Search PubMed⌕ Search

Biomedical subjects

J Zhu

Publications and source records attributed to J Zhu.

819 records · Page 46Linked to original sources

[Cloning and characterization of a novel mouse short-chain dehydrogenase/reductases cDNA mHsdl2#, encoding a protein with a SDR domaid and a SCP2 domain].

The short-chain dehydrogenases/reductases (SDRs) play important roles in body's metabolism. We cloned a novel mouse SDR cDNA which encodes a deduced HSD-like protein with a conserved SDR domain and a SCP2 domain. The 1.8 kb cDNA consists of 11 exons and is mapped to mouse chromosome 4B3. The corresponding gene is widely expressed in normal mouse tissues and its expression level in liver increases after inducement with cholesterol food. The predicted mouse HSDL2 protein, which has a peroxisomal target signal, is localized in the cytoplasm of NIH 3T3 cells.

Amino Acid Sequence↗

Studies on the growth metabolism of Bacillus thuringiensis and its vegetative insecticidal protein engineered strains by microcalorimetry.

The metabolic power-times curves of Bacillus thuringiensis and its vegetative insecticidal protein engineered strains were determined at 30 degrees C by using a thermal activity monitor air Isothermal Microcalorimeter, ampoule method. From the power-times curves, the maximum power (Pmax) in the log phase, the growth rate constant (k), the generation times (tG), the time of the maximum power (tmax), the heat effects (Qlog) for log phase, and the total heat effect in 45 h (Qtotal) of B. thuringiensis strains can be obtained. The results indicate that their power-times curves are different. The relationship between their metabolic power-times curves and character of bacteria metabolism, and thermokinetics and gene expression were analyzed and discussed. The character of the bacteria power-times curves reflected the physiologic character of gene expression. The microcalorimetric method proved to be a reliable and sensitive tool for the assessment of the growth metabolism, the heat output in bacteria and its engineered strains. The determination of the thermokinetic character is beneficial to the control of fermentation.

Animals↗

Epidural butorphanol augments lidocaine sensory anesthesia during labor.

To determine the efficacy and safety of epidural butorphanol combined with lidocaine, 50 healthy parturients were studied during labor and delivery. All patients received a test dose of 3 ml 1.5% lidocaine with 1:200,000 epinephrine. Patients were then randomly assigned to receive 7 ml of one of two epidural regimens in a double-blind fashion: Group 1 patients received 1.5% lidocaine plus 1 mg butorphanol plus 1:300,000 epinephrine; Group 2 patients received 1.5% lidocaine plus 1:300,000 epinephrine. Each group consisted of 25 patients. The study ended at the time of redosing. All subsequent epidural injections were made with one bolus of plain 0.25% bupivacaine followed by continuous infusion of 0.125% bupivacaine. Duration of anesthesia was significantly longer for Group 1 compared to Group 2 (p less than 0.01), 124 +/- 8 minutes versus 99 +/- 6 minutes (mean +/- SEM). There were no difference between groups in duration of first and second stages of labor, method of delivery or neonatal outcome. Umbilical cord acid-base status and neurologic adaptive capacity scores did not differ significantly between the two groups. The authors conclude that adding small doses of butorphanol to epidural lidocaine during labor is effective and safe.

Adult↗

Continuous infusion epidural anesthesia during labor: a randomized, double-blind comparison of 0.0625% bupivacaine/0.002% butorphanol and 0.125% bupivacaine.

The efficacy of pain relief and the maternal and neonatal effects of continuous epidural infusion of 0.0625% bupivacaine/0.002% butorphanol was compared with the infusion of 0.125% bupivacaine alone in a randomized, double-blind study of 32 women in labor. A test dose of 2 ml 0.5% bupivacaine was given to every patient and followed by two epidural regimens in randomized, double-blind manner. Group B-B (bupivacaine/butorphanol) patients received 7.5 ml 0.125% bupivacaine plus 1 mg butorphanol (0.5 ml) followed by an infusion of 0.0625% bupivacaine/0.002% butorphanol at a rate of 12 ml/hour; Group B (bupivacaine alone) patients received 8 ml 0.25% bupivacaine followed by an infusion of 0.125% bupivacaine at a rate of 12 ml/hour. A bolus of 5 ml 0.125% bupivacaine or 0.0625% bupivacaine was given to Group B or B-B, respectively, if additional pain relief was required. Infusion of B-B combination resulted in similar pain relief and fewer patients with motor block than bupivacaine alone; 12% versus 38% in Groups B-B and B, respectively, had motor weakness. A smaller dose of bupivacaine was used in the B-B group compared to the B group; 71 +/- 14 versus 99 +/- 13 mg (mean +/- SEM; p less than 0.05). Progress of labor and the mode of delivery did not differ significantly between the two groups. All infants were vigorous and had normal acid-base status and neurologic adaptive capacity scores. Butorphanol appears to be useful as an adjunct to epidural bupivacaine for continuous epidural infusion during labor without adversely affecting the mother or the neonate.

Adult↗

Epidural morphine or butorphanol augments bupivacaine analgesia during labor.

