Search PubMed⌕ Search

Biomedical subjects

Jean Cumps

Publications and source records attributed to Jean Cumps.

2 recordsLinked to original sources

Improved real-time RT-PCR method for high-throughput measurements using second derivative calculation and double correction.

Quantification of mRNA expression levels using real-time reverse transcription PCR (RT-PCR) is increasingly used to validate results of DNA microarrays or GeneChips. It requires an improved method that is more robust and more suitable for high-throughput measurements. In this report, we compare a user non-influent, second derivative method with that of a user influent, fit point method that is widely used in the literature. We also describe the advantage of using a double correction: one correction using the expression levels of a housekeeping gene of an experiment as an internal standard and a second using reference expression levels of the same housekeeping gene in the tissue or cells. The first correction permits one to decrease errors due to sample preparation and handling, while the second correction permits one to avoid the variation of the results with the variability of housekeeping in each tissue, especially in experiments using various treatments. The data indicate that the real-time PCR method is highly efficient with an efficiency coefficient close to the theoretical value of two. The results also show that the second derivative method is more accurate than the fit point method in quantifying low gene expression levels. Using triplicate experiments, we show that measurement variations using our method are low with a mean of variation coefficients of <1%.

Algorithms↗

Modified method to measure nasal potential difference.

Nasal potential difference (NPD) measurements have been proposed to assess defective ion transport in cystic fibrosis (CF). Implementing it routinely is, however, difficult. Therefore, a modified method based on nasal instillation in supine position at reduced flow rate was tested to evaluate its ability to discriminate CF from non-CF subjects. Classical and modified methods were compared in nine healthy subjects and there were no statistical differences. Following the new method, 97 tests were performed on 74 subjects divided in three cohorts: 21 CF patients and two control groups consisting of 19 patients with other pulmonary diseases and 34 healthy subjects. Twenty five children were enrolled in this study. Maximal NPD in CF patients (-44.9 +/- 2.5 mV) was significantly different from that obtained in control groups (-18.1 +/- 1.6 and -17.2 +/- 1.1 mV). Depolarization after amiloride also discriminated CF patients (25.9 +/- 1.4 mV) from control groups (10.5 +/- 0.9 and 8.1 +/- 0.7 mV). Marked repolarization following isoprenaline plus amiloride in low chloride solution was seen in control groups (-15.7 +/- 1.1 and -15.3 +/- 1.1 mV). We conclude that the modified method represents a simplified and equally effective approach to discriminate CF patients from non-CF subjects. Moreover, this method presents practical advantages for the patients related to hygiene and convenience, favoring its application in small children.

Adolescent↗