Search PubMed⌕ Search

Biomedical subjects

James D Thomas

Publications and source records attributed to James D Thomas.

At least 127 records · Page 7Linked to original sources

Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study.

OBJECTIVES: The aim of this study was to use real-time three-dimensional echocardiography (3DE) to investigate the quantitative relation between minimal left ventricular (LV) outflow tract area (A(LVOT)) and maximal LV outflow tract (LVOT) velocity in patients with hypertrophic obstructive cardiomyopathy (HCM). BACKGROUND: In patients with HCM, LVOT velocity should change inversely with minimal A(LVOT) unless LVOT obstruction reduces the pumping capacity of the ventricle. METHODS: A total of 25 patients with HCM with systolic anterior motion (SAM) of the mitral valve leaflets underwent real-time 3DE. The smallest A(LVOT) during systole was measured using anatomically oriented two-dimensional "C-planes" within the pyramidal 3DE volume. Maximal velocity across LVOT was evaluated by two-dimensional Doppler echocardiography (2DE). For comparison with 3DE A(LVOT), the SAM-septal distance was determined by 2DE. RESULTS: Real-time 3DE provided unique information about the dynamic SAM-septal relation during systole, with A(LVOT) ranging from 0.6 to 5.2 cm(2) (mean: 2.2 +/- 1.4 cm(2)). Maximal velocity (v) correlated inversely with A(LVOT) (v = 496 A(LVOT)(-0.80), r = -0.95, p < 0.001), but the exponent (-0.80) was significantly different from -1.0 (95% confidence interval: -0.67 to -0.92), indicating a significant impact of small A(LVOT) on the peak LVOT flow rate. By comparison, the best correlation between velocity and 2DE SAM-septal distance was significantly (p < 0.01) poorer at -0.83, indicating the superiority of 3DE for assessing A(LVOT). CONCLUSIONS: Three-dimensional echocardiography-measured A(LVOT) provides an assessment of HCM geometry that is superior to 2DE methods. These data indicate that the peak LVOT flow rate appears to be significantly decreased by reduced A(LVOT). Real-time 3DE is a potentially valuable clinical tool for assessing patients with HCM.

Adult↗

Doppler-derived myocardial systolic strain rate is a strong index of left ventricular contractility.

BACKGROUND: Myocardial fiber strain is directly related to left ventricular (LV) contractility. Strain rate can be estimated as the spatial derivative of velocities (dV/ds) obtained by tissue Doppler echocardiography (TDE). The purposes of the study were (1) to determine whether TDE-derived strain rate may be used as a noninvasive, quantitative index of contractility and (2) to compare the relative accuracy of systolic strain rate against TDE velocities alone. METHODS AND RESULTS: TDE color M-mode images of the interventricular septum were recorded from the apical 4-chamber view in 7 closed-chest anesthetized mongrel dogs during 5 different inotropic stages. Simultaneous LV volume and pressure were obtained with a combined conductance-high-fidelity pressure catheter. Peak elastance (Emax) was determined as the slope of end-systolic pressure-volume relationships during caval occlusion and was used as the gold standard of LV contractility. Peak systolic TDE myocardial velocities (Sm) and peak (epsilon'(p)) and mean (epsilon'(m)) strain rates obtained at the basal septum were compared against Emax by linear regression. Emax as well as TDE systolic indices increased during inotropic stimulation with dobutamine and decreased with the infusion of esmolol. A stronger association was found between Emax and epsilon'(p) (r=0.94, P<0.01, y=0.29x+0.46) and epsilon'(m) (r=0.88, P<0.01) than for Sm (r=0.75, P<0.01). CONCLUSIONS: TDE-derived epsilon'(p) and epsilon'(m) are strong noninvasive indices of LV contractility. These indices appear to be more reliable than S(m), perhaps by eliminating translational artifact.

Animals↗

Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis.

