Search PubMed⌕ Search

Biomedical subjects

J vom Dahl

Publications and source records attributed to J vom Dahl.

At least 19 recordsLinked to original sources

Superiority of sirolimus eluting stent compared with intracoronary beta radiation for treatment of in-stent restenosis: a matched comparison.

OBJECTIVE: To compare acute and follow up clinical and angiographic results after treatment of in-stent restenosis (ISR) by sirolimus eluting stents (SES) with results obtained after intracoronary radiation therapy (IRT). DESIGN: Matched pair analysis. METHODS: 62 consecutive ISR lesions (< 30 mm lesion length, reference diameter < 3.5 mm) in 62 patients were treated with SES. From a database of 174 lesions (n = 141 patients) treated for ISR by intracoronary beta radiation, 62 lesions (62 patients) were pair matched with the SES group for diabetes mellitus, lesion length, vessel size, and pattern of ISR. Six month angiographic and 12 month clinical follow up results were obtained. RESULTS: Baseline clinical and angiographic characteristics were similar between the groups (not significant). SES implantation resulted in significantly lower postprocedural in-lesion diameter stenosis than did IRT (mean (SD) 14.2 (9.5)% v 21.1 (10.6)%, p = 0.001), significantly higher minimum lumen diameter at follow up (1.91 (0.58) v 1.55 (0.72) mm, p = 0.005), and a higher net gain (1.16 (0.55) v 0.77 (0.70) mm, p = 0.002). Angiographic binary in-lesion restenosis rate at six months was 11% in the SES group and 29% in the IRT group (p = 0.046). In 16 ISR lesions SES were used after failed IRT and in 46 lesions for first time ISR. In-lesion late loss was higher after use of SES for failed IRT than after use of SES for first time ISR (0.61 (0.67) mm v 0.24 (0.41) mm, p = 0.018). In a multivariate analysis prior failed IRT was the only independent predictor for recurrent restenosis after SES for ISR (p = 0.052, odds ratio 5.8). Six patients (10%) in the SES group and 17 patients (27%) in the IRT group underwent target lesion revascularisation during the 12 months of follow up (p = 0.022). CONCLUSIONS: In this non-randomised matched cohort SES achieved acute and follow up results superior to IRT for treatment of ISR even if cases of failed IRT are included. Failed IRT is a predictor of impaired SES effectiveness.

Beta Particles↗

Randomized comparison of success and adverse event rates and cost effectiveness of one long versus two short stents for treatment of long coronary narrowings.

Long stents of high flexibility and low profile have become widely available. Treatment of long coronary lesions by 1 long stent may require less interventional efforts and reduce the rate of restenosis due to a lack of overlapping stent segments. This study sought to evaluate the use of 1 long stent compared with 2 short stents for treatment of long coronary lesions. One-hundred twenty-four patients with a coronary lesion 20 to 40 mm in length, in a vessel 2.5 to 4.0 mm in diameter, were randomly assigned to treatment with 1 long stent (GFX II stents or S670 of 24, 30, or 40 mm lengths; n = 62) or 2 stents (GFX II or S670 stents, n = 62) of equal length. Procedural success, interventional costs, as well as long-term clinical and angiographic outcomes were evaluated. Lesion characteristics were similar for the 2 treatment groups. Stent placement was possible as assigned by randomization in 61 of 62 cases (98%) in the 1-long-stent group and 100% of cases in the 2-short-stents group. There was crossover to successful short-stent placement in 1 case. The in-hospital success rate was 97% for the 1-long-stent group and 98% for the 2-short-stents group. Acute angiographic results were similar for both groups after intervention. The angiographic restenosis rate at 6 months was 38.5% in the 1-long-stent group and 37.5% in the 2-short-stents group (p = 0.919). Intervention time was less, and the need for a contrast agent had a tendency to be lower in the long-stent group. Procedural costs were significantly less in the long-stent group. In conclusion, 1 long stent can be used with identical procedural success and adverse event rates as 2 short stents in long, atherosclerotic coronary lesions. The restenosis rate is not reduced by the use of 1 long stent compared with 2 stents. However, long stent placement is highly cost effective.

Aged↗

Three-year follow-up after rotational atherectomy for the treatment of diffuse in-stent restenosis: predictors of major adverse cardiac events.

