Search PubMed⌕ Search

Biomedical subjects

James G Fujimoto

Publications and source records attributed to James G Fujimoto.

At least 37 records · Page 2Linked to original sources

Ultrahigh resolution optical coherence tomography in macular dystrophy.

PURPOSE: To visualize and investigate intraretinal changes in macular dystrophies with ultrahigh resolution optical coherence tomography (UHR OCT). DESIGN: Prospective observational case series. METHODS: setting: Department of Ophthalmology and Center for Biomedical Engineering and Physics, Christian Doppler Laboratory, Medical University of Vienna, Vienna, Austria. patients: Thirteen patients (23 eyes) with adult-onset foveomacular vitelliform dystrophy (AOFVD) and 14 patients (27 eyes) with Stargardt's disease (SD) or fundus flavimaculatus (FF). OBSERVATIONS: Imaging using a compact, new generation UHR OCT system, achieving considerably improved visualization of intraretinal layers, especially the photoreceptor layer. main outcome measures: UHR OCT tomograms visualizing intraretinal differences in morphology of AOFVD and SD/FF as location and extension of deposits and loss of photoreceptors. Central foveal thickness defined as distance between internal limiting membrane and photoreceptors/retinal pigment epithelium interface. RESULTS: Patients with AOFVD had a mostly intact photoreceptor layer, a central foveal thickness of 142 +/- 23 microm as well as subretinal deposits. Patients with SD generally had a diffuse degenerative change with a visible reduction in thickness of all intraretinal layers, resulting in a corresponding reduction of central foveal thickness (94 +/- 38 microm) and central loss of photoreceptors (PRs). Comparative central foveal thickness of patients with AOFVD and SD/FF was significantly different (P < .001). Patients with FF had pigment epithelial deposits and paracentral focal photoreceptor loss. CONCLUSIONS: UHR OCT is a clinically feasible tool for examining intraretinal changes, in particular photoreceptor atrophy in macular dystrophies and, therefore, has the potential to be an adequate imaging system for monitoring the course of disease.

Adult↗

Ultrahigh-resolution and 3-dimensional optical coherence tomography ex vivo imaging of the large and small intestines.

BACKGROUND: Ultrahigh-resolution optical coherence tomography (OCT) has an axial resolution of <5 microm, 2 to 3 times finer than standard OCT. This study investigates ultrahigh-resolution and three-dimensional OCT for ex vivo imaging of the large and small intestines and correlates images with histology. METHODS: Ultrahigh-resolution OCT imaging was performed on fresh surgical specimens from the large and small intestines in the pathology laboratory, and images were correlated with histology. OCT was performed at 1.3-microm wavelength with 4.5-microm axial x 11-microm transverse resolution and at 1.1-microm wavelength with 3.5-microm axial x 6-microm transverse resolution. Three-dimensional OCT also was investigated. RESULTS: Normal and pathologic areas from 23 surgical specimens of the large and small intestines were imaged. Ultrahigh-resolution OCT distinguished the epithelial layer of the mucosa and visualized individual villi, glands, and crypts. Finer transverse resolutions improved visualization of features, e.g., the epithelium, but reduced the depth of field. Architectural distortion of glands from inflammatory and neoplastic processes was observed. Three-dimensional rendering enabled visualization of surface pit pattern and mucosal folds as well as subsurface crypt microstructure. CONCLUSIONS: This study evaluates new OCT technology and can provide a baseline for interpreting future ultrahigh-resolution endoscopic OCT studies.

Adult↗

Ultrahigh-resolution optical coherence tomography in glaucoma.

