Search PubMed⌕ Search

Biomedical subjects

J West

Publications and source records attributed to J West.

225 records · Page 13Linked to original sources

Dominant risk factors for retinopathy at clinical diagnosis in patients with type II diabetes mellitus.

A study of 270 newly presenting, previously untreated, type II diabetic patents revealed that 38 patients (14%) had already developed diabetic retinopathy (DR). Among this group, 26 patients had lesions of background diabetic retinopathy and 12 patients already had maculopathy or preproliferative changes. The aim of this study was to determine the risk factors influencing susceptibility to retinopathy, and to provide an accurate predictive value for diabetic retinopathy from a detailed multiple regression analysis that involved 27 demographic variables and the metabolic and hormonal responses during a meal tolerance test (MTT) at presentation. Compared to the nonretinopaths, the retinopaths had higher fasting plasma glucose levels (FPG) (mean +/- SD) (13.9 +/- 3.1 versus 11.6 +/- 3.2 mmol/L, p < 0.001), lower body-mass index values (BMI) (26.1 +/- 3.8 versus 29.3 +/- 5.0 kg/m2, p < 0.001) and higher plasma urea concentrations (6.0 +/- 1.9 versus 5.3 +/- 1.2 mmol/L, p 0.05). In contrast, gender and levels of blood pressure and other lipid levels did not influence the prevalence of diabetic retinopathy. A multiple regression formula for the prediction of diabetic retinopathy was derived and then used to categorize patients into high-risk and low-risk groups. The retinopaths also had higher HbA1c (p < 0.001), higher plasma glucose are under curve (0-2 h, p < 0.001), lower plasma insulin area under curve (0-22 h, p < 0.001), lower C-peptide area under curve (0-2 h, p < 0.01). They were also leaner (p < 0.001) and older (p < 0.05). However, these variables did not feature significantly in the multiple regression formula. The retinopaths were found to have higher risk probability values (25.1 +/- 11.5 versus 13.1 +/- 10.4%, p < 0.001). In the high risk group, 81.6% of retinopaths were identified. In the low-risk group, 63.8% of nonretinopaths were found. The incidence of diabetic retinopathy in type II diabetic patients at clinical diagnosis was found to be highly related to the degree of hyperglycemia, body-mass index, and to a lesser extent, renal impairment.

Adult↗

Diaper type and fecal contamination in child day care.

In this study, modern all-in-one, front closure, reusable cloth diapers were compared with single-use, disposable paper diapers for their effect on fecal contamination in the child day care environment. Four licensed child day care centers were surveyed from which 1722 bacterial samples were cultured. The frequency of isolation of fecal organisms ranged from a low of 12% of the total bacterial isolates at a center using cloth diapers to a high of 46% and 45%, respectively, obtained at a center using first paper and then cloth diapers. Diaper type, cloth versus paper, when the method of application and the handling are made comparable, showed no significant difference in the frequency or the intensity of fecal contamination in child day care centers, as measured in the play/sleep area, the diaper change area, or on the hands of the care givers and children. Future studies to control microbial contamination in child day care centers should focus on effective ways of reducing contamination of sink faucets, hands of the caregivers, and hands of the children.

Child Day Care Centers↗

Cardiac function after eight hour storage by using polyethylene glycol hemoglobin versus crystalloid perfusion.

Efforts to extend myocardial preservation for transplantation by crystalloid perfusion have been limited by edema and compromised function. We hypothesized that hypothermic perfusion preservation with a polyethylene glycol (PEG) conjugated hemoglobin solution may extend preservation times. The purpose of this study was to compare cardiac function after continuous perfusion by using a hypocalcemic, normokalemic crystalloid perfusate with and without the addition of PEG-hemoglobin (Hb). The hearts of 20 anesthetized and ventilated New Zealand White rabbits were harvested after cold cardioplegic arrest. Group I (n = 10) hearts were continuously perfused with a hypocalcemic, normokalemic 3% bovine PEG-Hb solution at 20 degrees C and 30 mm Hg for 8 hours. Group II (n = 10) hearts were continuously perfused with an identical crystalloid solution without PEG-Hb for 8 hours under the same conditions as group I hearts. Cardiac function was measured with a left ventricular force transducer after transfer to a standard crystalloid Langendorff circuit at 37 degrees C and an aortic root pressure of 59 mm Hg. After 8 hours of perfusion preservation, heart rate was similar for groups I and II (p = not significant [NS]). Coronary blood flow after and during preservation was similar between PEG-Hb and crystalloid preserved hearts (p = NS). Left ventricular developed pressure, peak dP/dt, and peak -dP/dt were superior in hearts preserved with PEG-Hb. Percent water of total ventricular weight was 82.0% for group I and 81.6% for group II (p = NS). Continuous perfusion preservation of rabbit hearts for 8 hours with a hypocalcemic normokalemic PEG-Hb based solution at 30 mm Hg and 20 degrees C yields left ventricular function that is superior to perfusion with a similar crystalloid solution without PEG-Hb, despite similar myocardial edema and coronary flow. Extended cardiac perfusion preservation with this PEG-Hb based solution deserves further study, including comparison with traditional cardioplegic preservation solutions.

