Search PubMed⌕ Search

Biomedical subjects

J W Shore

Publications and source records attributed to J W Shore.

At least 19 recordsLinked to original sources

Hypertrophic discoid lupus erythematosus of the conjunctiva.

PURPOSE: To report the ophthalmic manifestations of hypertrophic discoid lupus erythematosus of the conjunctiva. METHOD: Case report and review of biopsy results. RESULTS: A 58-year-old woman with a history of chronic blepharoconjunctivitis presented with an unusual raised conjunctival lesion. Previous biopsy slides were reviewed and interpreted as diagnostic of discoid lupus erythematosus, hypertrophic or verrucous type. Both blepharoconjunctivitis and the raised conjunctival lesion resolved with hydroxychloroquine therapy. CONCLUSIONS: A raised conjunctival mass in the context of refractory blepharoconjunctivitis should elicit suspicion for discoid lupus erythematosus. The hypertrophic variant of this disease can affect the conjunctiva.

Biopsy↗

Medpor Motility Coupling Post: a rabbit model.

PURPOSE: To verify if a Medpor porous polyethylene orbital implant (PPOI) (Porex Surgical, Atlanta, GA, U.S.A.), once vascularized, will tolerate a partially exposed titanium screw on its anterior surface. METHODS: Ten New Zealand white rabbits were enucleated and given Medpor PPOIs. Eight weeks postoperatively, Medpor Motility Coupling Posts (MCPs) (Porex Surgical) were placed into the orbital implants. Clinical tissue tolerance and histologic response to the new device were noted. RESULTS: The titanium screws were well tolerated by the animals. No case of post-operative infection, conjunctival inflammation, conjunctival erosion, MCP dislocation, or PPOI fragmentation was noted. A fibrous tissue growth over the titanium head was noted in all screws with a head height of 2.5 mm. The fibrous tissue overgrowth was not observed in screws with a head height of 4 mm or more. CONCLUSION: During the 6-month observation period, all implanted Medpor MCPs demonstrated favorable tissue tolerance and stable interfaces between the MCP and the conjunctiva and between the MCP and the PPOI.

Animals↗

Porous polyethylene channel implants: a modified porous polyethylene sheet implant designed for repairs of large and complex orbital wall fractures.

PURPOSE: To evaluate the effectiveness of a modified porous polyethylene implant in orbital fracture repair. A porous polyethylene channel implant (PPCI) has internal channels that accept mini- or microplates from conventional plating systems, facilitating fixation to bone in the reconstruction of large, complex orbital fractures. METHODS: The authors used 29 PPCIs to repair 25 orbits. Seventeen cases involved repair of an acute (less than two weeks after injury) fracture of one or more orbital walls. Eight cases represented delayed reconstruction of orbital walls for late enophthalmos or for residual defects after previous operations. RESULTS: A PPCI provides a stable platform for orbital soft tissue. Excellent results were obtained in all patients with acute orbital fractures, whereas good or excellent corrections of enophthalmos and hypoglobus were achieved in all patients who underwent late repair. There were no instances of orbital infection, implant exposure or migration, worsening diplopia, visual loss, or loss of structural support during 31 months of follow-up. CONCLUSIONS: A PPCI allows controlled placement of a porous polyethylene sheet with secure fixation to stable bone. The implant design allows it to be cantilevered from the orbital rim to serve as a stable platform when fractures are too large to support the implant in the posterior orbit. PPCIs are ideally suited for reconstruction of defects resulting from displacement of orbital walls and for repair of posterior floor fractures, medial wall fractures, and combined floor and medial wall defects.

Adult↗

The multidisciplinary management of psammomatoid ossifying fibroma of the orbit.

OBJECTIVE: To discuss the multidisciplinary management of psammomatoid ossifying fibroma (POF) of the orbit and to clarify the clinicopathologic terminology. DESIGN: The authors present a cohort of cases of POF involving the frontal and ethmoid sinuses and the orbit and discuss the nomenclature and literature. PARTICIPANTS: Three patients with POF and their treatment are discussed. INTERVENTION: Patients were worked up and treated by a multidisciplinary team using imaging studies and histopathologic analysis. Reconstruction, if necessary, was carried out at the time of excision or in a second-stage procedure. MAIN OUTCOME MEASURES: In each case, the lesion was completely excised and has not recurred. RESULTS: The diagnosis of POF was made in each case, and the patient underwent successful resection of the tumor. CONCLUSION: The authors' experience suggests that a multidisciplinary approach, including a radiologist, pathologist, neurosurgeon, otolaryngologist, craniofacial surgeon, and orbital specialist, may be useful in the evaluation and management of these lesions.