Restenosis remains the major limitation of coronary stent implantation, especially in diffuse forms of in-stent restenosis. In this study, rotablation (RA) with adjunct angioplasty of in-stent restenosis was performed in 84 patients. Clinical follow-up and control angiography were obtained 6-month postprocedure. The rate of recurrent restenosis after rotablation for in-stent restenosis at 6-month angiographic follow-up was 45%, resulting in a rate of major adverse cardiac events of 35%. At 3-year follow-up, the cumulative event-free survival rate was 57% for the entire population. The only predictor of MACE at 3-year clinical follow-up by multivariate logistic regression analysis was in-stent lesion length. RA for the treatment of diffuse in-stent restenosis is thereby characterized by high procedural success rates and recurrent angiographic restenosis in 45% of patients with diffuse lesions. Major adverse cardiac events occur most likely within the first 6 months postprocedure. Three years after rotablation of in-stent restenosis, 43% of patients had experienced at least one major adverse cardiac event. Cathet Cardiovasc Intervent 2001;53:334-340.

Aged↗

Electromechanical assessment of left ventricular function following successful percutaneous coronary revascularization.

Percutaneous electromechanical mapping was applied to evaluate the impact of coronary revascularization on electrical and mechanical parameters in patients with prior myocardial infarction. In 15 patients with prior (> or = 4 weeks) myocardial Q-wave infarction and regional wall motion abnormalities, left ventricular endocardial mapping was performed immediately prior to percutaneous coronary revascularization. Patients underwent repetitive mapping during 6-month follow-up angiography with good revascularization results in all patients. Mean regional unipolar electrogram (UP) amplitude of all regions remained unchanged (10.4 +/- 4.2 mV prerevascularization vs. 10.2 +/- 4.4 mV postrevascularization), whereas mean local shortening (LS) of all regions increased from 6.0% +/- 5.8% to 9.7% +/- 5.3% (P < 0.001). The percentage of electromechanical match regions (LS < 6% and UP < 9 mV) remained unchanged after revascularization (15% vs. 10%; NS), whereas the percentage of mismatch regions (LS < 6% and UP > 9 mV) declined from 38% to 10% (P < 0.0001). We conclude that electromechanical mapping allows the sensitive detection of improved mechanical function after successful revascularization. Electrical activity remains unchanged 6 months after revascularization and the number of regions with an electromechanical mismatch decrease.

Aged↗

[Assessing myocardial perfusion with positron emission tomography].

Positron emission tomography (PET) of the heart has gained widespread scientific and clinical acceptance with regard to two indications: 1) The detection of perfusion abnormalities by qualitative and semiquantitative analyses of perfusion images at rest and during physical or pharmacological stress using well-validated perfusion tracers, such as N-13 ammonia, Rb-82 rubidium chloride, or O-15 labeled water. 2) Viability imaging of myocardial regions with reduced contractility by combining perfusion measurements with substrate metabolism as assessed from F-18 deoxyglucose utilization. This overview summarizes the use of PET as a perfusion imaging method. With a sensitivity > 90% in combination with high specificity, PET is today the best-validated available nuclear imaging technique for the diagnosis of coronary artery disease (CAD). The short half-life of the perfusion tracers in combination with highly sophisticated hard- and software enables rapid PET studies with high patient throughput. The high diagnostic accuracy and the methological advantages as compared to conventional scintigraphy allows one to use PET perfusion imaging to detect subtle changes in the perfusion reserve for the detection of CAD in high risk but asymptomatic patients as well as in patients with proven CAD undergoing various treatment forms such as risk factor reduction or coronary revascularization. In patients following orthotopic heart transplantation, evolving transplant vasculopathy can be detected at an early stage. Quantitative PET imaging at rest allows for detection of myocardial viability since cellular survival is based on maintenance of a minimal perfusion and structural changes correlate to the degree of perfusion reduction. Furthermore, quantitative assessment of the myocardial perfusion reserve detects the magnitude and competence of collaterals in regions with occluded epicardial collaterals and, thus, imaging of several coronary distribution territories in one noninvasive study. The cost of PET in combination with the cost of a cyclotron facility together with the demanding methological problems have limited the availability of perfusion PET to a few sophisticated centers. Therefore, quantitative PET investigations of myocardial perfusion have been performed predominantly for scientific purposes, and the cost-effectiveness of PET in the everyday clinical setting is not yet finally proven. However, the unique possibilities of PET to study non-invasively and quantitatively myocardial perfusion and metabolism as well as cardiac innervation and pharmacokinetics of cardiac drugs have established cardiac PET as a scientific tool of the highest quality for the future.