Animals↗

Recovery of cardiac function after standard hypothermic storage versus preservation with Peg-hemoglobin.

Preservation of the heart for transplantation after infusion of cardioplegia and extirpation of a cardiac allograft results in an ischemic insult to the myocardium. This ischemic insult may lead to a loss of function in the transplanted heart. Hypothermic perfusion preservation with an oxygen hemoglobin carrying solution may avert ischemic injury and lead to improved recovery of cardiac function. The purpose of this study was to compare cardiac function after 8 hours of continuous hypothermic perfusion with a unique polyethylene-glycol-hemoglobin (PEG-Hb) solution to hearts preserved by 4 hours of hypothermic ischemic storage. Freshly extirpated hearts served as functional controls. The hearts of 26 anesthetized and intubated New Zealand white rabbits were harvested after cold cardioplegic arrest. Group I (n = 12) hearts were perfused with a PEG-Hb solution at 20 degrees C and 30 mm Hg for 8 hours. PO2 was maintained > or = 500 mm Hg. Group II (n = 7) hearts were preserved by cold ischemic storage for 4 hours at 4 degrees C. Group III (n = 7) were tested immediately after harvest. Left ventricular (LV) function was measured in the nonworking state at 15 minutes, 1 hour, and 2 hours after transfer to a standard crystalloid Langendorff circuit. Measurement of LV developed pressure, peak + dP/dt and -dP/dt revealed a superior trend between Group I and Group II hearts in comparison with freshly extirpated hearts. Heart rate was similar among all groups throughout testing (p = ns). Coronary blood flow was not significantly different between groups. Continuous perfusion preservation of rabbit hearts for 8 hours with PEG-Hb solution at 30 mm Hg and 20 degrees C yielded LV function that was similar to 4 hours of ischemic hypothermic storage. Furthermore, return of cardiac function after 8 hours of perfusion preservation using this PEG-Hb solution may be superior to that obtained in freshly extirpated hearts. These data suggest that some recovery of myocardial function may occur during perfusion preservation with this PEG-Hb solution after the ischemic insult of cardioplegic arrest. Continuous perfusion preservation using this PEG-Hb solution deserves further investigation in large animal transplant models.

Animals↗

Comparison and evaluation of retrospective intermodality brain image registration techniques.

PURPOSE: The primary objective of this study is to perform a blinded evaluation of a group of retrospective image registration techniques using as a gold standard a prospective, marker-based registration method. To ensure blindedness, all retrospective registrations were performed by participants who had no knowledge of the gold standard results until after their results had been submitted. A secondary goal of the project is to evaluate the importance of correcting geometrical distortion in MR images by comparing the retrospective registration error in the rectified images, i.e., those that have had the distortion correction applied, with that of the same images before rectification. METHOD: Image volumes of three modalities (CT, MR, and PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/ or from PET to MR. These investigators communicated their transformations again via the Internet to Vanderbilt, where the accuracy of each registration was evaluated. In this evaluation, the accuracy is measured at multiple volumes of interest (VOIs), i.e., areas in the brain that would commonly be areas of neurological interest. A VOI is defined in the MR image and its centroid c is determined. Then, the prospective registration is used to obtain the corresponding point c' in CT or PET. To this point, the retrospective registration is then applied, producing c" in MR. Statistics are gathered on the target registration error (TRE), which is the distance between the original point c and its corresponding point c". RESULTS: This article presents statistics on the TRE calculated for each registration technique in this study and provides a brief description of each technique and an estimate of both preparation and execution time needed to perform the registration. CONCLUSION: Our results indicate that retrospective techniques have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.

Brain↗