Adolescent↗

Porous polyethylene sheet implant with a barrier surface: a rabbit study.

Soft tissue adhesion to the porous polyethylene sheet implant (PPSI) raises the concern of postoperative extraocular motility disturbance after orbital blowout fracture repairs using PPSI. A PPSI with a barrier surface (PPSI-B) has been developed to reduce adhesion between soft tissue and the implant. Six PPSI-B and six conventional PPSI were implanted under the scalps of three New Zealand white rabbits. The implants were harvested at 2-, 4-, and 20-week intervals. Clinical and histologic comparisons were made between PPSI-B and PPSI with regard to adhesion at the soft tissue-implant interface. Clinically, PPSI-B demonstrated less adhesion between soft tissue and implant compared with the conventional PPSI. Both types of implants demonstrated a complete fibrovascular ingrowth by 2 weeks. Because PPSI-B causes less adhesion at the soft tissue-implant interface, consideration should be given to the use of PPSI-B in repairs of orbital blowout fractures in which extraocular muscle is exposed to the implant surface.

Animals↗

Use of botulinum A toxin in patients at risk of wound complications following eyelid reconstruction.

Our purpose was to determine the efficacy of botulinum A toxin (BOTOX) in promoting wound immobilization and preventing wound dehiscence in patients at risk of wound-healing complications following eyelid reconstruction. In 11 patients at risk of postoperative wound complications, we injected BOTOX into the periocular musculature in addition to standard suture tarsorrhaphy. Each patient experienced excellent wound immobilization and wound healing. There were no complications. Adjuvant use of BOTOX, in conjunction with suture tarsorrhaphy, immobilizes the eyelids and promotes wound healing in patients at risk of wound complications following eyelid reconstruction.

Adult↗

Choroidal and retinal detachment in antineutrophil cytoplasmic antibody-positive scleritis.

PURPOSE/METHODS: A 72-year-old woman with antineutrophil cytoplasmic antibody-positive vasculitis had a combined detachment of the choroid and retina. This unique initial manifestation was also associated with systemic and orbital manifestations, including brow ptosis, dacryoadenitis, and pneumonitis. RESULTS/CONCLUSIONS: This patient underwent vitrectomy for removal of a dense vitreitis and responded well to systemic cyclophosphamide. This case demonstrates that antineutrophil cytoplasmic antibody testing is useful for the diagnosis and treatment of Wegener's granulomatosis and microscopic polyarteritis-associated scleritis. The distinction between these two entities is often difficult to make.

Aged↗

Simplified method of sizing implants for orbital fracture repair.

PURPOSE/METHODS: Over the past six years, we have used ordinary radiographic film as a template for sizing alloplastic implants for orbital fracture repair in over 60 patients. The implants are made of such materials as titanium, Vitallium, and porous high-density polyethylene. Autoclaved 9.5 x 4.5-cm rectangles of radiographic film are easily trimmed, held by nontoothed forceps, inserted, and removed from the orbital cavity. RESULTS/CONCLUSIONS: We have found this simple and inexpensive technique to be superior to using aluminum templates that are supplied in commercially available plating sets.

Humans↗

Complications of porous spherical orbital implants.

PURPOSE: To determine the complications observed with using porous spherical orbital implants (hydroxyapatite and porous polyethylene) and the factors leading to their occurrence. METHODS: A total of 101 cases of porous spherical orbital implantation by five ophthalmic surgeons were reviewed retrospectively. The demographic data, diagnosis, prior surgery, type and technique of surgery, implant characteristics and prosthesis fitting were described in patients with complications. RESULTS: Eleven of the 101 patients had implant exposure. There were six male (1 with bilateral involvement) and four female patients, ranging in age from 2 to 71 years. Preoperative diagnosis included trauma in five patients, nontrauma in five, and tumor in one. Seven had prior eye surgeries. Three patients underwent evisceration, whereas eight underwent enucleation. Eight hydroxyapatite and three porous polyethylene implants were used with diameters of 16 to 20 mm. Three were unwrapped, six were wrapped in sclera, and two were wrapped in preserved fascia. Exposures, which generally occurred within 1 year, were grouped into small (1-5 mm), medium (6-10 mm), and large (> 10 mm). One delayed case occurred after drilling. Small stable exposures were managed conservatively. Larger exposures were managed either by implant revision or replacement. All patients were fit ultimately with a prosthesis. Histopathologic findings of explanted spheres showed fibrovascularization limited to the periphery with moderate inflammatory reaction. CONCLUSION: Complications were significantly higher in cases of eviscerations than enucleations. Complications occurred in implants either unwrapped or wrapped in homologous grafts. None of the autologous wrapping had exposure. Secondary procedures may initiate exposure when fibrovascular status of implant is inadequate.