OBJECTIVE: Optical coherence tomography (OCT) has been shown to be a valuable tool in glaucoma assessment. We investigated a new ultrahigh-resolution OCT (UHR-OCT) imaging system in glaucoma patients and compared the findings with those obtained by conventional-resolution OCT. DESIGN: Retrospective comparative case series. PARTICIPANTS: A normal subject and 4 glaucoma patients representing various stages of glaucomatous damage. TESTING: All participants were scanned with StratusOCT (axial resolution of approximately 10 mum) and UHR-OCT (axial resolution of approximately 3 microm) at the same visit. MAIN OUTCOME MEASURE: Comparison of OCT findings detected with StratusOCT and UHR-OCT. RESULTS: Ultrahigh-resolution OCT provides a detailed cross-sectional view of the scanned retinal area that allows differentiation between retinal layers. These UHR images were markedly better than those obtained by the conventional-resolution OCT. CONCLUSIONS: Ultrahigh-resolution OCT provides high-resolution images of the ocular posterior segment, which improves the ability to detect retinal abnormalities due to glaucoma.

Adult↗

Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.

PURPOSE: To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. METHODS: Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain detection enables dramatic increases in imaging speeds. Three-dimensional OCT retinal imaging is performed in normal human subjects using high-speed ultrahigh-resolution OCT. Three-dimensional OCT data of the macula and optic disc are acquired using a dense raster scan pattern. New processing and display methods for generating virtual OCT fundus images; cross-sectional OCT images with arbitrary orientations; quantitative maps of retinal, nerve fiber layer, and other intraretinal layer thicknesses; and optic nerve head topographic parameters are demonstrated. RESULTS: Three-dimensional OCT imaging enables new imaging protocols that improve visualization and mapping of retinal microstructure. An OCT fundus image can be generated directly from the 3D OCT data, which enables precise and repeatable registration of cross-sectional OCT images and thickness maps with fundus features. Optical coherence tomography images with arbitrary orientations, such as circumpapillary scans, can be generated from 3D OCT data. Mapping of total retinal thickness and thicknesses of the nerve fiber layer, photoreceptor layer, and other intraretinal layers is demonstrated. Measurement of optic nerve head topography and disc parameters is also possible. Three-dimensional OCT enables measurements that are similar to those of standard instruments, including the StratusOCT, GDx, HRT, and RTA. CONCLUSION: Three-dimensional OCT imaging can be performed using high-speed ultrahigh-resolution OCT. Three-dimensional OCT provides comprehensive visualization and mapping of retinal microstructures. The high data acquisition speeds enable high-density data sets with large numbers of transverse positions on the retina, which reduces the possibility of missing focal pathologies. In addition to providing image information such as OCT cross-sectional images, OCT fundus images, and 3D rendering, quantitative measurement and mapping of intraretinal layer thickness and topographic features of the optic disc are possible. We hope that 3D OCT imaging may help to elucidate the structural changes associated with retinal disease as well as improve early diagnosis and monitoring of disease progression and response to treatment.

Anatomy, Cross-Sectional↗

Monitoring osteoarthritis in the rat model using optical coherence tomography.

OBJECTIVE: A need exists for an animal model to assess therapeutics for osteoarthritis (OA) without sacrificing the animal. Our goal is to assess the progression of experimentally induced osteoarthritis in the rat knee joint by monitoring articular cartilage thickness, surface abnormalities, and collagen organization using a new technology known as optical coherence tomography (OCT). DESIGN: OA was generated in Wistar Hanover rats via injection of sodium iodoacetate into the left articular joint of the knee while normal saline was injected as a control in the contralateral right knee. Rats were sacrificed at 1-, 2-, 3-, 4-, and 8-week intervals and the knee joints were subsequently harvested and imaged using normal and polarization sensitive OCT (PS-OCT). Treated knees were compared to normal counterparts in the contralateral leg. Following imaging, knees underwent both routine histological processing and picrosirus staining for organized collagen. RESULTS: OCT images indicate that injection of sodium iodoacetate resulted in a progressive decrease in cartilage thickness and loss of the bone-cartilage interface which correlated with histology. In addition, PS-OCT was able to detect collagen disorganization, an early indicator of OA. CONCLUSIONS: The use of OCT in combination with the induction of OA in rats is a promising new animal model for assessing articular changes with the goal of monitoring therapeutics longitudinally. Future work will extend the model to in vivo assessments.

