Prognostic value of left ventricular dysfunction at rest and during exercise in patients with coronary artery disease.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J W Moses.
Explore the source record for details and available documents.
To evaluate the efficacy of mask-mode digital subtraction angiography in selective coronary arteriography, we compared computer-based digital subtraction angiograms to standard film-based angiograms in 77 patients. Digital angiography was performed utilizing a 512(2) matrix and a framing rate of 30 frames/second. Radiation parameters were selected after a pilot dose-ranging trial, and were 70-120 KVP, 10-30mA and 0.8 to 5msec pulse width. Single view digital angiograms were compared to single view conventional angiograms in 27 patient; the two angiograms agreed within one grade of severity in 84 percent of the lesions or normal arteries seen. Multiple view digital angiograms were compared to multiple view conventional angiograms in 50 patients. Agreement within one grade of severity was found for 90 percent of lesions or normal arteries. Digital angiography detected 95 percent of collateral vessels seen on conventional angiography. We conclude that computer-based mask-mode digital subtraction angiography can be utilized in selective coronary angiography to obtain results comparable to those using conventional film-based cineangiography.
The hemodynamic effects of intravenous administration of bepridil were evaluated in 17 patients with chronic coronary artery disease who underwent cardiac catheterization. Of the 17 patients, 8 received bepridil, 2 mg/kg of body weight, for 15 minutes followed by 1 mg/kg for 15 minutes (group A), and 9 received 3 mg/kg followed by 1 mg/kg (group B). In group A, the systemic blood pressure (BP) decreased (p less than 0.05) and left ventricular end-diastolic pressure increased minimally (p less than 0.05). Heart rate (HR), pulmonary artery pressure, cardiac output (CO), stroke index, pulmonary vascular resistance and systemic vascular resistance (SVR), stroke work index, "contractility" (+dP/dt) and double product (HR X systolic BP) showed no significant change after bepridil infusion. In contrast, in group B, while +dP/dt decreased (p less than 0.01), SVR also showed a strong downward trend and changed significantly more than in group A; in the context of the latter alteration, CO increased significantly. In addition, the double product (less than 0.025) and systemic BP (p less than 0.05) decreased, though other parameters did not vary significantly. Thus, although a modest dose-related negative inotropic effect (decreased +dP/dt) was seen, dose-related direct systemic vasodilatation (decreased SVR) led to improved cardiac performance (increase in cardiac index) at the larger dose.
The acute hemodynamic effects of both sublingual nifedipine (N) and intravenous hydralazine (Hy) were studied in 5 patients with primary pulmonary hypertension to ascertain whether the capacity for pulmonary vasodilatation was generalized or drug-specific, and to determine which of the 2 agents had preferential pulmonary vasodilatory effects. For the group as a whole, neither N nor Hy produced changes in heart rate, mean pulmonary capillary wedge or right atrial pressures. Both N and Hy reduced mean systemic arterial pressure (before N 90 +/- 8 mm Hg, after N 76 +/- 7 mm Hg, p less than 0.01; before Hy 92 +/- 11 mm Hg, after Hy 68 +/- 8 mm Hg, p less than 0.05), and decreased systemic vascular resistance (before N 1,558 +/- 645 dynes s cm-5, after N 1,192 +/- 430 dynes s cm-5, p less than 0.05; before Hy 1,700 +/- 415 dynes s cm-5, after Hy 957 +/- 285 dynes s cm-5, p less than 0.05). In addition, N administration resulted in an increased cardiac output (before N 4.5 +/- 2.0 liters/min, after N 4.8 +/- 2.0 liters/min, p less than 0.01); Hy administration was associated with a more varied effect on cardiac output (before Hy 4.0 +/- 1.0 liters/min, after Hy 5.3 +/- 1.8 liters/min, p less than 0.10, difference not significant [NS]).(ABSTRACT TRUNCATED AT 250 WORDS)
Angiographically demonstrable coronary collateral vessels are believed to preserve myocardial function at rest, but disagreement exists regarding the importance of collaterals in mitigating exercise-induced ischemic dysfunction. Therefore, we used radionuclide cineangiography during exercise to assess the left ventricular (LV) functional effects of collateral vessels in 125 patients with at least 1 major coronary artery that had greater than or equal to 90% diameter stenosis but without prior myocardial infarction. Regional LV function, graded on a 4-point scale, worsened during exercise by at least 1 grade in 14 of 43 regions (33%) with good collaterals, and in 70 of 98 without good collaterals (p less than 0.001). Of the 43 good collaterals, 14 were supplied by arteries with greater than or equal to 75% stenoses; 10 of 14 regions (71%) thus supplied worsened by at least 1 grade (p less than 0.01). The ischemia-mitigating effect of coronary collateral vessels also affected the magnitude of exercise-induced global dysfunction. Of 43 patients with only one greater than or equal to 90% stenotic artery, 18 had good collaterals; in these patients, average LV ejection fraction (EF) at rest was 51 +/- 8%; LVEF during exercise was 46 +/- 7%. In the 25 patients without good collaterals, LVEF at rest was 52 +/- 7%, and LVEF during exercise was 41 +/- 9% (p less than 0.005 vs good collaterals).(ABSTRACT TRUNCATED AT 250 WORDS)
