Search PubMed⌕ Search

Biomedical subjects

Jamil Rehman

Publications and source records attributed to Jamil Rehman.

At least 19 recordsLinked to original sources

Needle-based ablation of renal parenchyma using microwave, cryoablation, impedance- and temperature-based monopolar and bipolar radiofrequency, and liquid and gel chemoablation: laboratory studies and review of the literature.

BACKGROUND AND PURPOSE: Small renal tumors are often serendipitously detected during the screening of patients for renal or other disease entities. Rather than perform a radical or partial nephrectomy for these diminutive lesions, several centers have begun to explore a variety of ablative energy sources that could be applied directly via a percutaneously placed needle-like probe. To evaluate the utility of such treatment for small renal tumors/masses, we compared the feasibility, regularity (consistency in size and shape), and reproducibility of necrosis produced in normal porcine kidneys by different modes of tissue ablation: microwaves, cold impedance-based and temperature-based radiofrequency (RF) energy (monopolar and bipolar), and chemical. Chemoablation was accomplished using ethanol gel, hypertonic saline gel, and acetic acid gel either alone or with simultaneous application of monopolar or bipolar RF energy. MATERIALS AND METHODS: A total of 107 renal lesions were created laparoscopically in 33 domestic pigs. Microwave thermoablation (N=12) was done using a Targis T3 (Urologix) 10F antenna. Cryoablation (N=16) was done using a single 1.5-mm probe or three 17F microprobes (17F SeedNet system; Galil Medical) (N=10 single probe and N=6 three probes); a double freeze cycle with a passive thaw was employed under ultrasound guidance. Dry RF lesions were created using custom-made 18-gauge single-needle monopolar probe with two or three exposed metal tips (GelTx) (N=12) or a single-needle bipolar probe (N=6) at 50 W of 510 kHz RF energy for 5 minutes. In addition, a multitine RF probe (RITA Medical Systems) was used in one set of studies (N=6). Both impedance- and temperature-based RF were evaluated. Chemoablation was performed with 95% ethanol (4 mL), 24% hypertonic saline (4 mL), and 50% acetic acid (4 mL) as single injections. In addition, chemoablation was tested with monopolar and bipolar RF (wet RF). Tissues were harvested 1 week after ablation for light microscopy. RESULTS: In 11 of the 15 ablation techniques, there was complete necrosis in all lesions; however, three ethanol gel lesions had skip areas, three hypertonic saline gel lesions showed no necrosis or injury, and one monopolar RF and one bipolar RF lesion showed skip areas. In contrast to impedance-based RF, heat-based RF (RITA) caused complete necrosis without skip areas. All cryolesions resulted in complete tissue necrosis, and cryotherapy was the only modality for which lesion size could be effectively monitored using ultrasound imaging. CONCLUSIONS: Cryoablation and thermotherapy produce well-delineated, completely necrotic renal lesions. The single-probe monopolar and bipolar RF produce limited areas of tissue necrosis; however, both are enhanced by using hypertonic saline, acetic acid, or ethanol gel. Hypertonic saline gel with RF consistently provided the largest lesions. Ethanol and hypertonic saline gels tested alone failed to produce consistent cellular necrosis at 1 week. In contrast, RITA using the Starburst XL probe produced consistent necrosis, while impedance-based RF left skip areas of viable tissue. Renal cryotherapy under ultrasound surveillance produced hypoechoic lesions, which could be reasonably monitored, while all other modalities yielded hyperechoic lesions the margins of which could not be properly monitored with ultrasound imaging.

Acetic Acid↗

Laparoscopic radical prostatectomy: Washington University initial experience and prospective evaluation of quality of life.