Animals↗

Assessment of central visual function in Stargardt's disease/fundus flavimaculatus with ultrahigh-resolution optical coherence tomography.

PURPOSE: To assess photoreceptor morphology in patients with Stargardt's disease and fundus flavimaculatus using ultrahigh-resolution optical coherence tomography (UHR-OCT) and correlate it with visual acuity (VA). METHODS: This was a prospective observational case series. Fourteen patients with Stargardt's disease (nine women, five men; average age, 39 years; range, 27-53) were examined. A clinically viable UHR-OCT system employing a new, compact titanium sapphire laser was used, enabling a 3-microm axial resolution in the retina. All patients received a full ophthalmic examination, including fluorescein angiography. Outcome was judged by central transverse photoreceptor loss, central foveal thickness, VA, central atrophy according to fluorescein angiography, and fundus autofluorescence. RESULTS: UHR-OCT was capable of visualizing and quantifying regions of central transverse photoreceptor (PR) loss. All Stargardt patients with central atrophy had a complete loss of the central photoreceptor layer in the foveal region (mean transverse photoreceptor loss, 4390 +/- 2270 microm; range, 530-9240 microm). Patients without clinically evident central atrophy had an intact photoreceptor layer centrally, but had small, focal parafoveal defects. A correlation was detected between VA and transverse PR loss (Spearman rho=-0.60, P=0.03), which was confirmed on logistic regression analysis (R2=0.49, P=0.0001). Central foveal thickness was reduced in patients with Stargardt's disease (85 +/- 40 microm; range, 58-280 microm). The correlation was statistically significant with VA (Spearman rho=0.43, P=0.04), but not with transverse PR loss (Spearman rho=-0.23, P >>0.05). Linear regression analysis showed a statistically significant association of central foveal thickness with VA (R2=0.51, P=0.0001), but not with transverse PR loss (P >>0.05). The extent of atrophy seen in fluorescein angiography correlated with VA and transverse PR loss (Spearman rho=-0.51, P=0.007; Spearman rho=0.77, P=0.0001). Similar correlations were found with the maximum transverse diameter of fundus autofluorescence (Spearman rho=-0.72, P=0.008; Spearman rho=0.77, P=0.003). CONCLUSIONS: Ultrahigh-resolution OCT demonstrates excellent visualization of intraretinal morphology and enables quantification of the photoreceptor layer. Thus, for the first time, an in vivo visualization and quantification of transverse, central photoreceptor loss and correlation with visual function is possible. Lower VA corresponds to a greater transverse photoreceptor loss, which also correlates with the extent of changes seen in fluorescein angiography and in fundus autofluorescence. Furthermore, reduced retinal thickness (i.e., atrophy of retinal layers) does not correlate with the transverse extent of PR loss. Thus, it seems that although there may be progressive atrophy of intraretinal layers, an intact photoreceptor layer leads to better VA. UHR-OCT may present a viable alternative to the assessment of central visual function, due to the easy, objective, and noninvasive data acquisition. Therefore, UHR-OCT could be of future use in judging patients' prognoses in Stargardt's disease.

Adult↗

Macular segmentation with optical coherence tomography.