BACKGROUND: Long-term stability of the hemodynamic performance of commercially available Carpentier-Edwards stented bovine pericardial aortic bioprostheses (Perimount RSR) is unknown. To anticipate the fate of this bioprosthesis, we examined its hemodynamic performance up to 17 years using echocardiographic studies in a Premarket Approval cohort. METHODS: Of 267 patients at four institutions in the Premarket Approval cohort, 85 had a total of 168 echocardiographic studies during a 17-year period of yearly follow-up examinations. These were reviewed and quantified in a core echocardiographic facility. Longitudinal data analysis was used to account for repeated, censored data. RESULTS: Mean transvalvular gradient was inversely related to prosthesis size (p = 0.01), and possibly (p = 0.06) increased somewhat during the first 10 years of follow-up, then stabilized. Effective orifice area was larger in larger valve sizes (p = 0.01), declined somewhat during the first 10 years, and then began to increase again. Ejection fraction declined minimally (p = 0.2). In contrast to the rather stable hemodynamics, aortic regurgitation steadily increased from none to 1 to 2+ (p = 0.005), but rarely (< 10% at 17 years) progressed to 3+ or 4+. CONCLUSIONS: The Carpentier-Edwards aortic pericardial bioprosthesis can be anticipated to have an acceptable long-term transvalvular gradient and effective orifice size that will change trivially up to 17 years after implantation. Mild aortic regurgitation will develop progressively. This anticipated hemodynamic resilience supports continued clinical use of the Perimount Carpentier-Edwards bovine pericardial stented bioprosthesis.

Adult↗

Accessory fibrous band causing anterior mitral valve leaflet restriction.

A 20-year-old woman with neurofibromatosis (type I), presented with heart failure due to severe mitral regurgitation. Echocardiography and surgery revealed an accessory fibrous band causing anterior mitral valve leaflet restriction. Resection of the fibrous band and correction of the mitral valve using the accessory fibrous band was performed. The further postoperative course was uncomplicated.

Adult↗

Noninvasive assessment of cardiac resynchronization therapy for congestive heart failure using myocardial strain and left ventricular peak power as parameters of myocardial synchrony and function.

INTRODUCTION: Although invasive studies have shown that cardiac resynchronization therapy by biventricular pacing improves left ventricular (LV) function in selected heart failure patients, it is impractical to apply such techniques in the clinical setting. The aim of this study was to assess the acute effects of cardiac resynchronization therapy by noninvasive techniques. METHODS AND RESULTS: Twenty-two patients enrolled in the InSync trial (age 64 +/- 9 years, 18 men and 4 women; all with ejection fraction < 35% and QRS > 130 msec) were studied 1 to 12 months after pacemaker implantation during pacing, and while ventricular pacing was inhibited. Regional myocardial strains of the interventricular septum, LV free wall, and right ventricular free wall were derived from color Doppler tissue echocardiography. Peak power index was calculated as a product of simultaneously recorded noninvasive blood pressure and pulse-wave (PW) Doppler velocity of the LV outflow tract. The Z ratio (sum of LV ejection and filling times divided by RR interval) and tei index were calculated from PW Doppler data. During pacing, overall regional strain improved (P = 0.01), while the LV strain coefficient of variation decreased from 2.7 +/- 2.4 to 1.3 +/- 0.7 (P = 0.009). Additionally, peak power index improved from 84 +/- 24 to 94 +/- 27 cm x mmHg/sec (P = 0.004). The Z ratio increased from 0.71 +/- 0.08 to 0.78 +/- 0.07 (P = 0.0005), while the tei index decreased from 0.86 +/- 0.33 to 0.59 +/- 0.16 (P = 0.0002). CONCLUSION: Using novel noninvasive indices, we demonstrated that cardiac resynchronization therapy improves LV performance.

Aged↗

Does rapid volume loading during transesophageal echocardiography differentiate constrictive pericarditis from restrictive cardiomyopathy?

