Comparison of intraarterial MR angiography at 3.0 T with X-ray digital subtraction angiography for detection of renal artery stenosis in swine.

PURPOSE: To compare the accuracy of catheter-directed intraarterial (IA) magnetic resonance (MR) angiography at 3.0 T with that of x-ray digital subtraction angiography (DSA) for the measurement of renal artery stenosis (RAS) in swine. MATERIALS AND METHODS: Unilateral hemodynamically significant RAS (>50%) was induced surgically in six pigs with use of reverse cable ties. One to two weeks after surgery, each pig underwent x-ray DSA and MR angiography before and after percutaneous transluminal balloon angioplasty (PTA). X-ray DSA was performed before and after PTA of RAS by injection of iodinated contrast agent through a 5-F multiple-side hole angiographic catheter placed in the abdominal aorta under fluoroscopic guidance. MR angiography of RAS was performed before and after PTA of RAS on a 3.0-T clinical MR imager with use of gadolinium-based contrast agent. MR angiography and DSA images were analyzed with the full width at half maximum method. Percent stenosis measurements between x-ray DSA and MR angiography were compared with a paired t test and were correlated with linear regression and Bland Altman analysis (alpha = 0.05). RESULTS: Six cases of RAS were induced and imaged successfully with DSA and MR angiography techniques before and after PTA. On x-ray DSA, median stenoses was 64% (95% CI 57%-80%) before PTA and 20% (95% CI 5%-32%) after PTA. Corresponding MR angiography median stenosis measurement was 69% (95% CI 58%-80%) before PTA and 26% (95% CI 16%-36%) after PTA. A paired t test comparison did not show a difference between DSA and MR angiography (P = .16). RAS measurements on MR angiography correlated closely (P < .01) with DSA measurements (r(2) = 0.92). CONCLUSION: In swine, the accuracy of catheter-directed IA MR angiography with use of a clinical 3.0-T MR imaging unit for the measurement of RAS was similar to that of conventional x-ray DSA.

Angiography, Digital Subtraction↗

MR imaging- versus conventional X-ray fluoroscopy-guided renal angioplasty in swine: prospective randomized comparison.

PURPOSE: To test the hypothesis that the technical success rates, complication rates, and procedural times for magnetic resonance (MR) imaging-guided percutaneous transluminal angioplasty (PTA) and conventional (x-ray) fluoroscopy-guided PTA for treatment of renal artery stenosis are similar. MATERIALS AND METHODS: The study was animal care and use committee approved. After surgically inducing bilateral renal artery stenosis in 11 swine, the authors performed baseline digital subtraction angiography. They transferred each animal to a 1.5-T MR imaging unit and randomly decided which artery would be treated with MR-guided PTA. With MR imaging guidance, angioplastic devices were tracked by using active and passive techniques. Vascular depiction was achieved by using catheter-directed MR angiography. Stenotic vessels were dilated by using 5-6-mm-diameter balloon catheters. PTA was then performed in the contralateral artery by using conventional fluoroscopy-guided techniques. With the intention to treat, the authors compared the technical success (residual stenosis < 50%) rates, complication rates, and procedural times for each guidance method. They compared technical successes and complications by using the McNemar test and procedural times by using a paired t test, with P < .05 indicating a significant difference. RESULTS: The authors successfully dilated nine (82%) of 11 renal arteries with MR guidance and all 11 arteries (100%) with conventional fluoroscopic guidance. The difference was not significant (P = .5). Complications occurred in three (27%) arteries with MR guidance and in one (9%) artery with fluoroscopic guidance, with no significant differences (P = .5). The mean MR-guided PTA procedural time was 46 minutes longer than the fluoroscopy-guided PTA procedural time; this difference was significant (P = .01). CONCLUSION: In a small cohort of swine, the authors did not observe a significant difference between MR imaging- and conventional fluoroscopy-guided renal artery PTA in terms of success and complication rates. However, no evidence of similarity between the techniques should be assumed. Procedural times differed significantly.

Angioplasty↗

Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine.

The accuracy of a two-step interventional MRI protocol to quantify coronary artery disease was compared to the clinical gold standard, X-ray angiography. Studies were conducted in nine swine with a surgically induced stenosis in the proximal left circumflex coronary artery. The two-step protocol consisted of catheter-directed magnetic resonance angiography (MRA), which was first used to localize the stenosis, followed by MRI cross-sectional images to quantify the degree of stenosis without the use of contrast agent. Line signal intensity profiles were drawn across the vessel diameter at the stenosis site and proximal to the stenosis for each data set to measure percentage stenosis for each animal. Catheter-directed MRA successfully detected eight of nine stenoses. Cross-sectional MRI accurately quantified each stenosis, with strong agreement to the measurements made using X-ray fluoroscopy (intraclass correlation coefficient = 0.955; P < 0.05). This study demonstrates that in the future interventional MRI may be an alternative to X-ray angiography for the detection and quantification of coronary artery disease.

Angiography↗

Validating DICOM content in a remote storage model.

Verifying the integrity of DICOM files transmitted between separate archives (eg, storage service providers, network attached storage, or storage area networks) is of critical importance. The software application described in this article retrieves a specified number of DICOM studies from two different DICOM storage applications; the primary picture archiving and communication system (PACS) and an off-site long-term archive. The system includes a query/retrieve (Q/R) module, storage service class provider (SCP), a DICOM comparison module, and a graphical user interface. The system checks the two studies for DICOM 3.0 compliance and then verifies that the DICOM data elements and pixel data are identical. Discrepancies in the two data sets are recorded with the data elements (tag number, value representation, value length, and value field) and pixel data (pixel value and pixel location) in question. The system can be operated automatically, in batch mode, and manually to meet a wide variety of use cases. We ran this program on a 15% statistical sample of 50,000 studies (7500 studies examined). We found 2 pixel data mismatches (resolved on retransmission) and 831 header element mismatches. We subsequently ran the program against a smaller batch of 1000 studies, identifying no pixel data mismatches and 958 header element mismatches. Although we did not find significant issues in our limited study, given other incidents that we have experienced when moving images between systems, we conclude that it is vital to maintain an ongoing, automatic, systematic validation of DICOM transfers so as to be proactive in preventing possibly catastrophic data loss.

Computer Communication Networks↗

Informatics in radiology (infoRAD): integrating MIRC-compliant semiautomated teaching files into PACS work flow.

A Medical Image Resource Center (MIRC)-compliant teaching file system was created that can be integrated into a picture archiving and communication system (PACS) environment. This system models the three-step process necessary for efficient teaching file creation in a PACS environment: (a) identifying and transferring a case quickly and easily during primary interpretation, (b) editing and authoring the case outside of primary interpretation time, and (c) publishing the case locally and via MIRC standard-based mechanisms. Images from interesting cases are e-mailed to the teaching file system from either the PACS workstation or the radiologist's personal computer. Notes and clinical information may be included in the e-mail text to prompt the recollection of case details. Images are automatically extracted from the e-mail and sent to an image repository, and text fields are captured in a database. The World Wide Web-based authoring component provides tools for final authoring of cases and for the manipulation of existing cases. Authors designate access levels for each case, which is then made available locally and, potentially, to the entire MIRC-compliant community. Although this application has not yet been implemented as a departmental solution, it promises to improve and streamline medical education and promote better patient care.