Search PubMed⌕ Search

Biomedical subjects

Jaap Stoker

Publications and source records attributed to Jaap Stoker.

At least 19 recordsLinked to original sources

European Society of Gastrointestinal and Abdominal Radiology (ESGAR): consensus statement on CT colonography.

Rapid clinical dissemination of CT colonography (CTC) is occurring in parallel with continued research into technique optimisation and diagnostic performance. A need exists therefore for current guidance as to basic prerequisites for effective clinical implementation. A questionnaire detailing CTC technique, analysis, training and clinical implementation was developed by the European Society of Gastrointestinal and Abdominal Radiology (ESGAR) CTC committee and circulated to all faculty members of previous ESGAR "hands-on" CTC training courses. Responses were collated and a consensus statement produced. Of 27 invited to participate, 24 responded. Reasonable consensus was reached on bowel preparation, colonic distension, patient positioning, use of IV contrast and optimal scan parameters. Both primary 2D and primary 3D analysis were advocated equally, with some evidence that more experienced readers prefer primary 2D. Training was universally recommended, although there was no consensus regarding minimum requirements. CTC was thought superior to barium enema, although recommended for screening only in the presence of validated local experience. There was consensus that polyps 4 mm or less could be ignored assuming agreement from local gastroenterological colleagues. There is increasing consensus amongst European experts as to the current best practice in CTC.

Advisory Committees↗

A comparison of primary two- and three-dimensional methods to review CT colonography.

The aim of our study was to compare primary three-dimensional (3D) and primary two-dimensional (2D) review methods for CT colonography with regard to polyp detection and perceptive errors. CT colonography studies of 77 patients were read twice by three reviewers, first with a primary 3D method and then with a primary 2D method. Mean numbers of true and false positives, patient sensitivity and specificity and perceptive errors were calculated with colonoscopy as a reference standard. A perceptive error was made if a polyp was not detected by all reviewers. Mean sensitivity for large (> or = 10 mm) polyps for primary 3D and 2D review was 81% (14.7/18) and 70%(12.7/18), respectively (p-values > or = 0.25). Mean numbers of large false positives for primary 3D and 2D were 8.3 and 5.3, respectively. With primary 3D and 2D review 1 and 6 perceptive errors, respectively, were made in 18 large polyps (p = 0.06). For medium-sized (6-9 mm) polyps these values were for primary 3D and 2D, respectively: mean sensitivity: 67%(11.3/17) and 61%(10.3/17; p-values > or = 0.45), number of false positives: 33.3 and 15.6, and perceptive errors : 4 and 6 (p = 0.53). No significant differences were found in the detection of large and medium-sized polyps between primary 3D and 2D review.

Adult↗

Clinical presentation of fecal incontinence and anorectal function: what is the relationship?

OBJECTIVES: Fecal incontinence is classified into various types: passive, urge, and combined. Its clinical presentation is thought to be related to the underlying physiological or anatomical abnormality. The aim of the present study was to evaluate the associations between the frequency of clinical symptoms and anatomic and functional characteristics of the anorectum of patients with severe fecal incontinence. METHODS: Associations were explored in a consecutive series of 162 patients (91% women, mean age 59 [SD +/- 12] yr) with a mean Vaizey incontinence score of 18 (SD +/- 3). RESULTS: Urge incontinence was reported as "daily" by 55%, "often" by 27%, and "sometimes" by 7% of all patients. No significant associations were observed between the frequency of urge incontinence and either manometric data, anal mucosal sensitivity testing, or defects of internal anal sphincter (IAS) or external anal sphincter (EAS). A significant relation was observed between the frequency of urge incontinence and maximal tolerable volume (P= 0.03) and atrophy of the EAS (P= 0.05). Passive incontinence was reported as "daily" by 14%, "often" by 30%, and "sometimes" by 14% of all patients. Resting and maximal squeeze pressure were both associated (P < 0.001) with the frequency of passive incontinence. No relationship could be detected between clinical presentation and rectal sensation, anal mucosal sensitivity, defects, or atrophy of IAS or EAS. CONCLUSION: Most patients reported combined incontinence (59%) and underlying pathophysiologic abnormalities were identified. The hypothesized associations between urge and passive incontinence and functional and anatomical impairment of the anorectum are less clear-cut than previously assumed. Patients presenting with fecal incontinence should undergo physiologic investigation.