BACKGROUND: Respiratory variation of the pulmonary venous (PV) peak flow velocities can be used to distinguish constrictive pericarditis (constriction) from restrictive cardiomyopathy (restriction). Rapid volume expansion has been used successfully to enhance diastolic pressure equalization in occult constriction. The effect of volume on the respiratory variation in constriction has not been studied previously. This study assessed the utility of volume in enhancing the PV respiratory variation of constriction to further separate it from restriction. METHODS: The study population consisted of 15 patients referred to the echocardiography laboratory for further evaluation of clinically suspected diastolic dysfunction. Pulsed-Doppler transesophageal echocardiography (TEE) of the left or right upper pulmonary vein and mitral inflow was performed with respiratory monitoring before and after infusion of 1 liter of normal saline over 5 to 10 minutes. The classification of patients as constriction (n = 8) or restriction (n = 7) was confirmed independently by cardiac catheterization or surgery. Peak velocities of the PV systolic and diastolic waves and the mitral inflow E were measured during inspiration and expiration. A mean of 3-6 respiratory cycles was obtained for each value before and after volume loading. The percent change from expiration to inspiration (%E) was calculated using the formula %E = expiration - inspiration / expiration. RESULTS: At baseline, patients with constrictive pericarditis can be separated reliably from those with restrictive cardiomyopathy based on a higher systolic/diastolic ratio and greater respiratory variation of their PV diastolic flow velocity. There were no complications in any patient due to volume expansion. Although the change from baseline to volume expansion was not statistically significant in either constriction or restriction, the %E of the PV diastolic wave became significantly higher in constriction than in restriction (P < 0.05). CONCLUSIONS: Rapid volume expansion is relatively safe during TEE and can be used for further separation of constrictive pericarditis from restrictive cardiomyopathy by significantly enhancing the respiratory variation of the PV diastolic flow velocity in constrictive pericarditis.

Adult↗

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography.

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Aged↗

Quantification of regional left ventricular wall motion in newborns by color kinesis.

BACKGROUND: Normal values for regional left ventricular wall motion, although documented in adults, have not been reported in healthy newborns. METHODS: This study prospectively evaluated global and segmental systolic and diastolic cardiac function by color kinesis in clinically asymptomatic healthy newborns. RESULTS: Eighty-eight asymptomatic infants who were less than 48 hours old were studied. Systolic and diastolic parameters of global and regional left ventricular function are reported as means +/- SD, medians, 5th and 95th percentiles to establish the normative values for newborns. The reported fractional area changes during systole and diastole are similar to the reported normal values for older subjects. Higher body surface area significantly correlated with an increased peak velocity during systole, and fractional area changes during filling of the lateral wall. CONCLUSIONS: Our report of left ventricular regional wall-motion characteristics of healthy newborns, as evaluated by color kinesis, may help in the objective evaluation and management of newborns suspected to have global or segmental ventricular dysfunction.

Body Surface Area↗

Diastolic filling abnormalities by color kinesis in newborns exposed to intrauterine cocaine.

Because cocaine crosses the placenta, we prospectively evaluated global and segmental systolic and diastolic cardiac function by color kinesis in clinically asymptomatic newborns who were exposed to cocaine in utero (group 1, n = 82). Their data were compared with normal controls (group 3, n = 87) and newborns exposed to drugs other than cocaine (group 2, n = 108). During left ventricular filling, newborns exposed to cocaine, compared with groups 2 and 3, had significantly (P <.05) higher global fractional area change (%) (76 +/- 10.3 vs 72 +/- 9.4 and 72 +/- 9.1, respectively), regional fractional area changes (%) for the anterior, septal, inferior, and lateral wall, and in the index of asynchrony (at 50% filling 13.2 +/- 5.8 vs 11.3 +/- 4.1 and 11.6 +/- 4.2, respectively). There were no significant differences in systolic function among the 3 groups. Prenatal cocaine exposure in asymptomatic infants leads to higher global and segmental fractional area changes and asynchrony during diastole. The significance and course of these alterations require further investigation.

Cocaine↗

Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study.

BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

Adult↗

Digital echocardiography 2002: now is the time.

