Search PubMed⌕ Search

Biomedical subjects

James S Welsh

Publications and source records attributed to James S Welsh.

At least 19 recordsLinked to original sources

Selective Internal Radiation Therapy (SIRT) for liver metastases secondary to colorectal adenocarcinoma.

INTRODUCTION: Selective internal radiation therapy (SIRT) is a relatively new commercially available microbrachytherapy technique for treatment of malignant hepatic lesions using (90)Y embedded in resin microspheres, which are infused directly into the hepatic arterial circulation. It is FDA approved for liver metastases secondary to colorectal carcinoma and is under investigation for treatment of other liver malignancies, such as hepatocellular carcinoma and neuroendocrine malignancies. MATERIALS/METHODS: A modest number of clinical trials, preclinical animal studies, and dosimetric studies have been reported. Here we review several of the more important results. RESULTS: High doses of beta radiation can be selectively delivered to tumors, resulting in impressive local control and survival rates. Ex vivo analyses have shown that microspheres preferentially cluster around the periphery of tumor nodules with a high tumor:normal tissue ratio of up to 200:1. Toxicity is usually mild, featuring fatigue, anorexia, nausea, abdominal discomfort, and slight elevations of liver function tests. CONCLUSIONS: Selective internal radiation therapy represents an effective means of controlling liver metastases from colorectal adenocarcinoma. Clinical trials have demonstrated improved local control of disease and survival with relatively low toxicity. Investigations of SIRT for other hepatic malignancies and in combination with newer chemotherapy agents and targeted biologic therapies are under way or in planning. A well-integrated team involving interventional radiology, nuclear medicine, medical oncology, surgical oncology, medical physics, and radiation oncology is essential for a successful program. Careful selection of patients through the combined expertise of the team can maximize therapeutic efficacy and reduce the potential for adverse effects.

Adenocarcinoma↗

Electron capture.

Explore the source record for details and available documents.

Electrons↗

Clinical implementation of adaptive helical tomotherapy: a unique approach to image-guided intensity modulated radiotherapy.

Image-guided IMRT is a revolutionary concept whose clinical implementation is rapidly evolving. Methods of executing beam intensity modulation have included individually designed compensators, static multi-leaf collimators (MLC), dynamic MLC, and sequential (serial) tomotherapy. We have developed helical tomotherapy as an innovative solution to overcome some of the limitations of other IMRT systems. The unique physical design of helical tomotherapy allows the realization of the concepts of adaptive radiotherapy and conformal avoidance. In principle, these advances should improve normal tissue sparing and permit dose reconstruction and verification, thereby allowing significant biologically effective dose escalation. Recent radiobiological findings can be translated into altered fractionation schemes that aim to improve the local control and long-term survival. This strategy is being tested at the University of Wisconsin using helical tomotherapy with its highly precise delivery and verification system along with meticulous and practical forms of immobilization. Innovative techniques such optical guidance, respiratory gating, and ultrasound assessments are being designed and tailored for helical tomotherapy use. The intrinsic capability of helical tomotherapy for megavoltage CT (MVCT) imaging for IMRT image-guidance is being optimized. The unique features of helical tomotherapy might allow implementation of image-guided IMRT that was previously impossible or impractical. Here we review the technological, physical, and radiobiological rationale for the ongoing and upcoming clinical trials that will use image-guided IMRT in the form of helical tomotherapy; and we describe our plans for testing our hypotheses in a rigorous prospective fashion.

Humans↗

Beta radiation.

Explore the source record for details and available documents.

Beta Particles↗

Feasibility study of helical tomotherapy for total body or total marrow irradiation.

Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy, (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (+/-10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (+/-7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In addition, conformal radiation to the bone marrow appears feasible in an external radiation treatment using image-guided helical tomotherapy.

Bone Marrow↗

Precautions in the use of intensity-modulated radiation therapy.