Aged↗

Anal inspection and digital rectal examination compared to anorectal physiology tests and endoanal ultrasonography in evaluating fecal incontinence.

BACKGROUND: Anal inspection and digital rectal examination are routinely performed in fecal incontinent patients but it is not clear to what extent they contribute to the diagnostic work-up. We examined if and how findings of anal inspection and rectal examination are associated with anorectal function tests and endoanal ultrasonography. METHODS: A cohort of fecal incontinent patients (n=312, 90% females; mean age 59) prospectively underwent anal inspection and rectal examination. Findings were compared with results of anorectal function tests and endoanal ultrasonography. RESULTS: Absent, decreased and normal resting and squeeze pressures at rectal examination correlated to some extent with mean (+/-SD) manometric findings: mean resting pressure 41.3 (+/-20), 43.8 (+/-20) and 61.6 (+/-23) Hg (p<0.001); incremental squeeze pressure 20.6 (+/-20), 38.4 (+/-31) and 62.4 (+/-34) Hg (p<0.001). External anal sphincter defects at rectal examination were confirmed with endoanal ultrasonography for defects <90 degrees in 36% (37/103); for defects between 90-150 degrees in 61% (20/33); for defects between 150-270 degrees in 100% (6/6). Patients with anal scar tissue at anal inspection had lower incremental squeeze pressures (p=0.04); patients with a gaping anus had lower resting pressures (p=0.013) at anorectal manometry. All other findings were not related to any anorectal function test or endoanal ultrasonography. CONCLUSIONS: Anal inspection and digital rectal examination can give accurate information about internal and external anal sphincter function but are inaccurate for determining external anal sphincter defects <90 degrees. Therefore, a sufficient diagnostic work-up should comprise at least rectal examination, anal inspection and endoanal ultrasonography.

Anal Canal↗

Is there a role for magnetic resonance imaging in the evaluation of inguinal lymph node metastases in patients with vulva carcinoma?

OBJECTIVE: To study the accuracy of magnetic resonance imaging (MRI) in lymph node detection in patients with vulva carcinoma. METHODS: Sixty patients with diagnosed vulva carcinoma underwent MRI examination for preoperative evaluation of lymph nodes. MRI images were read independently and retrospectively by two radiologists, both unaware of physical examination and surgery findings. The following characteristics of each lymph node with a short-axis diameter of >or=8 mm were recorded: size (axial, sagittal and coronal); aspect (homogeneous, with fatty center or partial fat); margin (smooth, lobulated/speculated or indistinct); shape: (round, ovoid or elongated). Based on these characteristics, each lymph node was classified as malignant or benign and subsequently each groin was classified as malignant or benign. Histopathology obtained at sentinel node procedure or by inguinofemoral lymphadenectomy was used as reference standard. Per groin sensitivity, specificity, positive and negative predictive values were calculated. Kappa statistics on per groin basis were calculated to express interobserver agreement. RESULTS: One hundred nineteen groins were examined either by sentinel node procedure or surgery, of which 23 groins were malignant. Sensitivity, specificity, positive and negative predictive values were 52%, 85%, 46% and 87% for observer 1 and 52% 89%, 52% and 89% for observer 2. The interobserver agreement was 104/119 (kappa 0.62), representing good agreement. CONCLUSION: At this stage there is no role for standard MRI in evaluating lymph node involvement in patients with vulva carcinoma.

Adult↗

Chest radiography practice in critically ill patients: a postal survey in the Netherlands.