BACKGROUND AND PURPOSE: The laparoscopic approach to radical prostatectomy offers an alternative to the open surgical procedure with less morbidity. We prospectively collected data including a validated quality-of-life questionnaires on our first 38 laparoscopic radical prostatectomies (LRPs). The first 10 patients (group 1), second 10 patients (group II), and the most recent 18 patients (group III) were examined separately to study the learning curve for this procedure. In addition, we determined the pattern of recovery of urinary continence, potency, and quality of life. PATIENTS AND METHODS: Between July 1999 and July 2002, 38 consecutive transperitoneal laparoscopic radical prostatectomies were performed for clinically localized prostate carcinoma. Patients completed quality-of-life questionnaires (Rand 36 Health Survey) before surgery as well as at 1, 3, 6, and 12 months and every 6 months thereafter. The patients were also interviewed by an individual not directly involved in patient care. RESULTS: One patient (the second in our experience) was converted to the open approach because of failure to progress. The average operating time for the whole series was 423 +/- 137.6 minutes (range 215-825 minutes), the last 10 procedures taking 305 +/- 63 minutes (range 215-420 minutes). Complications consisted of one case each of intraoperative bladder injury, transient superficial peroneal nerve palsy, pulmonary embolism, and bladder neck obstruction. The bladder injury was closed laparoscopically without further complication. Bladder neck obstruction was secondary to a bladder wall fold that was treated with transurethral resection 14 months after surgery with good results. Four patients in group 1 had minor anastomotic leaks, while only one patient after that had a leak (group III). Four patients required transfusion, two intraoperatively and two postoperatively. In group III, the urethral catheter remained in place for an average of 8 days (range 6-10 days). With a mean follow-up of 22.8 months (range 9-43 months), 84.8% of the patients had perfect urinary control. Postoperatively, 9 patients (27%) were fully continent on removal of the Foley catheter. At 1, 3, 6, and 9 months postoperatively, diurnal urinary control was reported by 30.3%, 48%, 72.7%, and 84.8% of the patients, respectively. One patient needed an artificial urinary sphincter. Among the incontinent patients, 24.2% had urinary urgency, and one third of these patients reported urge incontinence. CONCLUSIONS: Laparoscopic prostatectomy is a reproducible technique with a steep learning curve. Operating times and the incidence of anastomotic leaks and urinary incontinence decrease significantly after the initial 10 patients.

Erectile Dysfunction↗

Prospective comparison of the immunological and stress response following laparoscopic and open surgery for localized renal cell carcinoma.

PURPOSE: We prospectively compared the systemic immune and stress response of patients who underwent laparoscopic total nephrectomy (LRN) (14) and open nephrectomy (ON) (10) for renal cell carcinoma. The ON group comprised open radical (4), open total (2) and open partial (4) nephrectomy cases. MATERIALS AND METHODS: Only patients with no history of cancer or autoimmune disease and American Society of Anesthesiologists score 2 or less who were not using immunosuppressive drugs were selected. Peripheral venous blood was collected preoperatively and intraoperatively, and 24 hours, 2 weeks, 4 weeks and 3 months postoperatively. Blood was analyzed for stress markers (adrenalin, noradrenalin and cortisol), inflammatory response markers (C-reactive protein, white blood count and leukocyte count), lymphocytic response markers (CD3, CD4 and CD8), cytokines interleukin-2 and 4, interferon-alpha and tumor necrosis factor-alpha), HLA-DR expression and the proliferative response to mitogen stimulation using concanavalin A, phytohemagglutinin 10, and pokeweed mitogen. RESULTS: Mean tumor size +/- SD for ON and LRN was 5.6 +/- 2.4 and 4.5 +/- 1.6 cm, respectively (p = 0.21). The trends with time for all measured postoperative parameters were similar in the 2 groups. Inflammatory and stress response markers were statistically similar for in the groups at all time points. A significant difference between the groups was noted for the percentage of CD4+ and CD8+ lymphocytes. However, this difference was present preoperatively and there was no significant absolute change in these 2 parameters. The cytokine response and HLA-DR expression were similar in the 2 groups at all time points. Likewise, the lymphocytic stimulation index for concanavalin A, phytohemagglutinin and pokeweed mitogen were statistically similar for LRN and ON at all time points. CONCLUSIONS: The immunological and stress response after LRN and ON for renal cell carcinoma is similar. The few differences observed in measured parameters likely reflect preoperative differences in baseline and/or the contributory effect of anesthesia.

Carcinoma, Renal Cell↗

Laparoscopic mid sagittal hemicystectomy and bladder reconstruction with small intestinal submucosa and reimplantation of ureter into small intestinal submucosa: 1-year followup.