Coronary Circulation↗

[Treatment of stent restenosis using rotational atherectomy: mechanisms and results].

Restenosis after coronary stent implantation remains one of the major limitations of this treatment modality. At present, redilatation is considered the therapeutic option of choice for focal lesions; however, long restenotic lesions (> 10 mm) do not respond favourably. Despite the emerging concept of intracoronary radiation, encouraging acute procedural results are also reported for different debulking techniques (excimer laser angioplasty, directional coronary atherectomy, and rotational atherectomy, or rotablation). Rotablation has been studied most extensively with acute and long-term results published in a total of 500 patients. Experimental and first clinical data indicate favourable results for the rotablator as compared to balloon angioplasty alone for the treatment of in-stent restenosis. Data from the first two randomised clinical trials (ROSTER and A.R.T.I.S.T. trials) have now been published in abstract form, with conflicting results: whereas the monocenter ROSTER trial suggests a clinical benefit to patients treated by the rotablator, the multicenter A.R.T.I.S.T. trial including nearly 300 patients could not prove a benefit for the rotablator as compared to re-dilatation in patients with diffuse stent restenosis. Currently, rotablation for the treatment of restenosis can not be considered as the first line treatment modality in patients with stent restenosis. As a result of unsatisfying angiographic and clinical long-term results by the use of a variety of treatment modalities in diffuse stent restenosis, prevention of this iatrogenic entity will become mandatory.

Aged↗

Myocardial viability assessment by endocardial electroanatomic mapping: comparison with metabolic imaging and functional recovery after coronary revascularization.

OBJECTIVES: The objective of this study was to compare electroanatomic mapping for the assessment of myocardial viability with nuclear metabolic imaging using positron emission computed tomography (PET) and with data on functional recovery after successful myocardial revascularization. BACKGROUND: Animal experiments and first clinical studies suggested that electroanatomic endocardial mapping identifies the presence and absence of myocardial viability. METHODS: Forty-six patients with prior (> or =2 weeks) myocardial infarction underwent fluorine-18 fluorodeoxyglucose (FDG) PET and Tc-99m sestamibi single-photon emission computed tomography (SPECT) before mapping and percutaneous coronary revascularization. The left ventricular endocardium was mapped and divided into 12 regions, which were assigned to corresponding nuclear regions. Functional recovery using the centerline method was assessed in 25 patients with a follow-up angiography. RESULTS: Regional unipolar electrogram amplitude was 11.0 mV +/- 3.6 mV in regions with normal perfusion, 9.0 mV +/- 2.8 mV in regions with reduced perfusion and preserved FDG-uptake and 6.5 mV +/- 2.6 mV in scar regions (p < 0.001 for all comparisons). At a threshold amplitude of 7.5 mV, the sensitivity and specificity for detecting viable (by PET/SPECT) myocardium were 77% and 75%, respectively. In infarct areas with electrogram amplitudes >7.5 mV, improvement of regional wall motion (RWM) from -2.4 SD/chord +/- 1.0 SD/chord to -1.5 SD/chord +/- 1.1 SD/chord (p < 0.01) was observed, whereas, in infarct areas with amplitudes <7.5 mV, RWM remained unchanged at follow-up (-2.3 SD/chord +/- 0.7 SD/chord to -2.4 SD/chord +/- 0.7 SD/chord). CONCLUSIONS: These data suggest that the regional unipolar electrogram amplitude is a marker for myocardial viability and that electroanatomic mapping can be used for viability assessment in the catheterization laboratory.

Aged↗

Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.

