the ICA components showing epileptiform activity in their waveform. For comparison, dipoles were also estimated from the same matrices using two existing methods: RAP-MUSIC based on eigen-decomposition of the covariance matrices of averaged spikes and common spatial pattern decomposition. RESULTS: In every simulated EEG data matrix, two dipoles close to the original sources were estimated by the present method. Their unaveraged activities were also similar to those of the original sources. The two existing methods gave less precise results than the proposed method. CONCLUSIONS: RAP-MUSIC based on ICA thus proved promising for source estimation of unaveraged epileptiform discharges.

Brain↗

Systematic source estimation of spikes by a combination of independent component analysis and RAP-MUSIC. II: Preliminary clinical application.

OBJECTIVES: We tried to estimate epileptic sources by a combination of independent component analysis (ICA) and recursively applied and projected multiple signal classification (RAP-MUSIC) in real epileptiform EEG discharges. METHODS: EEG data including an array of spikes from 3 patients were decomposed by ICA, and source estimation was performed by applying RAP-MUSIC to the spatial information defined by the set of ICA components that showed epileptiform activity in their waveform. Sources were also estimated from the same data using RAP-MUSIC based on eigen-decomposition of the covariance matrix of averaged spikes, and common spatial pattern decomposition for comparison. RESULTS: RAP-MUSIC based on ICA could estimate generally correct epileptic sources in the 3 patients, and its results were better than those of the other methods, when compared to intracerebral data. The present analysis proceeded without introduction of subjective decision after data selection. The separation of epileptiform discharges from the background is essential for this analysis, and was successfully performed in the real EEG data. CONCLUSIONS: RAP-MUSIC based on ICA appears promising for estimation of epileptic sources with minimal dependence on subjective decisions in the process of analysis. In particular, it was not necessary to select the number of sources.

Brain↗

Heart rate changes and ECG abnormalities during epileptic seizures: prevalence and definition of an objective clinical sign.

PURPOSE: To determine the prevalence of heart rate changes and ECG abnormalities during epileptic seizures and to determine the timing of heart rate changes compared to the first electrographic and clinical signs. To assess the risk factors for the occurrence of ECG abnormalities. METHODS: We analyzed retrospectively 281 seizures in 81 patients with intractable epilepsy who had prolonged video-EEG and two-channel ECG. The nature and timing of heart rate changes compared to the electrographic and clinical seizure onset was determined. The ictal period (including one minute preictally and three minutes postictally) was analyzed for cardiac arrhythmias, conduction and repolarization abnormalities. Risk factors for cardiac abnormalities were investigated using parametric and non-parametric statistics. RESULTS: There was an increase in heart rate of at least 10 beats/minute in 73% of seizures (93% of patients) and this occurred most often around seizure onset. In 23% of seizures (49% of patients) the rate increase preceded both the electrographic and the clinical onset. ECG abnormalities were found in 26% of seizures (44% of patients). One patient had an asystole for 30 seconds. Long seizure duration increased the occurrence of ECG abnormalities. No other risk factor was found. CONCLUSIONS: Heart rate changes occur frequently and occur around the time or even before the earliest electrographic or clinical change. The change can clarify the timing of seizure onset and the specific rate pattern may be useful for seizure diagnosis and for automatic seizure detection. ECG abnormalities occur often and repeatedly in several seizures of the same patient.

Adult↗

Computer-aided spatial classification of epileptic spikes.

The authors present a method that can be used to identify exemplar spikes from prolonged EEG recordings. To achieve this they have calculated single dipole source models for each automatically detected spike-like waveform. They used a dipole source algorithm that is computationally light and can be run on-line during EEG acquisition. Although a single dipole source model may not provide anatomically accurate information about the location of generators of all epileptiform abnormalities, it does provide a novel spatial parameter that may be useful in its own right. The authors use this spatial parameter and present the relative spatial density of the dipole locations in the form of three planar projections of the spherical model (a view from above, a view from the right, and a view from behind) and allow users to define the x-, y-, and z-coordinates of points of interest within the spherical model. They then present 10 example waveforms of events that have dipole source model locations that occur close to that seed coordinate. Overall, they found that this method performs very well for frequent events, but does not perform well for rare events or for diffuse EEG abnormalities.

Computer-Aided Design↗