PURPOSE: We evaluated the long-term results of laparoscopic hemicystectomy and bladder replacement with small intestinal submucosa (SIS) with ureteral reimplantation into the SIS material. MATERIALS AND METHODS: A total of 12 minipigs underwent laparoscopic hemicystectomy. Six pigs underwent bladder reconstruction with SIS and ipsilateral ureteral reimplantation. The remaining 6 control pigs underwent hemicystectomy and primary bladder closure with ipsilateral nephroureterectomy. Preoperative and followup evaluations included blood chemistry, radiography and urodynamic evaluations. The 6, 3, 6 and 9-week, and 12-month followup evaluations included biopsies. At 1 year the animals were sacrificed. Histopathological and contractility studies, and reverse transcriptase-polymerase chain reaction for growth factors and basement membrane components were performed. RESULTS: Bladder capacity and bladder compliance were similar in the 2 groups at all time points. One pig per group died, that is a control at the 9-month evaluation due to an anesthetic complication and an SIS pig 7 months after bladder reconstruction due to spontaneous bladder rupture at the anastomotic site. In the SIS group 4 of 5 surviving pigs had unobstructed reimplanted ureters without evidence of hydroureteronephrosis, while 1 had high grade obstruction at the reimplantation site. Histopathology study after 1 year revealed muscle at the graft periphery and center but it consisted of small fused bundles with significant fibrosis. Nerves were present at the graft periphery and center but they were decreased in number. CONCLUSIONS: Laparoscopic SIS bladder reconstruction and ureteral reimplantation into the SIS after hemicystectomy are technically feasible. However, compared to primary bladder closure no advantage in bladder capacity or compliance was documented.

Animals↗

Combined percutaneous and retrograde approach to staghorn calculi with application of the ureteral access sheath to facilitate percutaneous nephrolithotomy.

PURPOSE: We describe our technique and clinical experience with application of the ureteral access sheath for single access ablation of staghorn and partial staghorn calculi. MATERIALS AND METHODS: We retrospectively reviewed our experience with 9 patients who underwent percutaneous nephrolithotomy for staghorn (6) or partial staghorn (3) renal calculi using a combined antegrade and retrograde approach. Patient data, operative parameters, efficacy of stone ablation and convalescence parameters were reviewed. RESULTS: Mean operative time for the primary procedure was 3.1 hours with a mean estimated blood loss of 290 ml. Postoperatively, the mean analgesic requirement was 33.2 mg. MSO(4) equivalents. Hospital stay was 3.2 days. There were no major and 4 minor (44%) complications. No patient required transfusion. Complete stone clearance was achieved in 7 of the 9 cases (78%) using a single percutaneous nephrostomy tract. CONCLUSIONS: Our preliminary clinical experience using the ureteral access sheath during percutaneous nephrolithotomy for simultaneous antegrade and retrograde stone treatment has been favorable. A large renal stone burden can be successfully managed with a single percutaneous access and limited blood loss.

Humans↗

Characterization of intrapelvic pressure during ureteropyeloscopy with ureteral access sheaths.

OBJECTIVES: To evaluate the impact of the ureteral access sheath on intrarenal pressures during flexible ureteroscopy in light of the recent resurgence in their use. As such, using human cadaveric kidneys, we studied changes in intrarenal pressure in response to continuous irrigation at different pressures with and without access sheaths of various sizes and lengths. METHODS: This study was performed using seven cadaveric kidneys. In three kidneys the study was done in situ with a 7.5F flexible ureteroscope (URS) passed by itself and then passed through a 10/12F sheath (35 and 55 cm in length), whereas, in four kidneys, due to narrowing of the intramural ureter, the study was done ex vivo using the unsheathed URS and then passing the 7.5F flexible URS via the 10/12F, 12/14F, and 14/16F sheaths (all 35 cm in length). A 10F Cope loop pyelostomy was placed to measure intrapelvic renal pressure. Three sets of 3-minute readings (ie, flow and intrarenal pressure) were taken with the tip of the URS at the distal ureter, middle ureter, and renal pelvis (just above the ureteropelvic junction); the entire process was done at three different irrigant pressure settings: 50, 100, and 200 cm H(2)O. Irrigant flow and intrarenal pressures were measured at all three settings using the URS passed without a sheath and then with the URS passed through the various sheaths positioned at the distal ureter, middle ureter, and renal pelvis. RESULTS: With all of the sheaths, intrapelvic pressure remained low (less than 30 cm H(2)O), and there was a 35% to 80% increase in irrigant flow versus the control unsheathed URS. With the sheath in place, the majority of the irrigant drained alongside the URS and out the sheath. Flow and pressure with the 12/14F sheath were equivalent to the 14/16F sheath. CONCLUSIONS: The 12/14F access sheath provides for maximum flow of irrigant while maintaining a low intrarenal pelvic pressure. Even with an irrigation pressure of 200 cm H(2)O, renal pelvic pressure remained below 20 cm H(2)O.