AIMS: Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS: Angiographic and intravascular ultrasound studies were performed at the 6 month follow-up in 131 consecutive native coronary lesions of 131 patients treated with 50 Multi-Link stents, 40 InFlow stents and 41 Palmaz-Schatz stents. Lumen and stent cross-sectional areas (CSA) were measured at 1 mm axial increments. Mean intimal hyperplasia cross-sectional area (stent CSA-lumen CSA) and mean intimal hyperplasia thickness were calculated. Intravascular ultrasound demonstrated different levels of intimal hyperplasia proliferation for the three stents. Mean intimal hyperplasia thickness was 0.16+/-0.08 mm for Multi-Link stents, 0.26+/-0.19 mm for Palmaz-Schatz stents and 0.39+/-0.14 mm for Inflow stents (P<0.001). Multivariate analysis proved that stent type was the only independent predictor of intimal hyperplasia thickness at follow-up (P<0.001). CONCLUSION: Coronary stent design has a significant impact on subsequent intimal hyperplasia after implantation into atherosclerotic human coronary arteries. The corrugated ring design of the Multi-Link stent proved to result in less tissue proliferation at 6-month follow-up than the tubular slotted design of Palmaz-Schatz and InFlow stents.

Coronary Disease↗

The impact of high pressure vs low pressure stent implantation on intimal hyperplasia and follow-up lumen dimensions; results of a randomized trial.

AIMS: Histology and retrospective clinical studies have indicated that the amount of neointimal hyperplasia is dependent on the arterial injury induced during stent implantation. This study analysed, prospectively, the impact of high vs low pressure stent implantation techniques using a second generation stent on intimal hyperplasia and follow-up lumen dimensions. METHODS AND RESULTS: Post-intervention and follow-up (mean[+/-SD] 5.5+/-1.3 months) angiographic and intravascular ultrasound studies were performed on 120 Multi-Link HP stents randomized to implantation at either low (8-10 atm) or high (16-20 atm) pressure. Intravascular ultrasound measurements of the external elastic membrane, stent, and lumen cross-sectional area were performed at 1 mm axial increments. Peri-stent plaque+media cross-sectional area (external elastic membrane-stent cross-sectional area, intimal hyperplasia cross-sectional area (stent-lumen cross-sectional area at follow-up), intimal hyperplasia thickness and peri-stent tissue growth cross-sectional area (Deltapersistent plaque+media cross-sectional area) were calculated. Intravascular ultrasound demonstrated a larger minimal lumen cross-sectional area post-intervention in the high pressure group (7.3+/-2.0 vs 6.2+/-1.8 mm(2), P<0.001, high vs low pressure group, respectively). At follow-up, the mean intimal hyperplasia cross-sectional area (1.7+/-0.9 vs 1.5+/-0.8 mm(2), P=0.708), the mean intimal hyperplasia thickness (0.16+/-0.12 vs 0.16+/-0.12 mm, P=0.818) and peri-stent tissue proliferation cross-sectional area were not greater in the high pressure group. Thus, the minimal lumen cross-sectional area at follow-up continued to be greater (5.5+/-2.0 vs 4.7+/-1.7 mm(2), P=0.038) in the high pressure group. CONCLUSIONS: High pressure stent implantation results in greater stent expansion even with the less rigid second generation Multi-Link stent. Larger lumen dimensions persist at follow-up, while intimal hyperplasia is not significantly greater after high pressure implantation compared to the low pressure technique.

Coronary Angiography↗

Infectious agents in coronary lesions obtained by endatherectomy: pattern of distribution, coinfection, and clinical findings.

BACKGROUND: Cytomegalovirus (CMV), Chlamydia pneumoniae (C. pneumoniae), and Helicobacter pylori (H. pylori) have been implicated in atherosclerosis and restenosis after angioplasty. The patterns of distribution within coronary lesions and possible coinfections of these pathogens in the coronary vasculature had not previously been evaluated. DESIGN: A prospective, observational clinical study. METHODS: Large coronary specimens (9-105 mm long) were obtained by endatherectomy of 53 patients undergoing aortocoronary bypass surgery. Samples were taken from two different sites of every lesion, resulting in a total of 106 probes. Presence of each pathogen was determined by polymerase chain reaction, subsequent hybridization, and DNA sequencing. RESULTS: Cytomegalovirus and C. pneumoniae were detected in 30 and 32% of the samples, respectively; H. pylori was not detectable. The pathogens were not homogeneously distributed. A concurrent infection with both pathogens was observed in five of 106 (5%) lesions and five of 53 (9%) patients. Restenotic lesions were more often found in specimens in which cytomegalovirus was detected (five of 16 versus two of 37). Patients with C. pneumoniae-positive coronary lesions more commonly presented with unstable angina. CONCLUSIONS: Inhomogeneous infections with cytomegalovirus and C. pneumoniae of coronary atherosclerotic lesions are found to be prevalent when serial analysis is performed. Concurrent infection with both pathogens occurs coincidentally; however, possible clinical implications of this new observation and the pathogenic impact on atherosclerosis need further investigation.