A prominent "v" wave relative to the "a" wave in the jugular vein and right atrial pressure tracing is considered to be a common haemodynamic sign of atrial septal defect. Since the prevalence, age relation, and haemodynamic determinants of the "v" greater than or equal to "a" wave configuration have not been studied the pressure recordings from 15 adults and 80 children with an isolated secundum atrial septal defect in sinus rhythm and from 40 adults and 55 children in sinus rhythm without structural cardiac abnormalities or with coronary and valvular heart disease were studied to assess the sensitivity and specificity of the "v" greater than or equal to "a" wave configuration in atrial septal defect. Only 20% of adults with an atrial septal defect had prominent right atrial "v" waves compared with 63% of children, although the specificity was quite high for each group. In adults "left atrialisation " of the right atrium ("v" greater than or equal to "a" wave) occurred in younger patients with higher right atrial and right ventricular end diastolic pressures. In contrast, in children no age related or haemodynamic determinants for the "v" greater than or equal to "a" pattern were found. In addition, most adults but few children with an atrial septal defect had "right atrialisation " of the left atrial wave configuration ("a" greater than "v"). This was found in older adults with lower right atrial and right ventricular end diastolic pressures and in older children with larger left to right shunts. Thus in contrast to children adults with an atrial septal defect rarely show a prominent "v" wave in the right atrium. The presence of a prominent right atrial "v" wave in adults with an atrial septal defect is associated with relatively higher left atrial and right heart pressures than is the absence of this sign and may be related to relatively higher systolic transatrial flow in these patients. The relative paucity of prominent right atrial "v" waves in older adults suggest that the systolic phase flow may diminish with age, possibly from progressive alteration in compliance of the chronically dilated right ventricle.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Standard contrast left ventriculography with catheter placement into the left ventricle entails risks and inconvenience. Computer-based digital subtraction techniques now permit high contrast left ventriculography after intravenous administration of contrast medium. To compare the accuracy of intravenous digital subtraction left ventriculography with film-based, standard contrast ventriculography, we assessed left ventricular function by both methods in 32 patients (8 with valvular disease, 22 with coronary disease and 2 with atypical pain). Studies in 31 of 32 patients were considered. Left ventricular ejection fraction by standard contrast ventriculography ranged from 24 to 88%. Digital subtraction angiography was performed with bolus injection of radiopaque contrast material (30 cc at 20 cc/s) into the inferior vena cava. The two methods correlated closely in end-diastolic volume (correlation coefficient [r] = 0.96, probability [p] less than 0.001), end-systolic volume (r = 0.97, p less than 0.001) and ejection fraction (r = 0.98, p less than 0.001). Segmental function was assessed visually; precise agreement existed between the two techniques in 123 (79%) of the 155 segments (p less than 0.001). It is concluded that intravenous digital angiography provides left ventricular images of sufficiently good quality to allow accurate quantitative assessment of global left ventricular function and volumes as well as determination of regional function.
Exercise left ventriculography has been shown to be a sensitive and specific tool for the detection of coronary artery disease. At the present time, such studies require radionuclide-base methods. Computer-based techniques recently have been shown to provide high resolution images of the left ventricle when the levophase of an intravenous injection of radiopaque contrast medium is imaged with fluoroscopy. To evaluate the possible efficacy of using "intravenous digital subtraction left ventriculograms" in exercise ventriculography, such ventriculograms were performed at rest and during maximal supine bicycle exercise in 31 patients. Studies that could be analyzed were obtained in 29 patients. In 21 patients with coronary artery disease, ejection fraction was 58% at rest and 45% with exercise (p less than 0.001 vs. rest). In contrast, in seven patients with no coronary artery disease, ejection fraction was 65% at rest and 69% with exercise (difference not significant). In a subgroup of 8 patients with "severe" coronary obstruction, the change in ejection fraction from rest to exercise was -18%, while in the remaining 13 patients with less severe disease, it was -9% (p less than 0.001). All patients with coronary artery disease manifested new or worsening segmental wall abnormality with exercise, compared with two of seven patients without coronary disease (p less than 0.01). Sixteen patients underwent rest and exercise radionuclide cineangiography in addition to digital subtraction angiography. There was a strong correlation between the two techniques for ejection fraction at rest (r = 0.78, p less than 0.001), ejection fraction and with exercise (r = 0.83, p less than 0.001) and change in ejection fraction from rest to exercise (r = 0.88, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
A percutaneous wire-guided double lumen intraaortic balloon pump was tested in 44 patients, 15 with cardiogenic shock. The balloon volume is 40 ml, the material is Avcothane, and the central lumen will pass a 0.035 inch (0.889 mm) wire guide. Standard Seldinger technique was followed by successful insertion in 40 patients (90 percent) with no recognized vascular trauma. Counterpulsation was excellent and central pressure monitoring through the balloon lumen showed good fidelity. Iliofemoral thrombosis occurred in 5 percent of patients. The overguide technique is simple, successful and atraumatic.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Nineteen patients with recurrent rest angina were given oral nifedipine. All patients had chest discomfort refractory to propranolol and oral or topical nitrates given to tolerance. The addition of nifedipine, 30 to 120 mg daily, abolished rest angina in 14 patients, decreased its frequency in two, and had no effect in three patients. Five of seven patients on long-term nifedipine (mean, 6.2 +/- 3.4 months) remained free of rest pain. Of seven patients who had their nifedipine dose decreased or discontinued, five had recurrent rest angina. Of the 19 patients, 16 had coronary angiography. Five had three- vessel obstructive disease (greater than 75% lesion), six had two-vessel obstructive disease, and five had one-vessel obstructive disease. The remaining three unstudied patients had pathologic Q waves in the ECG. Thus nifedipine appears to be an efficacious agent in the treatment of refractory rest angina in patients with obstructive coronary artery disease.
Explore the source record for details and available documents.