PURPOSE: To develop a software algorithm to perform automated segmentation of retinal layer structures on linear macular optical coherence tomography (StratusOCT; Carl Zeiss Meditec, Inc., Dublin, CA) scan images and to test its performance in discriminating normal from glaucomatous eyes in comparison with conventional circumpapillary nerve fiber layer (cpNFL) thickness measurement. METHODS: Four layer structures within the retina were defined: the macular nerve fiber layer (mNFL), the inner retinal complex (IRC; retinal ganglion cell [RGC] layer + inner plexiform and nuclear layers), outer plexiform layer (OPL), and outer retinal complex (ORC; outer nuclear layer + photoreceptor layer). Normal and glaucomatous eyes underwent fast macular map and fast NFL OCT scans. Linear macular images were analyzed using the developed algorithm, and the results were compared with the cpNFL thickness measurement. RESULTS: Forty-seven subjects (23 normal and 24 with glaucoma) were analyzed. mNFL, cpNFL, IRC, and the total retinal thicknesses were significantly greater in normal than in glaucomatous eyes (P < or = 0.0002; Wilcoxon), whereas OPL thickness did not show a significant difference (P = 0.46). ORC thickness was significantly greater in glaucomatous than normal eyes (P = 0.035). Areas under the receiver operator characteristic curve (AROCs) for discriminating normal from glaucomatous eyes were highest with mNFL + IRC (0.97) and lowest with OPL (0.56). AROCs for OPL and ORC were significantly smaller than those for mNFL, IRC, mNFL+IRC, and cpNFL (P < or = 0.01). AROCs for IRC, mNFL + IRC, and cpNFL were significantly larger than for retinal thickness (P < or = 0.049). Among the best-performing parameters (mNFL, IRC, mNFL + IRC, and cpNFL) there was no significant difference in AROCs (P > or = 0.15). CONCLUSIONS: The newly developed macular segmentation algorithm described herein demonstrated its ability to quantify objectively the glaucomatous damage to RGCs and NFL and to discriminate between glaucomatous and normal eyes. Further algorithm refinement and improvements in resolution and image quality may yield a more powerful methodology for clinical glaucoma evaluation.

Algorithms↗

Using optical coherence tomography to guide articular cartilage ablation.

Current clinical imaging technologies are not capable of accurately resolving the microscopic components of articular cartilage. Optical coherence tomography (OCT) is a recently developed imaging modality analogous to ultrasound--OCT measures backreflection of infrared light instead of sound. In the study reported here, we wanted to determine the efficacy of OCT for monitoring cartilage laser ablation. Real-time imaging was conducted on bovine cartilage ablated by an argon laser in vitro. Image sequences were generated illustrating the extent of tissue degradation postablation. The images accurately correlated with histology. These results indicate that current ablation procedures could benefit from OCT guidance.

Animals↗

Speckle reduction in optical coherence tomography images by use of a spatially adaptive wavelet filter.

A spatially adaptive two-dimensional wavelet filter is used to reduce speckle noise in time-domain and Fourier-domain optical coherence tomography (OCT) images. Edges can be separated from discontinuities that are due to noise, and noise power can be attenuated in the wavelet domain without significantly compromising image sharpness. A single parameter controls the degree of noise reduction. When this filter is applied to ophthalmic OCT images, signal-to-noise ratio improvements of >7 dB are attained, with a sharpness reduction of <3%.

Algorithms↗

High-resolution imaging of the thyroid gland using optical coherence tomography.

BACKGROUND: Current diagnostic imaging modalities of the thyroid gland cannot reliably distinguish benign from malignant lesions, primarily because of their inability to visualize microscopic structure. A high-resolution imaging technique capable of examining thyroid tissue architectural morphology in real time is needed. Optical coherence tomography (OCT) has been shown to achieve high resolutions approaching the cellular range (1-15 microm). The feasibility of optical coherence tomography for imaging thyroid tissue was explored ex vivo on the human thyroid gland. METHODS: High-resolution OCT was performed in real time at 2 to 4 frames per second on three postmortem and 15 surgically excised thyroid glands containing normal, hyperplastic, and neoplastic tissue. OCT images acquired were compared with those obtained using standard histopathologic methods. RESULTS: The microstructure of the normal thyroid gland, including colloid-filled follicles as small as 15 microm and their supporting stroma, was clearly identified. OCT images of degenerative, hyperplastic, adenomatous, and malignant change within the thyroid gland were shown to correlate well with corresponding histopathologic findings. CONCLUSIONS: The ability of OCT to image thyroid tissue microarchitecture makes it a potentially powerful technology that can be used to assess the thyroid gland at a resolution greater than currently available clinical imaging modalities.

