Search PubMed⌕ Search

Biomedical subjects

Jan Lovie-Kitchin

Publications and source records attributed to Jan Lovie-Kitchin.

9 recordsLinked to original sources

Dynamics of retinal function after multiple photodynamic therapies in age-related macular degeneration: a report of cases.

PURPOSE: To monitor retinal function after multiple laser treatments by photodynamic therapy (PDT) with the multifocal electroretinogram (mfERG) in age-related macular degeneration (AMD). METHODS: Five eyes of five subjects with AMD were investigated before the first and 1 month after each of three PDT treatments. Function was assessed using the cone- and rod-mediated mfERG, high-contrast distance visual acuity, central visual fields and contrast sensitivity. For each subject the local first-order mfERG results before treatment were used as a template and fitted against the local post-treatment results (Matlab, Mathworks). RESULTS: We found transient reduction of the cone- and rod-mediated amplitudes between the first and second treatments but stable or improved mfERG function in four of five eyes for the cone-mediated mfERG and in all eyes for the rod-mediated mfERG after three treatments. Visual acuities and contrast sensitivities remained stable between treatments in four and two eyes respectively, whereas visual fields showed substantially higher mean defects in two subjects after all treatments. CONCLUSION: As found in previous studies of the cone-mediated mfERG after one PDT treatment, objective function was stabilized after multiple treatments in this case report. Similarly, although poor at baseline, rod-mediated function was not further compromised. Transiently reduced amplitudes after 1 month possibly reflected choroidal hypoperfusion. A larger sample size is needed to confirm if additional evaluation using electrophysiological criteria might be helpful in re-treatment decisions during PDT.

Aged↗

Visual impairment and the useful field of vision.

The aim of this study was to measure the useful field of vision (UFoV) in people with visual impairment and to compare results with clinical measures of vision. UFoV, visual acuity, contrast sensitivity and visual fields were measured in 36 participants with low vision and 22 age-matched controls in two age groups. For both the low vision and control groups the presence of distractors (cluttered field) increased the error rates on our UFoV measure but there was no significant effect of the presence of a central task (divided attention). Participants with low vision made more errors on UFoV than did controls, but this difference disappeared once their visual field defects were accounted for. By multiple regression analysis, age, visual fields and contrast sensitivity were shown to predict the different UFoV scores. As for observers with normal vision, standard clinical visual field tests may not fully describe the difficulties that may be encountered by people with visual impairment undertaking tasks in the cluttered environments and multiple demands of everyday life.

Adult↗

Assessment of age-related maculopathy using subjective vision tests.

This paper reviews non-standard, clinical vision tests that may be used to detect the earliest visual loss in age-related maculopathy (ARM), before fundus changes are detected. We recommend a clinical test battery for all patients aged 60 years and older, comprising low luminance/low contrast (SKILL) VA or low contrast VA, desaturated D-15 colour vision assessment, flicker perimetry, glare recovery and dark adaptation if possible, together with conventional assessments of case history, ophthalmoscopy and high contrast visual acuity (VA) for the detection and diagnosis of ARM. Reading rate is also discussed as a potential indicator of early visual loss. For monitoring the progressive visual loss in age-related macular degeneration (AMD) and determining the requirements for optometric vision rehabilitation, we recommend more conventional clinical vision tests of distance and near visual acuity, reading rate, the effects of varying illumination and a functional central visual field assessment.

Color Perception↗

Objective functional assessment of age-related maculopathy: a special application for the multifocal electroretinogram.

This paper gives a brief review of methods that assess objectively function in age-related maculopathy (ARM) with emphasis on a newer method, the multifocal electroretinogram (mfERG). In contrast to other electrophysiological tests, such as the full-field and focal electroretinogram (ERG) or the electro-oculogram (EOG), which measure summed responses from various cells from larger areas of the retina, the multifocal electroretinogram maps function locally with a resolution as small as four degrees within the central 30 degrees. By using different paradigms it can measure local cone- and rod-mediated functional impairment at early and late stages of ARM. This improved mapping and higher resolution of the posterior pole compared to other objective methods might lead to earlier detection of ARM. Its usefulness has been demonstrated in documenting the effects of treatment after established laser treatments, such as photodynamic therapy (PDT) and in documenting function after retinal pigment epithelial transplantation, a possible future treatment in late neovascular ARM.

Disease Progression↗

Adaptation responses in early age-related maculopathy.