Intensity-modulated radiation therapy (IMRT) represents a significant technological advancement in the ability to deliver highly conformal radiation therapy. Thanks to increased availability, general clinical implementation has become progressively more common. However, there are several precautions worthy of comment regarding the clinical applications of IMRT. In theory, the increased irradiated volume and leakage radiation that occasionally accompanies IMRT could contribute to unanticipated complications and safety concerns. The protracted delivery time of IMRT with the associated increased linac monitor units can result in photoactivation of elements within the linac collimator, thereby inadvertently increasing radiation exposure to patients and staff when high-energy photons are used. The increased volumes of normal tissue exposed to lower doses of radiation through IMRT theoretically could promote carcinogenesis and complications due to the bystander effect, low-dose hyper-radiosensitivity, and diminished repair of double strand DNA breaks at very low doses. Tumor control may be adversely affected by the lower radiation dose-rates of delivery sometimes associated with IMRT as well the occasionally seen low dose "cold shoulder" on the dose-volume histograms. Unusual clinical reactions can appear as a result of the complex, unfamiliar dose-distributions occasionally generated by IMRT treatment planning. Here we discuss some of the precautions worthy of consideration when using IMRT and how these might be addressed in routine practice.

Animals↗

A case of Gorham's disease with chylothorax treated curatively with radiation therapy.

Gorham's disease, also known as vanishing bone disease or massive osteolysis, is a rare disorder of uncertain etiology. It is characterized by uncontrolled proliferation of vascular or lymphatic capillaries within bone, leading to resorption and replacement with angiomatous tissue. It can be complicated by chylous pericardial and pleural effusions, which can be life threatening. Patients are also at risk of mortality or serious morbidity due to bone destruction, especially when the disease involves the spine. We report the case of a 31-year-old female with Gorham's disease involving several bones along with chylous pericardial and pleural effusions. She was effectively treated with definitive radiation therapy.

Adult↗

Loss of biological effect in prolonged fraction delivery.

PURPOSE: The decrease of biologic effect if delivery of dose fractions takes more than a few minutes has been occasionally recognized in the literature but has been insufficiently studied. It has been recognized as a problem in the long exposures necessary for stereotactic radiotherapy and is also a potential problem in some applications of IMRT. Modeling repair rates is a complex function of dose per fraction, dose rate, half-times of repair, and nature of the tissue of interest (the alpha/beta ratio of intrinsic radiosensitivity to repair capacity). In this article, we model repair rates for a range of doses per fraction and draw conclusions. METHODS AND MATERIALS: We review the data on half-times of repair in tissues in situ in animals and human patients and conclude that a single first-order (exponential) repair rate is no longer an appropriate assumption for most tissues. At least 2 half-times of repair, and perhaps a distribution of half-times, are required. The faster components have a median half-time of 0.3 h (range, 0.08-1.2 h), and the longer components have a median of 4 h (range, 2.4->6 h). Modeling repair rates by a two-component model is the simplest approach. We have used two models of repair to represent these ranges, one with equal proportions of 0.2 h + 4.0 h half-times, the other with 0.4 h + 4.0 h half-times of repair. Data are also reviewed on the few experiments that have been reported with cell culture that investigate this problem. RESULTS: Computations indicate that any fraction delivery that lasts more than half an hour might experience a clinically significant loss of cell-sterilizing effect. We suggest that a loss of more than 10% in biologically effective dose should be compensated for and show modeled doses and fraction durations for which this situation seems to be likely. It will be dose, tissue, and system dependent and will require more investigation at the clinical level. CONCLUSION: It is suggested that any radiotherapy schedule that requires more than half an hour for the delivery of 1 fraction should have careful records made and reported, to look for a possible decrease of biologic effect with fraction duration.

Animals↗

Fiducial markers implanted during prostate brachytherapy for guiding conformal external beam radiation therapy.