Adult↗

Optical coherence tomography (OCT) macular and peripapillary retinal nerve fiber layer measurements and automated visual fields.

PURPOSE: To investigate the structure-function relationship between optical coherence tomography (OCT) macular retinal and peripapillary nerve fiber layer (NFL) thickness and automated visual field (VF) findings. DESIGN: Cross-sectional observational study. METHODS: Retrospective institutional study where 150 consecutive eyes (101 subjects) from a glaucoma service were included. All the participants had full ophthalmic evaluation, VF testing and prototype OCT scanning at the same visit. Orthogonal OCT macular analysis was obtained to maximize the sampling of the area of interest. Pearson age-adjusted correlation was determined between macular retinal thickness and peripapillary NFL thickness. Area under the receiver operator characteristics (AROC) curves for the association between macular retinal thickness and peripapillary NFL thickness and VF findings were calculated in a subgroup of eyes without VF defect and eyes with VF defect confined to one hemifield. RESULTS: The correlation between macular retinal and peripapillary NFL measurements ranged between r =.27 to.54 for quadrants,.44 to.55 for hemiretina, and.52 for the overall mean. Areas under the receiver operator characteristics for macular thickness were higher in areas corresponding to the VF defect location than the noncorresponding locations. Areas under the receiver operator characteristics for peripapillary NFL thickness were higher than for the macular retinal thickness. Including both macular retinal thickness and peripapillary NFL thickness measurements in the logistic regression model yielded AROCs (range:.69 -.77) similar to those found for the peripapillary NFL alone. CONCLUSION: Macular retinal thickness, as measured by OCT, was capable of detecting glaucomatous damage and corresponded with peripapillary NFL thickness; however, peripapillary NFL thickness had higher sensitivity and specificity for the detection of VF abnormalities.

Aged↗

Comparison of ultrahigh- and standard-resolution optical coherence tomography for imaging macular hole pathology and repair.

PURPOSE: To compare ultrahigh-resolution optical coherence tomography (UHR-OCT) technology to a standard-resolution OCT instrument for the imaging of macular hole pathology and repair; to identify situations where UHR-OCT provides additional information on disease morphology, pathogenesis, and management; and to use UHR-OCT as a baseline for improving the interpretation of the standard-resolution images. DESIGN: Observational and interventional case series. PARTICIPANTS: Twenty-nine eyes of 24 patients clinically diagnosed with macular hole in at least one eye. METHODS: A UHR-OCT system has been developed and employed in a tertiary-care ophthalmology clinic. Using a femtosecond laser as the low-coherence light source, this new UHR-OCT system can achieve an unprecedented 3-mum axial resolution for retinal OCT imaging. Comparative imaging was performed with UHR-OCT and standard 10-mum resolution OCT in 29 eyes of 24 patients with various stages of macular holes. Imaging was also performed on a subset of the population before and after macular hole surgery. MAIN OUTCOME MEASURES: Ultrahigh- and standard-resolution cross-sectional OCT images of macular hole pathologies. RESULTS: Both UHR-OCT and standard-resolution OCT exhibited comparable performance in differentiating various stages of macular holes. The UHR-OCT provided improved imaging of finer intraretinal structures, such as the external limiting membrane and photoreceptor inner segment (IS) and outer segment (OS), and identification of the anatomy of successful surgical repair. The improved resolution of UHR-OCT enabled imaging of previously unidentified changes in photoreceptor morphology associated with macular hole pathology and postoperative repair. Visualization of the junction between the photoreceptor IS and OS was found to be an important indicator of photoreceptor integrity for both standard-resolution and UHR-OCT images. CONCLUSIONS: Ultrahigh-resolution optical coherence tomography improves the visualization of the macular hole architectural morphology. The increased resolution of UHR-OCT enables the visualization of photoreceptor morphology associated with macular holes. This promises to lead to a better understanding of the pathogenesis of macular holes, the causes of visual loss secondary to macular holes, the timing of surgical repair, and the evaluation of postsurgical outcome. Ultrahigh-resolution optical coherence tomography imaging of macular holes that correspond to known alterations in retinal morphology can be used to interpret retinal morphology in UHR-OCT images. Comparisons of UHR-OCT images with standard-resolution OCT images can establish a baseline for the better interpretation of clinical standard-resolution OCT images. The ability to visualize photoreceptors and their integrity or impairment is an indicator of macular hole progression and surgical outcome.