BACKGROUND: To ascertain current chest radiography practice in intensive care units (ICUs) in the Netherlands. METHODS: Postal survey: a questionnaire was sent to all ICUs with > 5 beds suitable for mechanical ventilation; pediatric ICUs were excluded. When an ICU performed daily-routine chest radiographs in any group of patients it was considered to be a "daily-routine chest radiography" ICU. RESULTS: From the number of ICUs responding, 63% practice a daily-routine strategy, in which chest radiographs are obtained on a daily basis without any specific reason. A daily-routine chest radiography strategy is practiced less frequently in university-affiliated ICUs (50%) as compared to other ICUs (68%), as well as in larger ICUs (> 20 beds, 50%) as compared to smaller ICUs (< 20 beds, 65%) (P > 0.05). Remarkably, physicians that practice a daily-routine strategy consider daily-routine radiographs helpful in guiding daily practice in less than 30% of all performed radiographs. Chest radiographs are considered essential for verification of the position of invasive devices (81%) and for diagnosing pneumothorax, pneumonia or acute respiratory distress syndrome (82%, 74% and 69%, respectively). On demand chest radiographs are obtained after introduction of thoracic drains, central venous lines and endotracheal tubes in 98%, 84% and 75% of responding ICUs, respectively. Chest films are also obtained in case of ventilatory deterioration (49% of responding ICUs), and after cardiopulmonary resuscitation (59%), tracheotomy (58%) and mini-tracheotomy (23%). CONCLUSION: There is notable lack of consensus on chest radiography practice in the Netherlands. This survey suggests that a large number of intensivists may doubt the value of daily-routine chest radiography, but still practice a daily-routine strategy.

Journal Article↗

Polyp measurement and size categorisation by CT colonography: effect of observer experience in a multi-centre setting.

The extent measurement error on CT colonography influences polyp categorisation according to established management guidelines is studied using twenty-eight observers of varying experience to classify polyps seen at CT colonography as either 'medium' (maximal diameter 6-9 mm) or 'large' (maximal diameter 10 mm or larger). Comparison was then made with the reference diameter obtained in each patient via colonoscopy. The Bland-Altman method was used to assess agreement between observer measurements and colonoscopy, and differences in measurement and categorisation was assessed using Kruskal-Wallis and Chi-squared test statistics respectively. Observer measurements on average underestimated the diameter of polyps when compared to the reference value, by approximately 2-3 mm, irrespective of observer experience. Ninety-five percent limits of agreement were relatively wide for all observer groups, and had sufficient span to encompass different size categories for polyps. There were 167 polyp observations and 135 (81%) were correctly categorised. Of the 32 observations that were miscategorised, 5 (16%) were overestimations and 27 (84%) were underestimations (i.e. large polyps misclassified as medium). Caution should be exercised for polyps whose colonographic diameter is below but close to the 1-cm boundary threshold in order to avoid potential miscategorisation of advanced adenomas.

Chi-Square Distribution↗

CT colonography interpretation times: effect of reader experience, fatigue, and scan findings in a multi-centre setting.

Our purpose was to assess the effect of reader experience, fatigue, and scan findings on interpretation time for CT colonography. Nine radiologists (experienced in CT colonography); nine radiologists and ten technicians (both groups trained using 50 validated examinations) read 40 cases (50% abnormal) under controlled conditions. Individual interpretation times for each case were recorded, and differences between groups determined. Multi-level linear regression was used to investigate effect of scan category (normal or abnormal) and observer fatigue on interpretation times. Experienced radiologists (mean time 10.9 min, SD 5.2) reported significantly faster than less experienced radiologists and technicians; odds ratios of reporting times 1.4 (CI 1.1, 1.8) and 1.6 (1.3, 2.0), respectively (P<or=0.001). Experienced and less-experienced radiologists took longer to report abnormal cases; ratio 1.2 (CI 1.1,1.4, P<0.001) and 1.2 (1.0, 1.3, P=0.03), respectively. All groups took 70% as long to report the final five cases as they did with an initial five; ratio 0.7 (CI 0.6 to 0.8), P<0.001. For technicians only, accuracy increased with longer reporting times (P=0.04). Experienced radiologists report faster than do less-experienced observers and proportionally spend less time interpreting normal cases. Technicians who report more slowly are more accurate. All groups reported faster as the study period progressed.

