Search PubMed⌕ Search

Biomedical subjects

J Y Rho

Publications and source records attributed to J Y Rho.

42 records · Page 3Linked to original sources

Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements.

An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.

Aged↗

The fabric dependence of the orthotropic elastic constants of cancellous bone.

It has been proposed that the orthotropic elastic constants of cancellous bone depend upon a tensorial measure of anisotropy called fabric as well as the tissue's structural density. Cowin (1985, Mechanics Mater, 4, 137-147; 1986, J. biomech. Engng 108, 83-88) developed explicit relationships for the elastic constant, structural density and fabric relationship. In this study the orthotropic elastic moduli, structural density, and fabric components were measured for 11 cancellous bone specimens from five bovine femora and for 75 specimens from three human proximal tibiae and fitted to these relationships using a least squares analysis. The relationships explained between 72 and 94% of the variance in the elastic constants. The relationships between the elastic constants and squared or cubed power functions of structural density had better predictive value over the entire distribution of the data than did expressions with linear functions of structural density.

Aged↗

Anatomical variation of orthotropic elastic moduli of the proximal human tibia.

The anatomical variation of orthotropic elastic moduli of the cancellous bone from three human proximal tibiae was investigated using an ultrasonic technique. With this technique, it was possible to measure three orthogonal elastic moduli and three shear moduli from cubic specimens of cancellous bone as small as 8 mm per side. Correlation with mechanical tensile testing has shown this technique to offer a precise measure of cancellous modulus (Eten = 0.94Eult + 144.6 MPa, r2 = 0.96, n = 34). The cancellous bone of the proximal tibia was found to be very inhomogeneous, with the axial modulus ranging between 340 and 3350 MPa. A course map is presented, showing measured Young's moduli as a function of anatomical position. The anisotropy of the cancellous bone, determined by the relative differences between the three orthogonal moduli, was shown to be relatively constant over the entire range of cancellous densities tested. The relationship between the axial elastic modulus and the apparent density was found to be approximately linear, as reported by others for proximal tibial cancellous bone.

Aged↗

Elastic modulus of trabecular bone material.

An ultrasonic technique was used to measure both the elastic modulus (Young's modulus) of trabecular bone material and the elastic modulus of the cancellous structure. The average trabecular modulus, measured on specimens obtained from three human and one bovine distal femora, was 13.0 GPa (S.D. 1.47) and 10.9 GPa (S.D. 1.57), respectively. On human specimens the structural elastic modulus was found to be related to the structural (apparent) density raised to the 1.88 power. The elastic modulus from the bovine specimens showed a more linear relationship with the density of the cancellous structure (density raised to the 1.57 power).

Animals↗

Micromechanical properties of epiphyseal trabecular bone and primary spongiosa around the physis: an in situ nanoindentation study.

The elastic modulus and hardness of the mineralized bone around the growth plate was measured to determine its regional micromechanical properties. Multiple nanoindentation tests, >10 sessions, with depths ranging from 100 to 1,000 nm at loading rates of 12.5 and 750 microN/s, were performed on the trabecular bone in the epiphysis, trabecular bone at the junction of the physis and epiphysis, primary spongiosa in the metaphysis, and surrounding cortical bone of the distal femur of 300-gm Sprague-Dawley rats. The indentation load-displacement data obtained in these tests were analyzed to determine the elastic modulus and hardness of the tissues. The nanoindentation results highlighted the regional variations in the material properties of the mineralized tissues around the growth plate. The primary spongiosa had a lower elastic modulus and hardness than both epiphyseal trabecular and cortical bone (p < 0.01). A relatively well-defined thick trabecular band at the physeal-epiphyseal junction had modulus and hardness values comparable to those of cortical bone (p > 0.05). These findings support the hypothesis that the primary spongiosa has micromechanical properties that are significantly lower than the epiphyseal trabecular bone. On this basis, it is speculated that the fracture patterns commonly seen in patients with physeal injuries are influenced by the micromechanical properties of these tissues, as well as by the nature and direction of the applied force.

Analysis of Variance↗