Aged↗

Stage 0 macular holes: observations by optical coherence tomography.

OBJECTIVE: To introduce the concept of a stage 0 macular hole based on optical coherence tomographic observations of the vitreoretinal interface in fellow eyes of patients with unilateral idiopathic macular holes, and to evaluate the subsequent risk of progression to a full-thickness macular hole. DESIGN: Retrospective observational case series. PARTICIPANTS: Ninety-four patients with a unilateral stage 2, 3, or 4 full-thickness macular hole. METHODS: The medical records of patients with a unilateral macular hole diagnosed between 1994 and 2000 at the New England Eye Center were reviewed. MAIN OUTCOME MEASURE: Development of a full-thickness macular hole in the fellow eye on biomicroscopic fundoscopy or optical coherence tomography (OCT). RESULTS: In 27 (28.7%) of 94 clinically normal fellow eyes, OCT detected an abnormality of the vitreoretinal interface but normal foveal anatomy. The vitreoretinal abnormalities were further subclassified into severe (4 eyes), moderate (8 eyes), and mild (15 eyes) based on the intensity and morphology of the OCT signal. One of the 4 (25%) severe cases progressed to a full-thickness macular hole, 4 of the 8 (50%) moderate cases became full-thickness macular holes, and no (0%) mild cases progressed to a full-thickness macular hole. Severe and moderate eyes seemed to share characteristic features on OCT that increased their risk of macular hole development (stage 0 macular hole). The macular hole-free survival at 48 months was 94% for stage 0-negative patients, versus 54% for stage 0-positive patients. Univariate analysis revealed that the presence of a stage 0 macular hole was significantly associated with an almost 6-fold increase in the risk of macular hole formation (relative risk: 5.8, 95% confidence interval: 1.16-28.61, P = 0.03). CONCLUSIONS: A stage 0 macular hole has a normal biomicroscopic appearance clinically, but has salient features on OCT as a result of oblique vitreous traction. Optical coherence tomographic findings consist of a normal foveal contour and normal retinal thickness and must include the presence of a preretinal, minimally reflective, thin band inserting obliquely on at least one side of the fovea. The presence of a stage 0 macular hole in the fellow eye is a significant risk factor for the development of a second macular hole.

Adult↗

Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

PURPOSE: The measurement reproducibility of the third generation of commercial optical coherence tomography, OCT-3 (StratusOCT, software ver. A2, Carl Zeiss Meditec Inc., Dublin, CA) was investigated. The nerve fiber layer (NFL) thickness, macula thickness map, and optic nerve head (ONH) parameters in normal eyes were studied. METHODS: Ten normal subjects were imaged six times (three before and three after dilation) per day, and the series was repeated on three different days. The order of the scans before pupil dilation was randomized in each of the 3 days of scanning. After pupil dilation, the scans were also randomized in each of the 3 days of scanning. Each series was performed separately for standard-density (128 A-scans per macular and ONH image and 256 A-scans per NFL image) and high-density (512 A-scans per image for all three scan types) scanning. RESULTS: The mean macular thickness was 235 +/- 9.8 micro m. A-scan density (or image acquisition speed) had a statistically significant effect (P < 0.05) on the reproducibility of the mean macular thickness, macular volume, and a few sectors of the macular map. No significant dilation effect was found for any of the macular parameters. The best intraclass correlation coefficient (ICC; 94%) for macular scans was found for dilated high-density scanning, with an intervisit SD of 2.4 micro m and an intravisit SD of 2.2 micro m. The mean NFL thickness for standard scanning was 98 +/- 9 micro m. NFL reproducibility showed mixed results and had interactions between scan density and dilation for some parameters. For most of the NFL parameters, reproducibility was better with dilated standard-density scanning. The mean NFL thickness ICC for dilated standard scanning was 79%, with an intervisit SD of 2.5 micro m and an intravisit SD of 1.6 micro m. For the ONH analysis, the reproducibility was better for dilated standard-density scanning for almost all the parameters, except for disc area, horizontal integrated rim volume, and vertical integrated rim area, which were better before dilation. The best reproducibility was found for cup-to-disc ratio (ICC = 97%, with intervisit SD of 0.04 micro m and intravisit SD of 0.02 micro m). CONCLUSIONS: StratusOCT demonstrated reproducible measurements of NFL thickness, macular thickness, and optic nerve head parameters. The best reproducibility was found for dilated standard scanning for NFL and ONH parameters and for dilated high-density scanning for macular parameters.