Clinical Competence↗

Effective radiation doses in CT colonography: results of an inventory among research institutions.

The purpose of this study was to estimate the effective dose that is currently used in CT colonography using scan parameters that were collected for this purpose, and to investigate trends in time. PubMed was systematically searched from 1996 until January 2004 for studies investigating CT colonography. Research institutions were contacted and asked for their current scan protocol. Thirty-six institutions published 74 studies. Twenty-eight of the 36 institutions provided their current protocol. The median effective dose in 2004 was 5.1 mSv (range 1.2-11.7 mSv) per position. Most institutions (93%) scan in both the supine and prone positions. The median mAs value was 67 mAs (range 20-200), median collimation was 2.5 mm (range 0.75-5). From 1996 until 2004 a significant decrease in mAs and collimation (P=0.006, P<0.0001, respectively) was observed, while institutions that used a multislice scanner increased (P<0.0001). The effective dose remained constant (P=0.76). In 2004 the median effective dose for a complete CT colonography was 10.2 mSv. Despite the increasing use of multislice scanners, which are slightly less dose-efficient, the median effective dose remained approximately constant between 1996 and 2004. This is mainly caused by the use of lower mAs settings.

Academies and Institutes↗

Feasibility of evaluating Crohn's disease activity at 3.0 Tesla.

PURPOSE: To determine whether abdominal 3.0T MRI can be used for evaluation of Crohn's disease (CD) compared with ileocolonoscopy (CS), and to determine patient preference for MRI as opposed to CS. MATERIALS AND METHODS: Twenty patients scheduled for CS underwent MRI. At CS, disease severity was graded and the Crohn's Disease Endoscopic Index of Severity (CDEIS) was determined. Radiological grading (by two observers) was compared with endoscopic grading and CDEIS. Patient experience and preference were determined. RESULTS: In respectively 10 (observer 1) and 13 patients (observer 2) exact agreement between radiological and endoscopic grading was found. In respectively 10 and 7 patients radiological and endoscopic grading differed one level. No statistically significant correlation was found between radiological grading and CDEIS. Between bowel wall thickness and CDEIS weak to moderate correlations were found, and between bowel wall enhancement and CDEIS weak correlations were found. All patients preferred MRI over CS. CONCLUSION: It is feasible to perform abdominal 3.0T MRI using orally administered contrast medium for evaluation of CD, and this method can be considered a patient-friendly alternative to CS.

Adult↗

Atrophy and defects detection of the external anal sphincter: comparison between three-dimensional anal endosonography and endoanal magnetic resonance imaging.