Adolescent↗

Results of Müllerotomy and levator aponeurosis transposition for the correction of upper eyelid retraction in Graves disease.

BACKGROUND: Upper eyelid retraction in Graves disease may cause functional morbidity and aesthetic deformity. Surgery to correct thyroid-related upper eyelid retraction may result in temporal undercorrection with failure to eliminate lateral eyelid retraction, leading in turn to a poor eyelid contour postoperatively. METHODS: In 1984, one of the authors developed a new procedure for correcting moderate to severe upper eyelid retraction associated with Graves disease. The surgical technique consists of a Müllerotomy and recession of the levator aponeurosis combined with medial transposition of the lateral horn of the levator aponeurosis. The procedure was performed on 37 patients (72 eyelids). Müller's muscle was used as the spacer to set the eyelid height. Transposition of the levator aponeurosis allowed adjustment of eyelid contour. RESULTS: Thirty patients (58 eyelids) had excellent results, six (13 eyelids) had good results, and one (1 eyelid) had a poor result. No patient required re-operation for asymmetry, unacceptable contour, or malposition. Only one eyelid had significant overcorrection, and only one eyelid had significant undercorrection, requiring further surgery. The most frequent unwanted effects were high eyelid crease (24 eyelids) and residual temporal flare (6 eyelids); however, most of these were seen early in the series before the lateral levator transposition modification was added. CONCLUSION: This procedure allows successful and simultaneous correction of both eyelid position and contour in patients with moderate to severe thyroid-related upper eyelid retraction.

Adult↗

Endoscopic orbital decompression under local anesthesia.

Orbital decompression for Graves' disease has traditionally been performed with the patient under general anesthesia. Endoscopic instrumentation allows for removal of the medial orbital wall and floor through an intranasal approach with local anesthetic techniques. Twelve endoscopic orbital decompressions were performed on awake patients with uncovered eyes so that vision could be monitored throughout the procedure. Simultaneous lateral decompressions were performed in 11 cases. No intraoperative or postoperative complications occurred. Visual acuity remained stable or improved in all cases. Proptosis was reduced an average of 5.5 +/- 1.6 mm. In a comparable series of 29 endoscopic decompressions performed with patients under general anesthesia, proptosis was reduced an average of 4.8 +/- 2.0 mm. Endoscopic orbital decompression with patients under local anesthesia appears to be an effective technique that may provide an additional margin of safety in prevention of injury to the optic nerve.

Adult↗

Pseudodacryocystitis arising from anterior ethmoiditis.

The contiguous spread of inflammation from infected ethmoid sinuses to the surrounding tissues of the lacrimal drainage system can produce symptoms easily confused with acute dacryocystitis. We report the cases of two patients with presumed dacryocystitis whose patency of the lacrimal apparatus was established by probing, irrigation, and dacryocystography. Computerized tomography and magnetic resonance imaging demonstrated opacification of anterior ethmoid air cells adjacent to the region of the lacrimal sac. A greater awareness of this diagnostic possibility of pseudodacryocystitis arising from anterior ethmoiditis, together with improved noninvasive imaging techniques, will likely increase the observed incidence of this disease. This distinction is important since anterior ethmoidectomy, rather than dacryocystorhinostomy, is the treatment of choice when such pseudodacryocystitis proves unresponsive to antibiotic therapy. In misdiagnosed patients who undergo dacryocystorhinostomy, it is the coincidental limited anterior ethmoidectomy and not the lacrimal-nasal fistula that provides the cure.

Acute Disease↗

Aneurysmal bone cyst of the orbit associated with fibrous dysplasia.

Aneurysmal bone cyst is a rare but recognized osseous lesion of the orbit. We report the presentation, treatment, and postoperative course of an orbital aneurysmal bone cyst in a patient with McCune-Albright syndrome. To our knowledge, this report represents the first description of aneurysmal bone cyst of the orbit in a patient with fibrous dysplasia. Although visual loss in patients with fibrous dysplasia is most commonly due to narrowing of the optic canal, aneurysmal bone cyst should be considered in a patient with fibrous dysplasia who presents with decreasing vision in the face of a rapidly expanding orbital mass. The treatment in this case was drainage and debridement with prompt resolution. Although not necessary in this case, an alternative treatment includes packing with bone chips. Radiation is usually avoided because of the risk of iatrogenically induced sarcoma.

Adult↗