To determine the efficacy and the safety of epidural morphine or butorphanol combined with bupivacaine, 40 healthy parturients were studied during labor and delivery. All patients received an epidural test dose of 2 ml of 0.5% bupivacaine. Patients were then randomly assigned to receive one of four epidural regimens in a double-blind fashion: 0.25% bupivacaine + 1 mg butorphanol (Group I), 0.25% bupivacaine + 2 mg butorphanol (Group II), 0.25% bupivacaine + 2 mg morphine (Group III), or 0.25% bupivacaine alone (Group IV). Each group consisted of ten patients. All subsequent epidural injections were with plain 0.25% bupivacaine. Duration of analgesia was significantly longer for groups I, II, and III when compared to group IV (p less than or equal to .01); 139 +/- 111, 141 +/- 14, 199 +/- 29, and 96 +/- 6 minutes, X +/- SEM respectively. Quality of analgesia was significantly better in groups I, II, and III when compared with group IV. There were no differences between groups in duration of first and second stages of labor, uterine activity, or method of delivery. Thirty percent of patients in the morphine group (group III) developed mild pruritus that did not require any treatment. All neonates were vigorous at 5 minutes and had good Apgar Scores, umbilical cord acid base status, and Neurological Adaptive Capacity Scores. The authors conclude that adding small doses of either morphine or butorphanol to epidural bupivacaine during labor is effective and safe. Butorphanol may be preferable since none of the patients experienced pruritus.

Adult↗

Bupivacaine/butorphanol/epinephrine for epidural anesthesia in obstetrics: maternal and neonatal effects.

The effects of epidural bupivacaine/butorphanol with and without 1:300,000 epinephrine on maternal analgesia, uterine activity, progress of labor, fetal heart rate, maternal blood pressure, newborn Apgar scores, neonatal acid base status and the neurologic and adaptive capacity scores (NACS) were compared in 33 parturients during labor and delivery. Patients in Group I (n = 17) received 0.25% bupivacaine plus 1 mg butorphanol plus 1:300,000 epinephrine, and those in Group II (n = 16) received the same agents without the epinephrine. Addition of epinephrine to bupivacaine/butorphanol did not have any adverse effects on uterine activity, duration of first or second stages of labor or fetal heart rate parameters. The incidence of maternal hypotensive episodes did not differ significantly between the two groups of patients. Apgar scores, neonatal acid base status and the NACS were equally good and did not differ significantly between the two groups. Duration of analgesia was significantly longer in Group I as compared to Group II patients (177.5 +/- 11 versus 131.8 +/- 10 minutes, p less than 0.01). It is concluded that addition of epinephrine 1:300,000 to bupivacaine/butorphanol during epidural anesthesia in the normal parturient has no adverse effects on the mother, fetus or neonate or on the progress of labor and it significantly prolongs the duration of analgesia.

Acid-Base Equilibrium↗

Liquid chromatographic determination of RH-5992, an ecdysone agonist, in some forestry matrixes.

A liquid chromatographic method is described for the analysis of RH-5992 (N'-t-butyl-N'-[3,5-dimethyl-benzoyl]-N- [-ethylbenzoyl]hydrazine) from various terrestrial and aquatic forestry matrixes and stream water. The processed soils, litter, oak foliage, sediment, aquatic plants, and fish were extracted with a mixture of acetone and water; balsam fir needles were extracted with acidified methanol solution; stream water was extracted with dichloromethane. Aliquots of crude extracts were solvent partitioned, concentrated, and cleaned up by using Florisil or Prepsep-NH2 columns. After fractional elution of the columns with hexane-ethyl acetate as the eluent, the eluates were analyzed on a liquid chromatograph equipped with a diode-array UV detector set at 236 nm, using an RP-8, 10 microns column with a mobile phase of acetonitrile-dioxane-water. Fir needles required methanol in addition to the 3 solvents in the mobile phase mixture. Water samples did not require any column cleanup. Mean recoveries for the analyte ranged from 84 to 98%, with coefficients of variation from 5 to 10%. Limits of detection (LOD) and limits of quantitation (LOQ) ranged from 0.004 to 0.030 ppm and from 0.013 to 0.101 ppm, respectively, for various forestry matrixes. LOD and LOQ for natural waters were 0.050 and 0.166 ppb, respectively.

Chromatography, Liquid↗

An experimental study about the incorrect electrophysiological evaluation following peripheral nerve injury and repair.

OBJECTIVE: This experiment was designed to explore the reasons of incorrect electrophysiological evaluation following peripheral nerve repair. METHODS: Twenty-four New Zealand white rabbits were used and divided into 2 groups. The first group of animals underwent severance of gastrocnemius muscle nerve and only the medial branch of the nerve was anastomosed. The second group of rabbits underwent severance of the muscle nerve as well as sural nerve, then the proximal end of the sural nerve was anastomosed to the distal end of the muscle nerve. Electrophysiological and morphological methods were used to study these models 3 months after the operations. RESULTS: Electrophysiologic comparison of muscle action potential for group A and B showed a significant difference in the values (p < 0.05). Morphologic studies showed that the muscle weights of group B were significantly lower than those of group A, but the myelin thickness failed to show any statistical difference between the two groups. CONCLUSION: Results suggested that one of the sources causing incorrect electrophysiological evaluation could be misdirected regeneration, resulting from a sensory fascicle anastomosing to a motor one or vice versa. The unfunctional regeneration showed low values of muscle action potentials (p < 0.05) as well as excessive fibrillation potentials, and marked atrophy of the muscles (p < 0.05).

Anastomosis, Surgical↗