PURPOSE: Using endoanal magnetic resonance imaging, atrophy of the external anal sphincter can be established. This aspect has not been thoroughly investigated using three-dimensional anal endosonography. The purpose of this study was to compare prospectively three-dimensional anal endosonography to magnetic resonance imaging in the detection of atrophy and defects of the external anal sphincter in patients with fecal incontinence. In addition, we compared both techniques for anal sphincter thickness and length measurements. MATERIALS AND METHODS: Patients with fecal incontinence underwent three-dimensional anal endosonography and magnetic resonance imaging. Images of both endoluminal techniques were evaluated for atrophy and defects of the external anal sphincter. External anal sphincter atrophy scoring with three-dimensional anal endosonography depended on the distinction of the external anal sphincter and its reflectivity. External anal sphincter atrophy scoring with magnetic resonance imaging depended on the amount of muscle and the presence of fat replacement. Atrophy score was defined as none, moderate, and severe. A defect was defined at anal endosonography by a hypoechogenic zone and at magnetic resonance imaging as a discontinuity of the sphincteric ring and/or scar tissue. Differences between three-dimensional anal endosonography and magnetic resonance imaging for the detection of external anal sphincter atrophy and defects were calculated. In addition, we compared external anal sphincter thickness and length measurements in three-dimensional anal endosonography and magnetic resonance imaging. RESULTS: Eighteen patients were included (median age, 58 years; range, 27-80; 15 women). Three-dimensional anal endosonography and magnetic resonance imaging did not significantly differ for the detection of external anal sphincter atrophy (P = 0.25) and defects (P = 0.38). Three-dimensional anal endosonography demonstrated atrophy in 16 patients, magnetic resonance imaging detected atrophy in 13 patients. Three-dimensional anal endosonography agreed with magnetic resonance imaging in 15 of 18 patients for the detection of external anal sphincter atrophy. Using the grading system, 8 of the 18 patients scored the same grade. Three-dimensional anal endosonography detected seven external anal sphincter defects and magnetic resonance imaging detected ten. Three-dimensional anal endosonography and magnetic resonance imaging agreed on the detection of external anal sphincter defects in 13 of 18 patients. Comparison between three-dimensional anal endosonography and magnetic resonance imaging for sphincter thickness and length measurements showed no statistically significant concordance and had no correlation with external anal sphincter atrophy. CONCLUSION: This is the first study that shows that three-dimensional anal endosonography can be used for detecting external anal sphincter atrophy. Both endoanal techniques are comparable in detecting atrophy and defects of the external anal sphincter, although there is a substantial difference in grading of external anal sphincter atrophy. Correlation between three-dimensional anal endosonography and magnetic resonance imaging for thickness and length measurements is poor. Inconsistency between the two methods needs to be evaluated further.

Adult↗

Relationship between external anal sphincter atrophy at endoanal magnetic resonance imaging and clinical, functional, and anatomic characteristics in patients with fecal incontinence.

PURPOSE: External anal sphincter atrophy at endoanal magnetic resonance imaging has been associated with poor outcome of anal sphincter repair. We studied the relationship between external anal sphincter atrophy on endoanal magnetic resonance imaging and clinical, functional, and anatomic characteristics in patients with fecal incontinence. METHODS: In 200 patients (mean Vaizey score, 18 (+/-2.9 standard deviation)) magnetic resonance images were evaluated for external anal sphincter atrophy (none, mild, or severe) by radiologists blinded to anorectal functional test results and details from medical history. Subgroups of patients with and without atrophy were compared for medical history, anal manometry, pudendal nerve latency testing, anal sensitivity testing, external anal sphincter thickness, and external anal sphincter defects. Whenever significant differences were detected, we tested for differences between patients with mild and severe atrophy. RESULTS: External anal sphincter atrophy was demonstrated in 123 patients (62 percent): graded as mild in 79 (40 percent), and severe in 44 patients (22 percent). Patients with atrophy were more often female (P < 0.001) and older (P = 0.003). They had a lower maximal squeeze (P = 0.01) and squeeze increment pressure (P < 0.001). Patients with severe atrophy had a lower maximal squeeze (P = 0.003) and squeeze increment pressure (P < 0.001) than patients with mild atrophy. These effects were not attenuated by potential confounding variables. Patients with atrophy could not be identified a priori by other characteristics. CONCLUSIONS: External anal sphincter atrophy at endoanal magnetic resonance imaging was depicted in 62 percent of patients, varying from mild to severe. Because increasing levels of atrophy were associated with impaired squeeze function, further studies are needed to evaluate whether grading atrophy is clinically valuable in selecting patients for anal sphincter repair.

Age Factors↗

Computed tomography colonography: current issues.

