Publications and source records attributed to J Y Giraud.

13 recordsLinked to original sources

A dosimetric comparison of two multileaf collimator designs.

We present the results of measurements designed to compare two different multileaf collimator (MLC) designs using a novel evaluation technique. The MLC designs evaluated were: a "single-focused" MLC (SF-MLC) mounted below the jaws, and a "double-focused" MLC, which is a complete replacement for the lower jaws. The ability of each MLC to conform isodose lines to a prescribed field edge (PFE) was evaluated using film dosimetry. Circular fields, centered on axis and off axis, were used because they produce a range of "angles of approach" between the MLC leaves and the PFE. They also have the advantage that for an ideal field shaping system the resulting isodoses are concentric perfect circles, a well-defined basis for evaluation. The amplitude of the oscillations of the 50% isodose line about the PFE and the penumbra width as determined by the 20%, 80%, and 90% isodose lines was examined. We observe that the 50% isodose line oscillates around the PFE with greater amplitude for SF-MLC. We attribute this, at least in part, to the rounded ends of the SF-MLC leaves. However, the SF-MLC has a noticeably sharper penumbra, which we attribute to its position further from the source. We conclude that these results are relevant for accurate dosimetric modeling of these devices.

Equipment Design↗

[Absorbed dose during helical acquisition CT. Effect of acquisition parameters].

PURPOSE: European directive 97/43 specifies that the dose delivered to the patient during a radiological procedure should be estimated. In order to prepare for implementation of this new regulation, we have studied the dose delivered during spiral CT acquisition. MATERIALS AND METHODS: We have studied the influence of slice thickness, pitch, tube voltage and intensity, and acquisition volume length. We present measurements for single and dual detector CT scanners. We used a pencil ionization chamber to measure air kerma. We measured absorbed dose in water with a waterproof ionization chamber set in a semi-customized phantom filled with water. Chambers were set on the rotation axis of the CT scanners. We studied the dose outside the acquisition volume. RESULTS: We quantified the influence of each parameter on the absorbed dose. We used our measurements to calculate the dose for different acquisition protocols. Also we evaluated the dose to organs distant from the acquisition area. CONCLUSION: This study is one step toward a systematic estimation of the dose delivered to patient during helical CT exams. To use these results in daily practice, we have to develop software using our measurements.

Equipment Design↗

Patient set-up using portal images: 2D/2D image registration using mutual information.

OBJECTIVE: Conformal radiation therapy requires accurate patient set-up for each fraction delivery. Electronic portal imaging devices allow the acquisition of portal images just before and even during dose delivery. However, the quantitative interpretation of these images in determining and correcting the patient's position remains uncertain, and automated methods are therefore being developed. Such methods must be usable for the different radiation therapy techniques. They must be robust and as automated as possible for use in clinical routines. This work was undertaken to establish the feasibility of 2D/2D registration for portal/portal and portal/simulator images in radiotherapy. MATERIALS AND METHODS: This paper describes an automated method based on the combination of calibration algorithms and pixel-based registration algorithms. We present experiments with the different imaging techniques, some of which use a phantom with and without a gold standard. Preliminary results obtained using patient data are also presented and discussed. RESULTS: The results obtained with a phantom demonstrated that this automated method for 2D/2D registration is fast, accurate, and robust, even in the case of blurred images for small treatment fields. CONCLUSIONS: Mutual information is a feasible method for 2D/2D portal/portal and portal/simulator image registration in radiotherapy.

Algorithms↗

[Patient positioning and its verification: justification, state of the art of the classical practices].

Patient immobilization is considered an important part of the quality control program in radiation therapy. The need for patient immobilization according to the symptoms, ensuring both reproducibility and comfort, is described in the recommendations for level 1 published by the SFPM (Société française de physique médicale) and the SFRO (Société française de radiothérapie oncologique). A customized device, associated with regular controls, is required for level 2. Customized procedures are mandatory in clinical practice for head and neck and brain treatments. Internal margins and movements of patients must be analyzed and controlled as deviations of CTV placement relative to the isocenter of linacs. They could be reduced with efficient positioning devices and accurate customized immobilization systems. Different devices could be used according to tumor locations. Except for subclavicular tumors, their efficacy remains controversial.

Abdominal Neoplasms↗

[Image fusion methods for the repositioning of the patient in radiotherapy].