Aged↗

[An approach for comparative quantification of myocardial blood flow (O-15-H2O-PET), perfusion (Tc-99m-tetrofosmin-SPECT) and metabolism (F-18-FDG-PET)].

AIM: In the present study a new approach has been developed for comparative quantification of absolute myocardial blood flow (MBF), myocardial perfusion, and myocardial metabolism in short-axis slices. METHODS: 42 patients with severe CAD, referred for myocardial viability diagnostics, were studied consecutively with 0-15-H2O PET (H2O-PET) (twice), Tc-99m-Tetrofosmin SPECT (TT-SPECT) and F-18-FDG PET (FDG-PET). All data sets were reconstructed using attenuation correction and reoriented into short axis slices. Each heart was divided into three representative slices (base, midventricular, apex) and 18 ROIs were defined on the FDG PET images and transferred to the corresponding H2O-PET and TT-SPECT slices. TT-SPECT and FDG-PET data were normalized to the ROI showing maximum perfusion. MBF was calculated for all left-ventricular ROIs using a single-compartment-model fitting the dynamic H2O-PET studies. Microsphere equivalent MBF (MBF_micr) was calculated by multiplying MBF and tissue-fraction, a parameter which was obtained by fitting the dynamic H2O-PET studies. To reduce influence of viability only well perfused areas (> 70% TT-SPECT) were used for comparative quantification. RESULTS: First and second mean global MBF values were 0.85 ml x min-1 x g-1 and 0.84 ml x min-1 x g-1, respectively, with a repeatability coefficient of 0.30 ml x min-1 x g-1. After sectorization mean MBF_micr was between 0.58 ml x min-1 x ml-1 and 0.68 ml x min-1 x ml-1 in well perfused areas. Corresponding TT-SPECT values ranged from 83% to 91%, and FDG-PET values from 91% to 103%. All procedures yielded higher values for the lateral than the septal regions. CONCLUSION: Comparative quantification of MBF, MBF_micr, TT-SPECT perfusion and FDG-PET metabolism can be done with the introduced method in short axis slices. The obtained values agree well with experimentally validated values of MBF and MBF_micr.

Coronary Circulation↗

Cardioprotective effects of the Na(+)/H(+) exchange inhibitor cariporide in patients with acute anterior myocardial infarction undergoing direct PTCA.

BACKGROUND: Activation of Na(+)/H(+) exchange in myocardial ischemia and/or reperfusion leads to calcium overload and myocardial injury. Experimental studies have shown that Na(+)/H(+) exchange inhibitors can attenuate Ca(2+) influx into cardiomyocytes. We therefore performed a multicenter, randomized, placebo-controlled clinical trial to test the hypothesis that inhibition of Na(+)/H(+) exchange limits infarct size and improves myocardial function in patients with acute anterior myocardial infarction (MI) treated with direct PTCA. METHODS AND RESULTS: One hundred patients were randomized to receive placebo (n=51) or a 40-mg intravenous bolus of the Na(+)/H(+) exchange inhibitor cariporide (HOE 642) (n=49) before reperfusion. Global and regional left ventricular functions were analyzed by use of paired contrast left ventriculograms performed before and 21 days after PTCA and myocardial enzymes (ie, creatine kinase ¿CK, CK-MB, and LDH) as markers for myocardial tissue injury were evaluated. At follow-up, the ejection fraction was higher (50% versus 40%; P<0.05) and the end-systolic volume was lower (69.0 versus 97.0 mL; P<0.05) in the cariporide group. Significant improvements in some indices of regional wall motion abnormalities were observed, such as the percentage of chords with hypokinesis < -2 SD (P=0.045) and the severity of hypokinesis in the border zone of the infarct region (P=0.052). In addition, CK, CK-MB, or LDH release was significantly reduced in the cariporide patients. CONCLUSIONS: Our findings suggest that inhibition of Na(+)/H(+) exchange by cariporide may attenuate reperfusion injury and thereby improve the recovery from left ventricular dysfunction after MI.

