Search PubMed⌕ Search

Biomedical subjects

James Beach

Publications and source records attributed to James Beach.

2 recordsLinked to original sources

Automatic retinal oximetry.

PURPOSE: To measure hemoglobin oxygen saturation (SO(2)) in retinal vessels and to test the reproducibility and sensitivity of an automatic spectrophotometric oximeter. METHODS: Specialized software automatically identifies the retinal blood vessels on fundus images, which are obtained with four different wavelengths of light. The software calculates optical density ratios (ODRs) for each vessel. The reproducibility was evaluated by analyzing five repeated measurements of the same vessels. A linear relationship between SO(2) and ODR was assumed and a linear model derived. After calibration, reproducibility and sensitivity were calculated in terms of SO(2). Systemic hyperoxia (n = 16) was induced in healthy volunteers by changing the O(2) concentration in inhaled air from 21% to 100%. RESULTS: The automatic software enhanced reproducibility, and the mean SD for repeated measurements was 3.7% for arterioles and 5.3% venules, in terms of percentage of SO(2) (five repeats, 10 individuals). The model derived for calibration was SO(2) = 125 - 142 . ODR. The arterial SO(2) measured 96% +/- 9% (mean +/- SD) during normoxia and 101% +/- 8% during hyperoxia (n = 16). The difference between normoxia and hyperoxia was significant (P = 0.0027, paired t-test). Corresponding numbers for venules were 55% +/- 14% and 78% +/- 15% (P < 0.0001). SO(2) is displayed as a pseudocolor map drawn on fundus images. CONCLUSIONS: The retinal oximeter is reliable, easy to use, and sensitive to changes in SO(2) when concentration of O(2) in inhaled air is changed.

Humans↗

Disposable diaper to collect urine samples from young children for pyrethroid pesticide studies.

Disposable diapers are widely used in the US and many other areas in the world; therefore, they are ideal media for urine collection for measurement of young children's exposure to pesticides. However, disposable diapers normally contain polyacrylate polymers that make the extraction and analysis of urine very difficult. The objectives of this paper were to evaluate whether disposable diapers that contain polyacrylate granules can be extracted using salt solutions, and whether they can be used for the collection and quantitative measurements of selected urinary pyrethroid pesticide metabolites and creatinine. The storage stability of the metabolites and creatinine in a wet diaper at body temperature and at refrigeration temperature was also evaluated. Salt solutions including calcium chloride dihydrate, magnesium sulfate, ammonium acetate, and sodium chloride solutions were tested for efficiency of polymer shrinkage. Pyrethroid metabolites 3-(2,2-dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid (DCCA), 3-(2,2-dibromovinyl)-2,2,dimethyl-(1-cyclopropane) carboxylic acid (DBCA) and 3-phenoxybenzoic acid (3-PBA) were analyzed using LC/MS/MS and evaluated for recoveries in the urine released from the diapers. The study found calcium chloride dihydate to be satisfactory in releasing urine and metabolites from the polymers. The percent recoveries for the three tested pyrethroid metabolites were mostly in the range of 65-130. The percent recoveries for creatinine were in the range of 71-133. The detection limit for each of the three metabolites was 0.1 microg/l. The pyrethroid metabolites and creatinine were stable on the diaper for at least 72 h. We concluded from this study that calcium chloride dihydrate can successfully release urine and metabolites from polyacrylate-containing diapers, and the method is promising for studies of pyrethroid metabolites.

Body Temperature↗