Search PubMed⌕ Search

Biomedical subjects

James F Winchester

Publications and source records attributed to James F Winchester.

At least 19 recordsLinked to original sources

Guidelines for guidelines.

Practice guidelines are proliferating in medicine. In addition to methodological problems that cause guidelines to be outdated rapidly, they are plagued by conflicts of interest. They are largely consensus opinions of panels of experts, most of whom are supported by industry. Professional societies, health insurers, Centers for Medicare and Medicaid Services, and dialysis providers also benefit from guidelines. Little attention is paid to the potential for harm to patients, and to the profession of medicine, from the widespread use of guidelines.

Centers for Medicare and Medicaid Services, U.S.↗

The 2006 K/DOQI guidelines for peritoneal dialysis adequacy are not adequate.

The 2006 National Kidney Foundation K/DOQI guidelines have lowered the peritoneal dialysis adequacy standard of Kt/V(urea) from 2.1 to 1.7 in anuric patients, largely based on the patient survival results of 2 clinical trials in Mexico and Hong Kong. It is our contention that the guidelines may be misleading since they have chosen to ignore the bias in these trials and have ignored the adverse outcomes in control groups in the trials on which the guidelines are based, as well as the body size of the subjects in these trials. Body size has changed in the US and Canada over the last few decades and there are similar changes worldwide. We suggest that the minimum targets for peritoneal dialysis be reinstituted at the previous standard Kt/V(urea) of 2.0.

Body Mass Index↗

The potential application of sorbents in peritoneal dialysis.

Sorbents have been designed to remove small and middle molecular weight toxins, including low molecular weight proteins, peptides, cytokines and chemokines in patients undergoing renal replacement therapy. Sorbents assist the process of peritoneal dialysate regeneration and have the potential to improve the efficiency of continuous flow peritoneal dialysis.

Humans↗

Intradialytic blood volume monitoring in ambulatory hemodialysis patients: a randomized trial.

Complications related to inadequate volume management are common during hemodialysis. This trial tested the hypothesis that availability of an intradialytic blood volume monitoring (IBVM) device improves fluid removal, reducing morbidity. A six-center, randomized trial with 6 mo of intervention comparing IBVM using Crit-Line versus conventional clinical monitoring was conducted. The average rate of non-access-related hospitalizations was compared across treatment groups using Poisson regression. Mortality analysis used the Kaplan Meier method. A total of 227 patients were randomized to Crit-Line, and 216 were randomized to conventional monitoring. Both groups had similar baseline characteristics. During the study, no differences in weight, BP, or number of dialysis-related complications were observed. There were 120 and 81 non-access-related hospitalizations in the Crit-Line and conventional monitoring groups. The adjusted risk ratio for non-access-related and access-related hospitalization was 1.61 (95% confidence interval 1.15 to 2.25; P = 0.01) and 1.52 (95% confidence interval 1.02 to 2.28; P = 0.04) for the Crit-Line monitoring group. Mortality was 8.7% in the Crit-Line monitoring group and 3.3% in the conventional group (P = 0.021). Standardized mortality ratios comparing the Crit-Line and conventional monitoring groups to the prevalent hemodialysis population were 0.77 (NS) and 0.26 (P < 0.001). Hospitalization rates were 1.51 and 1.03 events/yr in the Crit-Line and standard monitoring groups, compared with 2.01 for the prevalent hemodialysis population. IBVM was associated with higher nonvascular and vascular access-related hospitalizations and mortality compared with conventional monitoring. The atypically low hospitalization and mortality rates for the conventional monitoring group suggest that these findings should be generalized to the US hemodialysis population with caution.

Adult↗

Absence of NF-kappaB activation by a new polystyrene-type adsorbent designed for hemoperfusion.