Conformal radiotherapy requires the accurate and reproducible setup of the patient for each fraction delivery. Megavoltage imaging could enable this. This requires the development of image processing and data fusion algorithms. We describe an automated method based on the use of mutual information for registration. Such a method does not require any preliminary segmentation of the images. This method has been extensively tested on phantom as well as on some patient data. The obtained results demonstrated that this automated method for 2D/2D registration is rapid, accurate and robust even in the case of blurred images for small treatment fields.

Humans↗

The use of a semi-customized phantom for verification of conformal plans.

We have developed a technique for inverse treatment planning of prostate therapy designed to improve the degree of conformation between the dose distribution and the target volume. We compared the inverse plan with a "standard" four-field box technique as well as a four-field technique using oblique fields ("cross technique"). We validated the dosimetry of the inverse plan using Fricke gel solution in phantom specifically designed for this purpose. The phantom is a Plexiglas tank with a cross section, which approximates the dimensions of the pelvis. Anatomical data from computed tomography (CT) images of a patient were used to simulate organs in our phantom. This allows us to calculate dose distributions with the external geometry of the phantom and internal anatomy of the patient. Dose-volume histograms (DVHs) for the three different plans were calculated. The phantom containing the Fricke gel was irradiated according to the inverse plan. Magnetic resonance (MR) images was used to determine the dose distribution delivered to the phantom. We observe, on DVHs, that the inverse plan significantly reduces the dose to the rectum and the bladder but slightly increases the inhomogeneity inside the target volume. Correlation is good between isodoses on MR images and calculated isodoses. We conclude that inverse planning software can greatly improve the conformal degree of treatment to the prostate. This technique could be applied to other complex anatomic sites at which dose to organs at risk is a limiting factor and increased dose to the target volume is indicated. Our phantom and the Fricke gel solution are convenient to carry out validation of conformal treatments.

Humans↗

[Survey of the use of contention shells in Centre-Rhône-Alpes area].

Contention shells are frequently used in radiotherapy. They allow improvements in the reproducibility of treatments and take part in quality assurance. The aim of our survey is to establish how centers use contention masks. Ninety-five percent of the centers questioned use contention masks. The fixation device is in most cases made of Plexiglas. The masks are always made of thermoplastics materials with low modeling temperature. They are made just before simulation or scanner by a radiographer. The surface dose problem can be overcome by two different techniques. One consists in the stretching of the material to reduce the density. The other consists of cutting out the mask where the irradiation fields are projected. Whatever the technique, there is a loss of rigidity of the mask, which means the immobilization is not so effective. Despite drawbacks, contention masks have an important role in the quality insurance in radiotherapy.

Biomechanical Phenomena↗

Patient setup optimization for external conformal radiotherapy.

The aim of conformal radiotherapy is to deliver precisely a specific dose of radiation to a planning target volume, concurrently radiating as little healthy tissue and organs as possible. This can be accomplished only with the accurate positioning of the patient with respect to the radiotherapy system. In this paper, we describe a system to achieve a higher overall accuracy in the delivery of a prostatic radiation boost for treatment of carcinoma of the prostate. The system is based on the use of ultrasound images for measuring the actual position of the patient's prostate just before the radiation. Since these images are registered with pretreatment computed tomography or magnetic resonance imaging, the position and orientation of the planning target volume are computed with respect to the radiotherapy system and can be corrected as needed. This system is under clinical evaluation.

Computer Simulation↗

Quality assurance of the EORTC radiotherapy trial 22863 for prostatic cancer: the dummy run.

The results of a dummy run involving nine centers participating in a study comparing radiotherapy alone with radiotherapy plus hormone therapy in patients with high metastatic risk prostatic cancer (EORTC protocol 22863) show that, in all centers but one, patients are treated in the same way. However, they have also indicated that protocol compliance could be improved by a better assessment of the target volume, by taking into account of the use of protective shields and of variations in radiological density, by determining beam position on a large number of slices, and by the use of CT scan images for treatment planning.

Clinical Protocols↗

Bone cutting.

Bone cutting has always been a problem for surgeons because bone is a hard living material, and many osteotomes are still very crude tools. Technical improvement of these surgical tools has first been their motorization. Studies of the bone cutting process have indicated better features for conventional tools. Several non-conventional osteotomes, particularly ultrasonic osteotomes are described. Some studies on the possible use of lasers for bone cutting are also reported. Use of a pressurised water jet is also briefly examined. Despite their advantages, non-conventional tools still require improvement if they are to be used by surgeons.

Bone and Bones↗