Angle-supported anterior chamber phakic intraocular lens explantation causes and outcome.

PURPOSE: To investigate the reasons for explantation of angle-supported phakic intraocular lenses (IOLs) as well as the outcome and safety of the explantation procedure. DESIGN: Consecutive retrospective series. PARTICIPANTS: One hundred eyes of 66 patients who underwent phakic angle-supported IOL explantation. INTERVENTION: Surgical explantation of anterior chamber angle-supported phakic IOLs. MAIN OUTCOME MEASURES: Visual acuity, refraction, and endothelial cell density. RESULTS: The main causes of explantation were cataract development (64 cases [64%]), progressive endothelial cell loss (24 cases [24%]), and pupil ovalization (10 cases [10%]). According to the reason for phakic IOL explantation and the condition of the eye at time of explantation, 92 cases underwent bilensectomy (phakic IOL explantation followed by phacoemulsification of the crystalline lens), 2 cases underwent phakic IOL exchange, 4 cases underwent concomitant phakic IOL explantation and penetrating keratoplasty, and 2 cases underwent simple explantation of a phakic IOL. The mean time between phakic anterior chamber IOL implantation and explantation due to cataract was 10.04+/-3.66 years (range, 2-14). The mean time between implantation and secondary intervention due to progressive endothelial cell loss was 8.97+/-2.21 years (range, 2-14), and most of these cases were related to a specific model of angle-supported phakic IOL. CONCLUSION: Nuclear cataract was the most frequent reason for angle-supported phakic IOL explantation. Bilensectomy was effective and maintained the refractive benefits obtained with phakic IOL implantation. Few cases developed severe endothelial cell loss, most of them related to certain types of phakic IOLs.

Adult↗

Transient light-sensitivity syndrome after laser in situ keratomileusis with the femtosecond laser Incidence and prevention.

PURPOSE: To describe the incidence of transient light-sensitivity syndrome (TLSS) after laser in situ keratomileusis (LASIK) with the femtosecond laser and to identify preventive strategies. SETTING: Hospital NISA Virgen del Consuelo, Valencia, Spain. METHODS: The first 765 eyes operated on with the 15 KHz femtosecond laser were prospectively analyzed for subjective complaints and clinical findings compatible with TLSS. Intraoperative settings, postoperative treatment, and development of complications were analyzed. RESULTS: Overall, TLSS developed in 10 eyes (incidence 1.3%). However, the incidence decreased from 2.8% to 0.4% when aggressive topical steroids were used during the first 3 postoperative days. Postoperative interface inflammation and postoperative use of a low-dose topical steroid regimen were associated with a higher incidence of TLSS. CONCLUSIONS: Transient light-sensitivity syndrome is a relatively uncommon complication related to the use of the femtosecond laser. Postoperative interface inflammation may increase the probability of developing TLSS, whereas an aggressive postoperative steroid regimen seemed to provide protection against it.

Adult↗

Prophylactic perioperative antiviral therapy for LASIK in patients with inactive herpetic keratitis.

PURPOSE: To report the outcome of LASIK in patients with inactive herpetic keratitis in which perioperative antiviral prophylaxis was used to prevent the recurrence of ocular herpes. METHODS: We report an uncontrolled series of five patients with inactive herpetic keratitis for at least 1 year before surgery in whom LASIK was successfully performed. All patients showed normal topography, pachymetry, and corneal sensitivity with no central corneal scarring. Perioperative prophylaxis was used in each case with oral valacyclovir and topical acyclovir ointment. RESULTS: None of the eyes developed reactivation of herpetic keratitis during follow-up. CONCLUSIONS: This study suggests that perioperative antiviral prophylaxis may protect the cornea from herpes simplex virus reactivation after LASIK.

Acyclovir↗

LASIK in patients with rheumatic diseases: a pilot study.