OBJECTIVE: Direct and indirect evidence supports the concept of screening for adenomas and early stage colorectal cancer in reducing the incidence and disease-specific mortality. Controversy remains as to the appropriateness of and preferred methods for screening an asymptomatic population. METHODS: Review of computed tomography (CT) colonography based on the literature and personal experience. RESULTS AND CONCLUSIONS: Current discrepancies in the data on accuracy and patient acceptance of CT colonography reflect differences in the performance and evaluation of this examination. Before CT colonography can be implemented in colorectal cancer screening, factors that cause this variability must be elucidated. Studies in which high-resolution scanning, three-dimensional review methods and an enhanced colonoscopic reference are used achieve an accuracy that is similar to colonoscopy. At the same time the evidence that ultra-low radiation dose CT colonography is feasible is mounting, a development that dramatically reduces one of the largest obstacles for large-scale application of this technique.

Adenoma↗

Polyp miss rate determined by tandem colonoscopy: a systematic review.

BACKGROUND AND AIMS: Colonoscopy is the best available method to detect and remove colonic polyps and therefore serves as the gold standard for less invasive tests such as virtual colonoscopy. Although gastroenterologists agree that colonoscopy is not infallible, there is no clarity on the numbers and rates of missed polyps. The purpose of this systematic review was to obtain summary estimates of the polyp miss rate as determined by tandem colonoscopy. METHODS: An extensive search was performed within PUBMED, EMBASE, and the Cochrane Library databases to identify studies in which patients had undergone two same-day colonoscopies with polypectomy. Random effects models based on the binomial distribution were used to calculate pooled estimates of miss rates. RESULTS: Six studies with a total of 465 patients could be included. The pooled miss rate for polyps of any size was 22% (95% CI: 19-26%; 370/1,650 polyps). Adenoma miss rate by size was, respectively, 2.1% (95% CI: 0.3-7.3%; 2/96 adenomas > or =10 mm), 13% (95% CI: 8.0-18%; 16/124 adenomas 5-10 mm), and 26% (95% CI: 27-35%; 151/587 adenomas 1-5 mm). Three studies reported data on nonadenomatous polyps: zero of eight nonadenomatous polyps > or =10 mm were missed (0%; 95% CI: 0-36.9%) and 83 of 384 nonadenomatous polyps <10 mm were missed (22%; 95% CI: 18-26%). CONCLUSIONS: Colonoscopy rarely misses polyps > or =10 mm, but the miss rate increases significantly in smaller sized polyps. The available evidence is based on a small number of studies with heterogeneous study designs and inclusion criteria.

Colonic Polyps↗

Imaging of fistula in ano.

Fistula in ano is a common condition that often recurs despite seemingly adequate surgery, usually because of infection that was missed at surgery. It is now increasingly recognized that preoperative imaging can help identify infection that would have otherwise gone unidentified. In particular, magnetic resonance (MR) imaging findings have been shown to influence surgery and markedly diminish the chance of recurrence; thus, preoperative imaging will become increasingly routine in the future. In this article, the authors describe the pathogenesis, classification, and imaging of fistula in ano, with an emphasis on MR imaging. Most important, the authors describe how the radiologist is well placed to answer the surgical riddles that must be solved for treatment to be effective.

Humans↗

The clinical value of daily routine chest radiographs in a mixed medical-surgical intensive care unit is low.

INTRODUCTION: The clinical value of daily routine chest radiographs (CXRs) in critically ill patients is unknown. We conducted this study to evaluate how frequently unexpected predefined major abnormalities are identified with daily routine CXRs, and how often these findings lead to a change in care for intensive care unit (ICU) patients. METHOD: This was a prospective observational study conducted in a 28-bed, mixed medical-surgical ICU of a university hospital. RESULTS: Over a 5-month period, 2,457 daily routine CXRs were done in 754 consecutive ICU patients. The majority of these CXRs did not reveal any new predefined major finding. In only 5.8% of daily routine CXRs (14.3% of patients) was one or more new and unexpected abnormality encountered, including large atelectases (24 times in 20 patients), large infiltrates (23 in 22), severe pulmonary congestion (29 in 25), severe pleural effusion (13 in 13), pneumothorax/pneumomediastinum (14 in 13), and malposition of the orotracheal tube (32 in 26). Fewer than half of the CXRs with a new and unexpected finding were ultimately clinically relevant; in only 2.2% of all daily routine CXRs (6.4% of patients) did these radiologic abnormalities result in a change to therapy. Subgroup analysis revealed no differences between medical and surgical patients with regard to the incidence of new and unexpected findings on daily routine CXRs and the effect of new and unexpected CXR findings on daily care. CONCLUSION: In the ICU, daily routine CXRs seldom reveal unexpected, clinically relevant abnormalities, and they rarely prompt action. We propose that this diagnostic examination be abandoned in ICU patients.