Equipment Design↗

Hemostatic laparoscopic partial nephrectomy assisted by a water-cooled, high-density, monopolar device without renal vascular control.

OBJECTIVES: To evaluate the feasibility of laparoscopic partial nephrectomy assisted by a water-cooled, high-density, monopolar device (TissueLink Floating Ball). METHODS: Transperitoneal laparoscopic partial nephrectomy was performed without vascular control for four renal tumors in 3 patients. A flexible ultrasound probe was used to confirm tumor location and depth. Gerota's fascia was opened distant from the tumor site. Renal fat was dissected from the renal parenchyma except for the fat overlying the tumor. The tumor resection area was marked 1 cm outside the boundaries of the tumor. After application of the TissueLink Floating Ball at the planned surgical margin, the tumor was resected with cold laparoscopic scissors. Bleeding from the vessels of the divided renal parenchyma was controlled with the Floating Ball if necessary. The specimen was sent for frozen section to confirm margin status. RESULTS: Mean estimated blood loss per tumor was 275 mL. The dissection extended to the collecting system in 2 of 4 cases. In 1 patient, a minor postoperative urine leak resolved spontaneously. CONCLUSIONS: Use of the TissueLink Floating Ball facilitated resection of small renal tumors without renal vascular control. Although further study is necessary, water-cooled, high-density monopolar energy may have a role in laparoscopic partial nephrectomy.

Aged↗

Tissue chemoablation.

PURPOSE: To provide an overview of the state of the art of tissue chemoablation in animal and human organs and cancers. We also describe our experience with the feasibility, predictability, and reproducibility of necrosis produced by needle chemoablative therapies including ethanol, hypertonic saline, and acetic acid solutions as well as gels in a porcine renal model. MATERIALS AND METHODS: A MEDLINE search was performed for articles on animal and human tissue chemoablation published since 1965. In addition, at Washington University, experimental chemoablation was performed in pigs with 95% ethanol (4 mL), 24% hypertonic saline (4 mL), or 50% acetic acid (4 mL) solutions as well as in gel form. RESULTS: There is extensive literature on the use of chemoablation for liver metastases; recently, chemoablation of the prostate has become an area of research. Human studies have been limited to patients who are not surgical candidates or to investigational procedures performed prior to definitive prostatic surgery. Animal studies of renal chemoablation as a sole therapy have produced mixed results. In our studies, only acetic acid provided complete necrosis. CONCLUSIONS: To date, ethanol chemoablation has been shown to be feasible and reproducible only for metastatic hepatic carcinoma. In urology, chemoablation is still very much in the investigational stage for both the prostate and the kidney. A significant drawback is that even in the gel form, the spread of the chemoablative substance through the tissue is irregular and unpredictable. In the future, chemoablation may become a more effective modality by combining it with radiofrequency or other energy sources.

Acetic Acid↗

Laparoscopic cyst decortication in autosomal dominant polycystic kidney disease: impact on pain, hypertension, and renal function.