PURPOSE: To investigate the safety of LASIK in patients with a known history of controlled rheumatic diseases. DESIGN: Retrospective consecutive observational clinical study. PARTICIPANTS: Forty-two eyes (22 patients) known to have had a history of rheumatic diseases underwent LASIK. All patients had a history of controlled rheumatic diseases, including rheumatoid arthritis, systemic lupus erythematosus, dermatomyositis, scleroderma, ankylosing spondylitis, psoriatic arthritis, inflammatory bowel disease, arthritis, or Behçet's disease. METHODS: Assessments were made preoperatively and at 1, 3, and 6 months postoperatively and included visual acuity (VA), refraction, keratometric readings, slit-lamp biomicroscopy, and corneal topography. All the patients underwent LASIK. Postoperative treatment included a topical steroid-antibiotic combination. MAIN OUTCOME MEASURES: Visual acuity, refraction, keratometric readings, and slit-lamp biomicroscopy findings at 1, 3, and 6 months postoperatively. RESULTS: LASIK was performed uneventfully on all patients. The mean pre-LASIK spherical equivalent (SE) was -5.39+/-2.25, and the sixth month postoperative SE was -0.15+/-0.38 diopters (D) (P<0.001). Uncorrected VA 6 months after the LASIK procedure was 20/25. Enhancement procedures were performed in 6 of 42 eyes (14.3%) at variable times after the primary procedure. Postoperative follow-up showed development of a moderate degree of dry eye syndrome in 4 eyes (9.5%). Corneal haze, melting, flap, or interface complications were not observed in any of the study eyes. CONCLUSIONS: In this small series, we found good outcomes when correcting refractive errors using LASIK in selected patients with controlled rheumatic diseases. In this series, a favorable postoperative visual outcome was obtained with no operative or postoperative vision-threatening complications.

Adult↗

Severe anaphylactic reaction after intracameral antibiotic administration during cataract surgery.

We report a severe anaphylactic reaction that occurred about 5 minutes after 1.0 mg of cefuroxime was injected into the anterior chamber after routine phacoemulsification and intraocular lens implantation. The patient was known to be allergic to penicillin. Immediate action was taken, and the patient recovered well. The presence of staff trained in resuscitation was essential in this case and raises questions about the trend to perform routine topical anesthesia cataract surgery without an anesthesiologist in the operating room.

Aged↗

Intracorneal inlay complicated by intrastromal epithelial opacification.

OBJECTIVE: To report epithelial perilenticular opacity as a new complication of intracorneal inlay implantation for the correction of hyperopia. DESIGN: Prospective observational case series. PARTICIPANTS: Eleven eyes of 7 patients underwent intracorneal inlay implantation for the correction of hyperopia. METHODS: Intracorneal inlays were implanted onto the stromal bed by using a microkeratome cut to create an inferior hinged corneal flap. MAIN OUTCOME MEASURES: Postoperative complication occurrence of intracorneal perilenticular opacity, microbiological laboratory analysis, histopathological analysis, and confocal microscopy study. RESULTS: Of 11 implanted eyes, 5 showed diffuse perilenticular opacity of varying intensity that was unresponsive to steroid use following intracorneal inlay implantation. All patients had moderate to severe loss of best-corrected visual acuity. The inlays showed deposits at the edge and on the surface. Confocal microscopy in all eyes produced images compatible with the confocal morphologic features of epithelial cells. Explantation of inlays was performed in 5 eyes. The histopathologic study showed the presence of epithelial cells, and microbiological analysis and cultures were negative for bacteria, fungi, and mycobacteria. CONCLUSION: Epithelial perilenticular opacity is a new and serious complication in patients with intracorneal inlay implantation for the correction of hyperopia.

Adult↗

Laser in situ keratomileusis to correct post-keratoplasty astigmatism; 1-step versus 2-step procedure.