The ability to acquire echocardiographic images digitally, store and transfer these data using the DICOM standard, and routinely analyze examinations exists today and allows the implementation of a digital echocardiography laboratory. The purpose of this review article is to outline the critical components of a digital echocardiography laboratory, discuss general strategies for implementation, and put forth some of the pitfalls that we have encountered in our own implementation. The major components of the digital laboratory include (1) digital echocardiography machines with network output, (2) a switched high-speed network, (3) a high throughput server with abundant local storage, (4) a reliable low-cost archive, (5) software to manage information, and (6) support mechanisms for software and hardware. Implementation strategies can vary from a complete vendor solution providing all components (hardware, software, support), to a strategy similar to our own where standard computer and networking hardware are used with specialized software for management of image and measurement information.

Echocardiography↗

Pulmonary venous flow determinants of left atrial pressure under different loading conditions in a chronic animal model with mitral regurgitation.

BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.

Animals↗

Prevalence of left ventricular diastolic dysfunction by Doppler echocardiography: clinical application of the Canadian consensus guidelines.

We evaluated diastolic filling patterns using Doppler echocardiography in 520 consecutive patients referred to our laboratory for transthoracic echocardiograms retrospectively and applied the standard guidelines used to characterize left ventricular (LV) diastolic function. Patients were classified by the Canadian consensus guidelines using transmitral and pulmonary venous Doppler echocardiographic parameters to have normal diastolic function or mild (abnormal relaxation), mild-to-moderate, moderate (pseudonormal), or severe (restrictive) diastolic dysfunction. LV diastolic dysfunction was present in 290 (56%) patients, whereas 167 (45%) patients with a normal LV ejection fraction had abnormal diastolic function. Patients with progressively more abnormal diastolic patterns had greater structural abnormalities with larger left atrial and LV size and lower LV ejection fractions. In the subset of patients with clinical evidence of congestive heart failure (99 patients), the prevalence of primary diastolic heart failure was 38% and most patients had underlying coronary or hypertensive heart disease. Standard guidelines of Doppler echocardiographic parameters allow semiquantitation of diastolic function and can be applied to studying large number of patients in a large clinical practice.

Adult↗

Diastolic alterations in infants exposed to intrauterine cocaine: a follow-up study by color kinesis.

BACKGROUND: During the first 48 hours of life, newborn infants exposed to cocaine in utero have left ventricular diastolic segmental abnormalities. It is unknown whether these abnormalities are transient because of short-term effects or persist in older infants, possibly reflecting a teratogenic effect of cocaine. METHODS: This study prospectively evaluated global and segmental systolic and diastolic cardiac parameters by color kinesis. The patients were 2- to 6-month-old infants who were exposed to cocaine in utero (N = 56). Their data were compared with normal control patients with no intrauterine drug exposure (N = 60) and newborns exposed to drugs other than cocaine (N = 72). RESULTS: At the age of 2 to 6 months, there was no significant difference in the measured color kinesis parameters among the cocaine-exposed and the 2 control groups (infants prenatally exposed to other drugs and no drugs). Infants exposed to heavy cocaine prenatally, as compared with the noncocaine-exposed group, had a significant (P =.007) increase in septal fractional area change during left ventricular filling. CONCLUSIONS: At 2 to 6 months of age, infants have recovered from initial left ventricular diastolic segmental alterations seen in the first 48 hours of life except for the septal wall in the heavily cocaine-exposed group.

Cocaine↗

Induction and maintenance of an experimental model of severe cardiomyopathy with a novel protocol of rapid ventricular pacing.