BACKGROUND AND PURPOSE: In patients with autosomal dominant polycystic kidney disease (ADPKD), laparoscopic cyst decortication (LCD) has been proposed as a means to relieve chronic cyst-related pain. We present our 7-year experience with LCD for ADPKD with regard to pain relief, hypertension, and renal function. PATIENTS AND METHODS: Between August 1994 and February 2001, 29 ADPKD patients with chronic pain (N=29), hypertension (N=21), and renal insufficiency (N=10) underwent 35 LCD procedures. Every detectable cyst within 2 mm of the renal surface was treated. Pain relief was assessed using a pain analog scale; relative pain relief (RPR) equaled (preoperative pain score) - (postoperative pain score)/(preoperative pain score). Hypertension was evaluated using the antihypertensive therapeutic index (ATI): [(dose of blood pressure medication 1/max dose 1) + (dose med 2/max dose 2) + etc.] x 10. Renal function was assessed using the Cockcroft and Gault formula for creatinine clearance. RESULTS: The mean operating room time was 4.9 hours (range 2.6-6.6 hours) with no conversions to open surgery. An average of 220 cysts (range 4-692) were treated per patient. The mean follow-up was 32.3 months (range 6-72 months). The RPR was 58%, 47%, and 63% at 12, 24, and 36 months, respectively. At 12, 24, and 36 months, 73%, 52%, and 81% of patients, respectively, noted >50% improvement in their pain compared with the preoperative situation. Five patients became normotensive, and patients improved their ATI by an average of 49% (range 11%-93%). However, six patients had worsening hypertension, with an ATI increase averaging 53% (range 11%-122%), and one patient who was not hypertensive preoperatively has since developed hypertension. The creatinine clearance changed +4%, +7%, and -2% at 12, 24, and 36 months, respectively. Only one patient had a >20% increase in creatinine clearance. The only patients with a >20% decrease in creatinine clearance were those who had a creatinine clearance <30 mg/dL preoperatively (average decrease 34% [range 20%-51%]). CONCLUSIONS: For ADPKD patients with debilitating pain, extensive LCD can provide durable relief. In the majority of patients with pain and hypertension, a marked improvement in blood pressure also occurs. Cyst decortication was not associated with worsening renal function; indeed, renal function remained largely unchanged over the 3-year follow-up period.

Adult↗

Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.

PURPOSE: We assessed the usefulness of the LigaSure (Valleylab, Boulder, Colorado) vessel sealing system for vascular control during laparoscopic surgery and compared it with other available hemostatic modalities. MATERIALS AND METHODS: A total of 31 domestic pigs were divided into 5 groups. In groups 1 and 2 the vessel sealing system was compared with titanium clips and Endo-GIA (United States Surgical, Stamford, Connecticut) staples. In group 3 the vessel sealing system was compared with standard Klepinger (Karl Storz, Culver City, California) bipolar forceps. In group 4 the harmonic scalpel and Trimax (United States Surgical) bipolar forceps were compared. In group 5 in vivo laparoscopic application of the vessel sealing system was evaluated. RESULTS: The 5 mm. laparoscopic vessel sealing system sealed arteries up to 6 mm. and veins up to 12 mm. in diameter at supraphysiological bursting pressure. We evaluated 13 arteries with a diameter of 6 mm. or less at a mean bursting pressure of 662 mm. Hg (range 363 to 1,985) and 11 veins with a diameter of 12 mm. or less with a mean bursting pressure of 233 mm. Hg (range 63 to 440). Collateral tissue damage extended 1 to 3 mm. from the application site. Standard bipolar energy with Klepinger and Trimax forceps was less reliable and in some cases vessel sealing could not be accurately assessed before vessel division. Collateral tissue injury was 1 to 6 mm. The harmonic scalpel did not reliably seal vessels larger than 3 mm. but resulted in the least acute collateral tissue injury of 0 to 1 mm. CONCLUSIONS: In the porcine model the LigaSure system is a viable option for laparoscopic management of arteries up to 6 mm. and veins up to 12 mm. in diameter.

Anastomosis, Surgical↗

Laparoscopic pyeloplasty for secondary ureteropelvic junction obstruction.