Adult↗

Abciximab inhibits the migration and invasion potential of human coronary artery smooth muscle cells.

In the EPIC trial, high-risk patients received the integrin receptor antagonist abciximab v placebo during and for 12 h following percutaneous coronary intervention with a significant 23% decrease of repeat revascularisation at 6 months. However, EPILOG and CAPTURE trials could not confirm these promising long-term results. Recently presented data from the EPISTENT trial suggested a beneficial effect of abciximab on restenosis in patients with diabetes. Based on these divergent results the aim of this study was to test whether alpha v beta 3 receptor blockade by abciximab could cause inhibition of human coronary smooth muscle cell (hcSMC) proliferation, migration, and invasion which represent crucial steps during restenosis development. In contrast to quiescent hcSMCs, proliferating cells were capable to migrate towards chemoattractive stimuli and even capable to invade through a basement membrane equivalent. Abciximab and LM609, an alpha v beta 3 specific inhibiting antibody, caused only a modest dose-dependent inhibition of hcSMC proliferation. On the contrary, the chemotactic and invasive potential of hcSMCs was significantly inhibited by abciximab administration 24 h prior to and during migration. (IC(50)=33.0 microg/ml for chemotaxis and IC(50)=0.5 microg/ml for invasion). For LM609 similar results were obtained. Administration of the drugs just during migration without pretreatment inhibited migration equally but invasion to a lower extent (abciximab: IC(50)=32.6 microg/ml for chemotaxis and IC(50)=44.9 microg/ml for invasion; LM609 IC(50)=3.1 microg/ml for chemotaxis and IC(50)=2.0 microg/ml for invasion). The attachment to the extracellular matrix proteins collagen I, collagen IV, laminin and vitronectin was not influenced. Pretreatment for 24 h with abciximab or LM609 did not cause a downregulation of the alpha v beta 3-integrin receptor. The results of this study indicate that the alpha v beta 3 antagonist abciximab is a potent inhibitor of hcSMC migration and invasion which could explain the observed lower reintervention rate after PTCA and stent implantation.

Abciximab↗

Evaluation of the SOFA score: a single-center experience of a medical intensive care unit in 303 consecutive patients with predominantly cardiovascular disorders. Sequential Organ Failure Assessment.

OBJECTIVE: To evaluate the use of the Sequential Organ Failure Assessment (SOFA) score, the total maximum SOFA (TMS) score, and a derived variable, the deltaSOFA (TMS score minus total SOFA score on day 1) in medical, cardiovascular patients as a means for describing the incidence and severity of organ dysfunction and the prognostic value regarding outcome. DESIGN: Prospective, clinical study. SETTING: Medical intensive care unit in a university hospital. PATIENTS: A total of 303 consecutive patients were included (216 men, 87 women; mean age 62 +/- 12.6 years; SAPS II 26.2 +/- 12.7). They were evaluated 24 h after admission and thereafter every 24 h until ICU discharge or death between November 1997 and March 1998. Readmissions and patients with an ICU stay shorter than 12 h were excluded. MAIN OUTCOME MEASURE: Survival status at hospital discharge, incidence of organ dysfunction/failure. INTERVENTIONS: Collection of clinical and demographic data and raw data for the computation of the SOFA score every 24 h until ICU discharge. MEASUREMENTS AND MAIN RESULTS: Length of ICU stay was 3.7 +/- 4.7 days. ICU mortality was 8.3% and hospital mortality 14.5%. Nonsurvivors had a higher total SOFA score on day 1 (5.9 +/- 3.7 vs. 1.9 +/- 2.3, p < 0.001) and thereafter until day 8. High SOFA scores for any organ system and increasing number of organ failures (SOFA score > or = 3) were associated with increased mortality. Cardiovascular and neurological systems (day 1) were related to outcome and cardiovascular and respiratory systems, and admission from another ICU to length of ICU stay. TMS score was higher in nonsurvivors (1.76 +/- 2.55 vs. 0.58 +/- 1.39, p < 0.01), and deltaSOFA/total SOFA on day 1 was independently related to outcome. The area under the receiver-operating characteristic curve was 0.86 for TMS, 0.82 for SOFA on day 1, and 0.77 for SAPS II. CONCLUSIONS: The SOFA, TMS, and deltaSOFA scores provide the clinician with important information on degree and progression of organ dysfunction in medical, cardiovascular patients. On day 1 both SOFA score and TMS score had a better prognostic value than SAPS II score. The model is closely related to outcome and identifies patients who are at increased risk for prolonged ICU stay.