AIM: The aim of the study was to evaluate biocompatibility of anew polystyrene-type adsorbent (BetaSorb) designed for hemoperfusion, using second-level biomolecular analyses. The device has recently been developed to enhance beta2-microglobulin removal during hemodialysis. Molecular structure and chemical modifications of the surface beads of this cartridge should prevent exposure of dense hydrophobic surface sites to proteins, and avoid the major drawbacks of previous polystyrene-type adsorbent materials. METHODS: Whole blood of healthy donors was incubated in sterile minicolumns packed with BetaSorb Cuprophan, Hemophan, polysulfone and cellulose acetate. In parallel experiments, whole blood was recirculated for 180 min in a sham dialysis circuit equipped with the study sorbent or Hemophan or polysulfone. Biocompatibility was assessed by means of new biomolecular approaches focused on nuclear factor kappaB (NF-kappaB) activation (assessed by electrophoretic mobility shift assay), TNF-alpha and IL-1beta gene expression (evaluated by real-time PCR), TNF-alpha and IL-1beta production (measured by Western blot assay and ELISA), nitric oxide (NO) generation (detected by electron paramagnetic resonance), free oxygen radical production (by chemiluminescence in a biological assay) and the generation of the complement breakdown product C3d. RESULTS: In coincubation experiments, 5-min contact with any dialysis device, but BetaSorb, was enough to induce activation of NF-kappaB. The amount of TNF-alpha precursor form was found to increase after 5 min of exposure to each tested polymer, but no traces of mature forms of TNF-alpha or IL-1beta were detected in in vitro experimental conditions using healthy blood. NO and free oxygen radical generation were significantly lower in blood samples exposed to BetaSorb than in control dialysis devices. C3d levels were found to be increased with Hemophan, unaffected by polysulfone, and remarkably decreased with the BetaSorb device. In the sham hemodialysis experiments, NF-kappaB activation and C3d and NO profiles were similar to direct incubation experiments. Compared to basal levels, quantitation of TNF-alpha and IL-1beta mRNA revealed a 15- and 9-fold increase, respectively, in samples exposed to Hemophan for 180 min. CONCLUSIONS: The new BetaSorb device not only appears to be highly biocompatible, but shares properties that make it probably able to interfere with the activation of the inflammatory state.

Adsorption↗

Sorbents in acute renal failure and end-stage renal disease: middle molecule and cytokine removal.

Renal replacement therapy in acute renal failure (ARF) and chronic renal failure (end-stage renal disease; ESRD) has been based on the use of modifications of dialysis (continuous arteriovenous hemofiltration and hemodiafiltration) to remove middle-molecular-weight toxins, consisting of low-molecular-weight proteins and peptides (LMWP) and cytokines involved in inflammation. High-flux dialyzers are not efficient at removing LMWP, and for this reason, sorbents have been studied to augment or replace dialysis. Removal of LMWP such as beta2-microglobulin, leptin, complement factor D, angiogenin and cytokines such as interleukin (IL)-1, IL-6, IL-10, IL-18 and tumor necrosis factor-alpha has been established in animal models of sepsis and in ESRD patients using sorbents. Sorbent devices added to hemodialysis, or the use of such devices alone in inflammatory states, including sepsis, ARF, cardiopulmonary bypass, pre-explantation of donor organs and ESRD, are being studied.

Acute Kidney Injury↗

Effect of a novel adsorbent on cytokine responsiveness to uremic plasma.