PURPOSE: Laparoscopic pyeloplasty has become a viable option for the treatment of select patients with primary ureteropelvic junction obstruction with success rates similar to those of open surgery. However, little has been written on the application of this technique for secondary ureteropelvic junction obstruction. We report the largest series of secondary ureteropelvic junction obstruction managed by laparoscopic pyeloplasty. MATERIALS AND METHODS: Between March 1994 and March 2001, 36 patients underwent laparoscopic transperitoneal pyeloplasty for secondary ureteropelvic junction obstruction. The patients had undergone an average of 1.3 ureteropelvic junction procedures (range 1 to 4) prior to presentation, including cutting balloon retrograde endopyelotomy in 28, antegrade endoscopic endopyelotomy in 7, retrograde endoscopic endopyelotomy in 4, retrograde balloon dilation in 4 and open pyeloplasty in 3. A preoperative diagnosis of recurrent obstruction was confirmed by renal scan in 31 cases, retrograde pyelography in 2 and computerized tomography in 3. Of the 31 patients who underwent spiral computerized tomography angiogram 87% had crossing vessels. Laparoscopic repair comprised dismembered pyeloplasty in 31 cases, Fengerplasty in 3 and flap repair in 2. Postoperative renal scan or excretory urography objective followup was available for all patients at a mean of 10 months (range 3 to 40). Postoperative subjective patient well-being was assessed using an analog pain scale at a mean followup of 21.8 months (range 3 to 85). RESULTS: Average operative time was 6.2 hours (range 2.7 to 10). Average hospital stay was 2.9 days (range 1 to 7). One intraoperative complication occurred, that is bleeding necessitating conversion to an open procedure. Postoperative complications occurred in 8 cases, including anastomotic leakage in 4, and urinary tract infection, pneumonia, atelectasis, fever, bilateral upper extremity weakness and stone formation 2 months postoperatively in 1 each. On excretory urography, furosemide renal scan or the Whitaker test 32 of 36 patients (89%) had a widely patent ureteropelvic junction. Two patients (5.5%) had equivocal radiographic studies but were asymptomatic. In 2 patients the ureteropelvic junction was obstructed by renal scan. One patient had an indwelling stent for renal function deterioration and 1 was asymptomatic. Hence, 34 of the 36 patients (94%) had a reasonable objective response. Overall a 50% or greater decrease in pain was seen in 32 of 36 patients (89%). In the 4 patients with a less than 50% decrease in pain objective renal scans showed an open ureteropelvic junction. As such, the overall success rate of a greater than 50% decrease in pain, a patent ureteropelvic junction and stable or improved function of the affected renal unit was 83% (30 of 36 patients). CONCLUSIONS: For secondary ureteropelvic junction obstruction, laparoscopic pyeloplasty can be performed safely with a success rate comparable to that of standard open pyeloplasty. The patient benefits of laparoscopic ureteropelvic junction repair of secondary ureteropelvic junction obstruction are similar to the benefits of laparoscopic repair of primary ureteropelvic junction obstruction.

Adolescent↗

Evaluation of synchronous twin pulse technique for shock wave lithotripsy: determination of optimal parameters for in vitro stone fragmentation.

PURPOSE: The Twinheads extracorporeal shock wave lithotriptor (THSWL) is composed of 2 identical shock wave generators and reflectors. One reflector is under the table and the other is over the table with a variable angle between the axes of the 2 reflectors. The 2 reflectors share a common second focal point, making it possible to deliver an almost synchronous twin pulse to the targeted stone. We studied the optimal parameters for in vitro stone fragmentation. MATERIALS AND METHODS: Two types of 1 cm artificial stones were used, namely Bon(n)-stones of 3 compositions (75% calcium oxalate monohydrate [COM] plus 25% uric acid, struvite and cystine) and plaster of Paris. The parameters tested were shock wave number (100, 500 and 1,000), shock wave power (8, 11 and 14 kV) and angle between the reflector axes (67, 90 and 105 degrees). After the optimal parameters were determined we studied the disintegrative efficacy of THSWL for 3 types of human urinary calculi, including COM, calcium hydrogen phosphate (brushite) and cystine. Each stone received 1,000 twin shock waves at 14 kV with an angle of 90 degrees between the reflectors. All experiments were done using a rate of 60 twin shock waves per minute. Following lithotripsy stone fragments were processed and sized. The ratio of the weight of fragments greater than 2 mm-to-total weight of all fragments was calculated. RESULTS: Optimal stone fragmentation results for THSWL were obtained with the maximum number of shock waves (1,000) and full power (14 kV). There was no significant statistical difference in fragment size or the ratio of fragments greater than 2 mm with the use of different angles except for cystine and plaster of Paris calculi, for which the right angle was most effective. At application of the optimal parameters to human stones THSWL produced small fragment size for COM and cystine stones, while brushite stones were not fragmented to the same extent. CONCLUSIONS: The efficacy of synchronous twin pulse technology improves as the number of shock waves and power increase. A 90-degree angle between the shock wave reflectors is advantageous for certain stones (that is cystine and plaster of Paris) but it is not a factor for other stone compositions. THSWL has satisfactory disintegrative efficacy for human stones, especially COM and cysteine calculi.