PURPOSE: To investigate the correction of post-penetrating keratoplasty (PKP) astigmatism using laser in situ keratomileusis (LASIK). Visual and refractive outcomes were evaluated after LASIK was performed in 1 step (lamellar cut and ablation in 1 procedure) or 2 steps (lamellar cut then ablation in 2 successive procedures). SETTING: Department of Cornea and Refractive Surgery, Vissum-Instituto Oftalmológico de Alicante, University of Miguel Hernández, Alicante, Spain. METHODS: In this prospective observational study, 22 consecutive eyes were divided into 2 groups depending on the LASIK procedure performed to correct post-PKP astigmatism. Group 1 (1-step LASIK) included 11 eyes and Group 2 (2-step LASIK), 11 eyes. The patients were followed for 6 months. RESULTS: A statistically significant improvement was obtained in Group 2 with a mean vector analysis result of the cylinder of -4.37 diopters (D) +/- 1.79 (SD) (P = .018). In Group 1, the mean astigmatism correction was 2.38 +/- 1.71 D. The number of reoperations and residual refractive defects were significantly better in Group 2. CONCLUSION: The 2-step technique improved the accuracy of excimer laser correction of post-PKP astigmatism.

Adolescent↗

Comparison of four corneal pachymetry technique;s in corneal refractive surgery.

PURPOSE: To assess the effectiveness of optical and ultrasonic pachymetry when examining corneas of patients before and after laser in situ keratomileusis (LASIK). METHODS: We conducted a prospective study of 25 patients (50 eyes) who had LASIK for myopia or myopic astigmatism (mean spherical equivalent refraction -4.80 +/- 3.60 D; range -1.75 to -12.00 D). Corneal thickness was measured using 1) conventional ultrasonic pachymetry (20 MHz probe) in the central cornea, 2) ASL confocal microscopy (CMTF analysis), 3) Orbscan II Analyzer, and 4) ultrasound biomicroscopy (UBM) (50 MHz probe) preoperatively and 3 months postoperatively. RESULTS: Preoperative pachymetry values measured with the Orbscan II Analyzer (551.3 +/- 27.3 microm) were almost identical to those measured with the 20 MHz ultrasonic probe (553.7 +/- 25.7 microm; t-test P = .652). The mean preoperative pachymetry for UBM was 566.7 +/- 38.8 microm and for CMTF was 553.2 +/- 15.5 microm. The optic and ultrasonic system measurements differed in operated eyes; 20 MHz ultrasonic pachymetry yielded an average 478.7 +/- 23.5 microm and the UBM, 482.4 +/- 40.3 microm. These measurements differed from the Orbscan II (Tukey test; P = .023) measurement of 461.1 +/- 37.5 microm but not from the confocal microscopy measurement of 475.2 +/- 41.8 microm. UBM registered greater values that were more variable than those obtained with ultrasonic pachymetry. CONCLUSIONS: In non-operated eyes, corneal thickness was similar using conventional ultrasound, Orbscan II, or confocal techniques, with ultrasound biomicroscopy giving thicker readings.

Adult↗

Confocal microscopy of disposable and nondisposable heads for the Moria M2 microkeratome.

PURPOSE: To study the quality of the flap obtained with two different heads, disposable and nondisposable, and two different speeds, low and high, using the same Moria M2 microkeratome (Moria, Antony, France). METHODS: In a prospective randomized study, 51 consecutive eyes (28 patients) underwent myopic LASIK (-4.39 +/- 2.15 diopters). The eyes were randomly assigned to four groups related to cutting head model (disposable and nondisposable) and cut speed (low and high). In all cases, the intended cut was 160 microm and the same M2 unit was used. During surgery, superficial measurements of the flap and the surgeon's opinion about the quality of the cut were recorded. One month after LASIK, the cut depth, interface particle density, and transparency of the cornea (confocal wound healing opacity index) were measured with a confocal microscope. RESULTS: Flaps performed with a disposable cutting head and high speed were statistically significantly larger than the flaps created in the other groups (Kruskal-Wallis test; P = .041). No statistical differences were noted in cut depth, number of particles, and wound healing opacity index. The surgeon's opinion parameters were similar in all groups. CONCLUSIONS: The Moria M2 microkeratome is safe and provided reproducible results, regardless of cutting head and speed. Disposable and nondisposable head models were similar in their outcome in the quality control model used in this study.

Cornea↗