BACKGROUND: Middle molecules such as beta2-microglobulin (beta2M) and advanced glycation end products (AGE)-modified proteins contribute to inflammation in uremia. The BetaSorb column is a new adsorptive device, which contains copolymeric beads, suitable for removal of beta2M and other middle molecules. We assessed the effect of this column on the bioreactivity of uremic plasma, as measured by cytokine responsiveness. METHODS: Uremic plasma was perfused in vitro through the column (10 mL/min) and samples were collected after 10 to 30 passes. Endotoxin-stimulated tumor necrosis factor-alpha (TNF-alpha) and interleukin-10 (IL-10) production by THP-1-derived monocytes was measured following brief exposure to uremic plasma. beta2M levels were measured. The contribution of AGE-modified proteins to the bioreactivity of uremic plasma was explored. RESULTS: TNF-alpha and IL-10 production markedly decreased after 30 passes (629 +/- 78 vs. 144 +/- 62 pg/mL; 207 +/- 25 vs. 117 +/- 23 pg/mL; P=0.04). The column removed beta2M efficiently with a marked decline in plasma levels by 99% after 30 passes. Neutralization of AGE receptor (RAGE) resulted in a further reduction in the bioreactivity of uremic plasma. This was observed with nonperfused, as well as perfused, uremic plasma, suggesting that AGE-modified proteins were biologically active and still present after perfusion. CONCLUSION: The sorbent beads removed uremic solute(s) that prime monocytes to enhanced cytokine production. Removal of beta2M was efficient, and of native and AGE-modified middle molecules likely.

Antibodies↗

Beta-2 microglobulin in ESRD: an in-depth review.

Beta-2 microglobulin is the most widely studied low-molecular-weight protein in end-stage renal disease. It is known to cause dialysis-related amyloidosis (DRA), by virtue of its retention when renal function fails, its deposition in tissues, its aggregation into fibrils, and its ability to become glycosylated. The onset of DRA may be protracted by the use of noncellulosic membranes, especially when high-volume hemodiafiltration is used in the treatment of renal failure. Adsorptive methods have been developed to improve the removal of beta-2 microglobulin. There seems to be a relative risk reduction in mortality when patients are treated with dialysis membranes that have a higher clearance of beta-2 microglobulin.

Amyloidosis↗

Middle molecules and small-molecular-weight proteins in ESRD: properties and strategies for their removal.

Molecular weight has traditionally been the parameter most commonly used to classify uremic toxins, with a value of approximately 500 Da frequently used as a demarcation point below which the molecular weights of small nitrogenous waste products fall. This toxin group, the most extensively studied from a clinical perspective, is characterized by a high degree of water solubility and the absence of protein binding. However, uremia is mediated by the retention of a plethora of other compounds having characteristics that differ significantly from those of the previously mentioned group. As opposed to the relative homogeneity of the nitrogenous metabolite class, other uremic toxins collectively are a very heterogeneous group, not only with respect to molecular weight but also other characteristics, such as protein binding and hydrophobicity. A recently proposed classification scheme by the European Uraemic Toxin Work Group subdivides the remainder of molecules into 2 categories: protein-bound solutes and middle molecules. For the latter group, the Work Group proposes a molecular weight range (500-60,000 Da) that incorporates many toxins identified since the original middle molecule hypothesis, for which the upper molecular weight limit was approximately 2,000 Da. In fact, low-molecular-weight peptides and proteins (LMWPs) comprise nearly the entire middle molecule category in the new scheme. The purpose of this article is to provide an overview of the middle molecule class of uremic toxins, with the focus on LMWPs. A brief review of LMWP metabolism under conditions of normal (and in a few cases, abnormal) renal function will be presented. The physical characteristics of several LMWPs will also be presented, including molecular weight, conformation, and charge. Specific LMWPs to be covered will include beta 2-microglobulin, complement proteins (C3a and Factor D), leptin, and proinflammatory cytokines. The article will also include a discussion of the treatment-related factors influencing dialytic removal of middle molecules. Once these factors, which include membrane characteristics, protein-membrane interactions, and solute removal mechanisms, are discussed, an overview of the different therapeutic strategies used to enhance clearance of these compounds is provided.

Absorption↗

Sorbents in acute renal failure and the systemic inflammatory response syndrome.

Renal replacement therapy in acute renal failure is currently focused on the use of modifications of dialysis (continuous arteriovenous hemofiltration and hemodiafiltration) to remove middle molecular weight toxins, consisting of small proteins, and cytokines involved in the systemic inflammatory response syndrome (SIRS). Conventional high-flux dialyzers are not efficient at removing these molecules, prompting the investigation of sorbents to augment or replace dialysis. Sorbents have been developed to modulate SIRS by targeting cytokines such as IL-1, IL-6, IL-10, IL-18 and TNF, among others. Extensive pre-clinical studies are underway to demonstrate the clinical utility and safety of either adding sorbent hemoadsorption devices to hemodialysis, or the use of such devices alone in SIRS, sepsis, acute renal failure, cardiopulmonary bypass and end-stage renal disease.

