Iterative zonal wave-front estimation algorithm for optical testing with general-shaped pupils.

An iterative zonal wave-front estimation algorithm for slope or gradient-type data in optical testing acquired with regular or irregular pupil shapes is presented. In the mathematical model proposed, the optical surface, or wave-front shape estimation, which may have any pupil shape or size, shares a predefined wave-front estimation matrix that we establish. Owing to the finite pupil of the instrument, the challenge of wave front shape estimation in optical testing lies in large part in how to properly handle boundary conditions. The solution we propose is an efficient iterative process based on Gerchberg-type iterations. The proposed method is validated with data collected from a 15 x 15-grid Shack-Hartmann sensor built at the Nanjing Astronomical Instruments Research Center in China. Results show that the rms deviation error of the estimated wave front from the original wave front is less than lambda/130-lambda/150 after approximately 12 iterations and less than lambda/100 (both for lambda = 632.8 nm) after as few as four iterations. Also, a theoretical analysis of algorithm complexity and error propagation is presented.

Journal Article↗

Compact microlenslet-array-based magnifier.

An ultracompact optical imaging system allowing various magnifications or demagnifications and based on microlenslet arrays is presented for the first time to our knowledge. This research generalizes recent findings regarding microlenslet-array-based 1:1 relay systems [Appl. Opt. 42, 6838 (2003)]. Through optical ray tracing, the feasibility of magnifying gray-scale images through a stack of two dissimilar microlenslet arrays is demonstrated for the first time to our knowledge. Results presented specifically demonstrate that a compact imaging system operating at a magnification of 2 is feasible with an overall length of approximately 9 mm. Optical aberrations of the most basic configuration are evaluated, and optimization is discussed.

Journal Article↗

Design and assessment of microlenslet-array relay optics.

Recent progress in micro-optics fabrication and optical modeling software opens the opportunity to investigate how microlenslet-array-based compact relay systems can be designed and assessed. We present various optical configurations that include an appropriate baffle computation to eliminate ghost images, followed by an analysis of image quality. The investigation shows the existing trade-off between compactness of the system and a tiling effect observed in the corresponding image, an effect we refer to as lensletization. To yield meaningful optical modeling results, we provide insight into ray-tracing optimization while ensuring a sufficient signal-to-noise ratio. The results show that, given no discernable lensletization, the most compact configuration to image gray-scale images is the 5f-based system. Finally, simulations of the imaging of gray scale and color bitmaps through microlenslet arrays are demonstrated for the first time to our knowledge.

Journal Article↗

Spectral shaping to improve the point spread function in optical coherence tomography.

We demonstrate inhibition of the sidelobes of the axial point spread function in optical coherence tomography by shaping the power spectrum of the light source with a remaining power of 4.54 mW. A broadband amplified spontaneous emission source radiating at 1565 +/- 40 nm is employed in a free-space optical coherence tomography system. The axial point spread functions before and after optical spectral shaping are presented. Results show that spectral shaping of the source can inhibit sidelobes of the point spread function up to 12.9 dB, with an associated small increase of 2.2 dB in noise floor in the far field. The effect of spectral shaping on axial resolution is demonstrated according to three metrics. Image quality improvement is also illustrated with optical coherence tomography images of an onion before and after spectral shaping.

Equipment Design↗

Design of an ultralight and compact projection lens.

Driven by the need for lightweight head-mounted displays, we present the design of an ultralight and compact projection lens for a head-mounted projective display (HMPD). An HMPD consists of a pair of miniature projection lenses, beam splitters, and miniature displays mounted on the helmet and retroreflective sheeting materials placed strategically in the environment. The HMPD has been proposed recently as an alternative modality for three-dimensional visualization. After demonstrating the concept, building a first-generation custom-designed prototype, and investigating perception issues and application potentials, we designed an ultralight and compact projective lens with a diffractive optical element (DOE), plastic components, and aspheric surfaces for the next-generation prototype. The key contribution here lies in the conception, optimization, and assessment of the projection optics. Thus a brief review of the HMPD technology and related research is followed by a detail discussion of the conception and optimization of the ultralight and high-performance projection optics. The design of the DOE will be particularly described in detail. Finally, the diffraction efficiency of the DOE will be evaluated, and the overall performance of the optics will be assessed in both object space for the optical designer and visual space for possible end-users of the technology.

Equipment Design↗

Estimation of longitudinal resolution in optical coherence imaging.

The spectral shape of a source is of prime importance in optical coherence imaging because it determines several aspects of image quality, especially longitudinal resolution. Wide spectral bandwidth, which provides short coherence length, is sought to obtain high-resolution imaging. To estimate longitudinal resolution, the spectral shape of a source is usually assumed to be Gaussian, although the spectra of real sources are typically non-Gaussian. We discuss the limit of this assumption regarding the estimation of longitudinal resolution. To this end, we also investigate how coherence length is related to longitudinal resolution through the evaluation of different definitions of the coherence length. To demonstrate our purpose, the coherence length for several theoretical and real spectral shapes of sources having the same spectral bandwidth and central wavelength is computed. The reliability of coherence length computations toward the estimation of longitudinal resolution is discussed.

Journal Article↗

Augmented reality and training for airway management procedures.

Augmented reality is often used for interactive, three-dimensional visualization within the medical community. To this end, we present the integration of an augmented reality system that will be used to train military medics in airway management. The system demonstrates how a head-mounted projective display can be integrated with a desktop PC to create an augmented reality visualization. Furthermore, the system, which uses a lightweight optical tracker, demonstrates the low cost and the portability of the application.

Allied Health Personnel↗