OBJECTIVE: An animal model of chronic severe heart failure is needed to evaluate new mechanical devices, surgical procedures, and medical therapies. The purpose of this study was to evaluate a unique new model of severe heart failure developed by means of a novel protocol of rapid ventricular pacing. METHODS: Heart failure was induced in 8 mongrel dogs by means of rapid ventricular pacing (230 beats/min) for 4 weeks. After a sham operation, maintenance pacing at a reduced rate (190 beats/min) was continued for another 4 weeks. RESULTS: Left ventricular systolic function was significantly reduced at week 4 and remained low at week 8, including the slope of the end-systolic pressure-volume relationship (2.4 +/- 1.0 vs 0.7 +/- 0.2 vs 0.8 +/- 0.3 mm Hg/mL [baseline vs week 4 vs week 8, respectively]), ejection fraction (63% +/- 5% vs 28% +/- 7% vs 33% +/- 5%), and cardiac output (3.1 +/- 0.7 vs 2.0 +/- 0.3 vs 2.2 +/- 0.7 L/min). Significant ventricular remodeling changes took place with increased ventricular volumes and circumferential wall stress, which were stable between weeks 4 and 8. Serum catecholamine and atrial natriuretic polypeptide levels also increased from baseline but stabilized between weeks 4 and 8. The end-diastolic pressure-volume relationship also showed stable diastolic function between weeks 4 and 8. CONCLUSIONS: Induction pacing at 230 beats/min readily created severe heart failure in all animals, and a new technique of maintenance pacing provided a consistent model of severe heart failure. This model can be used to study a variety of new interventions for heart failure.

Animals↗

Prediction of outcomes in hypertensive patients with suspected coronary disease.

Stress echocardiography has been shown to improve the diagnosis of coronary artery disease in the presence of hypertension, but its value in prognostic evaluation is unclear. We sought to determine whether stress echocardiography could be used to predict mortality in 2363 patients with hypertension, who were followed for up to 10 years (mean 4.0+/-1.8) for death and revascularization. Stress echocardiograms were normal in 1483 patients (63%), 16% had resting left ventricular (LV) dysfunction alone, and 21% had ischemia. Abnormalities were confined to one territory in 489 patients (21%) and to multiple territories in 365 patients (15%). Cardiac death was less frequent among the patients able to exercise than among those undergoing dobutamine echocardiography (4% versus 7%, P< 0.001). The risk of death in patients with a negative stress echocardiogram was <1% per year. Ischemia identified by stress echocardiography was an independent predictor of mortality in those able to exercise (hazard ratio 2.21, 95% confidence intervals 1.10 to 4.43, P=0.0001) as well as those undergoing dobutamine echo (hazard ratio 2.39, 95% confidence intervals 1.53 to 3.75, P=0.0001); other predictors were age, heart failure, resting LV dysfunction, and the Duke treadmill score. In stepwise models replicating the sequence of clinical evaluation, the results of stress echocardiography added prognostic power to models based on clinical and stress-testing variables. Thus, the results of stress echocardiography are an independent predictor of cardiac death in hypertensive patients with known or suspected coronary artery disease, incremental to clinical risks and exercise results.

Cohort Studies↗

Optimal mitral annular and subvalvular shape change created by the Coapsys device to treat functional mitral regurgitation.

We have reported that the Myocor Coapsys (Myocor, Inc, Maple Grove, MN) device treated functional mitral regurgitation (MR) by reducing mitral annular dimension and repositioning papillary muscles. This study was conducted to evaluate the optimal Coapsys device sizing level. The Coapsys device was implanted in seven dogs after induction of MR by rapid ventricular pacing. The device consists of anterior and posterior pads connected by a subvalvular cord. The device was tightened in 5% increments of the left ventricular epicardial to epicardial dimension up to 40%. Hemodynamic and echocardiographic measurements were repeated at each tightening level. The Coapsys significantly reduced or eliminated functional MR, and the reduction was maximized at the 30% tightening level or lower in all cases. Although the left ventricular end diastolic volume decreased significantly, forward stroke volume was maintained until the 35% tightening level. The forward ejection fraction significantly increased from 33 +/- 24% at baseline to 62 +/- 42% at 40% tightening level. Mean aortic pressure decreased slightly but significantly. The Coapsys device can be applied over a broad range of tightening levels with significant reduction in MR without negative physiologic impact. This feature makes the device usable [corrected] in a variety of clinical settings.

Animals↗