Acute Kidney Injury↗

Dialysis and hemoperfusion in poisoning.

The treatment of serious drug or chemical poisoning relies mostly on the use of standard intensive care measures. Supplementation of intensive care with dialysis and hemoperfusion may be necessary at times to remove the intoxicant in seriously ill patients. Factors governing drug and chemical removal by dialysis and hemoperfusion are discussed, and guidelines given when to employ these techniques. Tables of drugs removed by both techniques are given for guidance. These tables will be updated regularly on the Advances in Renal Replacement Therapy website.

Hemoperfusion↗

Sorbent hemoperfusion in end-stage renal disease: an in-depth review.

The excessive mortality in dialysis patients has rekindled interest in research of adsorbent removal of nontraditional uremic toxins. Middle-molecular-weight substances, predominantly small proteins, have been correlated with specific uremic syndromes and implicated in the uremic state. New developments in polymer technology and carbon pyrrolization techniques have produced sorbents possessing mesopores of sufficient size to trap middle-molecular-weight substances. Clinical application of hemoperfusion devices containing these sorbents is early in its development. Studies related to hemoperfusion in uremia are discussed in detail.

Hemoperfusion↗

The next step from high-flux dialysis: application of sorbent technology.

The current foci of renal replacement therapy with dialysis are middle molecular weight toxins, consisting of small proteins, polypeptides and products of glycosylation and lipoxygenation. Conventional high-flux dialysis is not efficient at removing these molecules, explaining the increased interest in using sorbents to supplement dialysis techniques. Prototype biocompatible sorbents have been developed and investigated for middle molecule removal; these have been shown, in man, to remove beta(2)-microglobulin, angiogenin, leptin, cytokines and other molecules, without reducing platelets and leukocytes. Extensive clinical studies are underway to demonstrate the clinical utility and safety of adding routinely a sorbent hemoperfusion device to hemodialysis.

Adsorption↗

Special clinical problems in geriatric patients.

The elderly dialysis patient presents several challenges to the nephrologist. Concurrent illnesses may complicate management, disabilities may interfere with mobility, hearing, and vision, and depression and mental incompetence may be present. For these reasons the physician and health care team should adopt a broad treatment plan, using expert help if needed in managing the patient and involving family members, clergy, and friends. While lifestyle changes are inevitable for the elderly with initiation of dialysis, satisfactory outcomes are possible. In the event of overwhelming illness and the patient's perception of the futility of continuation of dialysis, cessation of dialysis must be approached in a humane, considerate, and compassionate manner.

Aged↗

Extracorporeal strategies for the removal of middle molecules.

Uremic toxins with a molecular weight of less than 500 Da are classified as small nitrogenous waste products. They are highly water soluble, relatively homogeneous, and have no protein binding. Other uremic retention toxins differ significantly from the small nitrogenous metabolite class in molecular weight, heterogeneity, protein binding, and hydrophobicity. The European Uremic Toxin Work Group subdivided molecules into two categories: protein-bound solutes and middle molecules. Middle molecules were defined as toxins in the molecular weight range of 500-60,000 Da, which exceeds the molecular weight of 2000 Da defined in the original middle molecule hypothesis. Under this new proposed definition, most of these middle molecules are low molecular weight peptides and proteins (LMWPs). This concise review focuses on LMWPs. The metabolism of LMWPs is described, including molecular weight, physical conformation, and charge. Factors influencing dialytic removal of LMWPs such as membrane characteristics, protein-membrane interactions, and solute removal mechanisms, as well as strategies to enhance clearance of these compounds are discussed.

Humans↗