PURPOSE: To investigate the global-flash multifocal electroretinogram (mfERG) in early age-related maculopathy (ARM). METHODS: Thirty-two eyes from 20 healthy control subjects and 12 age-matched subjects with early ARM were investigated with the conventional and the global-flash mfERG. Early ARM subjects were graded according to an international grading system. The conventional mfERG consisted of 103 hexagons flickering according to a pseudorandom m-sequence. The global-flash mfERG paradigm used four frames starting with the conventional m-sequence stimulation, followed by a dark frame, a global flash, and another dark frame. The responses include a direct response (DR) and a later induced component (IC). The first-order kernel peak-to-trough response densities of the conventional mfERG (N1P1), the global-flash DR and IC, and the implicit times of the conventional P1, global-flash DR, and IC peak were analyzed after averaging the results into five groups according to five field locations: a central area and four quadrants. RESULTS: There was a significant reduction of the global-flash mfERG DR response density (P < or = 0.05) in the early ARM group compared with the control group. Neither the IC response density nor DR and IC implicit times were significantly impaired. However, the superior retina showed longer implicit times than did the inferior retina for the DR in the early ARM group. There was no significant correlation between funduscopic features and the central averaged responses of the global-flash mfERG (for the DR response density: r = -0.19, P = 0.3, or for the DR implicit time: r = -0.18, P = 0.3). None of the conventional mfERG parameters was significantly different between the two groups. CONCLUSIONS: The global-flash mfERG detects deficits in early ARM before the conventional mfERG. Retinal ischemia may play a role in producing function impairment in ARM.

Adaptation, Ocular↗

Ian L Bailey.

Explore the source record for details and available documents.

Australia↗

Cone-mediated multifocal electroretinogram in early age-related maculopathy and its relationships with subjective macular function tests.

PURPOSE: To investigate the multifocal electroretinogram (mfERG) and subjective function in early age-related maculopathy (ARM). METHODS: Seventeen subjects with early ARM with visual acuity (VA) of 6/12 or better and 20 age-matched control subjects were examined. We assessed mfERGs, high and low contrast distance VA, near VA, low luminance VA, contrast sensitivity, saturated and desaturated Panel D-15 and visual fields (mean sensitivity). The mfERG responses were analysed by comparing central-overall (method 1) and superior-inferior (method 2) ratios. RESULTS: The mfERG did not discriminate between the groups whereas colour vision (tritan deficiency), contrast sensitivity, and high contrast and low contrast VA showed significantly reduced responses for the early ARM group compared with the control group (p < or = 0.01). The mfERG first-order kernel responses correlated significantly with the desaturated D-15 in both methods (r = -0.5, p < or = 0.05). Fundus grading was not correlated with the mfERG measures. CONCLUSIONS: Although the mfERG correlated significantly with the desaturated D-15 in early ARM, suggesting it operates at a sensitive level, it failed to discriminate between the control and ARM groups. In our sample, the subjective function measures were more sensitive than the mfERG measures.

Aged↗

The rod-mediated multifocal electroretinogram in aging and in early age-related maculopathy.

PURPOSE: To measure function with the rod-mediated multifocal electroretinogram (mfERG) in younger and older subjects with normal vision and with early age-related maculopathy (ARM). METHODS: Thirty subjects were studied: 10 healthy subjects with a mean age of 31 years (young group), 10 healthy subjects with a mean age of 71 years (old group), and 10 early ARM subjects with a mean age of 71 years (early ARM group). The influence of cataract was approximated by retesting five subjects of the young group through an 0.3 neutral density filter (ND filter group). We analyzed first-order N1P1-amplitude and P1-implicit time (P1-IT) mfERG responses and correlated them with funduscopic changes as defined by the Age-Related Eye Disease Study (AREDS) group. RESULTS: Averaged concentric ring P1-ITs were significantly delayed in the old (p = 0.02) and early ARM (p < 0.001) compared with the young group and in the early ARM group compared with the old and ND group (p < or = 0.01). There were no significant differences in N1P1-amplitudes between groups, but there was a significant location effect for all groups with highest mean amplitudes for the most peripheral ring of hexagons (p < 0.01). Significantly delayed overall P1-ITs (p < 0.05) were correlated with progressive funduscopic changes. CONCLUSIONS: Aging and early ARM affects the rod-mediated mfERG, and there is good correlation with funduscopic changes. Although a lens effect cannot be excluded, a neuronal transmission alteration at the postreceptoral level is suggested.

Adult↗