Prostate movement imposes limits on safe dose-escalation with external beam radiation therapy. If the precise daily location of the prostate is known, dose escalation becomes more feasible. We have developed an approach to dose escalation using a combination of prostate brachytherapy followed by external beam radiation therapy in which fiducial markers are placed along with (125)I seeds during transperineal interstitial permanent prostate brachytherapy. These markers serve to verify daily prostate location during the subsequent external beam radiotherapy. Prior to implementing this approach, preliminary studies were performed to test visibility of the markers. Three different (125)I seed models, as well as gold and silver marker seeds were placed within tissue-equivalent phantoms. Images were obtained with conventional x-rays (75-85 kV) and 6 MV photons from a linear accelerator. All (125)I seed models were clearly visible on conventional x-rays but none were seen with 6 MV photons. The gold markers were visible with both energies. The silver markers were visible with conventional x-rays and 6 MV x-rays, but not as clearly as the gold seeds at 6 MV. Subsequently, conventional x-rays, CT scans, and 6 MV port films were obtained in 29 patients in whom fiducial gold marker seeds were implanted into the prostate during (125)I prostate brachytherapy. To address the possibility of "seed migration" within the prostate, CT scans were repeated 5 weeks apart in 14 patients and relative positions of the gold seeds were evaluated. The repeated CT scans showed no change in intraprostatic gold marker location, suggesting minimal migration. The gold seeds were visible with conventional x-rays, CT, and 6 MV port films in all patients. During the course of external beam radiation therapy, the gold markers were visible on routine 6 MV port films and were seen in different locations from film to film suggesting prostate motion. Mean daily displacement was 4-5 mm in the anterior-posterior, and 4-5 mm in superior-inferior dimensions. Left-right displacement appeared less, averaging 2-3 mm. We conclude that implantation of gold marker seeds during prostate brachytherapy represents an easily implemented and practical means of prostate localization during subsequent image-guided external beam radiotherapy. With such markers, conformality of the external beam component can be confidently improved without expensive new equipment.

Brachytherapy↗

Helical tomotherapy as a means of delivering accelerated partial breast irradiation.

A novel treatment approach utilizing helical tomotherapy for partial breast irradiation for patients with early-stage breast cancer is described. This technique may serve as an alternative to high dose-rate (HDR) interstitial brachytherapy and standard linac-based approaches. Through helical tomotherapy, highly conformal irradiation of target volumes and avoidance of normal sensitive structures can be achieved. Unlike HDR brachytherapy, it is noninvasive. Unlike other linac-based techniques, it provides image-guided adaptive radiotherapy along with intensity modulation. A treatment planning CT scan was obtained as usual on a post-lumpectomy patient undergoing HDR interstitial breast brachytherapy. The patient underwent catheter placement for HDR treatment and was positioned prone on a specially designed position-supporting mattress during CT. The planning target volume (PTV) was defined as the lumpectomy bed plus a 20 mm margin. The prescription dose was 34 Gy (10 fx of 3.4 Gy) in both the CT based HDR and on the tomotherapy plan. Cumulative dose-volume histograms (DVHs) were generated and analyzed for the target, lung, heart, skin, pectoralis muscle, and chest wall for both HDR brachytherapy and helical tomotherapy. Dosimetric coverage of the target with helical tomotherapy was conformal and homogeneous. "Hot spots" (> or =150% isodose line) were present around implanted dwell positions in brachytherapy plan whereas no isodose lines higher than 109% were present in the helical tomotherapy plan. Similar dose coverage was achieved for lung, pectoralis muscle, heart, chest wall and breast skin with the two methods. We also compared our results to that obtained using conventional linac-based three dimensional (3D) conformal accelerated partial breast irradiation. Dose homogeneity is excellent with 3D conformal irradiation, and lung, heart and chest wall dose is less than for either HDR brachytherapy or helical tomotherapy but skin and pectoral muscle doses were higher than with the other techniques. Our results suggest that helical tomotherapy can serve as an effective means of delivering accelerated partial breast irradiation and may offer superior dose homogeneity compared to HDR brachytherapy.

Brachytherapy↗