Calcium Oxalate↗

Comparison of intrarenal pressure and irrigant flow during percutaneous nephroscopy with an indwelling ureteral catheter, ureteral occlusion balloon, and ureteral access sheath.

OBJECTIVES: To determine the differential effects on renal pressures and irrigation flow associated with the application of different ureteral catheters during percutaneous nephrolithotomy. METHODS: Using ex vivo fresh cadaveric tissue, we established a percutaneous nephrolithotomy model. After obtaining lower pole percutaneous access, we recorded the pressure and irrigant flow measurements. Measurements were made with an empty ureter, 6F ureteral catheter, occlusion balloon catheter, and ureteral access sheaths (10/12F and 12/14F). Three 1-minute trials for each condition were recorded in each of four kidneys. RESULTS: Ureteral catheterization with both the 10/12F and the 12/14F ureteral access sheaths resulted in significantly decreased intrarenal pressures in the pressure range tested compared with an empty ureter, a ureteral catheter, or an occlusion balloon application. Total irrigant flow for the 12/14F ureteral access sheath was significantly higher than for the empty ureter, ureteral catheter, or occlusion balloon in the entire pressure range evaluated. CONCLUSIONS: In this in vitro cadaveric model, application of the ureteral access sheath during percutaneous nephrolithotomy resulted in decreased intrarenal pressures and increased irrigant flow.

Catheterization↗

Effect of argon-beam coagulation on the integrity of suture material.

PURPOSE: To evaluate the effect of argon-beam coagulator (ABC) energy on suture materials. MATERIALS AND METHODS: Six absorbable and nonabsorbable suture materials (polyglactin, chromic catgut, polydioxanone, silk, poliglecaprone, and Gore-Tex) were placed under tension and exposed to ABC energy to determine breaking times. Subsequently, all suture materials were exposed to limited ABC energy, and tensiometry was used to determine decreases in breaking strengths. RESULTS: Among the suture materials tested, Gore-Tex was the most resistant to ABC energy. Although absorbable suture materials were less resistant than nonabsorbable suture materials, 2-0 polyglactin manifested the greatest resiliance to deterioration with ABC energy exposure. CONCLUSIONS: The ABC has differential effects on suture materials. Larger-gauge suture materials are more resistant to ABC than smaller materials. Similarly, nonabsorbable sutures are generally more resilient to ABC energy than absorbable materials. Among the suture materials evaluated in our in vitro model, 2-0 Gore-Tex was best suited for vascular ligation, and 2-0 polyglactin is optimal for renal collecting system closure if ABC is anticipated as an adjunct for hemostasis.

Absorbable Implants↗

Current management of urolithiasis: progress or regress?

PURPOSE: To assess the impact of the development of less powerful second- and third-generation shockwave lithotripters on surgical stone therapy in light of recent advances in ureteroscopy and laser lithotripsy. As such, we sought to identify current trends in the treatment of stone disease, both at our university medical center and nationally, and to contrast them with the corresponding data from 1990. PATIENTS AND METHODS: All urolithiasis procedures (ureteroscopy, SWL, open surgery, and percutaneous stone removal) performed in 1998 were compared with all urolithiasis procedures performed 8 years earlier (1990) at a single institution (Washington University, St. Louis). In addition, Medicare data for each year from 1988 through 2000 were collected from the Health Care Financing Administration to assess the national trends for open stone surgery, ureteroscopic stone removal, SWL, and percutaneous nephrolithotomy. RESULTS: At Washington University, the number of percutaneous stone removals remained stable; however, the overall number of ureteroscopies increased by 53%, while the number of SWLs, decreased by 15%. The Medicare data likewise reflect a marked decrease in open stone surgery and a marked increase in ureteroscopic stone surgery with a slight increase in SWL. Utilization of percutaneous nephrolithotomy remained unchanged. CONCLUSIONS: We believe this trend toward ureteroscopy is attributable to several factors: improved, smaller rigid and flexible ureteroscopes; the availability of more effective intracorporeal lithotripters (e.g., pneumatic and holmium laser), and the lack of development of lower cost, more effective SWL. This is an unfortunate trend, as we are moving away from the noninvasive treatment that was the hallmark of urolithiasis therapy at the beginning of the last decade toward more invasive endoscopic therapy. Increased research efforts in SWL technology are sorely needed.