Adult↗

High-performance, compact, prismless, low-threshold 30-MHz Ti:Al2O3 laser.

We describe the design and operation of a compact femtosecond Ti:Al2O3 laser based on a novel multipass cavity (MPC) design. The laser is all solid state, has prismless dispersion compensation with double-chirped mirrors, and uses a tight-focusing geometry to facilitate efficient low-threshold operation. We increase output pulse energies by extending the resonator length with a compact, scalable MPC, which preserves the characteristics of the Gaussian beam for the short cavity. Although the effective cavity length is approximately 5 m, an extremely compact laser that measures only 30 cm x 45 cm is achieved. With only 1.5 W of pump power, the laser generates 23-fs pulses at a repetition rate of 31.25 MHz and with 88 mW of average output power, corresponding to 2.8 nJ of pulse energy.

Journal Article↗

High-speed path-length scanning with a multiple-pass cavity delay line.

Techniques for high-speed delay scanning are important for low-coherence interferometry, optical coherence tomography, pump probe measurements, and other applications. We demonstrate a novel scanning delay line using a multiple-pass cavity. Differential delays are accumulated with each pass so that millimeter delays can be generated with tens of micrometer mirror displacements. With special design criteria, misalignment sensitivity can be dramatically reduced. The system is demonstrated to scan 6 m/s at 2-kHz repetition rates. Real-time optical coherence tomography imaging with 500 pixel images at four frames/s is performed. Using a Cr:forsterite laser source, we obtained axial image resolutions of 6 microm with 92-dB sensitivity.

Models, Theoretical↗

Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography.

OBJECTIVES: To demonstrate a new generation of ophthalmic optical coherence tomography (OCT) technology with unprecedented axial resolution for enhanced imaging of intraretinal microstructures and to investigate its clinical feasibility to visualize intraretinal morphology of macular pathology. METHODS: A clinically viable ultrahigh-resolution ophthalmic OCT system was developed and used in clinical imaging for the first time. Fifty-six eyes of 40 selected patients with different macular diseases including macular hole, macular edema, age-related macular degeneration, central serous chorioretinopathy, epiretinal membranes, and detachment of pigment epithelium and sensory retina were included. OUTCOME MEASURES: Ultrahigh-resolution tomograms visualizing intraretinal morphologic features in different retinal diseases. RESULTS: An axial image resolution of approximately 3 micro m was achieved in the eyes examined, nearly 2 orders of magnitude better than conventional ophthalmic ultrasound. Ultrahigh-resolution OCT images provided additional diagnostically important information on intraretinal morphologic features that could not have been obtained by standard techniques. CONCLUSIONS: Ultrahigh-resolution ophthalmic OCT enables unprecedented visualization of intraretinal morphologic features and therefore has the potential to contribute to a better understanding of ocular pathogenesis, as well as to enhance the sensitivity and specificity for early ophthalmic diagnosis and to monitor the efficacy of therapy. This study establishes a baseline for the interpretation of ultrahigh-resolution ophthalmic OCT imaging of macular diseases.

Adult↗