APACHE↗

Dynamic contrast-enhanced MRI of the bowel wall for assessment of disease activity in Crohn's disease.

OBJECTIVE: The purpose of this study was to evaluate the role of contrast-enhanced dynamic MRI in predicting the disease activity of Crohn's disease. MATERIALS AND METHODS: Forty-eight patients in two hospitals who had clinically suspected exacerbation of Crohn's disease were included in this study. In three levels of thickened small-bowel wall, axial dynamic T1-weighted sequences were performed every 4-6 sec for a total duration of 2-3 min after contrast administration; static T1-weighted turbo spin-echo sequences were acquired both before and after contrast administration. The slope of enhancement, enhancement ratio, time to enhancement, enhancement time, and thickness of the small-bowel wall were determined. These MRI results were compared with overall clinical grade, Crohn's disease activity index (CDAI), and Van Hees activity index. Clinical grade was based on clinical information, physical findings, laboratory studies, endoscopy, surgery, and other imaging studies. Spearman's correlation coefficient and p values were determined per hospital. Fisher's z-transformation was applied before pooling the correlation coefficients from both hospitals. RESULTS: The enhancement ratio based on the static series showed significant correlation with the clinical grade (r = 0.29, p = 0.045), CDAI (r =0.31, p = 0.033), and Van Hees activity index (r = 0.36, p = 0.016). The enhancement ratio based on the dynamic series correlated significantly with the CDAI (r = 0.38, p = 0.016). Wall thickness correlated significantly with clinical grade (r = 0.47, p = 0.003) and Van Hees activity index (r = 0.41, p = 0.007). CONCLUSION: These data suggest that the enhancement ratio of bowel wall after IV administration of gadodiamide and bowel wall thickness are weak to moderate indicators of the severity of Crohn's disease.

Adolescent↗

MRI in evaluating atrophy of the external anal sphincter in patients with fecal incontinence.

OBJECTIVE: External anal sphincter atrophy seen at endoanal MRI may predict poor outcome of surgical anal sphincter repair for an external anal sphincter defect. The purposes of this study were to compare external phased-array MRI to endoanal MRI for depicting external anal sphincter atrophy in patients with fecal incontinence and to evaluate observer reproducibility in detecting external anal sphincter atrophy with these techniques. SUBJECTS AND METHODS: Thirty patients with fecal incontinence (23 women, seven men; mean age, 58.7 years; age range, 37-78 years) underwent both endoanal and external phased-array MRI. Images were evaluated for external anal sphincter atrophy by three radiologists. Measures of differences and agreement between both MRI techniques and of interobserver and intraobserver agreement of both techniques were calculated. RESULTS: The MRI techniques did not significantly differ in their ability to depict external anal sphincter atrophy (p = 0.63) with good agreement (kappa = 0.72). Interobserver agreement was moderate (kappa = 0.53-0.56) for endoanal MRI and moderate to good (kappa = 0.55-0.8) for external phased-array MRI. Intraobserver agreement was moderate to very good (kappa = 0.57-0.86) for endoanal MRI and fair to very good (kappa = 0.31-0.86) for external phased-array MRI. CONCLUSION: External phased-array MRI is comparable to endoanal MRI in depicting external anal sphincter atrophy and, thereby, in selecting patients for anal sphincter repair. Because results among interpreters varied considerably depending on the experience level, both techniques can be recommended in the diagnostic workup of fecal incontinence only if sufficient experience is available.

Adult↗