Cardiovascular Diseases↗

Diagnosis of myocardial viability by dual-head coincidence gamma camera fluorine-18 fluorodeoxyglucose positron emission tomography with and without non-uniform attenuation correction.

This study assessed a dual-head coincidence gamma camera (hybrid PET) equipped with single-photon transmission for myocardial fluorine-18 fluorodeoxyglucose (FDG) imaging by comparing this technique with conventional positron emission tomography (PET) using a dedicated ring PET scanner. Twenty-one patients were studied with dedicated FDG ring PET and FDG hybrid PET for evaluation of myocardial glucose metabolism, as well as technetium-99m tetrofosmin single-photon emission tomography (SPET) to estimate myocardial perfusion. All patients underwent transmitted attenuation correction using germanium-68 rod sources for ring PET and caesium-137 point sources for hybrid PET. Ring PET and hybrid PET emission scans were started 61+/-12 and 98+/-15 min, respectively, after administration of 154+/-31 MBq FDG. Attenuation-corrected images were reconstructed iteratively for ring PET and hybrid PET (ac-hybrid PET), and non-attenuation-corrected images for hybrid PET (non-ac-hybrid PET) only. Tracer distribution was analysed semiquantitatively using a volumetric vector sampling method dividing the left ventricular wall into 13 segments. FDG distribution in non-ac-hybrid PET and ring PET correlated with r=0.36 (P<0.0001), and in ac-hybrid PET and ring PET with r=0.79 (P<0.0001). Non-ac-hybrid PET significantly overestimated FDG uptake in the apical and supra-apical segments, and underestimated FDG uptake in the remaining segments, with the exception of one lateral segment. Ac-hybrid PET significantly overestimated FDG uptake in the apical segment, and underestimated FDG uptake in only three posteroseptal segments. A three-grade score was used to classify diagnosis of viability by FDG PET in 136 segments with reduced perfusion as assessed by SPET. Compared with ring PET, non-ac-hybrid PET showed concordant diagnoses in 80 segments (59%) and ac-hybrid PET in 101 segments (74%) (P<0.001). Agreement between ring PET and non-ac-hybrid PET was best in the basal lateral wall and in the apical-septal segment (80%-100%), and lowest in the apical, supra-apical and posteroseptal segments (41%-55%). Ac-hybrid PET showed highest agreement in the lateral wall (89%-100%), and lowest agreement in the apical and the basal septal segments (59%-67%). In conclusion, non-uniform attenuation correction with singles transmission significantly improves the diagnostic accuracy of myocardial dual-head gamma camera coincidence imaging with FDG. However, results equivalent to those obtained with ring PET cannot yet be attained, even if attenuation correction is applied. New rebinning algorithms for three-dimensional data may further improve the performance of ac-hybrid PET and should be evaluated in future studies.

Adult↗

Suramin inhibits proliferation of human arterial smooth muscle cells in vitro: potential drug for prevention of restenosis by local drug delivery.

PURPOSE: Suramin is known to inhibit proliferation of various tumor cells. This study was performed to investigate the effect of suramin on proliferating human arterial smooth muscle cells (HASMC) and thus to examine its suitability for the prevention of restenosis. METHOD: Proliferation of HASMC was stimulated with human whole blood serum (HWBS), as well as with platelet-derived growth factor (PDGF) and basic fibroblast growth factor (bFGF). Proliferation was assessed by measuring DNA synthesis and cell viability was assessed by measuring mitochondrial activity. RESULTS: Suramin exerted a strong attenuating effect on the proliferation stimulators HWBS, PDGF, and bFGF. A suramin concentration of 0.5 mmol/L, which is approximately twice the dosage used for systemic application, was sufficient for complete neutralization of proliferation stimulation by 10% HWBS added to the cell culture medium. CONCLUSION: The authors' data demonstrate a strong proliferation inhibiting effect of suramin on HASMC in vitro. Because it is known to interact not only with one but with a multitude of relevant growth factors, these results make suramin a most interesting substance for local application for prevention of hyperplastic neointima formation.

Arteries↗