Female↗

Renal hypothermia achieved by retrograde intracavitary saline perfusion.

BACKGROUND AND PURPOSE: Hypothermia during vascular clamping protects the kidney from ischemia-induced nephron loss. Traditionally, cooling is achieved by packing the kidney in ice, which lowers the temperature of the rest of the surgical field as well, and the method cannot be used during laparoscopy. We evaluated the utility of a newly developed ureteral access system for circulating ice-cold saline. MATERIALS AND METHODS: Domestic pigs underwent retrograde endoscopic cooling through an access sheath without (N = 2) or with (N = 3) renal artery occlusion, traditional ice-slush cooling with renal artery occlusion (N = 3), or occlusion without hypothermia (N = 3). Five days later, the pigs were sacrificed and the kidneys and ureters examined histologically. RESULTS: Endoscopic cooling with renal artery occlusion and ice-slush cooling both produced renal hypothermia. The former produced medullary and cortical temperatures of 21.3 degrees C and 27.3 degrees C, respectively, and the latter medullary and cortical temperatures of 28.8 degrees C and 23.7 degrees C, respectively. Histologically, there were minimal changes in the first three groups, whereas venous congestion, multifocal chronic inflammation, and periarteriolar hemorrhage were seen after renal artery occlusion without hypothermia. CONCLUSION: Retrograde endoscopic renal hypothermia is effective and requires no novel equipment or special surgical skills. Clinical application has not yet been attempted.

Animals↗

Ferromagnetic self-regulating reheatable thermal rod implants for in situ tissue ablation.

BACKGROUND AND PURPOSE: Ferromagnetic compounds, when placed in a radiofrequency magnetic field, develop an electrical current. When placed in tissue, resistance to the transmission of the electrical current leads to heating of the tissues next to the ferromagnetic compound. The Curie temperature is a transition point at which the development of a particular temperature within the material results in loss of its magnetic properties; as such, when this temperature is reached, there is cessation of current, and thus heat production stops. Our goal was to examine the ablative impact of permanently implanted palladium and cobalt self-regulating temperature rods on solid abdominal and pelvic organs. These rods were designed to develop a maximum temperature of 70 degrees C. MATERIALS AND METHODS: In 16 pigs, renal, hepatic, uterine, and pancreatic ferromagnetic rods were placed using a template. The rods were delivered in 1-cm parallel rows of two rods each in order to ablate 7 g of tissue. The animals were subsequently treated in an extracorporeal magnetic field of 50 gauss rms at a frequency of 50 kHz. The position of the rods was confirmed by fluoroscopy before the animal was put in the magnetic field. The animals received one or two treatment sessions. Intralesional and extralesional temperatures were measured continuously. Serum chemistry was analyzed before surgery, after each treatment, and at the time of harvest. Two weeks following therapy, the treated tissues were harvested and examined histopathologically. RESULTS: In all tissues with properly aligned rods, the temperature of the tissue surrounding the rods exceeded 50 degrees C. Histologic review showed confluent tissue necrosis in 7 of 9 kidneys (78%), 6 of 9 livers (67%), 1 of 3 pancreases (33%), and 1 of 3 uterine specimens (33%). Necrosis extended for 2 mm beyond the periphery of the rods. All failures were secondary to technical misalignment of the rods, which occurred because of our attempt to treat more than one organ in each animal. CONCLUSIONS: Ferromagnetic rods, when properly aligned in a magnetic field, create well-defined areas of necrosis. There are no skip areas of viable tissue within the treated area, and there is a precipitous fall-off of injury just outside the area of treatment. Also, because the rods can be reactivated at any time, recurrent lesions within the same site can be treated. This form of minimally invasive in situ ablative therapy appears promising. Clinical trials in the kidney and in other abdominal and pelvic organs are pending.

Animals↗